RISK ASSESSMENT OF SYSTEMS IN RESIDENTIAL LOG BOOK

Similar documents
A Short Presentation on Legionnaires' Disease. By Tom Toumazou Private Rented Sector Consultant

Legionella Procedure. Document Control. Date of next Review. Revision No. Publication on Web Site. Date Document Reviewed. Summary of main changes

CIBSE & SoPHE CPD Technical Evening

Local Authorities risk assessment of plumbing in private premises

first flush water diverters water quality first downspout, post/wall mounted and in-ground diverters

Investigation of the MHI Q-Ton Heat Pump

Edinburgh Napier University

Mains Water System Regulations

Water Use In Your Business

Water and Sewer connections application form. Section 1. 1a. Applicant details

System & Equipment Checkout Procedure Client Name Plant Location

Water Service Inspection Checklist

Activated carbon and cross-flow UF filter. Water Plant. Water Cleaned for You and after You

Newport City Council Bettws High School Underfloor Heating Specification CONTRACT 2

A Technical Perspective on Controlling Legionella in Building Water Systems

Water reuse systems. Guidance and advice.

BWT WATER FILTRATION Protecting what matters through innovative water filtration

London School of Economics & Political Science. Policy for the Control of Legionella Bacteria in Water Systems

23 Supply Drinking Water Without Power

Indoor Building Survey and Product Inventory

Training Certification Categories

STOP. If you think there may be an issue with your rainwater harvesting system, follow our handy check list and suggestions on how to put it right.

CONTROL OF LEGIONELLA FOR THE CAR WASH INDUSTRY

3. Sanitary Plumbing Single Stack System

RAINWATER HARVESTING SYSTEMS

WARWICK TOWNSHIP Dept. of Planning & Zoning

University of Edinburgh. Engineering Services. Guidelines

Inspection Report. 1 of 8

Annex O To Loughborough University Estates Services Health and Safety Policy

Bateau, Crucible and Timpani Vessels Installation and User Guide

RAINWATER HARVESTING SYSTEMS FOR DOMESTIC APPLICATIONS

Rainwater Harvesting Systems for Domestic Applications

Rain Captor. Residential & Commercial Rainwater Collection Systems.

your guide to completing an application for a new or replacement water connection from your property to an existing water main

This policy will generally explain the following in regards to the City sewerage collection systems:

Septic System Management Plan for Below Grade Systems

Date Rater Verified. Rater Verified. Slab / Pre-Drywall / Thermal Inspection

RD01 WHAT S IN THE BOX INSTALLATION MANUAL

Submittal for Aquatherm Piping System

ACO Building Drainage

Your Guide To Customised Solar & Water Based Heating

New Water Connection Application (up to 32mm) Article 79 - Water and Sewerage Services (Northern Ireland) Order 2006

User Guide. Enviro-Septic System. Residential Application. DBO Expert inc.

Truth in Sale of Housing Disclosure Report NOTICE - Read Entire Report Carefully. This is not a Buyer's Inspection!

Stormwater Management Practice Note NSC 07: Detention Tanks

THE ANTI-LEGIONELLAE CIRCUIT: A SIMPLE WAY OF HEAT TREATING PIPES TO KEEP LEGIONELLA AT BAY

TEXAS DEPARTMENT OF HOUSING AND COMMUNITY AFFAIRS OFFICE OF COLONIA INITIATIVES TEXAS BOOTSTRAP LOAN PROGRAM. Form 15 Work Write-Up

READ ONLY. Adopting Agency BSC SFM. Adopt Entire Chapter Adopt Entire Chapter as amended (amended sections listed below)

Employment Application

Statement of Existing (This is not a Permit)

Product Guide Specification

CMS, FDA and AAMI Requirements for Bicarbonate Systems Made Simple. Compiled January 2012 by AmeriWater Incorporated

ENERGY EFFICIENCY CERTIFICATION

Water Quality in East Chicago. December 12, 2016

Energy Performance Certificate

COMPETENT PERSON SCHEME SCHEME HANDBOOK

RESTAURANTS AND FOOD OUTLETS

Scottish Health Technical Memorandum 04-01: Water safety for healthcare premises: Part C: TVC Testing Protocol

