Application Manual ProteoSpin Abundant Serum Protein Depletion Kit

Similar documents
ProteoSpin Urine Protein Concentration Maxi Kit Product # 21600

Kit Specifications 45 g. 45 g of RNA 8 L

Plant/Fungi Total RNA Purification Kit Product # 25800, 31350, 25850

Product # Specifications. Kit Specifications Maximum Column Binding Capacity (gdna) Maximum Column Loading Volume.

RNA Clean-Up and Concentration Kit Product # 23600, 43200

Size-Select Kit for NGS Library Preparation Product # 53600

Average Yields* Yeast DNA Yeast RNA Time to Complete 10 Purifications * Yield will vary depending on the type of sample processed

Kit Components Product # (50 samples) Wash Solution A Elution Buffer B

Cytoplasmic & Nuclear RNA Purification Kit Product # 21000, 37400

Specifications. Kit Specifications. Alcohol Precipitation: Up to 100 ml Column Purification: Up to 5 ml Column Binding Capacity 25 µg

Norgen Gel Extraction Kit. Norgen PCR Purification Kit. Norgen Plasmid MiniPrep Kit

Plasma/Serum RNA/DNA Purification Mini Kit Product# 55200

# , , T)

Product # (12 samples) Solution WN. Elution Buffer B Proteinase K Maxi Spin Columns 12 Collection Tubes 12 Elution Tubes 12 Product Insert 1

Product # 24700, 24750

Urine Protein Concentration, Preservation and Isolation Kit 25 Individual Devices Product Insert Product #: 38200

PROCEDURE FOR USE NICKEL NTA Magnetic Agarose Beads (5%)

EPIGENTEK. EpiQuik Chromatin Immunoprecipitation Kit. Base Catalog # P-2002 PLEASE READ THIS ENTIRE USER GUIDE BEFORE USE

Product # Specifications. Kit Specifications Maximum DNA Input. 200 g Maximum DNA Volume Input Final Endotoxin Levels

Clostridium difficile PCR Detection Kit Product # 37100

Sin Nombre Virus RT-PCR Detection Kit Product #51900

E.Z.N.A. Blood DNA Mini Kit. D preps D preps D preps

Kit Descriptions and Components Mini Kit (Cat.# 56600) Maxi Kit (Cat.# 56800) Number of Preps 50 preps 20 preps 10 preps

DNA isolation from tissue DNA isolation from eukaryotic cells (max. 5 x 106 cells) DNA isolation from paraffin embedded tissue

IMMUNOPRECIPITATION TROUBLESHOOTING TIPS

Product # (10 preps) Lysis Additive A Binding Buffer I. Elution Buffer B

Nickel-NTA Agarose Suspension

E.Z.N.A. MicroElute Genomic DNA Kit. D preps D preps D preps

Fast and reliable purification of up to 100 µg of transfection-grade plasmid DNA using a spin-column.

Urine DNA Isolation Maxi Kit (Slurry Format) Product # 50100

1 ml gel corresponds to ml of 75% (v/v) Glutathione Agarose suspension.

E.Z.N.A. Blood DNA Maxi Kit. D preps D preps

Product # Kit Specification. Kit Specifications Maximum Column Binding Capacity 50 µg Maximum Column Loading Volume 650 µl

E.Z.N.A. Yeast Plasmid Mini Kit. D preps D preps

Lysis Buffer A Wash Solution A Elution Buffer B Mini Filter Spin Columns 50 Collection Tubes 50 Elution tubes (1.7 ml) 100 Product Insert 1

Cells and Tissue DNA Isolation Kit (Magnetic Bead System) 50 Preps Product # 59100

AFFINITY HIS-TAG PURIFICATION

Efficient Multi-Well Protein Purification Strategies

Quick and easy 7 minute protocol to select for 300 bp, 200 bp, 150 bp, 100 bp, 50 bp DNA fragments or perform a double size selection

AFFINITY HIS-TAG PURIFICATION

PureSpin DNA Clean Up Kit

Urine - Based EBV PCR Detection Kit Product # 41100

Jan 25, 05 His Bind Kit (Novagen)

Cells and Tissue DNA Isolation 96-Well Kit (Magnetic Bead System) Product # 62500

Presto Stool DNA Extraction Kit

SurePrep Soil DNA Isolation Kit

Capture of mouse monoclonal antibodies

TIANamp Marine Animals DNA Kit

Strep-Tactin XT Spin Column

DNA Visualizer Extraction Kit

GST Fusion Protein Purification Kit

PureSpin. Gel DNA Purification Kit. Micro Columns INSTRUCTION MANUAL. KIT COMPONENTS For Research Use Only. PureSpin.

