Evidence of Performance Airborne sound insulation of building components

Similar documents
Evidence of Performance Joint sound reduction of filling material

Evidence of Performance Joint sound reduction of filling material

Classification report Airbourne sound insulation of building elements

Evidence of Performance Joint sound reduction of filling material

Analysis Joint sound insulation of filler materials

Laboratory measurements of the reduction of transmitted impact sound by floor coverings on a heavyweight reference floor (According to ISO )

TEST REPORT. Report Number : / Report Date : 27 / 07 / 2015

ASTM E 90-09: Laboratory Measurement of Airborne Sound Transmission of Building Partitions and Elements

LABORATORY MEASUREMENTS OF THE SOUND REDUCTION INDEX ROCKWOOL ABLATIVE COATED BATTS

Evidence of Performance Calculation of thermal transmittance

Evidence of Performance Thermal transmittance

Sound Insulation for Glass and Panel

Important Notice. QuietRock by PABCO Gypsum Cherry Street Newark, CA

Important Notice. QuietRock by PABCO Gypsum Cherry Street Newark, CA

KINETICS NOISE CONTROL TEST REPORT #AT001067

Signatures are required on this document for an official laboratory test report. Copies of this document without signatures are for reference only.

148th MEETING OF THE ACOUSTICAL SOCIETY OF AMERICA November 15-19, 2004 (San Diego, California, USA)

KINETICS NOISE CONTROL TEST REPORT #AT001035

KINETICS NOISE CONTROL TEST REPORT #AT001110

THE FRAME RESIDENTIAL DEVELOPMENT, SPORTCITY, MANCHESTER THE CONCRETE CENTRE LTD 1.0 INTRODUCTION...2

KINETICS NOISE CONTROL TEST REPORT # AT001084

ASTM E 90 SOUND TRANSMISSION LOSS TEST REPORT. Rendered to: THERMA-TRU DOORS. SERIES/MODEL: Slimline. TYPE: 8/0 Sliding Patio Door

TEST REPORT NO

Developing a component catalogue for determining airborne sound insulation as well as flanking sound insulation of curtain walling

E R0 ACOUSTICAL PERFORMANCE TEST REPORT ASTM E90. Rendered to: THERMA-TRU CORPORATION

slimlite Double Glazed Units BS EN 1279 Certificate Double Glazed Units

CASE STUDY OF THE SOUND REDUCTION OF VARIOUS RESIDENTIAL GLAZING TREATMENTS

Proceedings of Meetings on Acoustics

European Round Robin Test for sound insulation Measurements of lightweight partition.

White Paper. A guide to the acoustic performance of Smarts Systems Products. Building Regulations Document E Resistance to the passage of sound

E R0 ACOUSTICAL PERFORMANCE TEST REPORT ASTM E90. Rendered to: PAC INTERNATIONAL, LLC

E R0 ACOUSTICAL PERFORMANCE TEST REPORT ASTM E 90 AND ASTM E 492. Rendered to SENECA RADIANT TECHNOLOGIES

-Letter - Tables 1 and 2 - Figure 1 - Exhibits 1 through 6

This page was. intentionally. left blank

Evidence of Performance regarding the requirements for float glass according to EN 572

Acoustics in wooden buildings Measurements in the Laboratory and in Single Family Houses

INTERCOMPARISON OF LABORATORY MEASUREMENTS OF AIRBORNE SOUND INSULATION OF PARTITIONS. A. Farina (1), P. Fausti (2), R. Pompoli (2), F.

