White Paper HELIAX FXL. Exploding the Myth of Galvanic Corrosion.

Similar documents
Galvanic Corrosion Prevention Guide for Water Cooling Systems

Iron is found in an oxidized state and is mined from the ground as an iron ore.

Light Bases & Light Fixtures

ENGINEERING COMMITTEE Interface Practices Subcommittee AMERICAN NATIONAL STANDARD. ANSI/SCTE (Formerly IPS SP 100)

Metropolitan Water Reclamation District of Greater Chicago 10/19/ Mark Joyce Senior Mechanical Engineer Engineering Department

Electrochemical Considerations

Aluminium Excellence Performance in Economical Way

Galvanic and Stray Current Corrosion

PROF. DR. M.M. B. EL SABBAH AL-AZHAR UNIVERSITY FACULTY OF SCIENCE CHEMISTRY DEPARTMENT

Metal and Non Metals

Prevention Strategies Design and Coatings

a: potential difference before direct current is applied b: potential difference after the application of current

Combinations of alloys and environments subject to dealloying and elements preferentially removed

Introduction. Jeremy Hailey, P.E.

E-Z-Ground Grounding Systems. Ground Wire Size. Water Pipe Size. 1/2 in /4 in. 2 in /2 in. 3-1/2 in TB

Buried Pipe Corrosion in the Power Plant Environment

Features Conductive Room Temperature Cure. Product Ref IP 4525IP Low viscosity adhesive & coating. High thermal conductivity

Effects of Galvanic Corrosion on Au-Sn Plated Contacts in Electronic Cable Interconnect

Why Does Rust Occur? 7.1 IN GENERAL

Determining the Coefficient of Friction. Part by by Ron Kurtus

Dissimilar Metals DISSIMILAR METALS. Weld Tech News VOL 1. NO. 14

TECHNICAL SPECIFICATION Conductive Elastomer Extruded Gaskets

Evaluating the Upset Protrusion Joining (UPJ) Method to Join Magnesium Castings to Dissimilar Metals

CORROSION PHENOMENA AN INTRODUCTION G P Rothwell

VALVES. Hank Litchfield, Regional Director of Commercial/Industrial Product Sales, Nibco Inc., Houston, Texas Zinc, the metallic element popular

AQA GCSE Design and Technology 8552

Distribution Review. Corrosion Control. Corrosion Control Vocabulary. American Water College 1. Corrosion Control Training Objectives

Amphenol RF- SMA Connector Series

A LIGHTWEIGHT SOLUTION FOR SHIELDING AND CONDUCTING

ASTM and the Metals Industry Long-Term Partners for Success

Effect Of Oxidation In Tin Coated Copper Bus Connections

WELDING Topic and Contents Hours Marks

Aluminium as a viable solution for offshore wind turbines. Dr. Simon Jupp Deep Sea Offshore Wind R&D Seminar, 20. January 2011

85 Q.51 Which of the following carbonates would give the metal when heated with carbon? (1) MgCO 3 (2) PbCO 3 (3) K 2 CO 3 (4) CuCO 3

An Introduction to Cathodic Protection Principles

O Coaxial/Fiber/Microduct Hybrid Buried Cable. Serves businesses in a new commercial serving area. Mitigates future cost of fiber installation

NEW! THE FLEXIBLE PROFESSIONAL INSULATION WITH REVOLUTIONARY CHARACTERISTICS. even easier to use

INDUSTRIAL TEMPERATURE SENSORS

Magnesium-Rich Coatings

Copper Tube Folderv3.indd 2 16/5/07 16:27:03

SUB-Programs - Calibration range Fe Base for "PMI-MASTER Pro" Spark - mode Fe 000

TracPipe CounterStrike White Paper. The Best Gets Better: TracPipe CounterStrike. Page 1 of 7. FGP-611G 09/11 Omega Flex Inc.

Drinking Water Corrosion Control and POU/POE Treatment

Advanced Materials and Design for Electromagnetic Interference Shielding

5072 CHEMISTRY (NEW PAPERS WITH SPA) TOPIC 9: METALS 5067 CHEMISTRY (NEW PAPERS WITH PRACTICAL EXAM) TOPIC 9: METALS

STOCK LIST COQUITLAM, BC, CANADA SHEET PLATE COIL PIPE TUBE ROD BAR FITTINGS FLANGES EXTRUSIONS ALUMINUM BRASS BRONZE COPPER COPPER-NICKEL

Reamer & Drill Selection Procedures

Technical Note SALES. Page

REAL METAL COMPOSITE PANEL FAÇADE SOLUTIONS BY NU-CORE

3M Electromagnetic Compatible Products

Copper and other metals used in telecommunications

History of Cable Systems HISTORICAL OVERVIEW OF MEDIUM & HIGH VOLTAGE CABLES. Nigel Hampton

