CONTENTS. Wet Scubber Features 3. Parts 4. Models 6. Technical Specification. Warranty MiniLab 7 - MaxiLab MaxiLab

Similar documents
CONTENTS. Features 3 Technical Specifications 4 Parts 5 Parts with Optional MiniLab 6 Options & Accessories 7 Warranty 8. 2

CONTENTS. Standard Hood Features 3. Laboratory Fume Handling 4. Stainless Steel Fume Hood -AD Series 5. Models 6. Parts 7. Options and Accessories 8

92831 TEL: (714) FAX:

Installation Guide Document No Transaction Windows Copyright 2017 Terra Universal Inc. All rights reserved. Revised October 2017

Quick-Start Operating Guide Document No Process Gas Cooler Copyright 2010 Terra Universal Inc. All rights reserved. Revised October 2010

92831 TEL: (714) FAX:

WheelTime Exchange Standard Terms and Conditions. ZF Services North America, LLC (ZFSNA) 9/1/2015 ZF SACHS Heavy Duty Clutch and Shocks

4300 WINDFERN RD #100 HOUSTON TX VOICE (713) FAX (713) web: twrlighting.com IMPORTANT!!!

TAYLOR FORGE STAINLESS

Lithonia Lighting Terms and Conditions of Sale

POLICY AND PROCEDURE MANUAL

STEEL PIPE NIPPLES SEAMLESS Price Sheet PNS-9.16C Effective: September 5, 2016 Cancels Price Sheet PNS-10.15C of October 5, 2015

General Information. Southwest Office Edwards Road, Suite B105 Cerritos, CA (Main Phone)

Maintenance Bypass Breaker Cabinet Series Configuration 2. Installation and Operation Manual

INSTALLATION PROCEDURE

NOTICE: To the prices and terms quoted, there will be added any manufacturers or sales tax payable on the transaction under any effective statute.

78-RK VARIABLE SPEED HEAVY DUTY VIBRATOR OPERATING MANUAL

Field Economy Unit Instruction Manual

Maintenance Bypass Breaker Cabinet Series Configuration 5. Installation and Operation Manual

Lighting Services Inc. QuickShipExpress 5-10 Day Service

Thermoelectric Cooler

INSTALLATION PROCEDURE

PVC WATER FITTINGS List Price Sheet

OPERATION AND INSTALLATION MANUAL

Installation and Operation Manual

Thermoelectric Coolers. All Models INSTRUCTION MANUAL. Rev. G 2016 Pentair Equipment Protection P/N

CMT MANUAL 1.2 TERMS AND CONDITIONS

Aero Tec Models 700 & 750 (115 vac)

Structural Performance Tests of VHB Structural Glazing Tapes

TERMS AND CONDITIONS OF SALE

END TRUCKS WHEEL SIZES: 9", 12", 15" & 18"

Model 10A. Model 20A. Operating Manual. ECG Simulator. ECG / Arrythmia Simulator

WIC/WICD/WICL/WICDL & WB/WSB Series. Effective Date: 2017 IMPORTANT INFORMATION READ BEFORE USE WIC-ICED COLD PAN 4-5/8" STANDARD DEPTH

INSTALLATION PROCEDURE


a u t o b a h n price list january 2018

Drag Chain Conveyor Installation and Operation Manual

Carbon Forged Steel Fittings

AIR CHAMP PRODUCTS. Micro Clutch and Micro Brake FORM NO. L J-0110

Material Safety Data Sheet. : Crude Palm Kernel Olein

User Guide M Rev A 09/15

JOINT RESTRAINT PRODUCTS & ACCESSORIES

Wash Down Duty Non-Contact Sensor

MASTER. Installation and Operation Manual. Water Conditioning Corp. DECHLOR Series Flow-Through Residential Carbon Filters.

TERMS AND CONDITIONS: (Stated in U.S. Dollars):

User s Guide RC-3 REMOTE VOLUME CONTROL.