Report. Laboratory for Acoustics Determination of the insertion loss or sound power insulation of Arma-Chek Sound Insulation

movable walls Space Optimal Solutions

KINETICS NOISE CONTROL TEST REPORT #AT001108

H R0 ACOUSTICAL PERFORMANCE TEST REPORT ASTM E 90 AND ASTM E 492. Rendered to AMORIM CORK COMPOSITES

Acoustic Testing of CLT and Glulam Floor Assemblies Nordic Engineered Wood Report No. A August 2016 CONSTRUCTION

Day Night Day Night Day Night Residential site and amphitheatre Green Non residential site boundary Red

Available online at ScienceDirect. Energy Procedia 78 (2015 ) th International Building Physics Conference, IBPC 2015

Measurement of the insertion loss of the pipe clamp FRSPlus for 4 sewer pipes

Sound Insulation Test Easterton of Duntelchaig, Farr, Inverness, IV2 6AW

C R0 ACOUSTICAL PERFORMANCE TEST REPORT ASTM E 90 AND ASTM E 492. Rendered to. ECORE International. Series/Model: Base 10

E R0 ACOUSTICAL PERFORMANCE TEST REPORT ASTM E 492 AND ASTM E Rendered to REGUPOL AMERICA

CJ Buma. To: Steelform Building Products Inc. Wednesday, 2007 May Avenue Edmonton, AB, T6B 2V2. Attn: Mr.

OPTIWIN MOTURA. Technical Description. Synopsis:

The effect of additional thermal lining on the acoustic performance of a wall

Report for the U-value of a Door System in Accordance with BS EN ISO :2006. Product description:

Acoustic Design Criteria

DETAILED ANALYSIS OF MEASUREMENT RESULTS OF FLANKING TRANSMISSION ACROSS A JUNCTION COM- POSED OF DOUBLE WALLS CARRIED OUT ON A HALF SCALED TEST BENCH

SOUND INSULATION TESTING IN DWELLINGS

RIVERBANK ACOUSTICAL LABORATORIES

Österreichisches Institut für Bautechnik Schenkenstrasse Vienna Austria T F

The Optimization of a Wooden Floor Design Based on Validated Finite Element Models

Report. Draft. Laboratory for Acoustics

NYU Core: Post-EIS Façade Improvement Acoustical Assessment

P.O. Box ZN Bleiswijk Brandpuntlaan Zuid NZ Bleiswijk The Netherlands

Acoustic Detailing For Steel Construction

Technical data sheet StoSilent Board 310

ACOUSTICAL TREATMENT OF EMERGENCY POWER GENERATOR. Dr. M.Abd El Gawad Saif

Testing Procedure: AS ISO

Technical Features Sound Construction Design Aid For Office Acoustics

CONDUCTED: 26 November 2013 Page 1 of 6

RMF Intercell. NBS Specification 2013 K41

Radiation Shielding Glass RD 30 RD 50

inter.noise 2000 The 29th International Congress and Exhibition on Noise Control Engineering August 2000, Nice, FRANCE

FLOOR CEILING ASSEMBLY

Ecophon Akusto Wall C

RR-337 Apparent Sound Insulation in Cold-Formed Steel-Framed Buildings. Christoph Hoeller, David Quirt, Berndt Zeitler, Ivan Sabourin.

PIP INSA1000 Acoustic Insulation Systems Specification

Sound Insulation with Hilti Firestop products

TPS Thermo Plastic Spacer

The ATP that follows is recommended to be used for all phases of the FLL RSIP beginning June 1, The ATP describes the following:

RIVERBANK ACOUSTICAL LABORATORIES

June Residential Refurbishment Separating walls

WEEDOO - SA CONSTRUCTION TECHNOLOGY

RIVERBANK ACOUSTICAL LABORATORIES

TP LITE. Office Partitions. Technical guide

Observation of Liquid-filled Window without Presence of Liquid in Test Chamber

J. A. FERREIRA, F. B. DINIZ, A. FERREIRA and P. H. T. ZANNIN

IAC Acoustics Noise-Foil Sound Absorption Panels for Industrial Applications. Dan O Brien

Concepts. Products. Service. Partitions Lindner Logic

Prediction of the acoustic performance of floor coverings on lightweight floors

Technical data sheet StoSilent Board 110

NOISE BARRIER AT WELDING WORKPLACE

Influence of design and leakages of the window-wall connection on the sound insulation.

CONDUCTED: 26 November 2013 Page 1 of 6

Shape, structure and space experience. Light and simplistic design. Baya partitions are available in single and double glazed versions.

