Product catalogue. Software for Building Services Calculation, Energy Requirement and an intelligent connection with AutoCAD MEP

Similar documents
Passiv Haus Institut. Certification as "Quality Approved Passive House" Criteria for Non-Residential Passive House Buildings

OPERATION AND CONTROL OF THERMALLY ACTIVATED SLAB HEATING AND COOLING SYSTEMS

STEADY STATE AND DYNAMIC THERMOPHYSICAL PARAMETERS OF TRANSPARENT BUILDING COMPONENTS

Renewables. Vacuum Tube Solar Systems. Solar Energy to the Power of

All-rounder in TAI. NEVARIS AVAilable everywhere.

BUILDING DESIGN AND THERMAL INERTIA: WHEN, WHY, WHERE

Following CEN Mandate M/480 [1] a comprehensive

Dienstleistung. Certification as "Quality Approved Passive House" Criteria for Residential-Use Passive Houses

Nilan VPL Active heat recovery and cooling (air/air)

CEN/TC 89 - Thermal performance of buildings and building components

NEW! THE FLEXIBLE PROFESSIONAL INSULATION WITH REVOLUTIONARY CHARACTERISTICS. even easier to use

Proceedings Cold Climate HVAC Sisimiut, Greenland, March 2009

Work Package 2: Performance of naturally ventilated buildings

ENERGY EFFICIENT RETROFIT MEASURES GUIDE

Technical System Catalogue Modular PDU (PSM)

SIMARIS Software Tools

ComBridge Studio Evolution Smart Building Concepts

Who we are. Berlin. Cologne. Vienna

Stadtwerke Konstanz Customer Centre, Constance

Case Study: Bio-Climatic Building Design for Tropical Climates

Coupled windows in the current guise

HEAT LOSS REDUCTION OF ENERGY-EFFICIENT HOME BY BUFFER AREAS. Alexander Dvoretsky, KseniaKlevets

ISO INTERNATIONAL STANDARD. Energy performance of buildings Calculation of energy use for space heating and cooling

AIRCOOL VENTILATORS FURTHER INFORMATION

ARCH-MEDES (I) CONSULTANTS PVT. LTD. Green Park Delhi

INTRODUCTION TO WUFI PASSIVE & PHIUS+ 2015

CAR PARK MANAGEMENT WITH IFMS AND SAP

The Centre for Sustainable Building (ZUB) * A Case Study

Potential of ventilative cooling in German residential buildings

22 DIGITAL SERIES CLIMATEMASTER GEOTHERMAL HEATING AND COOLING

MODELLING THE IMPACTS OF NEW UK FUTURE WEATHER DATA ON A SCHOOL BUILDING

30 DIGITAL SERIES CLIMATEMASTER GEOTHERMAL HEATING AND COOLING

Available online at ScienceDirect. Energy Procedia 78 (2015 )

Economical paving of 4.0-m to 12.0-m wide concrete slabs Slipform Paver SP 1200

TiPass The Global Secure Solution for Fraudulent Identity Detection and Document Forgery Inspection

INTEGRAL BUILDING AND ENERGY DESIGN OF AN OFFICE BUILDING COMPARISON OF INITIAL DESIGN IDEAS WITH MONITORED RESULTS

EnerPHit. Criteria for Residential-Use Refurbished Buildings

Pallet Handling System (PHS)

ARBURG host computer system (ALS)

LOGIC FLUE & ACCESSORIES GUIDE.

Supply Chain Execution Supply Chain Execution for Microsoft DynamicsTM AX

Ventilative Cooling potential tool

Building & Ductwork Airtightness Standards

UMWELT 75 YORK ST TERALBA. Australian Institute of Energy - Peter Jamieson. April 2014

Observation of Liquid-filled Window without Presence of Liquid in Test Chamber

FEDERATION TOWER MOSCOW DIFFERENT ROOM CLIMATES UNDER ONE ROOF

ENERGY PERFORMANCE OF DIFFERENT TYPES OF DOUBLE SKIN FACADES IN VARIOUS CLIMATES

Made by ARBURG Lossburg, Germany

ARENA NX CONNECTED BUILDING SUPERVISION. Benefit from the user-friendly and powerful connectivity designed to maximise operational performance.