HRO-50 Water Purifier

READ ONLY. Adopting Agency BSC SFM. Adopt Entire Chapter X X X Adopt Entire Chapter as amended (amended sections listed below) X X X X X X

Copyright 2017, ProVent Systems Inc., All Rights Reserved

Hong Kong Waterworks Standard Requirements For Plumbing Installation in Buildings. Revision History

The Homeowner s Building Application Checklist for Constructing a Residential Addition

SHCM SHOWER COLUMN INSTALLATION INSTRUCTIONS

2016 CALGREEN RESIDENTIAL CHECKLIST MANDATORY ITEMS City of San Carlos - Building Division 600 Elm Street, San Carlos, CA Phone:

Technology. Enabling Design. Geberit Duofix Carrier

PRACTICAL GUIDELINES TO REDUCE OUR ENVIRONMENTAL FOOTPRINT

recycle water reuse it save up to from showers & baths for flushing toilets 30% of water use

TOWNSHIP OF LOGAN 125 MAIN STREET, PO BOX 314 BRIDGEPORT, NJ FAX

PROJECT TITLE PROJECT NO.: CONTRACT TITLE UNIVERSITY OF CALIFORNIA, DAVIS CITY, CALIFORNIA

INDUSTRIAL USER WASTEWATER DISCHARGE PERMIT APPLICATION FORM

GRAY WATER RECYCLING SYSTEMS

All service lines shall conform to the following requirements:

Welfare Services. All staff are fully trained to NSQ level.

Eurobitume UK. Site Inspection for Delivery of Bitumen

Marbury Water System Lead and Copper Sampling Plan

Existing System Evaluation Report for Onsite Wastewater Systems

The effect of Building Regulations (Part L1 2002) on existing dwellings

Dŵr Cymru Welsh Water s Self-lay Policy for Water Mains and Services July 2015

TYPICAL INSTALLATION INSTRUCTIONS

PIPEWORK INSULATION. 14/ Page 1 of 10 Pipework Insulation Rev D

Table of Contents. C. Recommended Remediation Firms: upon request

PlusICE DAY NIGHT. Phase Change Material Passive Cooling Products PHASE CHANGE MATERIAL PRODUCTS LIMITED

MDH/MPCA Clandestine Lab Contractors Procedural Report

Energy Performance Certificate

Energy Performance Certificate (EPC)

Bloomington Township Public Water District User Information Packet. Water Service

Smart hot water solutions

Tuff Toilet TM. Please comply with any local government regulations that may be in force in your area when installing your new Tuff Toilet.

Harvesting the Rain An Overview of the Rainwater Collection Systems at McKinney ISD

GRAY WATER SYSTEMS (Reference California Plumbing Code Chapter 16 and 16A) Revised: 6/11/14

Recommended Amendments to the 2015 International Plumbing Code North Central Texas Council of Governments Region

Installation Address. Postcode. Purpose of the report This form to be used only for reporting on the condition of an existing installation.

Ontario s 2012 Building Code Division B, Part 7 Ontario Regulation 332/12

Murrumba State Secondary College Guidance and Careers Matters

Australian/New Zealand Standard

NUCLEAR. Nuclear Reactor Pressure Vessel Seals

Cooling Water System Inspection Process. Presented by Craig Nicks, City of Onkaparinga

TECHNICAL SHEET FOR I.P.S. PIPES AND THREADED FITTINGS

Information Delivery Manual (IDM)

Transcription:

OF C O L D A N D H O T WAT E R SYSTEMS IN RESIDENTIAL A C C O M M O D AT I O N LOG BOOK LOG BOOK

Water System Hygiene - Cold and Hot Water Systems Risk Assessment Survey and Log Book Record Name of premises Address of premises Responsible person contact phone number Name of author of report Brief description of the use of the premises, type of occupancy and any other useful notes Date of risk assessment 1