E.Z.N.A. mirna Kit. R preps R preps R preps

Protein G HP SpinTrap / Ab Spin Trap

INSTRUCTIONS The resins are adapted to work mainly in native conditions like denaturing.

SERVA Ni-NTA Magnetic Beads

INDEX KIT COMPONENTS 1 STORAGE AND STABILITY 1 INTRODUCTION 1 BENEFITS

Protein Techniques 1 APPENDIX TO CHAPTER 5

Ni-NTA Agarose. User Manual. 320 Harbor Way South San Francisco, CA Phone: 1 (888) MCLAB-88 Fax: 1 (650)

AFFINITY GST PURIFICATION

mdi Micro Gel Extraction Kit User Guide ADVANCED MICRODEVICES PVT. LTD. Membrane Technologies 21, Industrial Area, Ambala Cantt (INDIA)

E.Z.N.A. Stool DNA Kit. D preps D preps D preps

AFFINITY HIS-TAG PURIFICATION

Wearing gloves is highly recommended when handling the kit contents.

ReliaPrep gdna Tissue Miniprep System

1. Cross-linking and cell harvesting

NoviPure Microbial Protein Kit (50)

E.Z.N.A. PF Micro RNA Kit. R preps R preps

E.Z.N.A. Stool DNA Kit. D preps D preps D preps

Milk Streptococcus agalactiae PCR Detection Kit Product # 30600

TIANgel Mini DNA Purification Kit

Presto Soil DNA Extraction Kit

Presto Mini gdna Bacteria Kit

1. Connect the column to the chromatography system, syringe or pump.

Total RNA Purification Micro Kit Product # 35300

For Research Use Only Ver

SurePrep Nuclear or Cytoplasmic RNA Purification Kit

Index 1. Product Description 2. Purification Procedure 3. Troubleshooting 4. Ordering Information

Plasma-Serum EBV PCR Detection Kit Product 41000

E.Z.N.A. Water DNA Kit. D preps D preps D preps

foodproof Sample Preparation Kit III

HiPer Gel Extraction Teaching Kit (Column Based)

Protein A HP SpinTrap

GenElute Total RNA Purification Kit. Catalog number RNB100

Seize X Protein G Immunoprecipitation Kit

Immunoaffinity Chromatography

ab Histone Extraction Kit Rapid / Ultra-pure

3. Close the bottom end of the column and apply the packing device on top. Pump water through the upper adaptor to remove air.

mdi Gel Extraction Kit User Guide ADVANCED MICRODEVICES PVT. LTD. Membrane Technologies 21, Industrial Area, Ambala Cantt (INDIA)

ab ChIP Kit Magnetic One-Step

IMMUNOPRECIPITATION (IP)

ab DNA Isolation Kit - Plasma/Serum

FastPure Spin Columns (Mini and Midi)

Urine DNA Isolation 96-Well Kit (Slurry Format) Product # 27100

Spin Micro DNA Extraction Kit

ProteoMiner Protein Enrichment Technology

E.Z.N.A. Bacterial RNA Kit. R preps R preps

Ion exchange chromatography

Manual innuprep Micro RNA Kit

EPIGENTEK. EpiQuik Histone Demethylase LSD1 Activity/Inhibition Assay Kit. Base Catalog # P-3076 PLEASE READ THIS ENTIRE USER GUIDE BEFORE USE

Transcription:

Application Manual ProteoSpin Abundant Serum Protein Depletion Kit For Use with P/N 17300

ProteoSpin Abundant Serum Protein Depletion Kit Basic Features Efficient removal of highly abundant proteins 1 Benefits The kit depletes 70% of albumin, 90% of α-antitrypsin, and 50% of transferin and haptoglobin, enabling the visualization of low abundance proteins. Depleted serum profile on 2D is clean and smearless with enrichment of some minor spots. Fast and easy processing Does not rely on antibodies Complete kit Efficiently process up to 10 samples in less than 30 minutes using an easy-to-use protocol. Based on an ion exchange mechanism, the kit can be applied to serum and plasma samples from a range of sources, including human and various animals. All columns and solutions required are provided. Low price per column Depletion of proteins and salts Compared to columns based on antibodies, these ionexchange columns are much lower in price, yet perform to the same high standards. Most proteins bind to the column, while salts and many of the major proteins are removed in the flowthrough Suitable for downstream applications Final elution suitable for: SDS-PAGE 2D gel electrophoresis LC/MS Microarrays 2

