Millenium 29 de setembro de 2017 SP / SP. do Laboratório de Pesquisa ao Canteiro de Obras

Similar documents
Fundamentals of Concrete

A-4 TEST DATA FOR MATERIALS v) Cement used : OPC 43 grade confirming to IS 8112 w) Specific gravity of cement : 3.15 x) Specific gravity of

PUNCHING RESEARCH AT UNIVERSIDADE NOVA DE LISBOA

Chapter VI Mix Design of Concrete

Finite Element Analysis for Structural Reinforcements in Concrete Railway Bridges

MICHIGAN CONCRETE ASSOCIATION GUIDE FOR COLD WEATHER CONCRETING

Effect of Micro Silica on the properties of hardened concrete

A STUDY ON THE ENHANCEMENT OF DURABILITY PERFORMANCE OF FACED SLAB CONCRETE IN CFRD

Index Terms- Copper Slag (CS), Silica Fume (SF), Physical Properties, Compressive Strength, Flexural Strength.

MANUFACTURER S SPECIFICATIONS Section LIME CONCRETE. A. This section describes the requirements for floors and slabs on grade.

Council on Tall Buildings. and Urban Habitat CAYAN TOWER CTBUH BEST TALL BUILDING MIDDLE EAST & AFRICA

SUPPORTING A SUSTAINABLE FUTURE WITH MICROSILICA CONCRETE

Durability Predictions Using Early-Age Durability Index Testing

Comparison of Properties of Fresh and Hardened Concrete Containing Finely Ground Glass Powder, Fly Ash, or Silica Fume

ICRI 2017 Spring Convention March 15-17, 2017

September 14, Structural Engineers Assn. of Ohio Cold & Hot Weather & Freezing. Ken Hover, P.E., Cornell University

Anil Kumar Nanda, Jaspal Singh. Evaluation of Relation between Split Tensile and Compressive Strength of OPC Concrete

SECTION CONCRETE. B. ACI 318 Building Code Requirements for Structural Concrete and Commentary

Mix Design Statistical Analysis Program Guidelines

Influence of Restraint Conditions and Reinforcing Bar on Plastic Shrinkage of Self-consolidating Concrete

10/10/2007. Is it Dark at Night?

A STUDY ON LONG-TERM PERFORMANCE OF CONCRETE OVER 50 MPa IN COMPRESSIVE STRENGTH

Statistical Modeling and Prediction of Compressive Strength of High Performance Concrete

USE OF DURABILITY-RELATED TESTS FOR QUALITY CONTROL: VARIABILITY OBTAINED IN A REAL CASE

HIGH PERFORMANCE CONCRETE - HPC

Studying of Floating Concrete Report Fall

Strength Characteristics of Concrete Mix by Replacing Fine Aggregates with Industrial Sand

International Journal of Engineering Science Invention Research & Development; Vol. I Issue X April e-issn:

REQUIREMENTS FOR CONCRETE MIX DESIGN

STUDY ON SILICA FUME REPLACED CONCRETE WITH SUPER PLASTICIZER

DIVISION 3 HEAVY DUTY CONCRETE FLOOR TOPPING SECTION 03340

Total 30. Chapter 7 HARDENED CONCRETE

STRENGTH AND DURABILITY PROPERTIES OF HIGH PERFORMANCE CONCRETE INCORPORATING SILICA FUME

STUDY OF THE VARIABLES IN LABORATORY TESTING OF CEMENT STABILIZED MATERIALS

Ash Recycling in Pasco County

PROPORTIONING CONCRETE MIXES

Experimental Case Study Demonstrating Advantages of Performance Specifications

Effect of Different Types of Coarse Aggregates on Physical Properties of Mostly Used Grades M20, M25, M30 of Concrete

Course Concrete Technology Course Code Theory Term Work POE Total Max. Marks Contact Hours/ week

CSU GUIDELINES. April 27, 2018 FOR POST-TENSIONED CONCRETE STRUCTURES.