7.3 Bonding in Metals > Chapter 7 Ionic and Metallic Bonding. 7.3 Bonding in Metals. 7.1 Ions 7.2 Ionic Bonds and Ionic Compounds

STOCKIST SUPPLIERS & EXPORTERS:

Element, Mixture, Compound Lab

NONFERROUS METALS AND ALLOYS

Complete Solder Solutions

INSTITUTE OF INTEGRATED ELECTRICAL ENGINEERS OF THE PHILIPPINES, INC. (IIEE-ERCSA) First IIEE Accredited Foreign Chapter (Charter

Mathematics and Science in Schools in Sub-Saharan Africa

UPDATED CASE STUDY OF FIRESIDE CORROSION MANAGEMENT IN AN RDF FIRED ENERGY-FROM-WASTE BOILER

2003 International Residential Code ELECTRICAL PROVISIONS ONLY October 2005 EDITORIAL CHANGES SEVENTH PRINTING

SMP Coaxial Connectors Update

Final Examination. Instructions. Guidelines. UNIVERSITY OF CALIFORNIA College of Engineering Department of Materials Science & Engineering

Assignments. 1. Prepare Galvanic series for metals and alloys in flowing sea water. Compare this with the series available for stagnant sea water.

COMPANY LOCATION APPROVED PROCESS SPECIFICATION

INDEX METALS FERRIC METALS NON-FERRIC METALS WORKING WITH METALS METAL FORMING TECHNIQUES ENVIRONMENTAL IMPACT OF METAL EXTRACTION

Corrosion Control and Cathodic Protection Data Sheet

ZYCI CNC Machining and 3D Printing AS9100 Rev D ISO ITAR Registered

Data Bus Connector and Terminator Requirements Document DB-1001-A. Revision C

Design Aspects of Cathodic Protection

Aluminium and aluminium alloys. Castings. Chemical composition and mechanical

DESIGN GUIDELINES WIRING AND CONDUITS PAGE 1 of 7

The Leader in Oilfield Coating Technology ISO 9001:2008.

TECHNICAL SPECIFICATION Conductive Elastomer Molded Gaskets

Manufacturing and Quality Control Thermo Scientific Niton XRF Analyzers

global solutions : local support Knitted Conductive EMI Gaskets

material specifications

Science Class 8 Topic: Elements And Compounds Reinforcement Worksheet

ARCHITECTURAL ZINC. Technical Guide. Superior performance for superior design

Installation of CSST Gas Piping Systems

Marine Corrosion and its Prevention in Small Vessels

Corrosion Studies on GeoBrom HG520

An Introduction to Cathodic Protection

TECHNICAL ANALYSIS #2

Introduction to Cathodic Protection

TECHNICAL DATA SHEET 30

Fundamentals of Corrosion and Corrosion Control for Civil and Structural Engineers

Practical Checklists of Best Practices Frank Donovan, W3LPL

Electrical Insulating Tapes

Electricity and Chemistry

Material and Process. Specification

Australian Standard. Electroplated coatings of rhodium for general engineering applications AS AS 2429

SAMPLE PAGES PAGES. Extraction of metals from metal oxides. mixture of iron sand and coal are heated as they move down kiln, by force of gravity

Sapphire Metal Tile Roofing System

Cast Irons, Ductile Irons & Malleable Irons


Will accommodate up to 35 conductors while maintaining separation required to withstand instrumentation voltages

Flange Insulation Sets

Construction Specification for Cathodic Protection of New Watermains

These elements are in carbon steels in minimal amounts, usually less than 1%.

Transcription:

White Paper HELIAX FXL www.commscope.com

Contents 3 Growing Use of Dissimilar Metals in RF Transmission Lines 3 CommScope Introduces HELIAX FXL 3 Why HELIAX FXL Smoothwall Cable? 3 Galvanic Corrosion 4 Figure 1: Galvanic Corrosion Chart 4 Electrolyte Issues in the Wireless Industry 5 Blocking Moisture at the Source 6 Figure 2: HELIAX FXL s unique triple-bonded smoothwall design 6 Figure 3: HELIAX FXL cable provides a Closed Micro-Cell Dielectric 6 Figure 4: Corrugated cables foam dielectric cells are typically much larger, 6 and can absorb moisture. Field Data Confirms Claims 7 Proven Quality Backed by a 10-Year Warranty 7 CommScope Delivers Confidence 7 www.commscope.com 2