General Introduction The use of body fluids, including serum and plasma, has become widespread in the area of diagnostics and potential disease marker discovery. The main problem associated with the use of serum and plasma for disease marker identification is the large amount of proteins present, and the enormous range of concentrations of these proteins. Some serum proteins, including albumin and γ-globulins, can constitute up to 70-80% of the total serum proteins present. The high abundance of these serum proteins can result in masking the detection and analysis of less abundant proteins. Thus there is a need to remove as many of these high abundance proteins as possible, in order to be able to analyze the lower abundance proteins of interest. 2 The ProteoSpin Abundant Serum Protein Depletion Kit provides a fast and simple procedure for the effective depletion of major serum proteins including albumin, α- antitrypsin, transferin and haptoglobin from serum and plasma samples. The kit is unique in that it is based on an ion-exchange mechanism and not the use of specific antibodies. As a result, the kit can be used to deplete serum proteins from a wide variety of samples, including human and various animals. Albumin has been found to be depleted by 70%, transferin and haptoglobin by 50% and α-antitrypsin by 90%. The complexity of the sample is thus greatly reduced, allowing for the detection of less abundant proteins present in the sample. Eluted samples are ready for use in various downstream applications including 2D gel electrophoresis, LC/MS and microarrays. 3

General Introduction The ProteoSpin Abundant Serum Protein Depletion Kit employs an innovative separation material, silicon carbide (SiC). This proprietary processed material acts as an ion exchanger, and is able to remove the high abundance proteins present in serum and plasma based on their pis. Most of the high abundance proteins do not bind to the column due to their pis, and thus are eliminated in the flowthrough from the binding step. The majority of lower abundance proteins are able to bind to the column, and therefore remain in the sample. This prepares an enriched serum or plasma sample that is ready for downstream applications. 4

General Introduction Ion Exchange Chromatography In ion exchange chromatography, ions that are electrostatically bound to an insoluble and chemically inert matrix are reversibly replaced by ions in solution. The matrix can be either an anion exchanger that consists of positively charged groups that reversibly bind anions in solution, or it can be a cation exchanger that bears negatively charged groups and binds to mobile cations. Proteins are complex molecules that carry both positive and negative charges, depending on their amino acid composition and the ph of their solutions. In this case, any given protein will bind to both anion and cation exchangers depending on the net charge of the protein. When purifying a protein, the mobile phase ph, salt concentration and buffer are chosen to bind the desired protein on the selected ion exchanger. The impure protein solution is applied to a column that contains the ion exchanger, and is washed with the same mobile phase solution. Proteins bind to the matrix and are eluted by changing either salt concentration or ph. 5

General Introduction Silicon Carbide as an Ion Exchanger The chromatographic resin used in the ProteoSpin Abundant Serum Protein Depletion Kit consists of silicon carbide (SiC), a man-made material noted for its hardness (second only to diamond) and high resistance to chemical change. These properties make SiC highly suitable for spin column chromatography even at extremes of ph. When processed appropriately, SiC becomes an effective cation exchanger for the purpose of purifying macromolecules. The surface of SiC is negatively charged and can bind positively charged macromolecules. SiC has poor affinity to monovalent and divalent cations, also making it an effective resin for the removal of salts. Soluble proteins bind to SiC through interaction of the positively charged side-groups on their chain with the negative charges on the SiC surface. As a cation exchanger, SiC has an estimated effective pk a 2 making the resin negatively charged over a wide range of ph. Therefore, with the exception of those peptides that are highly acidic, most soluble polypeptides can be bound to SiC. 6

ProteoSpin Serum Depletion Kit ProteoSpin Abundant Serum Protein Depletion Kit Components Column Activation and Wash Buffer Elution Buffer Neutralizer ProteoSpin SiC Spin Columns inserted into 2 ml collection tubes Final Collection Tube, 1.7 ml ProteoSpin Abundant Serum Protein Depletion Kit Application Manual ProteoSpin Abundant Serum Protein Depletion Kit Protocol Card Recommended Storage Conditions For unopened solution containers, the reagents should remain stable for at least one year when stored at room temperature. Once opened, the solution should be stored at 4 C when not in use. Customer-Supplied Reagents and Equipment You must have the following in order to use the Proteospin Abundant Serum Protein Depletion Kit: Benchtop microcentrifuge Micropipettors 7