A person who has overall responsibility for water system hygiene should be appointed in writing as the responsible person and complete the table below. Status Name Phone No. Fax No. Mob No. Email address Responsible Person Deputy Engineering Manager Deputy Water Treatment Company Status Name Phone No. Fax No. Mob No. Email address Company Contact Person Management Company Laboratory 2

Introduction Where are the premises located? How much water is used in the premises each day? How many people use the premises each day? Identify if anyone is susceptible to infection Who provides your water? Generally this will be a Water Company/Authority or the premises may have its own private supply. If you have an analysis of the water, please include this in appendix 1. General water system details How does mains water enter the building? Sketch the details in appendix 1 from where it enters the building to the outlets. Include all relevant valves and fittings. What is the temperature at the first mains fed tap? How is the mains distributed around in the building? How is water heated in the building? Where and how is water used in the building? Are there any rooms where a change of use has taken place, e.g. utility room now used for storage but systems still remain? Include any notes. 3

Cold Water Storage Log The object of this section is to allow you to assess the risk associated with storing cold water in the building. You may have more than one CWSC; please complete a sheet for each cistern. Before completing this page, go to your CWSC and identify and draw the lines representing the pipes in and out of the CWSC and record them in the space below. You may wish to add an aerial or 3D view of the tank or attach photos to show additional information. CWSC details Locate and identify all the pipes entering and leaving the tank. Indicate the individual pipes on the sketch above showing approximate location. Identify the pipes on the sketch. Include the approximate diameter of the principle pipes in your drawing. Which pipes are used Copper Plastic Cold Water Storage Cistern Details Can you give the CWSC a name which describes its principle function (e.g. mains water storage tank)? Can you give the tank a number? (Label the number on the actual tank). Where is the tank located (e.g in the attic on the 5th floor)? What does the tank serve? What is the material of construction of the tank? 4

What is the material of construction of the main pipework? What is the material of construction of the ballcock? Please measure CWSC and answer the questions below. CWSC dimensions What is the length of the CWSC? What is the breadth of the CWSC? What is the height of the CWSC? What is the working volume of the CWSC? Does the capacity of the CWSC accurately match the consumption requirements of the occupancy? Condition of water in the CWSC Describe the water in the CWSC. Is it clear or murky? Is the inside of the CWSC clean? Describe the condition of the CWSC, e.g. debris, stagnant water, corrosion, surface skin, vermin. What is the temperature of the water farthest from the ballvalve? What is the temperature of the make up water? Is there good water movement? Is the CWSC fitted with a close fitting lid? Is the CWSC fitted with a screened vent? Is the CWSC fitted with effective insulation? Is the CWSC located in a cool place? Is the pipework kept away from a direct heat source? Does the calorifier s open vent return to the CWSC? Is there evidence of carry over (expansion)? 5

Is the CWSC attached to other CWSCs? - Parallel. - Series. Is it easily accessible for inspection and cleaning? Risk Assessment For this assessment the answers yes/no have been given a numerical value; please enter the number that corresponds to your answer. Is the internal condition of the tank good? y = 0, n = 2 Is the water clear? y = 0, n = 3 Is the water temperature less than 20 C? y = 0, n = 4 Is there good water movement within the tank? y = 0, n = 3 Is the CWSC capacity accurate for the occupancy? y = 0, n = 3 Does the CWSC installation fully comply with Water y = 0, n = 4 Regulation requirements? If the sum of the above choices is: < 3 Assessment is no risk. 3 to 5 Assessment is small risk. 5 to 10 Medium risk. >10 Tank presents a serious risk. Total: Tank number: Please include any additional information regarding equipment associated with the CWSC. 6

Cold Water Storage Log The object of this section is to allow you to assess the risk associated with storing cold water in the building. You may have more than one CWSC; please complete a sheet for each cistern. Before completing this page, go to your CWSC and identify and draw the lines representing the pipes in and out of the CWSC and record them in the space below. You may wish to add an aerial or 3D view of the tank or attach photos to show additional information. CWSC details Locate and identify all the pipes entering and leaving the tank. Indicate the individual pipes on the sketch above showing approximate location. Identify the pipes on the sketch. Include the approximate diameter of the principle pipes in your drawing. Which pipes are used Copper Plastic Cold Water Storage Cistern Details Can you give the CWSC a name which describes its principle function (e.g. mains water storage tank)? Can you give the tank a number? (Label the number on the actual tank). Where is the tank located (e.g in the attic on the 5th floor)? What does the tank serve? What is the material of construction of the tank? 7

