EFFICIENT SOLAR COOLING

Similar documents
PERFORMANCE OF SOLAR AIR-CONDITIONING SYSTEM USING HEAT PIPE EVACUATED TUBE COLLECTOR. M. Moorthy

AR No. # - Solar Thermal

Renewable Energy Based Active Cooling System

Optimisation and Cost Analysis of a Lithium Bromide Absorption Solar Cooling System

ISSN: ISO 9001:2008 Certified International Journal of Engineering and Innovative Technology (IJEIT) Volume 4, Issue 3, September 2014

AR No. # Solar Thermal. Assessment Recommendation Savings Summary Source. Cost Savings Natural Gas. $984 * 1 MMBtu = 1,000,000 Btu

SOLAR ENGINEERING OF THERMAL PROCESSES

An Efficient Solar Thermal-Powered Evaporation System for Salt Harvesting and Wastewater Treatment

Chromasun Micro-Concentrator

Available online at ScienceDirect. Energy Procedia 91 (2016 ) 20 26

Héctor Rubio Plana Gas Natural, SDG S.A. 18th. June 2009

DESIGN AND MODELING THE Φ-F

An Absorption Chiller in a Micro BCHP Application: Model based Design and Performance Analysis

DUBAL Energy Optimization Absorption Chiller Pilot Project

Modeling and analyzing solar cooling systems in Polysun

Providing free cooling from low temperature waste heat

APPLICATION OF CUSTOMIZED ABSORPTION HEAT PUMPS WITH HEATING CAPACITIES ABOVE 500 kw PROJECT: ACKERMANNBOGEN, MUNICH

SorTech package solution description

Exergy analysis of a flat plate solar collector

Thermal Analysis of Solar Flat Plate Collector

Estimation of Steam Production in a Receiver. Under Solar Concentrating Radiation

Research Article Experimental Study of Thermal Performance of One-Ended Evacuated Tubes for Producing Hot Air

Development of an Innovative 2.5 kw Water- Silica Gel Adsorption Chiller

Performance Evaluation of Solar Parabolic Trough for Cloths Laundry application

EVALUATION OF SOLAR SORPTION REFRIGERATION SYSTEM PERFORMANCE IN LATVIA

Experimental investigation of single-phase and twophase closed thermosyphon solar water heater systems

DEVELOPMENT OF A HIGH EFFICIENCY ABSORPTION CHILLER-HEATER AND A COMPACT ABSORPTION CHILLER-HEATER

Solar Air-Conditioning Systems in small - medium scale applications

Design Optimization of a Non-evacuated CPC Collector

Energy efficiency of a solar domestic hot water system

BUILDING FOR THE FUTURE

Developments in Parabolic Solar Dish Concentrator For Enhanced System Efficiency of Steam Generation

Design of Experiment for Solar Water Heater Performance Analysis

Gas Turbine Inlet Air Cooling System

ACTIVE SOLAR SYSTEMS

The Potential and Challenges of Solar Boosted Heat Pumps for Domestic Hot Water Heating

Solar Absorption Aqua-Ammonia Absorption system simulation base on Climate of Malaysia

STUDY ON A FLAT PLATE SOLAR COLLECTOR

ENERGY EFFICIENT SYSTEMS Recover & recycle your waste heat

Computational Study of Hybrid Water Heater with Evacuated Glass Tube Solar Collector and Rice Husk Combustion

Performance Analysis of Evacuated Tube Heat Pipe Solar Water Heating System using Nanofluid coupled with parabolic Trough Concentrator

Simulation and Optimization of Vacuum Tube Solar Collector Water Heating System in Iran

ENERGY RECOVERY IMPROVEMENT USING ORGANIC RANKINE CYCLE AT COVANTA S HAVERHILL FACILITY

Energy Efficient Solar Milk Chiller

SOLAR COOLING: STATE OF THE ART, TECHNICAL ANALYSIS AND FIRSTS APPLICATIONS

Accepted Manuscript. Authors: L.M. Ayompe, A. Duffy, S.J. McCormack, M. Conlon

Over 3 decades, the company has helped customers to be competitive and earn community goodwill by :