INSPECTION MANUAL FOR SELF-CONSOLIDATING CONCRETE IN PRECAST MEMBERS

Mix Design For Concrete Roads As Per IRC:

Laboratory Assessment of Drying Shrinkage of Concretes Containing Shrinkage Reducing Agents Compared with a New Low shrinkage Concrete

MECHANICAL PROPERTIES OF HIGH-PERFORMANCE CLASS C FLY ASH CONCRETE SYSTEMS

ECS. High Strength Concrete. North Harbour Stadium Influences on Concrete Strength Performance. ECS High Strength Concretes

This paper presents the results of a case study

Experimental research for the determination of some parameters needed for the calculation of life-cycle CO 2 emission of reinforced concrete buildings

NRMCA is working on. Experimental Case Study Demonstrates Advantages of Performance Specifications

FINLAND ADVANCES IN CONCRETE AND CEMENTITIOUS COMPOSITES AND APPLICATIONS TO CIVIL INFRASTRUCTURE

THE EFFECT OF ADDITION OF LIMESTONE POWDER ON THE PROPERTIES OF SELF-COMPACTING CONCRETE

Mass concrete placements often require significant

12 th Canadian Masonry Symposium Vancouver, British Columbia, June 2-5, 2013

Shear strength of slender SCC beams possible differences from VC beams

SECTION CAST-IN-PLACE CONCRETE FOR UTILITIES

NON DESTRUCTIVE TESTING OF THE CONCRETE COVER EVALUATION OF PERMEABILITY TEST DATA

FIBER ADDITION AND ITS EFFECT ON CONCRETE STRENGTH

Properties of Concrete Incorporating Recycled Post-Consumer Environmental Wastes

MATERIAL SPECIFICATION FOR CONCRETE - MATERIALS AND PRODUCTION

Minimum cement content requirements: a must or a myth?

Section A A: Slab & Beam Elevation

Tolerances- Section

Effect of Steam Curing on the Strength of Concrete by Using Mineral Admixtures

EVOLUTION OF HIGH STRENGTH CONCRETE OF M80 GRADE

A Study on Mechanical Properties of Sisal Fiber Reinforced Concrete

The Effect of Cement Type on Behavior of Reinforced Concrete against Attack Sulfate Salt

ctbuh.org/papers Optimal Combination between Concrete Strength and Sets of Forms in High-rise Building Title:

Effect Of Curing Age On The Compressive Strength Of Concrete Made From Local Granite Chippings

Determination of compressive strength difference between conventional concrete and recycled aggregate concrete

Properties of Fly Ash Based Coconut Fiber Composite

Keywords: Drying Shrinkage of Concrete, Autogenous Shrinkage, Design Shrinkage Strain

CONCRETE MIX DESIGN. Dr. B.N. KRISHNASWAMI TECHNICAL MEETING ON ORGANISED BY CIVIL ENGINEERS & ARCHITECTS ASSOCIATION, KUMBAKONAM

DURABILITY of CONCRETE STRUCTURES. Part- 3 Concrete Cracks

RESILIENT INFRASTRUCTURE June 1 4, 2016

LAFARGE. Tercem 3000 Blended Hydraulic Cement. Provides flexibility in concrete proportioning to assist in achieving: Higher Ultimate Strength

MATHEMATICAL MODELING FOR DURABILITY CHARACTERISTICS OF FLY ASH CONCRETE

Behavior of Steel Fiber Reinforced Concrete for M-25 Grade

Properties of Concrete. Properties of Concrete. Properties of Concrete. Properties of Concrete. Properties of Concrete. Properties of Concrete

Shrinkage Development in High Performance Concrete. Ammar Yahia, P.Eng., Ph.D.,

POZZOLANIC CEMENT Fly ash based (CEM IV/B-V 32,5N) Properties & Applications

SECTION 347 PORTLAND CEMENT CONCRETE CLASS 1 (NON-STRUCTURAL)

Microsilica in Concrete

International Journal of Scientific & Engineering Research, Volume 7, Issue 9, September ISSN

Cyclic behaviour of RC beams using SIFCON Sections

Concrete Cooling Towers - Salt Water

Effect of supplementary cementitious materials on the properties of pervious concrete with fixed porosity

Trusted ICC ES MILAN ITALY SYSTEMS. Look. Conformity! Evaluation. ICC-ES Evaluation