What is the material of construction of the main pipework? What is the material of construction of the ballcock? Please measure CWSC and answer the questions below. CWSC dimensions What is the length of the CWSC? What is the breadth of the CWSC? What is the height of the CWSC? What is the working volume of the CWSC? Does the capacity of the CWSC accurately match the consumption requirements of the occupancy? Condition of water in the CWSC Describe the water in the CWSC. Is it clear or murky? Is the inside of the CWSC clean? Describe the condition of the CWSC, e.g. debris, stagnant water, corrosion, surface skin, vermin. What is the temperature of the water farthest from the ballvalve? What is the temperature of the make up water? Is there good water movement? Is the CWSC fitted with a close fitting lid? Is the CWSC fitted with a screened vent? Is the CWSC fitted with effective insulation? Is the CWSC located in a cool place? Is the pipework kept away from a direct heat source? Does the calorifier s open vent return to the CWSC? Is there evidence of carry over (expansion)? 8

Is the CWSC attached to other CWSCs? - Parallel. - Series. Is it easily accessible for inspection and cleaning? Risk Assessment For this assessment the answers yes/no have been given a numerical value; please enter the number that corresponds to your answer. Is the internal condition of the tank good? y = 0, n = 2 Is the water clear? y = 0, n = 3 Is the water temperature less than 20 C? y = 0, n = 4 Is there good water movement within the tank? y = 0, n = 3 Is the CWSC capacity accurate for the occupancy? y = 0, n = 3 Does the CWSC installation fully comply with Water y = 0, n = 4 Regulation requirements? If the sum of the above choices is: < 3 Assessment is no risk. 3 to 5 Assessment is small risk. 5 to 10 Medium risk. >10 Tank presents a serious risk. Total: Tank number: Please include any additional information regarding equipment associated with the CWSC. 9

Cold Water Storage Log The object of this section is to allow you to assess the risk associated with storing cold water in the building. You may have more than one CWSC; please complete a sheet for each cistern. Before completing this page, go to your CWSC and identify and draw the lines representing the pipes in and out of the CWSC and record them in the space below. You may wish to add an aerial or 3D view of the tank or attach photos to show additional information. CWSC details Locate and identify all the pipes entering and leaving the tank. Indicate the individual pipes on the sketch above showing approximate location. Identify the pipes on the sketch. Include the approximate diameter of the principle pipes in your drawing. Which pipes are used Copper Plastic Cold Water Storage Cistern Details Can you give the CWSC a name which describes its principle function (e.g. mains water storage tank)? Can you give the tank a number? (Label the number on the actual tank). Where is the tank located (e.g in the attic on the 5th floor)? What does the tank serve? What is the material of construction of the tank? 10

What is the material of construction of the main pipework? What is the material of construction of the ballcock? Please measure CWSC and answer the questions below. CWSC dimensions What is the length of the CWSC? What is the breadth of the CWSC? What is the height of the CWSC? What is the working volume of the CWSC? Does the capacity of the CWSC accurately match the consumption requirements of the occupancy? Condition of water in the CWSC Describe the water in the CWSC. Is it clear or murky? Is the inside of the CWSC clean? Describe the condition of the CWSC, e.g. debris, stagnant water, corrosion, surface skin, vermin. What is the temperature of the water farthest from the ballvalve? What is the temperature of the make up water? Is there good water movement? Is the CWSC fitted with a close fitting lid? Is the CWSC fitted with a screened vent? Is the CWSC fitted with effective insulation? Is the CWSC located in a cool place? Is the pipework kept away from a direct heat source? Does the calorifier s open vent return to the CWSC? Is there evidence of carry over (expansion)? 11