LOGIC FLUE & ACCESSORIES GUIDE.

Optimum offered a fabulous service from planning through to installation and aftercare.

Design Strategies and Guide lines for Tropical Coast of Pakistan, Using Climate Consultant

EPLAN Fluid Fluid power engineering

BUILDINGS & OFFICE SPACES INDUSTRIAL SOLUTIONS. Combined production of Heat and Power. Waste Heat Recovery Bottoming Cycle

Framing station WEM 100/150/250

COMFEN A COMMERCIAL FENESTRATION/FAÇADE DESIGN TOOL

OFSETTING THE NATURE

Passive Houses in South West Europe

SOLAR PHOTOVOLTAIC ASI GLASS E. ASI Glass. Integrated Architecture Powered by the Sun

ECO-THERM. MOBILE FACTORY Technical information on innovative construction methods

Industrial PU Boot Manufacturing

Investigation of a Solar active glass facade

Influence Of Building Zoning On Annual Energy Demand

ProjectManagement for Engineering Companies

HOW CURRENT TRENDS IN THE DESIGN OF FACADES INFLUENCE THE FUNCTIONAL QUALITY OF INTERIOR SPACES

AUTOMATION ENGINEERING

SMART FIXING SYSTEMS profiles pro ofilees

This document is a preview generated by EVS

ProjectManagement for Consulting and Software Companies

Creating Synergies 1. Increase temperature of surfaces 2. Reflect heat 3. Regulate moisture

All panels can be supplied in a range of styles, to suit the applications pictured below.

Solar and Internal Gains in Low-Energy and Passive Houses

TiRack ENERGY STORAGE SYSTEMS. For highest demands in industrial applications

Energy Efficient Buildings in Germany An Introduction

2000 Antwerp, terraced house

Principles of Green Architecture

IBP FRAUNHOFER INSTITUTE FOR BUILDING PHYSICS IBP ENERGY SYSTEMS

State-of-the-art noise prediction software. EXTENSIONS Overview of available CadnaA extensions

FVA Workbench. The professional simulation platform for designing innovative transmission systems. FVA GmbH

Drawing heating energy from the ground. Cover your own demand for heating and hot water with geothermal energy

Get More Out of Gauging. Production Decision Intelligence. On-line.Detailed.Exact. Production Quality Data Base. Save Costs Maximize Quality

Control, Adjust and Move with RA Linear Actuators

ZEM ds : Case studies

ID-Spec Large 3.0. Software for Electrical Installation Design in Industrial and Tertiary Buildings

alpha-innotec origen and alpha-innotec Join a winning team heat pumps The heat pump specialist

ENGEL Oil Maintenance

Product data. HERADESIGN superfi ne

A class of its own JUMAG STEAM BOILER COMPACT INFORMATION STEAM BOILER WATER SUPPLY MODULES BLOW DOWN VESSEL COMPACT STEAM SYSTEM.

Your system rendered fully transparent with SES System Efficiency Service

/2014 en-gb. The Formwork Experts. Concremote software. User Manual Please retain for future reference

Technical Documentation. EiPlan5. Version : 4.0 Issued :

Newport City Council Bettws High School Underfloor Heating Specification CONTRACT 2

PE Structured Wall Pipes

THE PROGRAMS AND RESOURCES OF FACULTY OF MECHANICAL ENGINEERING

EPLAN Pro Panel Virtual control cabinet engineering

...About our Software

Underfloor Heating System

WALL LINER PRODUCT DATA SHEET FAÇADE & ROOF SYSTEMS

Energy efficiency of a solar domestic hot water system

SUMMER THERMAL COMFORT IN TYPICAL FRENCH RESIDENTIAL BUILDINGS: IMPACT ASSESSMENT OF BUILDING ENVELOPE INSULATION ENHANCEMENT

Transcription:

Product catalogue. Software for Building Services Calculation, Energy Requirement and an intelligent connection with AutoCAD MEP