Since its introduction in 2001, one of the persistent myths surrounding HELIAX FXL cable from CommScope is that, due to its use of aluminum and copper, it is more susceptible to corrosion than other transmission line cables. However, this misconception regarding HELIAX FXL overlooks one very critical fact: without moisture there can be no corrosion1. This is where HELIAX FXL has distinguished itself from other transmission line cables. HELIAX FXL enables operators to eliminate a major cause of cable failure corrosion, while retaining all the advantages provided by the use of its dissimilar metals. HELIAX FXL uses a unique triple-bonded design that prevents moisture ingress, especially at the connector interface where corrosion is most likely to begin. The ability of HELIAX FXL to eliminate corrosion under some of the harshest environmental conditions has been well-documented with over 100 million feet deployed with major wireless operators around the globe. As a result, HELIAX FXL enables operators to eliminate a major cause of cable failure corrosion, while retaining all the advantages provided by the use of its dissimilar metals. Growing Use of Dissimilar Metals in RF Transmission Lines Historically, electrical engineers have long recognized the value in the pairing of certain dissimilar metals in the design of transmission cable. As early as 1977, copper-clad aluminum (CCA) was deployed as the preferred transmission line for the burgeoning CATV industry. More recently, wireless operators have embraced CCA as the material of choice for high frequency coaxial applications such as power cables. Why HELIAX FXL Smoothwall Cable? By incorporating aluminum into the cable design, as opposed to any other metal, HELIAX FXL provides key unique benefits: Proven: 90% of high voltage transmission lines use aluminum conductors and 99% of all CATV cables are aluminum. Lightweight and Forms to Application: Aluminum is flexible and is one-third the weight of copper. Weatherproof: Made possible by HELIAX FXL s triple-bonded construction and filled center using patented microcell foaming technology. As the demands grow for lighter, more fl exible, lower loss RF transmission cables, the potential of an all-copper design is limited. The pairing of dissimilar materials holds the key to achieving the characteristics necessary to help operators continue to increase performance while holding down costs. CommScope Introduces HELIAX FXL CommScope began leveraging its experience with dissimilar metals in the late 1990s. By 2001, engineers had successfully produced a 50-ohm transmission line cable, HELIAX FXL, using an all copper center conductor and lightweight aluminum outer conductor. HELIAX FXL offers several advantages making it attractive for operators looking to minimize CAPEX and OPEX while maintaining excellent electric performance. Compared to its corrugated all-copper competitive cable, the new HELIAX FXL smoothwall cable: Offers up to 10% better attenuation Provides 200% better crush resistance Delivers 70% better stretch resistance Weighs as much as 30% less Has reduced scrap value minimizing the risk of theft. One of the lingering myths that persist regarding HELIAX FXL is that it is more susceptible to galvanic corrosion. www.commscope.com 3

Galvanic Corrosion Galvanic corrosion occurs when dissimilar metals are connected in the presence of an electrolyte such as water. During the process of galvanic corrosion, electrons fl ow between the two metals, forming a galvanic couple. In any galvanic couple, one metal is more chemically active than the other one. The fl ow of electrons to the more active metal causes it to corrode faster than it would by itself while the less active metal will corrode slower. The key to preventing galvanic corrosion is the ability to eliminate the presence of moisture in the cable. HELIAX FXL prevents water ingress by employing a unique triple-bonded design. A metal s activity can be expressed in a table, known as a Galvanic Series. A Galvanic Series lists various metals, from most noble (least likely to corrode) to least noble (most likely to corrode). The table in Figure 1 indicates the reactivity of various metals in the presence of rainwater. The nature and aggressiveness of the environment can also impact the severity of galvanic corrosion 2. For example, acid rain, common in densely populated urban areas, provides increased conductivity that can greatly accelerate the process. 0.2 0-0.2-0.4-0.6-0.8-1.0-1.2-1.4-1.6 Magnesium Zinc Beryllium Aluminium alloys Cadmium Mild steel and cast iron Low alloy steel Austenitic cast iron Aluminium bronze Naval brass, yellow brass and red brass Tin Copper 50/50 lead tin solder Admiralty brass, aluminium brass Maganese bronze Silicon bronze Stainless steel grades 410, 416 Nickel silver 90/10 copper nickel 80/20 copper nickel Stainless steel grade 430 Lead 70/30 copper nickel Nickel alumium bronze Nickel chromium alloy 600 Nickel 200 Silver Stainless steel grades 302, 304, 321, and 347 Nickel copper alloys 400, K500 Stainless steel grades 316 and 317 Alloy 20 stainless steel Nickel iron chromium alloy 825 Titanium Gold,,platinum Graphite MOST NOBLE CATHODIC LEAST NOBLE CATHODIC Figure 1: Galvanic Corrosion Chart www.commscope.com 4