Is the CWSC attached to other CWSCs? - Parallel. - Series. Is it easily accessible for inspection and cleaning? Risk Assessment For this assessment the answers yes/no have been given a numerical value; please enter the number that corresponds to your answer. Is the internal condition of the tank good? y = 0, n = 2 Is the water clear? y = 0, n = 3 Is the water temperature less than 20 C? y = 0, n = 4 Is there good water movement within the tank? y = 0, n = 3 Is the CWSC capacity accurate for the occupancy? y = 0, n = 3 Does the CWSC installation fully comply with Water y = 0, n = 4 Regulation requirements? If the sum of the above choices is: < 3 Assessment is no risk. 3 to 5 Assessment is small risk. 5 to 10 Medium risk. >10 Tank presents a serious risk. Total: Tank number: Please include any additional information regarding equipment associated with the CWSC. 12

Hot Water System Vessel Number How is the water heated? Please include any technical information which you have available regarding the equipment used. Information on make/model/year of manufacture, can be collated and inserted in appendix 3. Which fuel is used to heat the water? Draw your hot water calorifier at appendix 2 (if there is a calorifier in the system). Add the hot water system around the calorifier/ or the water heating equipment - appendix 2 Include measurements of pipelines in and out of the calorifier. What is the temperature of the water leaving the calorifier? What is the temperature of the water returning to the calorifier? What is the temperature at any outlet after 1 minute? Which mechanical safety device prevents the hot water system from over pressure? Can the system be drained? Is the temperature in the calorifier, including the base, heated to 60 o C for an hour each day, for example using a shunt pump? Are there any scale control measures for the calorifier? Are there any dead legs/ends? Are there any redundant pipe runs? Does the calorifier have an access panel? If there is more than one calorifier, are they connected in parallel? 13

Are the hot water pipes insulated? Are the outlets scaled? Risk Assessment Insert the numerical values which correspond to your answer. What is the water temperature leaving the calorifier or water heating device? >60 C = 0 55-60 C = 3 <55 C = 10 What is the return hot water temperature? >55 C = 0 50-55 C = 3 45-50 C = 10 What is the temperature at any outlet after 1 minute? >50 C = 0 <50 C = 5 Total If the sum of the above choices is: 3 or less minimal risk. 3-9 medium risk. >9 high risk. Vessel number Please include any additional information regarding equipment associated with the hot water system. 14

Hot Water System Vessel Number How is the water heated? Please include any technical information which you have available regarding the equipment used. Information on make/model/year of manufacture, can be collated and inserted in appendix 3. Which fuel is used to heat the water? Draw your hot water calorifier at appendix 2 (if there is a calorifier in the system). Add the hot water system around the calorifier/ or the water heating equipment - appendix 2 Include measurements of pipelines in and out of the calorifier. What is the temperature of the water leaving the calorifier? What is the temperature of the water returning to the calorifier? What is the temperature at any outlet after 1 minute? Which mechanical safety device prevents the hot water system from over pressure? Can the system be drained? Is the temperature in the calorifier, including the base, heated to 60 o C for an hour each day, for example using a shunt pump? Are there any scale control measures for the calorifier? Are there any dead legs/ends? Are there any redundant pipe runs? Does the calorifier have an access panel? If there is more than one calorifier, are they connected in parallel? 15

Are the hot water pipes insulated? Are the outlets scaled? Risk Assessment Insert the numerical values which correspond to your answer. What is the water temperature leaving the calorifier or water heating device? >60 C = 0 55-60 C = 3 <55 C = 10 What is the return hot water temperature? >55 C = 0 50-55 C = 3 45-50 C = 10 What is the temperature at any outlet after 1 minute? >50 C = 0 <50 C = 5 Total If the sum of the above choices is: 3 or less minimal risk. 3-9 medium risk. >9 high risk. Vessel number Please include any additional information regarding equipment associated with the hot water system. 16

