S7 rhombos. expanded metal ceiling. Product data sheet. durlum.us. Your contact for North America

Similar documents
SYSTEM S7-RHOMBOS INSTALLATION MANUAL

Metal ceilings. OWAtecta. OWAtecta Why metal ceilings. Planning with OWAtecta Variety formation of the ceiling

Metal ceilings. OWAtecta. OWAtecta Why metal ceilings. Planning with OWAtecta Variety formation of the ceiling

Student Services & Classroom Addition

QUICK-LOCK QUICK-LOCK. A complete survey of all Quick-Lock ceiling systems. QUICK-LOCK Ceiling systems. QUICK-LOCK Cross-Lock.

Ecophon Focus Dg. System range. XL 1200x x x600. Size, mm. XL 1800x600. XL 2000x x600 T24 Thickness Inst. Diagr.

WALL CLADDING. Gema System W-H 1100 CEILING&WALL SYSTEMS. Between us, ideas become reality

ifix INSTALLATION MANUAL PV flat roof installation system Version

A. This Section includes acoustical panel ceilings installed with exposed suspension systems.

XLnt Panels. Super-size your ceiling

LINEAR METAL CEILINGS Section

SECTION NON-STRUCTURAL METAL FRAMING

Ecophon Advantage A. and accessories. The Connect grid is manufactured from galvanized steel.

Ecophon Advantage E. covered with glass tissue. The edges are painted.

SECTION ACOUSTICAL PANEL CEILINGS

PRESTON HEALTH SERVICES ARCHITECT'S NO. 2700

Section Wood Grille Ceiling Panels

EI 30 barriere Self contained fire protection EI 30 from above and below smoke impervious EN

Concepts. Products. Service. Quality Taped. Lindner Cassette Ceilings

Tender specification KLAUS Multiparking TrendVario 4300

Technical data sheet Number 04 / updated November 2008

METALWORKS R-H215 HOOK ON

Ecophon Focus E. Connect grid and accessories. The grid is manufactured from galvanized steel.

Concepts. Products. Service. Partitions Lindner Logic

STANDARD PRODUCTS - CUSTOM LOOK

All panels can be supplied in a range of styles, to suit the applications pictured below.

GLASSWALL SPECIFICATIONS

Ceilings without Filler. VoglFuge. Create perfect acoustic designer ceilings with the VoglFuge system. with air purification effect as standard

system 130 modular lay-in tiles (exposed grid) SAS International +44 (0)

SECTION VIBRATION ISOLATION

SECTION HANGERS AND SUPPORTS FOR PLUMBING

system 200/205 modular hook-on tiles (concealed grid) SAS International +44 (0)

ACOUSTICAL WALL TREATMENT SECTION 09840

Rockfon System T24 Stepped Z D

General technical terms and conditions of TAIM e.v. for. M e t a l c e i l i n g s

Technical data sheet Number 07 / updated May Revision / August 2012

UNIVERSITY SERVICES ANNEX James Madison University Harrisonburg, Virginia State Project Code: Architect s Project Number:

SECTION OVERHEAD COILING FIRE DOORS MODEL 662 OVERHEAD COILING COUNTER FIRE DOORS WITH INTEGRAL FRAME

Hoesch isodach integral Technical information

Product Guide Specification

SECTION IMPACT RESISTANT WALL PROTECTION

ROCKFON SYSTEM T24 A/E

SECTION COLD-FORMED METAL FRAMING

SECTION ENTRANCE FLOOR GRILLES STAINLESS STEEL GRATING

SECTION CRL50 AND CRL51 HEAVY GLASS TOP HUNG SLIDING DOOR SYSTEMS

Decks/Liners. structural steel decks and liner trays.

Noise-Foil Acoustic Metal Panels Sound Absorption Systems for Industry & Commerce

ROCKFON SYSTEM T24 X

KNAUF DANOLINE KRAFT ACOUSTIC LINING

AEROFOILS 200AF-450AF. Sun Control Systems

Suspended ceiling. Lauder INEA. Process Bois

Specifiers: Click on the icon in the WORD toolbar to reveal detailed instructions

Section SoundPly LR M25 Acoustic Ceiling Panels

Ecophon Hygiene Meditec A

SYSTEMS 03/2013. Between us, ideas become reality. Mesh Metal Ceiling

SECTION ACOUSTICAL PANEL CEILINGS PART 1 - GENERAL

Slab SOPHI STI CATED & SI MPLE. pat e n t p e n d i n g

SECTION ACCORDION FOLDING PARTITIONS

Gyptone edge D1 system Installation manual

Acoustic-Lightboard. Meets highest demands in sound and fire protection. when it matters!