Building construction components U-value / vapour diffusion Programme for the calculation and administration of all kinds of components for functions in building construction and technical building equipment. Free administration of building materials and components. Calculation of U-values from layer structure with automatic conversion. Support of various special cases for air spaces as well as transparent and non-transparent components. Layer thickness optimisation. Components with known U-value, composed components. Temperature profile with dew point. U-value according to EN ISO 6946 Window calculation according to EN ISO 10077-1 Construction material dataset according to BS, DIN, ÖN and SIA Components with homogenous layer structure Composed components (e.g. facades) U-value calculated from temperature measurement data Layer thickness optimisation in order to comply with specifi ed heat conductivity coeffi cients Condensate formation and evaporation Proof of core condensate Proof of several condensate zones in complex layer structures Graphic illustration for winter and summer Temperature profi le as graphic and chart Immobile air layers, fastenings and inverted roofs Calculation of heat transfer resistors according to EN ISO 6946, Annex A Determination of weight per unit area Graphics as image and printout Optional: vapour diffusion module Data network with programmes for heating load, cooling load and energy requirement 2

Cooling load calculation Calculation of cooling load and room air temperature using the detailed calculation method according to VDI 2078 Country specific datasets (e.g. UK, Ireland, India etc.) can be obtaines and added. Quick and simple editing of data in table form using special facilities for changes and alternatives calculation. Consideration of gliding room temperature, cooling of components and external shading. Time profiles for loads, target temperatures and operating modes. The programme can be used for the compilation of proof during the planning phase as well as for the optimisation of the building and systems included therein. Calculation methods according to VDI 2078 Room air temperature constant or fl oating according to EN 13779 Cooling of components Worldwide application by free administration of temperature and radiation data Continuous or interrupted operation Controlled or not controlled air conditions Room air temperature freely fl oating Any arranged and slanted components Any temperature in the adjacent rooms Calculation of the structural heaviness class from room data Loads for persons, lighting, machines and material throughput With or without humid heat dissipation Any air volume streams (e.g. intensive night time ventilation) Self-shading of structured facades External shading and ground refl exion Interior/exterior sun protection equipment Calculation of supply air volume fl ow Results in table form or as a graphic Data network with programmes for heating load, energy requirement and AutoCAD MEP Energy requirement Programme for the calculation and analysis of the energy requirement of heated and air-conditioned buildings in accordance with VDI 2067 part 10+11 on the basis of real hourly weather data throughout the year. Energy requirement may consist of heating, cooling, humidifying and dehumidifying. It is possible to consider utilisation profiles thus allowing for the calculation of heating-up behaviour, cooling and more. Detailed cooling load calculation according to VDI 2067 sheets 10 and 11 Availability of Meteonorm test reference years for locations around the world Hourly energy requirement for heating, cooling, humidifying and dehumidifying Basic and individual usage according to VDI 2067 Room air temperature freely fl oating Heating and cooling limit Limited system performance for heating/cooling Annual, weekly and daily profi les for internal loads and operating data Sun protection, building element cooling, persons, lighting, machines, material throughput Exterior air volume streams from adjacent rooms or thermally treated Determination of room type on the basis of room construction Additional structural heaviness class XL (extra light) Self-shading of structured facades Controllable hourly individual results Results in table form and graphic Annual energy requirement for the entire buildings or for each room Daily results or specifi c (as required) time intervals Temperature pattern and extreme values Relative frequency statistics of exceedance/undercut Data network with heating load, cooling load and AutoCAD MEP 3