Electrolyte Issues in the Wireless Industry In wireless networks, a serious risk to network performance is cable failure due to moisture in the cable. Once inside, moisture has the potential to travel down the length of the cable through the dielectric and the inner conductor. The phenomenon known as galvanic corrosion occurs when dissimilar metals are connected in the presence of an electrolyte such as water. This process, however, assumes the presence of an electrolyte; and this is where the myth regarding HELIAX FXL s susceptibility to corrosion breaks down. By completely blocking moisture from entering the cable, HELIAX FXL eliminates any chance of corrosion. www.commscope.com 5

Blocking Moisture at the Source Using a unique triple-bonded smoothwall design (Figure 2), HELIAX FXL eliminates galvanic corrosion by not only ensuring moisture cannot enter at the connector interface but by preventing it from gaining access anywhere along the length of the cable. Jacket PE Precoat Between AL-Shield & Jacket AL-Shield Adhesive Outside of Foam Core Patented Microcell Foam Core Precoat Between Inner Conductor & Foam Core Copper Inner Conductor Adhesive Outside of Foam Core Foam Core Precoat Outside of the GRP Rod GRP Rod Figure 2: HELIAX FXL s unique triple-bonded smoothwall design The weatherproof outer jacket, engineered with black polyethylene (PE) is physically bonded to a smoothwall aluminum shielding layer. The smoothwall shielding shares a physical bond with the closed microcell foam dielectric. Closed cell foam prevents water from moving through the cable. If there is a water breach at the connector, the water is stopped and the cable can be re-cut a short distance in and be reconnected. The cable s copper center conductor is embedded in the heart of the dielectric and is completely fi lled, unlike standard coaxial cable which typically utilizes a hollow tube inner conductor. The result is a complete surface-to-surface bond that eliminates any path for water to travel along. Under magnifi cation the difference between HELIAX FXL (Figure 3), and corrugated cable (Figure 4) becomes apparent. Figure 3: HELIAX FXL cable provides a Closed Micro-Cell Dielectric which prevents water ingress-resulting in a lower life cycle cost. Figure 4: Corrugated cables foam dielectric cells are typically much larger, and can absorb moisture. www.commscope.com 6

Field Data Confirms Claims Ultimately any claims regarding the ability of HELIAX FXL to prevent corrosion are either proven or disproven in the fi eld. Thus far, fi eld results such as the following leave no question. Proven Quality Backed by a 10-Year Warranty FXL cable products are subjected to extreme testing to ensure superior quality. Once the connectors are installed properly, water migration is not an issue. All FXL cables are backed by a 10-year warranty but their expected lifespan is far longer. In 2004, CommScope presented test data and anecdotal evidence of its smoothwall cable technology to engineers of a prominent wireless OEM. Reluctant to accept the claims of a cable that had never experienced failure due to moisture, the OEM requested a series of extreme environmental tests. The trials were designed jointly by CommScope and the OEM for the singular purpose of trying to cause the cable to fail. For that reason, no secondary waterproofi ng was used and the cable assemblies were connected under the same harsh conditions to which they were subjected. The tests included Extreme Thermal Cycling and Icing, Extreme Rain, and Extreme Thermal Stress Cycling. After weeks of simulating the worst environmental conditions on earth, HELIAX FXL cable survived with unsurpassed quality and performance. (See Extreme Testing Technical Article) In total, major wireless operators around the globe have deployed over 100 million feet of HELIAX FXL cable since 2001. CommScope Delivers Confidence The pressure is increasing for operators to deliver better spectrum effi ciency while reducing both OPEX and CAPEX costs. This is true for all aspects of the backhaul network, including RF transmission cable. Operators, in turn, are looking to companies such as CommScope to develop innovative and dependable solutions. Given the design limitations inherent in an all-copper solution, the use of dissimilar metals will continue to play an important role in the success of the backhaul network. Engineers at CommScope have long recognized this. HELIAX FXL cable represents a long history that includes critical insight into RF cable design; hands-on experience with the use of dissimilar metals; and applications in the fi eld that continue to yield impressive results. 1 Handbook of Aluminum, Second Edition, Aluminum Company of Canada, pg 19 2 Corrosion of Metals and Alloys Refs. Mars G. Fontana and Denny A. Jones 3 United States Geological Survey, http://ga.water.usgs.gov/edu/watercyclecondensation.html www.commscope.com Visit our Web site or contact your local CommScope representative for more information. 2012 CommScope, Inc. All rights reserved. All trademarks identified by or are registered trademarks or trademarks, respectively, of CommScope, Inc. This document is for planning purposes only and is not intended to modify or supplement any specifications or warranties relating to CommScope products or services. WP-106154-EN (10/12) www.commscope.com 7