ALL-ALUMINUM DOOR & WINDOW FRAMING

SECTION [ ] COILING COUNTER DOORS. Display hidden notes to specifier. (Don't know how? Click Here)

SECTION Summit Phenolic Lockers (Solid Phenolic Lockers)

Ecophon Focus Wing. galvanized steel. The system is patented in Sweden and International patent pending.

Fire protection, soundproofing and thermal insulation

80/90/100/120/mm POST Standard Medium Heavy Extra Heavy

DID YOU KNOW THAT. the perforation holes in gypsum boards provide several acoustical effects: sound absorption, sound diffusion and sound reflection?

DBI-SALA Uni 8 Overhead Horizontal Lifeline Cable System SECTION HORIZONTAL FALL PROTECTION - OVERHEAD CABLE

Model 4010 Individual Panels / Curve & Diverter

CS SERIES. Access Flooring Made Affordable.

Exterior. Flexible durability

HANGERS AND SUPPORTS FOR HVAC PIPING AND EQUIPMENT SECTION HANGERS AND SUPPORTS FOR HVAC PIPING AND EQUIPMENT

SECTION HANGERS AND SUPPORTS FOR ELECTRICAL SYSTEMS

Tate Access Floors, Inc. ConCore 1250 Access Floor Panel Bolted Stringer Understructure System

SECTION SOLID COLOR REINFORCED COMPOSITE TOILET PARTITIONS

SECTION LINEAR WOOD CEILINGS

ROCKFON SYSTEM ULTRALINE E

Logistics and industry. Consignment sales

B. Shop Drawings: For metal lockers. Include plans, elevations, sections, details, and attachments to other work.

PLANK METAL CEILING SYSTEMS

Wall Louvers (10200)

mounting systems applications overview

Allround Scaffolding. Layher Allround Bridging System Instructions for Assembly and Use. Modular truss system for wide spans

DIVISION: FINISHES SECTION: SUSPENSION SYSTEMS SECTION: ACOUSTICAL CEILING SUSPENSION ASSEMBLIES REPORT HOLDER:

Section HIGH-TENSION Stretched-Fabric Wall Systems SoftWalls, Inc.

Manufacturers of Custom Acoustical Ceiling and Wall Products

Layher. Keder Roof and Keder Hall. More Possibilities. The Scaffolding System. Layher Keder Roof and Keder Hall Instructions for Assembly and Use

Installation Guide Wall Panels

DIVISION 15-MECHANICAL SECTION SUPPORTS AND ANCHORS PN PART 1 - GENERAL 1.01 SECTION INCLUDES. A. Pipe and equipment support systems.

Type II Environmental Declaration according ISO 14021:2001/A1:2011

C. Concrete Inertia Bases: Drawings showing required concrete steel reinforcing, construction details, and dimensions.

PH6000. Key Features

Tate Access Floors, Inc. All Steel 1000 Access Floor Panel 600 mm Bolted Stringer Understructure System

PRODUCT BROCHURE ARCHITECTURAL FABRICATIONS

SECTION CRC575 UNITARY CLEANROOM WALL SYSTEM STUDLESS CLEANROOMWALL SYSTEM ME175 3-IN-1 CLEANROOM WALL SYSTEM

B. American Society for Testing and Materials: 1. ASTM F708 - Standard Practice for Design and Installation of Rigid Pipe Hangers.

Architectural Specifications, Section Phenolic Lockers

GLASS WALL SPECIFICATIONS

Product data sheet RESOPLAN HPL as per EN 438-6

ARMSTRONG SHALL NOT BE LIABLE FOR ANY DAMAGES ARISING OUT OF THE USE OF ANY OF ITS GUIDE SPECIFICATIONS. SECTION PERIMETER TRANSITION SYSTEM

Transcription:

S7 rhombos expanded metal ceiling Your contact for North America Product data sheet