FLOODGATE DIMENSION CHART ( WALL MOUNT) HEAD SIZE FLANGE BOLT REQUIRED APPROX RAISE HOLE (NB) DIA CENTRES TO OPEN WEIGHT KG BY

RL4050LS. Electronic Load Shackle. Installation Guide

Ordering & Shipping SECTION IN THIS SECTION: GENERAL INFO ORDERING INFO SHIPPING PAYMENT METHODS RETURN POLICIES

Kennedy Valve. A Division of McWane, Inc. AWWA PRODUCTS

Glass for decoration FOCUS ON COPPER-FREE MIRROR NEW GENERATION MIRROR

Switch-Tek. LV41 & LV42 Series Manual. Sump Float Level Switches

MASTER. Water Conditioning Corp. OPERATION MANUAL. PURO PRO 1200 SCP Series Modular Reverse Osmosis System. January 2012 Version

RACK HAT / STRIP DOOR

SHCM SHOWER COLUMN INSTALLATION INSTRUCTIONS

Advancing Rainwater Drainage Systems by Fast Flow Design

OEM Policy. Information for Original Equipment Manufacturers

SERIES COOLING TOWER. SINGLE-CELL UP TO 6000m 3 /HR FLOW RATE. Large Counterflow Engineered Design FIBREGLASS WOOD STEEL CONCRETE

Vendor Partnership Manual. Section 3 Terms & Conditions of Purchase Order

Price Book Calypso. collection

FORM HEADWALL. FORM HEADWALL (floating) (floating) Installation Manual

CDM Network Programmer for CCT100x

Model # 922-S4. 12/18/2013 Page 1 of 8

L505 VISUAL LEVEL INDICATOR. Dip-Tape Visual Level Indicator INSTALLATION AND OPERATIONS MANUAL

Ergonomic Kneeling Chair

Channel Drains Barrier Free ADA Compliant NEW & IMPROVED DESIGN FOR EASIER INSTALLATION IAPMO LISTED. PRODUCT GUIDE: suggested list price book

Miniature Helium Purifier and Nitrogen Purifier Instruction Manual

drains&accessories d m

SIEMEX OIL SEPARATOR MAINTAINANCE MANUAL SIEMEX OIL SEPARATOR MAINTAINANCE MANUAL. SIEMEX (M) Sdn Bhd

SGLP-RO. Installation and Operating Instructions for SCALEGARD TM LP REVERSE OSMOSIS FILTRATION SYSTEM. 3M TM Water Filtration Products

Cargo Loss and Damage Claims

ITDG Independent Tire Dealers Group. Volume Bonus Program. (Revised 3/27/2012)

Ecologix Environmental Systems, LLC

The Netherlands Tel: Tel: +1 (678) Tel: Tel: +61 (0)

481 MUNN RD SUITE 300 FORT MILL, SC U.S.A. TELEPHONE FAX

Model 292A. Surface Resistance Test Kit. Instruction Manual

ViZion Wireless Monitoring System Instructions

INSTALLATION MANUAL. Guardian Series. QSUS 18 x 40. Manual

MASTER. Water Conditioning Corp. OPERATION MANUAL. PURO PRO 1200 SC Series Modular Reverse Osmosis System. January 2012 Version

Low-Level Design Validation and Testing

SERIES G1A, G1B & G1C SLIDE GATES

10810 W. LITTLE YORK RD. #130 HOUSTON TX VOICE (713) FAX (713) web: IMPORTANT!!!

Instruction Manual TWO MAN QUAD POD ACCESSORY KIT FSGWSF2017. Compatible with FSGWSF2016, not compatible with other models.

Esco Purchase Order Terms And Conditions

DS-520 Digital Indicator Operation Manual 73366

The Culligan Hi-Flo 50 Series Industrial Water Filter System

Vinyl Click Flooring Limited Warranty

Customer Information Sheet

FPF-P 2045 FLAT TOP CHAIN CONVEYOR

Wholesale Terms of Sale

Mutoh. Avery Dennison - Graphics Solutions ICS Performance Guarantee (Terms & Conditions)


INSPECTION CHAMBERS & BACKWATER VALVES

OM-90 SERIES Portable Temperature and Humidity Data Loggers. Shop online at omega.com

SECTION 5 E-Treat Water Conditioning Systems

MAINTENANCE AGREEMENT FOR RSA PRODUCTS ***IMPORTANT***

All Electric Servo Drive Injection Molding Machine J220ADS J280ADS J350ADS J450ADS. Model. Shanghai Hanau(Germany) Hong Kong Lyon Barcelona

FORM HEADWALL. FORM HEADWALL (floor mount) (floor mount) Installation Manual

Credit Application. JMF Company and Subsidiaries nd St. Ct. Fax: (563)