Heating load BS EN 12831 Programme for the calculation of heating load according to BS EN 12831 for projects of all kind and scope. Fast and simple editing in table form using various graphic and logic facilities, e.g. chain dimensions, dormers and the linking of adjacent spaces. There are special functions for specific cases, e.g. high rooms and more. BS EN 12831 European wide application General or detailed thermal bridges Additional heating capacity in general or for each room Calculation of components in contact with the ground, simplifi ed or detailed according to EN ISO 13370 Calculation of horizontal and vertical boundary insulations on ground areas Chain dimension wizard (for the simple input of external dimensions) Component wizard (for the automatic generation of the room limitation areas of complicated room geometries, e.g. attic rooms, dormers) Area and volume wizard (for the simple input of room and/or enclosing wall areas and volumes, e.g. in case of open construction) Logical building model with reference to rooms Balance diagrams, graphics and the comparison of variants Central data change function Data network with programmes for radiator, fl oor heating, cooling load and AutoCAD MEP Radiator design Programme for the design of room radiators with or without consideration of thermal comfort (in accordance with VDI 6030). Reading and processing of manufacturer s datasets or free editing of additional. Application of the programme for new building design and existing building renovation, e.g. recalculation or conversion of existing radiators. Fast processing in table form with constant graphical checking. Simple switching and verification of alternatives, e.g. product, assortment or basic conditions of the design Manufacturer datasets EN 442, VDI 3805-6 or BDH 2.0 and/or free editing Products and assortments can be combined within the project Conventional radiator design or with consideration of thermal comfort criteria (requirement steps 1 to 3) compensation of descending air and radiation as an option Storing typical design profi les Automatic quick design Design within specifi ed tolerances Consideration of pressure gauge, surface availability, connection type and connection variant Automatic or manual capacity distribution Recalculation or conversion of existing radiators Central data change function Consideration of heating reserve by means of separate radiators or the increase of supply temperature or mass fl ow Determination of real return temperature Quick and simple comparison of alternatives Equipment automatically according to manufacturer s data Bill of quantities for contract specifi cations or quotation Balance diagram and/or graphic illustration of the outcome Data network with programmes for heating load, fl oor heating, piping network and AutoCAD MEP 4

Radiator piping network calculation Programme for designing, recalculating and adjusting complex double-pipe radiator networks of any size including valve setting. The programme supports industrial fittings datasets, e.g. thermostat and control valves, fixed resistors, overflow and differential pressure regulating valves and others. Water or other liquids. By means of rows it is possible to define individual planning standards and allocate them to the network or to partial networks. Many facilities for quick, simple and safe editing and checking. Renovation of new and old buildings Dimensioning and recalculation Hydraulic adjustment and valve setting Industrial datasets VDI 3805-2 (e.g. Danfoss, Heimeier, Overtrop, KSB, oreg-drayton ) Differential pressure regulating valve, fl ow control, overfl ow control and combined control valves Gravity and thermal losses as an option Consideration of valve authority Various media (e.g. water with addition) Flow-related zeta-value calculation Double-pipe systems ramifi cation systems Pipe design in accordance with Tichelmann Single-pipe radiator with special valves Distributor connections (e.g. fl oor heating) Systems which can be combined as desired Calculation of cold water systems Systems with several heating circuits Consideration of system deviations (1 K, 2 K) Observance of minimum nominal distances Any synchronisms Quick working with net components Visual illustration of current string Mass confi guration with item numbers Data network with AutoCAD MEP Floor heating EN 1264 Design of a panel heating on the basis of the manufacturer s data. A design made under the assumption of standard conditions can be made as quick design immediately after the heating load calculation. Alternative for the detailed planning with deductible and covered areas, peripheral zones, supply pipes, integrated heating circuits, deviation of areas, etc. Optimisation of supply temperature and material consumption. Residual heat requirement. Material summary with item numbers. Import of manufacturer s datasets Selection of a system from a type list, e.g. fl oor heating, industrial fl oor, wall heating, etc. Requirements for supply temperature, minimum and maximum spread angle Proof of critical rooms and supply temperature optimisation Automatic generation of peripheral zones One-click quick design including heating circuit allocation Automatic heating circuit division if the limit of pressure loss or pipe length are exceeded Heating circuits with fi xed dimensions, e.g. taking pavement joints into account Peripheral zones and dwelling zones integrated or in separate heating circuits Series connection of heating circuits, e.g. porch / toilet / corridor Calculation of excess heat, e.g. corridor with heating circuit distributors Variant design with different basic conditions Consideration of the heat loss of traversing supply pipes as an option Consideration of different insulations and subsoil temperatures Adjustment and valve presetting project-based or for each heating circuit distributor Graphic allocation of heating circuits to distribution connections Many pages of printouts including landscape variant Data network with calculation of radiator and piping network Bill of quantities including equipment determination 5

