SECTION ORNAMENTAL ALUMINUM RAILING. ** NOTE TO SPECIFIER ** Superior Aluminum Products, Inc.; Ornamental aluminum railing products.

Similar documents
SECTION ORNAMENTAL ALUMINUM RAILING. ** NOTE TO SPECIFIER ** Superior Aluminum Products, Inc.; Ornamental aluminum railing products.

SECTION ORNAMENTAL ALUMINUM RAILING. ** NOTE TO SPECIFIER ** Superior Aluminum Products, Inc.; Ornamental aluminum railing products.

Aluminum Component Pipe Railings

SECTION [ ] COILING COUNTER DOORS. Display hidden notes to specifier. (Don't know how? Click Here)

SECTION DECORATIVE METAL AND GLASS RAILING

MASTERSPEC - SHORT FORM. B. See Division 5 Section "Metal Stairs" for steel tube railings associated with metal stairs.

SPECIFICATION SECTION 05515: LADDERS O Keeffe s Aluminum Ladders

SECTION CRL50 AND CRL51 HEAVY GLASS TOP HUNG SLIDING DOOR SYSTEMS

SECTION ENTRANCE FLOOR GRILLES STAINLESS STEEL GRATING

ALL-ALUMINUM DOOR & WINDOW FRAMING

SECTION EXPANSION CONTROL

SPECIFICATIONS: Architectural Aluminum Railings

SECTION EXPANSION CONTROL

SECTION LIGHT DUTY SLIDING AND STACKING GLASS DOOR SYSTEMS

A. Access doors and frames are part of an access door and frame allowance.

Section PANEL SIGNAGE

SECTION FOOD DISPENSING EQUIPMENT- SNEEZE GUARDS AND PARTITION POSTS

SECTION HEAVY GLASS TOP HUNG SLIDING BI-FOLD DOOR SYSTEMS

SECTION GLASS BALUSTRADE RAILING SYSTEMS

PRESTON HEALTH SERVICES ARCHITECT'S NO. 2700

SECTION ELEVATED BLEACHERS (Angle Frame Semi-Closed Deck)

Series - 1

by Rollfab Metal Products

A. ASTM C190 - Test Method for Tensile Strength of Hydraulic Cement Mortars

SECTION ALUMINUM RAILINGS

SECTION TOILET COMPARTMENTS. A. Section Metal Fabrications: Concealed steel support members.

SECTION LAGUNA SERIES TOP HUNG SLIDING DOOR SYSTEM

Northpointe Renovation EPN #1701 F/A Project #17027 September 8, 2017

Product Guide Specification

A. Pre-engineered, pre-finished extruded aluminum Pavilions.

SECTION OVERHEAD COILING FIRE DOORS MODEL 662 OVERHEAD COILING COUNTER FIRE DOORS WITH INTEGRAL FRAME

SECTION SECTIONAL OVERHEAD DOORS 522 SERIES ALUMINUM SECTIONAL OVERHEAD DOORS. Display hidden notes to specifier. (Don't know how?

A. The extent of extruded aluminum walkway covers is shown on the Drawings and as specified herein.

SECTION ALUMINUM GATES

Architectural Specifications, Section Phenolic Lockers

SPECIFICATIONS SECTION FLOOD CONTROL GATES. A. ASTM C 39 - Standard Test Method for Compressive Strength of Cylindrical Concrete Specimens.

SECTION ALUMINUM HANDRAILS AND RAILINGS

SECTION IMPACT RESISTANT WALL PROTECTION

SECTION SECTIONAL OVERHEAD DOORS

Specifiers: Click on the icon in the WORD toolbar to reveal detailed instructions

SECTION EXTERIOR GRILLS AND SCREENS

SECTION STAINLESS STEEL FLEXIBLE CABLE MESH. Show hidden Specifier Notes for best results

SECTION ALUMINUM WINDOWS

SECTION Summit Phenolic Lockers (Solid Phenolic Lockers)

SECTION DECORATIVE METAL FENCES AND GATES

SECTION RADIATION SHIELDING ENCLOSURE Low Intensity Radiation Protection

American Metal Specialties, Inc.

Union County Vocational - Technical Schools Scotch Plains, New Jersey

SECTION PIPE AND TUBE RAILINGS PART 1- GENERAL 1.1 RELATED DOCUMENTS 1.2 SUMMARY 1.3 PERFORMANCE REQUIREMENTS

SECTION TURBINE VENTILATORS

SECTION ACCORDION FOLDING PARTITIONS

SECTION METAL FABRICATIONS

1.2.1 Section Cold-Formed Metal Framing: Metal framing for support of aluminum soffits.

CONCRETE STEPS, HANDRAILS, AND SAFETY RAIL

Ultra Aluminum Fence, Rail & Gate Specifications

SECTION CHAIN LINK FENCES AND GATES (PARK)

B. Samples for Initial Selection: For each type of impact-resistant wall protection unit indicated.

SECTION DIRECTORIES

PIPE AND TUBE RAILINGS

ACOUSTICAL WALL TREATMENT SECTION 09840

SPECIFICATIONS - DETAILED PROVISIONS Section Stainless Steel Sluice Gates C O N T E N T S

DBI-SALA Uni 8 Overhead Horizontal Lifeline Cable System SECTION HORIZONTAL FALL PROTECTION - OVERHEAD CABLE

SECTION ROOF SPECIALTIES

SECTION WATERTIGHT FLOOD PLANKS. A. ASTM A 36 - Standard Specification for Carbon Structural Steel.