ProteoSpin Serum Depletion Kit Procedure This section describes the procedure associated with the Proteospin Abundant Serum Protein Depletion Kit. Typical Procedure: The kit utilizes spin columns containing SiC, an ion-exchanger that binds the protein of interest if it retains a net positive charge at the binding ph of 6.5. All the main high abundance proteins will not bind to the column at this ph due to their pis, and thus will be eliminated in the flowthrough. The majority of low abundance serum proteins will bind to the column at this ph, and will become enriched in the serum sample upon elution. These depleted serum samples are then ready for downstream analysis. Each spin column is able to deplete up to 500 µg of serum proteins. This kit provides a fast and simple procedure for the effective depletion of major serum proteins including albumin, transferin, haptoglobin and α-antitrypsin, from serum and plasma samples. The kit is unique in that it is based on an ion-exchange mechanism and not the use of specific antibodies. As a result, the kit can be used to deplete serum proteins from a wide variety of samples, including human and various animals. 8

ProteoSpin Serum Depletion Kit Protocol The following procedure describes the depletion of albumin and other high abundance serum proteins from small serum and plasma samples. Note: All centrifugation steps in these procedures are carried out at 6,700 x g in a microcentrifuge. Performance of the kit is not affected by temperature, and thus the procedure may be performed at room temperature, 4 C, or on ice. A. Column Activation 1. 2. 3. 4. Open the cap on the pre-assembled spin column with its 2 ml collection tube. Add 500 µl of Column Activation and Wash Buffer to the column and close the cap. Centrifuge for one minute, and discard the flowthrough. Repeat steps 2 and 3 to complete the column activation step. 9

ProteoSpin Serum Depletion Kit B. Sample Preparation It is important that the serum sample be properly prepared before loading it onto the column. 1. Dilute 10 µl of the serum sample in 490 µl of Column Activation and Wash Buffer. Mix well. C. Protein Binding During the binding step, the protein solution is passed through the resin bed aided by centrifugation. The high abundance proteins will pass through the column into the flowthrough, while the lower abundance proteins are captured on the resin. 1. 2. Apply the 500 µl of diluted serum sample onto the activated column and centrifuge for one minute. Discard the flowthrough. Reassemble the spin column with its collection tube. Note: You can save the flowthrough in a fresh tube for assessing albumin and high abundance protein depletion. 10

ProteoSpin Serum Depletion Kit D. Column Wash This step removes non-specifically bound debris from the column. 1. 2. 3. 4. Apply 500 µl of Column Activation and Wash Buffer to the column and centrifuge for one minute. Discard the flowthrough and reassemble the spin column with its collection tube. Add another 500 µl of Column Activation and Wash Buffer to the column and centrifuge for one minute. Inspect the column and ensure that the liquid has passed through into the collection tube. There should be no liquid in the column. If necessary, spin for an additional minute to dry. 11

ProteoSpin Serum Depletion Kit E. Protein Elution and ph Adjustment The supplied Elution Buffer consists of 10 mm sodium phosphate ph 12. It is necessary to adjust the ph of the eluted serum sample to neutral by pre-adding Neutralizer to the elution tube. This step is necessary before running downstream applications including 2D gel electrophoresis. 1. 2. 3. 4. Add 5 µl of Neutralizer to a fresh 1.7 ml microcentrifuge tube. Transfer the spin column from the Column Wash procedure into the microcentrifuge tube. Apply 100 µl of the Elution Buffer to the column and centrifuge for one minute to elute bound protein. Add another 100 µl of Elution Buffer and centrifuge for one minute into the same microcentrifuge tube. Note: Approximately 70% of albumin, 90% of α-antitrypsin, and 50% of transferin and haptoglobin are depleted from the serum sample at this point. Serum samples are now ready for downstream applications. 12

Frequently Asked Questions and Troubleshooting A 1. What is the black powder that is packed into the spin columns? The black chromatography material is silicon carbide (SiC). It is processed using proprietary methods to function as an ion exchange chromatography resin. 2. How does the kit deplete albumin and other high abundance proteins from serum and plasma? The depletion of the major proteins in the serum is based mainly on their pi values. The column binding ph used in this kit depletes most of the major proteins in the flowthrough and retains many of the minor proteins. 3. What high abundance serum proteins can be depleted using this kit? The Proteospin Abundant Serum Protein Depletion Kit allows for the efficient removal of albumin, α-antitrypsin, transferin and haptoglobin. 13