Solar Power Overview. REROC Off the Grid - 14 November 2013 Edwin Foong GM Business Development, SOLEIR

Research Article. An Experimental Study of a Single Surface Solar Water Distiller

PERFORMANCE ANALYSIS OF PARABOLIC TROUGH SOLAR COLLECTOR FOR THREE DIFFERENT FLOW RATES

The Present and Future of Refrigeration, Power Generation and Energy Storage. R.Z. Wang Shanghai Jiao Tong University

Low temperature cogeneration using waste heat from research reactor as a source for heat pump

Experimental Study on Collection Efficiency of Solar Cooking System

EXPERIMENTAL INVESTIGATION ON COUPLING EVACUATED HEAT PIPE COLLECTOR ON SINGLE BASIN SINGLE SLOPE SOLAR STILL PRODUCTIVITY

Digging Deeper SOLAR ENERGY. Forms of Solar Energy

Chapter Six{ TC "Chapter Six" \l 1 } System Simulation

Electrical/thermal performance of hybrid PV/T system in Sharjah, UAE

Intelligent Process Cooling Technology Saves on Water and Energy, Improves Productivity

A novel solar-powered adsorption refrigeration module

Revue des Energies Renouvelables Spécial ICT3-MENA Bou Ismail (2015) Numerical study of a single effect ejector-absorption cooling system

EXPERIMENTATION AND MODELLING OF A SMALL-SCALE ADSORPTION COOLING SYSTEM IN TEMPERATE CLIMATE. July 22, 2013

SOLAR COOLING FOR ENERGY SAVING. CAN WE AFFORD NOT TO USE THE HEAT OF THE SUN?

Chapter 8. Vapor Power Systems

Performance Evaluation of Solar Flat Plate Collector under Climatic Conditions of Islamabad Pakistan

5 / KWh Electricity from Concentrated Solar Power (CSP) Finally a Reality

Reminder: Solar and Terrestrial Radiation

International Research Journal of Engineering and Technology (IRJET) e-issn: Volume: 04 Issue: 04 Apr p-issn:

Effect of Distance between Double Glazing on the Performance of a Solar Thermal Collector Control

Feasibility study of a roof top Solar room heater

Simulation of a solar collector array consisting of two types of solar collectors, with and without convection barrier

and Exergy Analysis of a Typical LiBr/H 2 O VAR

Instytut Fizyki Doświadczalnej Wydział Matematyki, Fizyki i Informatyki UNIWERSYTET GDAŃSKI

Solar Flat Plate Thermal Collector

Evaluation of efficiency and collector time constant of a solar flat plate collector

II. SYSTEM DESCRIPTION AND MATHEMATICAL MODELING

A Study on the Integration of a Novel Absorption Chiller into a Microscale Combined Cooling, Heating, and Power (Micro-CCHP) System

ODA-UNESCO project: Promotion of energy science education for sustainable development in Lao PDR

Southwest Solar Technologies, Inc. ASSETS FOR COLLABORATION IN CONCENTRATING SOLAR Herb Hayden, CTO

Unit 7 Overview of Solar Thermal Applications

Life cycle analysis of thermosyphon solar water heaters

Solar Absorption Chiller Final Report

Performance Assessment of Large Vapor Absorption System

Solar Energy Technologies

Experimental analysis of heat-pump integrated with solar energy

PINCH ANALYSIS: For the Efficient Use of Energy, Water & Hydrogen. PULP AND PAPER INDUSTRY Energy Recovery and Effluent Cooling at a TMP Plant

!"#$%&"#'"$( (% +, -

Master Level Thesis. Thermal Evaluation of a Solarus PV-T collector. European Solar Engineering School No.183, December 2013