RIVERBANK ACOUSTICAL LABORATORIES

Wooden roof: evaluation of acoustic performances performed in laboratory, on an external test-cell, and on real buildings

ITB TECHNICAL APPROVAL AT /2012. XPS extruded polystyrene Panel-Base Products

ACOUSTIC DESIGN OF THE AUDITORIUM IN THE CHURCH OF RISPESCIA

Technical Assessment Body issuing the ETA: Kiwa Nederland B.V. Sinh Board

SINTEF Building and Infrastructure confirms that. Separating floors with Hunton Silencio 36 / Hunton Silencio Thermo

Transcription:

Evidence of Performance Airborne sound insulation of building components Test Report No. 14-000251-PR01 (PB Z09-H01-04-en-02) Client Product Designation PRESS GLASS SA Nowa Wies Kopalniana 9 42-262 Poczesna Poland Insulating glass unit Type 33.1 TH1,1 kl.2(b)2+12+fl 4+12+33.1 TH1,1 kl.2(b)2 Ar Basis EN ISO 10140-1 : 2010 +A1:2012 EN ISO 10140-2 : 2010 EN ISO 717-1 : 2013 14-000251-PR01 (PB Z09-H01-04-en-01) dated 23rd of May 2014 Representation External Dimensions (W x H) Construction Gas filling Area related mass Special features -/- 1,230 mm 1,480 mm 6LSG / 12 / 4 / 12 / 6LSG Argon 40.4 kg/m² Weighted sound reduction index R w Spectrum adaptation terms C and C tr 6LSG 12 4 12 6LSG Instructions for use This test report serves to demonstrate the airborne sound insulation of a building component. Applicable for Germany. R w corresponds to R w,p for DIN 4109, Annex 1, Table 40 ift Rosenheim 05.06.2014 R w (C; C tr ) = 37 (-3;-8) db Validity The data and results given relate solely to the tested and described specimen. Testing the sound insulation does not allow any statement to be made on further characteristics of the present construction regarding performance and quality. Dr. Joachim Hessinger, Dipl.-Phys. Head of Testing Department Building Physics Andreas Preuss, Dipl.-Ing. (FH) Head of Laboratory Building Acoustics Notes on publication The ift-guidance Sheet "Conditions and Guidance for the Use of ift Test Documents" applies. The cover sheet can be used as abstract. Ve-Prü-1303-de / 01.02.2014 Contents The test report contains a total of 7 pages: 1 Object 2 Procedure 3 Detailed results 4 Instructions for use Data sheet (1 page)

Evidence of Performance Page 2 of 7 1 Object 1.1 Description of test specimen (All dimensions in mm) Component Insulating glass unit Product designation Type 33.1 TH1,1 kl.2(b)2+12+fl 4+12+33.1 TH1,1 kl.2(b)2 Ar External dimensions (W x H) 1,230 mm 1,480 mm Visible size (W x H) 1,200 mm 1,450 mm Total thickness On the edge 40.9 mm In the middle of pane 41.4 mm Area related mass kg/m² 40.4 kg/m² Construction 6LSG / 12 / 4 / 12 / 6LSG Construction of laminated glass / 33.1 / 0.38mm, 33.1 / 0.38mm layer dimension Type / of the laminated PVB / Guardian glass Pane temperature in C 21 C Spacers Material Aluminium - Vetrim Alu-Pro Edge seals Two planes, total width 9-10 mm External type PS (Thiover) Fenzi Internal type PIB (Butylver) Fenzi Edge cover Edge cover 5-6 mm Gas filling in cavity According to analysis at ift Type of gas Argon Volume in % 98% / 99% The description is based on inspection of the test specimen at ift Laboratory for Building Acoustics. Item designations / numbers as well as material specifications were provided by the client. 1.2 Mounting in test rig Test rig Mounting of test specimen Window test rig Z with suppressed flanking transmission acc. to EN ISO 10140-5: 2010; the test rig includes a mounting frame with a continuous acoustic break which is sealed in the test opening with closed-cell permanently resilient sealant. Test specimen mounted by ift Laboratory for Building Acoustics.