Art Museum in São Paulo, Brazil. Alan Strong Carrie Greene James Haliburton Leticia Keremian James Adams

Experimental Investigation on High Performance Concrete Using Silicafume And Flyash

Optimizing Concrete Mixtures for Performance and Sustainability

Effect of nano-silica on properties of blended cement

Bond between self-compacting concrete and reinforcement

Recommended Specifications For Portland Cement Pervious Pavement

CARBONATION OF MEDIUM STRENGTH SCC

OBJECTIVES OF PRESENT WORK

Coloured Mineral Dry Shake Floor Hardener

NATURAL POLYMER AS WATERPROOFING COMPOUND IN CEMENT CONCRETE

EFFECT OF SILICA FUME ON STRENGTH AND DURABILITY PARAMETERS OF CONCRETE

A Study on the Influence of Mineral Admixtures in Cementitious System Containing Chemical Admixtures

SELF-CONSOLIDATING CONCRETE FOR SLIP-FORM CONSTRUCTION: PROPERTIES AND TEST METHODS

Durability, Concrete, Environment and Sustainability in the Eurocodes

Transcription:

Millenium 29 de setembro de 2017 SP / SP do Laboratório de Pesquisa ao Canteiro de Obras Paulo Helene PhD Engenharia President Full Professor Universidade de São Paulo IBRACON Director & Permanent Conselour ALCONPAT Internacional Honor President Deputy Chairman fib Model Code for Service Life Design CNTU & SEESP Conselour

Concrete Structures Sustainability 1. Cement performance concept: f ck = 20MPa cement content > 12 kg/mpa f ck = 50 MPa cement content > 8 kg/mpa f ck = 90 MPa cement content > 5 kg/mpa Material Bauru/SP (C20) Petronas Tower (C50) Burj Kalifa (C80) cement 269 400 400 silica - 44 50 fine 912 775 830 coarse 891 1000 847 water 196 180 160 W/C 0.73 0.45 0.32 others 1.5% (admixture) 2.0% (admixture) 3.5% (admixture)

Concrete Structures Sustainability 2. Control age concept: f ck at 63 days cement content can reduce: for f ck = 20MPa 16 kg less cement/m 3 for f ck = 50 MPa 26 kg less cement/m 3 for f ck = 90 MPa 30 kg less cement/m 3 The Burj Dubai project E c = 44 GPa at 91 days Concrete cube strengths at 56 days: Mat slab: SCC 6000 psi SCC 35 MPa Core walls and columns: 11,600 psi 65 MPa

Concrete Structures Durability Durability Limit State (DLS) concept: Carbonation ( deterministic approach): No risk and no DSL for water satured concrete No risk and no DLS for Dry Environmental RH < 70% and superficial concrete humidity < 5%

Concrete Structures Durability Durability Limit State (DLS) concept: Carbonation ( deterministic approach): For wet environmental (and dry and wet) 70% < RH < 95% and superficial concrete humidity > 5% Model for Service Life Design preview: c CO2 = k CO2 * t DLS: carbonation deep (c CO2 ) = concrete cover (c) t service life target in years k CO2 carbonation coefficient in mm/ year Valid for all agressiveness environmental class

Concrete Structures Durability Durability Limit State (DLS) concept: Reference carbonation coefficients: f ck k CO2 in mm/ 20 3.55 25 3.15 30 2.85 35 2.45 40 2.10 45 1.35 50 to 90 0.45 year Notes: 1. For concretes with slag, fly-ash, microsilica and metacaulim, increase 20% in k CO2 values; 2. Deterministic approach means at the end of service life, 50% exposed reinforcement could be no passivated

Concrete Strength Control Comparing ABNT NBR 6118 / NBR 12655 ACI 318 EN (fib) 206

Summary - frequency of control ABNT NBR 12655 every 8m³!! ACI 318-14 once a day concreted; once per 115 m³ of concrete; once per 465 m² of slabs or walls; dispensed the control for volumes <38m³ 3 samples in the first 50m³; EN 206-1:2013 Initial production (until at least 35 test results are obtained) 1 per 200 m³ or 1 per 3 production days (concrete with production control certification) 1 per 150 m³ or 1 per production day (concrete without production control certification) Continuous production (when at least 35 test results are available) 1 per 400 m³ or 1 per 5 production days or 1 per calendar month (concrete with production control certification) 1 per 150 m³ or 1 per production day (concrete without production control certification)