Available online at ScienceDirect. Energy Procedia 101 (2016 )

A Software for Performance Simulation of Solar Water Heating Systems

ScienceDirect. Compact hot water storage systems combining copper tube with high conductivity graphite and phase change materials

Application of Near-Optimal Tower Control and Free Cooling on the Condenser Water Side for Optimization of Central Cooling Systems

Available online at ScienceDirect. Energy Procedia 91 (2016 )

Inventaire des installations de climatisation solaires en Europe Inventory of solar cooling installations in Europe

IOP Conference Series: Earth and Environmental Science PAPER OPEN ACCESS

INSIDE: ASHRAE Hall of Fame

Performance of a Solar LiBr - Water Absorption Refrigerating Systems

Performance Evaluation Of Gas Turbine By Reducing The Inlet Air Temperature

ISSN: [Mujawar* et al., 5(12): December, 2016] Impact Factor: 4.116

ENERGY INNOVATIONS SMALL GRANT (EISG) PROGRAM EISG FINAL REPORT

Renewable Energy Systems 10

Transcription:

EFFICIENT SOLAR COOLING Heather Poiry Kevin Balkoski Lun Jiang Roland Winston University of California, Merced 4200 N.Lake Rd, Merced CA 95348 heatherpoiry@gmail.com kbalkoski@gmail.com ljiang2@ucmerced.edu rwinston@ucmerced.edu ABSTRACT In the summer of 2011 a new technology was demonstrated for the first time in a real world setting: an external compound parabolic concentrator powering a double effect absorption chiller. A commercial double-effect hybrid gasfired chiller was run on solar energy operating at temperatures between 150-180 C. Daily solar collector efficiencies, coefficient of performance and system characterization are presented in this paper. It is shown that the double effect absorption chiller can operate with fixed solar thermal collectors effectively. have created a new paradigm in effective solar cooling. That is the subject of this paper. 1.INTRODUCTION Solar cooling has long been a desired goal in utilizing the solar resource for the benefit of people. The reasons are intuitive; the resource is well-matched to the load (high cooling demand days are usually sunny days) and if deployed on a roof, solar radiation that would otherwise heat the building is instead diverted to cool the building.1 However; the technical barriers to implementation are wellknown. Efficient absorption cooling machines (double effect) require relatively high temperatures ~ 180 C. which is well beyond the range of flat plate solar collectors, while tracking collectors are problematic for building applications. Moreover, absorption machines operate in a relatively narrow range of temperature and do not respond well to the natural variability of solar insolation.2 Recently the availability of fixed, high temperature non-imaging collectors, and absorption chillers that are gas/solar hybrids Fig. 1: An XCPC prototype at Castle Air Force Base in Atwater, CA. 2. BACKGROUND 2.1 The solar collector: The collector configuration is an evacuated tube receiver matched to an external non-imaging reflector, typically referred to as an XCPC. Figure 1 is an image of the prototype. The XCPC provides solar concentration without moving parts that can achieve operating temperatures up to 200 C. The design principle maximizes the probability that radiation starting at the receiver would be directed to a specific band in the sky we wish to accept. In our case north-south orientation this band is 120 degrees in 1

azimuth and 180 degrees in elevation. This corresponds to a nominal operational time period of eight hours a day with a concentration ratio of 1.18. The incidence angle modifier, IAM, was measured by positioning the collector due south and tilted to be normal to the sun at solar noon (no tracking) and recording the instantaneous thermal collector efficiency at a collector inlet temperature of 140 C over the course of the day. In this measurement the instantaneous efficiency was based on the total insolation on the collector plane. Figure 2 shows the relative efficiency during the day is substantially constant as the sun angle varies between -51 and +59. The acceptance angle was measured as +/- 55. The test used to determine the IAM chart and the acceptance angle can also be used to understand the collector s all-day performance. During the test, the collector performed within 90% of the nominal efficiency for roughly 7.3 hours. The thermal performance as a function of operating temperature is shown in Figure 3. In the same figure, a selection of other thermal collectors are included, making the point that ours is the only fixed collector operating efficiently at 200 C. Fig. 2: 8 hour IAM performance of the XCPC. Fig. 3: Efficiency of the collector 2