GBIS 1.0 - More Than Just An Interface GBIS connects AutoCAD MEP with SOLAR-COMPUTER calculation programs for buildings and systems in an intelligent way. GBIS creates SOLAR-COMPUTER toolboxes in the user interface of AutoCAD MEP, checks drawings for incalculable drawing errors and prepares drawing data for calculation purposes. The real advantage, however, is the integration of the calculation results in form of automated data updates, labels or dimensional adjustments in the drawings. Moreover, GBIS provides throughout all calculations, for the visualisation of rooms, radiators, pipe work, etc. GBIS stands for Green Building Information System. In the background, it saves any linked data for comfortable and effi cient working throughout all consultation, planning and implementation phases. The GBIS concept Working in a simple, quick and intuitive way Intelligent data network between AutoCAD MEP and building and system calculation Import and export of building data, in particular of room geometries Import and export of radiator data Import and export of pipe network data Verifi cation of the function of drawing data Function for setting the SOLAR-COMPUTER room stamp Automatic addition of CAD room characteristics data with calculation results Visualising the position of the current calculation in the CAD drawing (e. g. zoom on the hit radiator) Highlighting of numerous room characteristics (heating load, temperatures, etc.) by colouring the room GBIS 1.0 connects AutoCAD MEP 2010 and SOLAR COMPUTER software (heating load, radiator, heating pipe system and cooling load) 6

The Modular Structure of SOLAR-COMPUTER Software Facilitates Parallel And Process Orientated Working U-Value Calculation Cooling Load Heating Load Building Energy Requirement Radiator Design Ground Floor Heating Heating Pipe network On complex projects numerous designers are often working simultaneously on different phases and packages. SOLAR-COM- PUTER software supports this with its unique modular concept. Each module can be used as a stand-alone software, however, maximum benefi ts are achieved by its ability of data exchange and transfer in-between the various SOLAR-COMPUTER modules. In addition, external data (from e.g. key suppliers and manufacturers of components) can be imported into the SOLAR-COM- PUTER calculation software SOLAR-COMPUTER software - Overview Building Physics - U value calculation EN ISO 6946 - Water vapour diffusion Heating - Heating load calculation (BS EN 12831) - Radiator calculation - Floor and wall heating (BS EN1264) - Pipe network calculation - Pipe calculation in accordance with Tichelmann - Single pipe calculation Climate - Cooling load calculation VDI 2078 - Component cooling - Cooling load for international Projects - Room air temperature calculation Energy - Energy requirement VDI 2067 part 10+11 CAD Intelligent Interface GBIS for AutoCAD MEP Please contact us or visit our website www.solar-computer.co.uk for further information 7

About SOLAR-COMPUTER UK Ltd: SOLAR-COMPUTER UK Ltd. was established in 2009 and is the branch for sales and distribution of SOLAR-COMPUTER calculation programmes in the UK and Ireland. For 30 years, the German head offi ce of SOLAR-COMPUTER GmbH has been developing high-quality software applications for building physics and its associated calculation of energy, heating, sanitary, climate, ventilation and cost effectiveness. During this time, the company has continuously strengthened its position as a market leader providing high-quality service engineering software in Germany, Austria and Switzerland. Presently, more than 30 employees are working in development, marketing and sales for international customers. The software particularly stands out due to its modular structure allowing for solutions which are tailored to the needs of the customer. Due to our vast experience with interface programming, SOLAR-COMPUTER has achieved major benefi t for the user throughout the entire consulting and planning process. The software sets the scale for user friendliness when calculating most complex tasks. Support Center Our qualifi ed staff will assist you in our support center at any time. We will provide support in all aspects of the product. If you have any further questions with regards to the installation and the application of the product or in case of any further enquiries we are here to help you. Maintenance/Service Become a service customer! Use the benefi ts of our comprehensive support. As a service customer you need no longer worry whether your software still complies with the current standards. Once a year we will automatically send you all updates of your software. Interim updates can be accessed on our internet page. Furthermore, our competent support staff will give you free advice and practical support. we are here to help you. Please send your questions via internet, email or directly to: SOLAR-COMPUTER UK Ltd 133 London Road Twickenham TW1 1EF Tel. 020 87449026 Fax 020 87449026 E-Mail: info@solar-computer.co.uk www.solar-computer.co.uk Grantor of licence: SOLAR-COMPUTER GmbH Postfach 33 08 D-37023 Göttingen Tel. +49 551 79760-0 Fax +49 551 79760-77 E-Mail: info@solar-computer.de www.solar-computer.de Copyright 2009 SOLAR-COMPUTER GmbH, Änderungen vorbehalten