Frequently Asked Questions and Troubleshooting 4. Can the columns be re-used? The columns are designed for single use only. This minimizes sample carryover. 5. How should I store the Proteospin Abundant Serum Protein Depletion Kit solutions? Once opened, the solution containers should be stored at 4 C when not in use. If unopened, the solution containers can be stored at room temperature. 6. What are the maximum and minimum loads for binding sample volumes that I can load onto the column? We recommend that no more than 500 µl of sample be loaded onto the column, to ensure that the bottom of the column does not rest in the flowthrough that is caught in the collection tube. The minimum load should be at least 100 µl to completely cover the resin bed. 7. What are the maximum and minimum amounts of protein that I can load onto the column? We recommend that between 300 and 500 µg of protein be loaded onto the column, or approximately 10 µl of serum, in order to obtain optimal depletion. 14

Frequently Asked Questions and Troubleshooting 8. What are the highest and lowest recommended column microcentrifuge speeds? We recommend a maximum speed of 6,700 x g be used to spin the columns. Speeds below 6,700 x g may be insufficient to completely move the liquid phase through the resin bed. Additional spinning times may be required to remove this liquid. 9. What is the typical amount of high abundance protein depletion that I can expect with the Proteospin Abundant Serum Protein Depletion Kit columns? Approximately 70% of albumin, 90% of α-antitrypsin, and 50% of transferin and haptoglobin are depleted from the serum sample using the Proteospin kit and columns. 10. Can I autoclave the columns? No. The columns are not designed to be autoclaved as it would cause the plastic in the columns to wrinkle. 11. How can I assess the depletion of albumin and other major serum proteins from my sample? Save the flowthrough from the binding step and perform a colorimetric protein assay to determine the amount of protein present. This sample can be run on a 1D or 2D gel to determine the specific proteins that have been depleted. 15

Frequently Asked Questions and Troubleshooting 12. I use a colorimetric protein assay to determine concentration of eluted proteins. Is there an accurate way of doing it? The colorimetric protein assays available in the market are quite accurate, however, there are a number of ways to improve them. First, using a linear regression to fit the points for the standard curve is often less accurate than using a second-degree polynomial. Microsoft Excel has full features for curve fitting. The goodness-offit for the regression should determine whether first-degree (linear) or seconddegree polynomial would be used. Second, the protein used as the standard should closely match the dye-binding characteristics of the protein of interest. For example, using BSA as a standard to determine concentrations of immunoglobulins may provide erroneous results. This is because immunoglobulins do not bind some dyes efficiently. Third, ensure that the protein standard (and standard curve) is in a solution that resembles the solution of the test protein. Sometimes buffer constituents can have drastic effects on dye binding properties. 16

Troubleshooting Guide B Each of the following tables discusses a problem which can occur, its possible causes, and presents solutions and explanations. Problem: Protein Solution Does Not Flow Through the Column Possible Causes Centrifugation speed was too low. Inadequate spin time. Protein solution is too viscous. Cellular debris is present in protein solution. Solution & Explanation Check the centrifuge to ensure that it is capable of generating 6,700 g. Sufficient centrifugal force is required to move the liquid phase through the resin. Spin an additional minute to ensure that the liquid is able to flow completely through the column. Dilute protein solution as described in protocol. Filter the sample in a 0.45 µm filter or spin down insoluble materials and transfer liquid portion to the column. Solid, insoluble materials can cause severe clogging problems. 17

Troubleshooting Guide Problem: Eluted Protein is Degraded Possible Causes Eluted protein solution was not neutralized. Eluted protein solution was not neutralized quickly enough. Proteases may be present. Bacterial contamination of the protein solution. Solution & Explanation Add 5 µl of Neutralizer to each 200 µl of eluted protein in order to adjust the ph to neutral. Some proteins are sensitive to high ph, such as the elution buffer at ph 12.5. If eluted protein is not used immediately, degradation will occur. We strongly suggest adding Neutralizer in order to lower the ph. Use protease inhibitors during all steps of sample preparation, and during storage of the serum, if desired. Prepare the protein samples with 0.015 % sodium azide. The Elution Buffer already contains sodium azide. Problem: Insufficient Depletion of Major Proteins Possible Causes Column was overloaded with proteins. Improper sample preparation. Solution & Explanation Decrease the amount of serum that is loaded onto the column. Ensure that the serum sample is properly prepared by diluting it in the provided Column Activation and Wash Buffer. 18

Troubleshooting Guide Problem: Low Protein Concentration in the Elution Possible Causes Low levels of serum proteins present in the initial sample. Solution & Explanation Increase the amount of serum that is loaded onto the column. The input amount can be verified using a reliable colorimetric assay. 19