2.2 The Chiller: The cooling machine is a commercial 6.6 U.S. refrigeration ton double-effect lithium bromide chiller. It is a hybrid system that is powered by natural gas or solar thermal energy. To operate on solar energy the chiller requires 21 kwth energy at 175 C. The following description is how this machine works. When liquid evaporates, it absorbs heat from its surroundings. Water boils at 100 C under normal atmospheric pressure (760 mmhg), but it can also boil at very low temperatures under partial vacuum conditions. By creating a vacuum (6 mmhg pressure) in an airtight vessel, water can boil at 4 C. There is a Lithium Bromide, LiBr, solution as the absorbent, water as the refrigerant and natural gas or solar as the heating source. As the LiBr solution is deliquescent water absorbent, it can absorb surrounding vapor and maintain a low pressure condition in the evaporator. Chilled water at 14 C enters the copper tubes inside the evaporator and the refrigerant water at 4 C is sprayed on the outside of the tubes, under partial vacuum. The refrigerant water absorbs heat from the chilled water and evaporates, becomes vapor, thereby the chilled water temperature is reduced to 7 C. Concentrated LiBr solution in the absorber absorbs the refrigerant vapor and then transfers the heat from the vapor to the cooling water. The cooling water heat is released to the ambient air via the cooling tower. The diluted LiBr solution is pumped to the high temperature generator where it is reheated and refrigerant vapor evaporates from the solution making the solution concentrated. The concentrated solution repeats the absorbing process and the refrigerant vapor goes to the condenser where it is condensed and returns to the evaporator to begin the cycle again. Figure 4 shows a LiBr double effect chiller processes. *Orange Liquid is LiBr + H 2 O *Green Liquid is H 2 0 1. High Temperature Generator 2. Low Temperature Generator 3. Condenser 4. Absorber 5. Evaporator Green Loop is cooling water loop (goes to cooling tower) Blue Loop is chilled water loop (goes to house AC system) Purple Loop is hot water loop (goes to house hot water) Fig. 4: Lithium Bromide double effect, gas-solar hybrid system. 3

Fig. 5 The diagram of the System. 3.THE SYSTEM To power the double effect chiller we built a 21 kwth XCPC array, in north south orientation. The collectors are elevated 20 from the horizontal to favor summer operation and are orientated 14 west of south to favor operation later in the afternoon. Figure 5 is a process flow diagram of the solar cooling system. There are three loops in this system, referred to as: oil, glycol and water. The glycol loop was added to avoid potential contamination of the LiBr solution by oil. 4 METHODOLOGY 4.1 Solar Concentrator Performance The instantaneous solar thermal collector output power was calculated by equation 1: (1) The mass flow rate through the solar collectors was measured by a Coriolis flow meter, and the temperature difference is taken with two thermocouples placed at the input and output of the solar collectors. The available solar energy to the solar thermal collector system was calculated by equation 2: (2) There was a precision spectral pyronameter on the collector plane which measures. Knowing this and the aperture area the available power to the solar thermal collector was calculated. The thermal efficiency of the collectors is: (3) The array performance is monitored by total insolation on the plane of the collector which is appropriate for natural variability of solar insolation. This is in contrast to individual collector testing where both direct and diffuse components are measured under stable, high insolation. 4.2 Chiller Performance Conventionally a chiller s effectiveness is characterized by its coefficient of performance, COP. The COP is calculated by the following equation: (4) In our case the power input is the power provided directly by the collectors. This slightly de-rated the chiller performance by lumping in heat dissipation due to the glycol loop and heat exchanger. The power input to the chiller by solar energy is calculated by equation 1.In the natural gas mode the thermal input to the chiller is calculated by metering the natural gas 4