Cold and Hot Water Distribution Describe how cold water is distributed in the premises. Do a simple sketch of the cold water distribution if a drawing is not already available. Insert this sketch in appendix 2. Describe how hot water is distributed in the premises. Do a simple sketch of hot water distribution. Insert this sketch in appendix 2. Are there any showers in the premises? Are the showers regularly maintained and shower heads descaled and disinfected quarterly? From measuring and recording on a temperature record sheet, are there any abnormal temperatures? Are the cold water pipes insulated? Is there any redundant pipework? Are there any obvious deadlegs (lengths of pipeline where water will stand for prolonged periods of time)? Where supplies feed fitments are used infrequently, are they: Flushed through on a weekly basis? Or purged of stagnant water before use? Are there any situations where the hot and cold pipes run beside each other and affect each other s temperature? Are thermostatic mixing valves used? If yes, are they as close as possible to the point of use? Please include any additional information regarding equipment associated with the hot water system. 17

Recommendation for Improvements Recommendations for the improvement for the following are in appendix 6. CWSC(s). Hot water systems. Hot and cold water supply. When the assessments have been made and a list of improvements identified, improvement work should be noted and listed. Completion certificates or proof that work has been done should be included in appendix 4. 19

Appendix 1 Mains Water Supply Please include in your pocket folder(s) all information relating to the water supply to the building. Include a simple sketch of a pipework layout showing any relevant valves and fittings. 20

Appendix 2 Cold and Hot Water Distribution Diagrams Please include all diagrams which show how cold and hot water is distributed within the building. 21

Appendix 3 Equipment Details Please include in your plastic folder(s) all information relating to the water supply to the building. Include a simple sketch of a pipework layout showing any relevant valves and fittings, incorporating Dimensions of calorifier. Use of pump(s) for secondary circulation. Use of shunt pump. Also include in the folder manufacturer s operating instructions, service schedules etc. 22

Appendix 4 Disinfection Completion Certificates All disinfection completion certificates should be inserted in the pocket folder(s). 23

Appendix 5 Analytical Test Results All results of tests on any samples taken from the water system should be included. 24

Appendix 6 6.1 Limitations of assessment 25

Appendix 6.2 Risk Assessment Summary of Recommendations Use this table to record your recommendations. Recommendations Priority Planned By whom Date completion completed Cold water storage cistern Hot water system Calorifiers Cold and hot water distribution Showers Water Softener Record System Priority: 1 = within 1 month 2 = 1-3 months 3 = 3-6 months 4 = 6-12 months 5 = 12-24 months 26

Appendix 6.3 Temperature Monitoring Log Client: Site: Date: Location Mains Cold Hot Cwsc C fier C fier Engineer s return flow signature CWSC 3rd floor gents WC 2nd floor gents WC 1st floor gents WC Cleaners cupboard Calorifier Bathroom1 floor 1 Bathroom 5 floor 2 Bathroom 9 floor 3 Main kitchen Requirements: Tanks - <20ºC Hot - At least 50ºC within 1 minute Cold - <20ºC After 2 minutes Mains - <20ºC After 2 minutes 27

OF COLD AND H O T WAT E R S Y S T E M S I N R E S I D E N T I A L A C C O M M O D AT I O N BPEC Services Ltd offers training manuals in the following areas: GAS CCN1 Core Domestic Gas Safety Domestic Gas Appliances (combined): CEN1, CKR1, HTR1, WAT1, DAH1, MET1 WATER Unvented Hot Water Storage Systems L1 (England and Wales) Unvented Hot Water Storage Systems J (Scotland) Water Regulations Water Byelaws (Scotland) Water System Disinfection Risk Assessment of Cold and Hot Water Systems in Residential Accommodation GOOD BUSINESS GUIDES Part 1: Getting and Keeping Customers in the Domestic Market Part 2: Selection and Recruitment of Craft Operatives Part 3: Basic Finance and Business Planning Part 4: Succeed in the Plumbing/Heating industry by putting People at the Heart of your Business Employer s Guide: Succeed in the Plumbing/Heating industry by putting People at the Heart of your Business BUSINESS TRAINING ICT Computer Training Programme BPEC SERVICES LTD 2 Walker Street, Edinburgh EH3 7LB Tel: 0845 644 6558 Fax: 0131 226 7638 Email: services@bpec.org.uk www.bpec.org.uk