PRODUCT CATALOGUE for CO2 Capture / Recovery Process

Transcription:

CONTENTS Wet Scubber Features 3 Parts 4 Models 6 Technical Specification - MiniLab 7 - MaxiLab 1000 8 - MaxiLab 2000 9 Warranty 10 2

Wet Scrubber Features Wet scrubbers are designed to remove water-soluble compounds from exhaust streams. Advancelab manufactures two types: MiniLab - a closed system comprising of a scrubber unit mounted above the fume hood and a holding tank below MaxiLab - a stand-alone unit that can be remotely located MiniLab can be utilised for individual hoods only. They allow flexibility and are convenient to install. MaxiLab can be used for a series of hoods and are available in two sizes for this application. Units can be manufactured in PVC or PP sheet utilizing hot weld fabrication. All units come with a chemical resistant pump, sanitary and water connections and a skid tray where specified. 3

Demister Auto water top-up Chemical resistant pump 4

Full cone nozzles PP injection moulded balls for high surface area to volume ratios Quality fittings 5

Models MODEL MINILAB MAXILAB 1000 MAXILAB 2000 2 part system Stand alone Stand alone Description Mini Scrubber (above hood) Holding Tank (in base cabinet) Dimensions, mm (L x D x H) Construction Srubbing Media Mini Scrubber 600mm x 600mm x 800mm Holding Tank 1000mm x 500mm x 500mm PVC or PP using hot melt fabrication techniques 700mm x 700mm x 1500mm Excluding skid and plumbing connections 900mm x 900mm x 1800mm Excluding skid and plumbing connections Tellerettes Tower Packing - has a unique patented toroidal helix design that makes them dramatically more efficient than conventional packings in a wide range of mass transfer and particulate collections applications High solid particle loading Constantly renews and exposes liquid to the gas flow High efficiency Injection moulded Polypropylene Mist Eliminators Viewing Windows Chemical Pump Duct Connections Advancelab mist eliminators remove liquid entrainment from gas streams, providing high efficiency and low-pressure drops 1 Included 250 mm 2 2 250 mm Please advise factory Upgrades available include: On-line ph apparatus Mixers Dosing pumps Remote control panels Buliding Management system tie in Maintenance programmes, please check with factory or local distributor 6

MiniLab 570 1 680 2 3 500 300 1. Mini Scrubber (Spray Module) 2. Holding Tank 3. Chemical Pump 7

MaxiLab 1000 1. 25mm Dia PVC Pipe 2. Tellerette Scrubbing Media 3. Viewing Glass (Opening for Adjusting the Float) 4. 15mm Dia Incoming Water Supply 5. Water Float 6. Chemical Water Pump 7. 2 Thk Mist Eliminator 8. Opening for Changing Scrubbing Media 9. Holding Tank 10. Exhaust Outlet 11. 40mm Dia Discharge with a Ball Valve 12. PP Tray 13. Overflow Pipe Front View Side View 700 400 700 400 280 7 2 1 8 1500 1220 9 3 10 4 5 13 11 6 12 8

MaxiLab 2000 1. 25mm Dia PVC Pipe 2. Tellerette Scrubbing Media 3. Viewing Glass (Opening for Adjusting the Float) 4. 15mm Dia Incoming Water Supply 5. Water Float 6. Chemical Water Pump 7. 2 Thk Mist Eliminator 8. Opening for Changing Scrubbing Media 9. Holding Tank 10. Exhaust Outlet 11. 40mm Dia Discharge with a Ball Valve 12. PP Tray 13. Overflow Pipe Front View Side View 900 400 900 600 7 2 1 1800 8 9 3 10 4 5 13 11 6 12 9