Evidence of Performance Page 3 of 7 Mounting conditions Mounting position Preparation The unit was fitted at a distance of 5 mm into a wooden frame of 25 mm x 25 mm cross section. The cavity between test rig and glazing beads was completely filled with plastic sealant type Perennator 2001 S grey. according to EN ISO 10140-1:2010+A1:2012 Annex D Storage of the glazing one day before testing in the test rig for conditioning. 2 Procedure 2.1 Sampling Sampling The test specimen were selected by the client Quantity 1 PRESS GLASS SA Manufacturing plant, Site of PRESS GLASS SA Division in Radomsko manufacturing Date of manufacture / 9th of April 2014 date of sampling Production line 1 Responsible for sampling Mr. Machura, Pawel Delivery at ift 10th of April 2014 by the client via forwarding agency ift Registration Number 36884/09 2.2 Process Basis EN ISO 10140-1:2010 + A1 : 2012 Acoustics; Laboratory measurement of sound insulation of building elements - Part 1: Application rules for specific products (ISO 10140-1:2010+Amd.1:2012) EN ISO 10140-2:2010 Acoustics; Laboratory measurement of sound insulation of building elements - Part 2: Measurement of airborne sound insulation (ISO 10140-2:2010) EN ISO 717-1: 2013 Acoustics; Rating of sound insulation in buildings and of building elements - Part 1: Airborne sound insulation Corresponds to the national German standard: DIN EN ISO 10140-1:2012-05, DIN EN ISO 10140-2:2010-12 and DIN EN ISO 717-1 : 2013-06

Evidence of Performance Page 4 of 7 Procedure and scope of measurement are in conformity with the principles of the Working Group of sound insulation testing bodies approved by the national building supervisory authorities in cooperation with the standardization committee NA 005-55-75-AA (subcommittee UA 1 - DIN 4109). Boundary conditions Deviation Test noise Measuring filter Measurement limits Low frequencies As required in the standard. There are no deviations from the test procedure and/or test conditions. Pink noise One-third-octave band filter The dimensions of the receiving room were smaller than recommended for testing in the frequency range from 50 Hz to 80 Hz as per EN ISO 10140-4:2010 Annex A (informative). A moving loudspeaker was used. Background noise level The background noise level in the receiving room was determined during measurement and the receiving room level L 2 corrected by calculation as per EN ISO 10140-4: 2010 Clause 4.3. Maximum sound insulation The maximum sound insulation of the test set-up was at least 15 db higher than the measured sound reduction index of the test specimen. Not corrected by calculation. Measurement of reverberation time Measurement equation A Measurement of sound level difference arithmetical mean: two measurements each of 2 loudspeaker and 3 microphone positions (a total of 12 independent measurements). V A = 0,16 m² T Minimum of 2 loudspeaker positions and rotating microphones. Measurement equation R S = L1 L + 10 lg in db A R 2 KEY A Equivalent absorption area in m² L 1 Sound pressure level source room in db L 2 Sound pressure level receiving room in db R Sound reduction index in db T Reverberation time in s V Volume of receiving room in m³ S Testing area of the specimen in m²

Evidence of Performance Page 5 of 7 2.3 Test equipment Device Type Integrating sound meter Type Nortronic 840 Norsonic-Tippkemper Microphone preamplifiers Type 1201 Norsonic-Tippkemper Microphone unit Type 1220 Norsonic-Tippkemper Calibrator Type 1251 Norsonic-Tippkemper Dodecahedron loudspeakers Own Design - Amplifier Type E120 FG Elektronik Rotating microphone boom Own Design / Type 231-N-360 Norsonic-Tippkemper The ift Laboratory for Building Acoustics participates in comparative measurements at the Physikalisch-Technische Bundesanstalt (PTB) in Braunschweig every three years, the last one was in April 2013. The sound level meter used, Series No. 17848, was calibrated by the Dortmund Eichamt (calibration agency) on 19 January 2012. The calibration is valid until 31 December 2014. The sound level meter used was DKD calibrated by the company Norsonic Tippkemper (DKD - Deutscher Kalibrierdienst German Calibration Service ) on 25 March 2013. 2.4 Testing Date 23rd of April 2014 Operating Testing Officer Andreas Preuss 3 Detailed results The values of the measured sound reduction index of the tested Insulating glass unit are plotted as a function of frequency in the annexed data sheet and tabled. As per EN ISO 717-1 the weighted sound reduction index R w and the spectrum adaptation terms C and C tr for the frequency range 100 Hz to 3150 Hz obtained by calculation are as follows: R w (C;C tr ) = 37 (-3;-8) db According to EN ISO 717-1 the following additional spectrum adaptation terms are obtained C 50-3,150 = -3 db C 100-5,000 = -2 db C 50-5,000 = -2 db C tr,50-3,150 = -8 db C tr,100-5,000 = -8 db C tr,50-5,000 = -8 db