Temperature [C for Collectors and Hx] Temperature [C] for Chiller consumption. 0.6 0.4 0.2 0 Fig. 6: Instantaneous thermal efficiency of the XCPC solar collector. 5 RESULTS AND DISCUSSION 5.1 The Collectors: From Figure 3 we can see that the rated efficiency for the XCPC at an operational temperature of 170 C is 45%, with a direct normal incidence power of 800 W/m^2 and 20% diffuse; however, with this experiment we are calculating our available solar power from global radiance on the plane of the collector, which should yield, according to this model, roughly 35%. Figure 6 shows a daily thermal efficiency during operational temperatures, 180-160 C, which begins at 34% and grows to 40%. The thermal efficiency becomes higher during operation due to the entire system tending towards thermal equilibrium and reducing the heat loss. 1.1 1 0.9 0.8 0.7 0.6 0.5 Thermal Efficiency of XCPC 0.4 12:00:00 PM1:12:00 PM 2:24:00 PM 3:36:00 PM Fig. 7: The COP for the chiller running on solar energy 5.2 The Chiller: COP There are two critical variables to the chiller: The coefficient of performance, COP, and the outlet temperature of the chilled water. The double effect absorption chiller is designed to produce 7 C water at a rated COP of 1.1. The average COP that we measured was.9, and the average outlet temperature of the chilled water was 7 C. Figures 7 and 8 represent this data. This proved to us that the double effect absorption chiller functioned very well with having the solar collectors as the power input Temperature Outlet 200 150 100 50 0 Fig. 8: The temperature outlet of the, solar collectorsred, and the chiller, blue; for an 8 hour day. 5.3 The System: Figure 9 shows that the non-tracking XCPC evacuated solar collector array at Castle Air Force Base provides enough energy for the double effect chiller to operate independent of natural gas. Through all of our experiments it has been observed that once the solar collectors provide enough energy at temperature the natural gas does not need to be turned on until evening. It has also been shown that despite fluctuations with the solar insolation the COP of the chiller is fairly constant. 6 CONCLUSIONS: On May 5th, 2011 the UC Merced solar cooling project was commissioned and by July 12th it became operational. The system starts on natural gas and once the solar reached operating temperature the chiller solely ran on solar energy for the remainder of the day. The chillers power output was consistent and actually attained a higher cop when running on solar. Based on the TMY data at Fresno, we simulated the cost for energy hour by hour as shown in Figure 10. 35 30 25 20 15 10 5 0 5

Fig. 9 System performance Fig. 10 Cost analysis 6

6.ACKNOWLEDGMENTS: This project was supported in part by the California Community Fund and the California Energy Commission. 7.NOMENCLATURE [ ] [ ] Subscripts 8.REFERENCES: (1) Hang, Yin, Ming Qu, and Fu Zhao. "3. Economic and Environmental Assessment of an Optimized Solar Cooling System for a Medium-sized Benchmark Office Building in Los Angeles, California. Renewable Energy 36.1 (2010): 648-58. Print. (2) Duff, W., Roland Winston, Joseph J. Gallagher, James Bergquam, and Thomas Henkel. "Performance of the Sacramento Demonstration ICPC Collector and Double Effect Chiller." Solar Energy 76.1-3 (2004): 175-80. Print. (3) Winston, Roland, Juan C. Miñano, and Pablo Benitez. Nonimaging Optics. Amsterdam: Elsevier, 2008. Print. (4) Rabl, Air. Active Solar Collectors and Their Applications, Oxford University Press 1985 (5) Moran, Michael J., and Howard N. Shapiro. "Coefficient of Performance. Fundamentals of Engineering Thermodynamics. Hoboken, NJ: Wiley, 2008. Print. 7