Warranty Products Manufactured by Advancelab: Advancelab(S) Pte.Ltd., warrants products that it manufactures to be free from defects for a period of 12 months for parts, commencing from the date of shipment. Advancelab s sole responsibility is to repair or replace, at its option, any part of the product that proves defective or malfunctioning during this time limit. This warranty is void if the equipment is abused or modified by the customer, is operated outside Advancelab s operating instructions or specifications, or is used in any application other than that for which it is specified. This warranty does not include routine maintenance or service procedures, breakage, shipping damage, nor damage from misuse, intentional or unintentional abuse, neglect, natural disasters, or acts of God. Freight Shortage or Damage: Upon receipt of any equipment from Advancelab, customer shall immediately unpack and inspect for damage or shortage. The customer shall not accept a damaged package or a short shipment until the carrier makes a "damage or shortage" notation on both the carrier's and customer's copy of the freight bill or delivery receipt. Service title passes when the shipment is loaded, so customer is responsible for filing and collecting a freight claim. Any replacement products must be ordered and paid for separately. Generally, customers can improve the chance of collecting on a freight claim by following these procedures: 1. Formally requesting that the carrier inspect the shipment immediately upon suspecting damage or shortage to verify condition. 2. Notifying the carrier upon discovery of concealed damage and requesting an inspection within 15 days of receipt, both in person or phone and following up via mail. 3. Keeping the shipment as intact as possible, including retaining original packaging materials and keeping the product as close to the original receiving location as possible. 4. Holding salvage for disposition by the carrier. All Claims: Advancelab (S) Pte.Ltd., expressly disclaims all other warranties, expressed or implied or implied by statute, including the warranties of merchantability or fitness for intended use. Advancelab is not responsible for consequential or incidental damages arising out of the purchase or use of the products supplied by Advancelab. Advancelab is not liable for damage to facilities, other equipment, products, property or personnel of others, or of their agents, suppliers, or affiliated parties, which is caused or alleged to have been caused by products supplied by Advancelab. In any event or series of events, Advancelab s total liability for any and all damages whatsoever is limited to the lesser of the actual damages or the original invoice cost of the items alleged to have caused the damage. The customer s sole and exclusive remedy for any cause of action whatsoever is repair or replacement of the non-conforming products or refund of the actual purchase price, at the sole option of Advancelab. All claims must be made in writing within 90 days of the date the product was shipped. Any claims not made within this time limit shall be deemed waived by the customer. Advancelab is not responsible for any additional costs of repair caused by poor packaging or in-shipment damage during return. Warranty Returns: All warranty returns must be authorized in advance by Advancelab and approved by writing. Unless approved in advance for good reason, all returns must be in original condition, including all manuals, and must be packaged in original packaging materials. All returned goods are to be shipped to Advancelab, freight prepaid at customer s expense. 10

AdvanceLab has built a rock steady reputation for solutions where most fail. Since our establishment in 2003, we have positioned ourselves as the premier facility solution provider for the scientific industry; designing, building and delivering quickly and without fuss. We have also taken our brand of expertise globally; now with exports of laboratory casework, fume hoods, laminar flow cabinets and clean booths heading to 30 countries, covering all continents. Indonesia PT. Advancelab Saintifik Jl. Boulevard Raya Blok QJ 5 No. 23 Kelapa Gading, Jakarta Utara, Indonesia Tel: +6221 45854570 Fax: +6221 45854570 Email: info-id@advancelab-global.com Website: Malaysia Advancelab Sdn Bhd KL Office: Unit B-1-10, Block B, No. 2, Jalan PJU 1A/7A, Oasis Square, Ara Damansara, 47301 Petaling Jaya, Selangor Darul Ehsan, Malaysia. Tel: +603 7831 0188 Fax: +603 78310588 Email: info-my@advancelab-global.com Website: Johor Factory: No. 3388, Jalan Pekeliling Tanjung 27/2, Kawasan Perindustrian Indahpura, 81000 Kulaijaya, Johor, Malaysia. Tel: +607 660 8877 Fax: +607 660 8866 Email: info-my@advancelab-global.com Website: Myanmar Advancelab Scientific & Engineering Co., Ltd No(81/2), 7th Street, Than Thu Mar Road, (14/1)Quarter, South Okkalapa Township, Yangon, Myanmar. Tel: +95 (1) 572393 Fax: +95 (1) 572393 Email: info-mm@advancelab-global.com Website: Singapore Advancelab (S) Pte Ltd No.52 Senang Crescent, Singapore 416619 Tel: +65 6448 8255 Fax: +65 6448 9833 Email: info@advancelab.com.sg Website: Thailand Advancelab (Thailand) Co., Ltd. 9/28, Village No 13, Bang Ramat Sub-district, Taling Chan District, Bangkok Metropolis, Thailand Tel: +65 6448 8255 Fax: +65 6448 9833 Email: info-th@advancelab-global.com Website: Indonesia Malaysia Myanmar Philippines Singapore Thailand