Summary - conformity criteria ABNT NBR 12655 f ck,est f ck ACI 318-14 f ci f ck 3.5MPa para f ck < 35MPa f ci 0.9*f ck para f ck > 35MPa f cm3,est f ck EN 206-1:2013 f ci f ck 4; f cm,3,est f ck + 4 f cm,15,est f ck + 1.48 *s

Millenium 29 de setembro de 2017 SP / SP do Laboratório de Pesquisa ao Canteiro de Obras Paulo Helene PhD Engenharia President Full Professor Universidade de São Paulo IBRACON Director & Permanent Conselour ALCONPAT Internacional Honor President Deputy Chairman fib Model Code for Service Life Design CNTU & SEESP Conselour

Concrete Strength in Existing Structures 1. Correct the compressive strength of the concrete cores using only the form coefficients (0.82 to 1.00), the extraction / placement direction (1.05), the core damage (1.06) and the humidity [saturated ( 1.00); environment (0.95); dry (0.90)]. Result: f ck,eq = 0.86 a 1.11*f c,core 2. Disregard the effects of growth (hydration), the decrease by sustained load, the decrease by insufficient consolidation and the decrease due to inadequate cure, considering included;

Concrete Strength in Existing Structures 3. Adopt as f ck,eq the value obtained at the test date. (fib Bulletin 80 and ACI 318) Bulletin fib 80 Pág. 37 4.1.6 Estimation of characteristic values and treatment of statistical uncertainties EN 1990:2002 provides guidance on estimating characteristic values of material properties based on small samples. If the characteristic strength values for existing structures are determined based on test samples, time-dependent and environmental effects can be considered as inherently included. However shape effect and the damage effect introduced by the extraction of test material are still to be included through a conversion factor

ACI 318-14 Building Code Requirements for Structural Concrete and Commentary. 2015. 520p. Chapter 26. Construction Documents and Inspection.

Concrete Strength in Existing Structures 3. 4. On the security check, whenever the geometry, dimensions, plumb line, level, orthogonal and the position and reinforcement ratio are correct, use g c = 1.31 and g s = 1.05

According to fib MC2010 the partial factor g M is obtained as the following product: g M = g Rd * g m = g Rd1 * g Rd2 * g m where g Rd1 denotes the partial factor accounting for model uncertainties, g Rd2 is the partial factor accounting for geometrical uncertainties and g m is the partial factor accounting for variability of the material and statistical uncertainties. The partial factors related to the model and geometrical uncertainties for concrete: g Rd = 1.05 * 1.05 = 1.10 for new structures g Rd = 1.05 * 1.00 = 1.05 for existing structures g C = g Rd * g m = g Rd1 * g Rd2 * g c = 1.5 for new structures g C = g Rd * g m = g Rd1 *1.00 * 0.9 * g c = 1.31 for existing (well build) structures

Building in SP Built between 1957 and 1960 ABNT NB1:1950 f ck = 13 MPa 1959

2014

Floor type nº Columns (type): 46 nº of beams (type): 68

Schematic cross 1 Underground 1 Ground floor 10 Floor type 1 Cover slab 1 Machine House 1 Helipad

Results of cores samples after 50 years Cores made on 80 columns of a total of 460 columns of the Tower (~ 17% of the total) Cores in 6 beams / slabs (Ground & Underground)

Results of cores samples after 50 years Corrections adopted: test f ck,eq = 1.06 * 1.05 * f c,ext Reduction of g C from 1.50 to 1.31

Cores NORMAL DISTRIBUTION

Cores NORMAL DISTRIBUTION

Assessment before Retrofit Same structural model of concrete structure used in 1958; Evaluation by NB-1 1978 with some criteria from ABNT NBR 6118:2003, including fire design; Results indicate the need to strengthening 2 columns and 4 beams, besides to increase 2 cm in the thickness of all slabs and beams to protect against fire.