Evidence of Performance Page 6 of 7 4 Instructions for use 4.1 Test value Basis DIN 4109:1989-11 Sound insulation in buildings, requirements and verifications DIN 4109 Bbl1/A1:2003-09 Sound insulation in buildings, examples and calculation methods correction A1 For verification of sound insulation according to DIN 4109, Annex 1 : A1:2003-09, Table 40 the weighted sound reduction index R w corresponds to the test value R w,p, GLASS R w,p, GLASS = 37 db 4.2 Laminated glass The sound reduction of laminated glass depends on the temperature of the environment. If the temperature is lower than the test temperature the sound reduction index may be reduced. 4.3 Test standards The standard series EN ISO 10140:2010 supersedes those parts of the standard series EN ISO 140 that were applicable until the respective date and describe laboratory tests. According to the two standard series, the test methods are identical. ift Rosenheim Laboratory for Building Acoustics 05.06.2014

Sound reduction index according to ISO 10140-2 Laboratory measurements of airborne sound insulation of building elements Client: PRESS GLASS SA Nowa Wies, 42-262 Poczesna (Poland) Product designation Type 33.1 TH1,1 kl.2(b)2+12+fl 4+12+33.1 TH1,1 kl.2(b)2 Ar Design of test specimen Insulating glass unit External dimensions 1,230 mm 1,480 mm Pane configuration 6LSG / 12 / 4 / 12 / 6LSG Gas filling in cavity Argon Area related mass 40.4 kg/m² Pane temperature 21 C f in Hz R in db 50 27.4 63 30.3 80 28.6 100 20.1 125 12.0 160 20.5 200 21.9 250 27.0 315 28.6 400 31.7 500 35.0 630 39.6 800 43.3 1,000 46.8 1,250 47.4 1,600 47.5 2,000 42.6 2,500 42.5 3,150 50.8 4,000 59.4 5,000 67.5 Sound reduction index R in db 60 50 40 30 20 Test date 23rd of April 2014 Test surface S 1.25 m 1.50 m = 1.88 m 2 Test rig as per EN ISO 10140-5 Partition wall Double-leaf concrete wall, insert frame Test noise pink noise Volumes of test rooms V S = 104 m³ V R = 67.5 m³ Maximum sound reduction index R w,max = 62 db (related to test surface) Mounting conditions Glass mounted in test opening and held on both sides by glazing beads (25 mm 25 mm); gap between test rig, glazing and glazing beads was completely filled with plastic sealant Climate in test rooms 21 C / 50 % RH Static air pressure 962 hpa Shifted reference curve Measurement curve Frequency range corresp. to reference curve as per EN ISO 717-1 Frequency f in Hz Rating according to EN ISO 717-1 (in third octave bands): R w (C;C tr ) = 37 (-3;-8) db C 50-3,150 = -3 db; C 100-5,000 = -2 db; C 50-5,000 = -2 db C tr,50-3,150 = -8 db; C tr,100-5,000 = -8 db; C tr,50-5,000 = -8 db Test report No.: 14-000251-PR01 (PB Z09-H01-04-en-02) Page 7 of 7, Data Sheet No. Z9 ift Rosenheim Laboratory for Building Acoustics 5. June 2014 10 63 125 250 500 1000 2000 Dipl. Ing. (FH) Andreas Preuss Operating testing officer 4000