2 4 1 3 1 2 U1045 U 1044 FK V 3 4 U 1042 U 1041 N 2

The open expanded metal ceiling S7-RHOMBOS offers a host of applications. The is especially suited for sales areas, transport building or other applications requiring ceilings with integrated sign-posting. Its solid design also makes it suitable for sports halls, wall cladding or alike. S7-RHOMBOS is distinguished by highly flexible design options. With its symmetrical panels, the S7 hook-in system with a front-sided joint of 13/32 [10mm] standard allows for easy planning and is easy to dismount from the bottom side at each point. Furthermore, the system can be supplied sound-proof and sound-absorbing according to your needs. The metal ceiling contributes directly to Green Building / LEED certification. durlum S7-RHOMBOS expanded metal ceilings fall under the general Master Format section 09 50 00 ceilings. When the S7-RHOMBOS ceiling panels are supplied with sound absorption materials, 09 51 33 Acoustical Metal Pan Ceilings is possible. Surface Galvanized steel, aluminium, stainless steel. The thickness of the material depends on the static requirements. The galvanized steel and aluminium can be powder-coated white matt [similar to RAL 9016] or according to customer specifications. The coating thickness is approx. 60 µm. The aluminium can also be supplied coil anodized or mirror polished. Stainless steel expanded metal panels are available brushed or mirror polished. Dimensions Module size Normally expanded: max. 3-7 8-3 [1100 2500mm] Flat rolled: max. 2-8 8-3 [800 2500mm] Larger dimensions on request. mesh and acoustics durlum offers expanded metal panels with medium sized mesh M260_1.5 [open area ~66%] or M400 [open area ~50%] as standard and without acoustic effectiveness. Other mesh types may be available upon request. Expanded metal panels can be supplied with black acoustic fleece [closed area]. Fire performance In accordance with ASTM E84 Flame Spread Index for steel is 25 or less and Smoke Developed Index for steel is 50 or less. green building durlum metal panels contribute directly to LEED and other GREEN BUILDING certifications. Typically applicable credits under LEED v4: Recycled Content post- & pre-consumer info VOC Emissions conformity with VOC requirements Acoustic Performance sound absorption with acoustic fleece Environmental Product Declaration available No substances as outlined in the US Living Building v.3 Red List are internationally used. Learn more: greenbuilding@ SYSTEM details U 1370 screw + nut 1/4 [6mm] U 1045 Module adapter for U1040/W2053 Threaded rod 1/4 [M6] Retaining and fixation clip U 1044 FK 4"[~102mm] 2 13/16" [~72mm] panel length joint / Q + R Standard 13/32 [10mm] 3

meshes M260_1.5 Medium Mesh Mesh length Mesh width Web width Web thickness Open area 1 3/32 [28 mm] 15/32 [12 mm] 3/32 [2 mm] 1/16 [1.5 mm] 66.6 % M400 Medium Mesh Mesh length Mesh width Web width Web thickness Open area 1 23/32 [44 mm] 15/32 [12 mm] 1/8 [3 mm] 1/16 [1.5 mm] 50 % perimeter details 25/32 20mm] 25/32 [20mm] 25/32 [20mm] 25/32 [20mm] F 025 wall angle For perimeter panels, to be cut on site F 025 wall angle For lay-on perimeter panels F 2025 shadow gap wall angle For perimeter panels, to be cut on site F 2025 shadow gap wall angle For lay-on perimeter panels 4

Installation The expanded metal panels are hooked form-fitting and tension free into a special substructure, the parts of which must be approved by the manufacturer of the expanded metal panels. Demounting without requiring tools is assured. The substructure consists of form-punched, L-shaped primary carriers acting as cross bracing [primary profile]. They are suspended rigidly from the bare ceiling with nonius suspension elements or threaded rods using officially approved anchors. The primary profiles are to be connected together at the longitudinal joints using U 1041 connectors. The primary profiles are joined to the walls using the wall bracket U 1042. The spacing of primary carrying profiles is determined by the applicable market standards and project requirements (static loads) and is to be determined and checked by the contractor. Ensure horizontal and flush alignment. The primary profiles are connected to the secondary profiles using U 1045 modul adapters. The secondary profiles are connected together at the longitudinal joint using connector V. U 1042 is used for joining the secondary profiles to the wall. The spacing of the secondary profiles is to be adjusted precisely to the length of the expanded metal panels to ensure that the panels are positioned tension free in the system. Ensure horizontal and flush alignment. The expanded metal panels can be joined to the wall using the following wall bracket profiles: Perimeter trim F 025 Perimeter trim F 2025 Please note Installation must be carried out by qualified and trained staff according to the instructions for installation. These are available as download at www.. technical standards The parts comply with DIN EN 13964 as well as ASTM C635 and ASTM E1264. Production complies with the TAIM and CISCA guidelines and the durlum works standards and is quality controlled by the TÜV according to ISO 9001:2008 and ISO 14001:2004. cleaning As standard, durlum ceiling panels are made with an electrostatic polyester powder coating, thus providing them with a long-term finish. The powder-coated surface should always be cleaned wearing clean gloves. First clean it with a soft, dry cloth. If dirt cannot be removed by this procedure, the cloth can also be moistened, with the addition of a ph-neutral cleaner [household detergent], if necessary. Contact of the powder coating with both alkaline and acid substances must be avoided. Metallic powder coatings show a particularly sensitive reaction. Due to the risk of a change in hue or effect, for metallic coatings a suitability test must be performed. More information: MANUFACTURER CONTACT durlum GmbH An der Wiese 5 79650 Schopfheim Germany Phone +49.7622.3905.0 info@ FORMGLAS SPECIALTY SOLUTIONS LTD. 181 Regina Road Vaughan, Ontario Canada L4L 8M3 Toll Free +1.866.635.8030 Main +1.416.635.8030 durlum@formglas.com 5