B. Polyethylene samples shall be submitted for Owner approval of color and quality.

Aluminum Flush Doors and Frames SPECIFICATIONS. Section [8120] PART 1 GENERAL

This guide can be used to prepare a specification for incorporating free standing jib cranes into a competitively bid construction project.

METAL HANDRAILS AND RAILINGS. A. Properly identified manufacturer's literature, including shop and erection drawings before starting work.


ST. JOHNS COUNTY ARCH. PROJ. NO SECTION PREFABRICATED ALUMINUM CANOPIES PART 1 - GENERAL 1.1 RELATED DOCUMENTS

UNIFIED FACILITIES GUIDE SPECIFICATIONS

MODERNFOLD GWS 100SR-G MOVEABLE GLASS WALLS

SECTION ORNAMENTAL HANDRAILS AND RAILINGS

B. Shop Drawings: For metal lockers. Include plans, elevations, sections, details, and attachments to other work.

SECTION CHAIN LINK FENCES AND GATES

The City of Winnipeg SECTION ST. VITAL LIBRARY RENOVATION PROJECT 6 FERMOR AVE. Page 1 of 5

Student Services & Classroom Addition

SECTION HANGERS AND SUPPORTS FOR ELECTRICAL SYSTEMS

SECTION ALUMINUM STORM WINDOWS

PROJECT LOCATION SECTION COPPER METAL PLATE WALL PANELS

SECTION PANEL AND POST AND PYLON SIGNAGE. 1. Non-illuminated Panel and Post signs. 2. Internal illumination Pylon (Cabinet and Post) signs.

Façade Architectural Wall Panel System - Guide Specification 3/11/2017 SECTION FRAMED DECORATIVE PANEL SYSTEMS PART 1 - GENERAL 1.

Specifiers: Click on the icon in the WORD toolbar to reveal detailed instructions

SECTION RESIDENTIAL OVERHEAD DOORS SIGNATURE COLLECTION WOOD GARAGE DOORS

University Apartments on Brooklyn PROJECT MANUAL

SECTION METAL FLOOR PLATE STAIRS

This guide can be used to prepare a specification for incorporating free standing jib cranes into a competitively bid construction project.

Houston Community College 3200 Main Parking Garage November 15, 2010 Houston Community College

FL200 13/4 x41/2 GUIDE SPECIFICATION. Non-Thermal Storefront

SHORING & UNDERPINNING 02250

A-Series Aluminum Gantry Crane

SECTION ACOUSTICAL PANEL CEILINGS

GUIDE SPECIFICATION EXETER SECURITY SHIELD SECURITY WINDOW BARRIER SYSTEM

SECTION EPOXY TERRAZZO

PIPE AND TUBE RAILINGS

SECTION VIBRATION AND SEISMIC CONTROLS FOR ELECTRICAL SYSTEMS

SECTION ROOF ACCESSORIES

SECTION BRICK FACED ARCHITECTURAL PRECAST CONCRETE. Display hidden notes to specifier by using Tools / Options / View / Hidden Text.

GUIDE SPECIFICATION EXETER VERSA SHIELD SECURITY SCREEN SYSTEM

SECTION CHAIN-LINK FENCES AND GATES 02821/1

Transcription:

SECTION 05720 ORNAMENTAL ALUMINUM RAILING ** NOTE TO SPECIFIER ** Superior Aluminum Products, Inc.; Ornamental aluminum railing products. This section is based on the products of Superior Aluminum Products, Inc., which is located at: 555 E. Main St. P. O. Box 430 Russia, OH 45363 Phone: 937-526-4065 Fax: 937-526-3904 www.superioraluminum.com Email: info@superioraluminum.com [click Here] for additional information. Superior Aluminum s product lines are being continuously improved and refined. When you install our columns, railings, or fence on your property, you can be certain that you are receiving the best possible offering on the market. A key component that sets Superior Aluminum apart from other column, railing, and fence providers is an impeccable record of customer service. From concept design and product selection, to production and delivery, a Superior representative is committed to your satisfaction at every step of the way. Superior Aluminum employs a team of full time engineers to create CAD drawings of each project. These CAD drawings are followed during manufacturing to create a railing system that ensures a perfect fit for your project, and makes installation simple and efficient while limiting field fabrication. 05720-1

Superior Aluminum products are designed to meet local, state, and federal building codes, including the Americans with Disabilities Act. Superior columns feature a load-bearing design that will support your structure and keep all parties safe. Superior Aluminum has been family owned and operated since 1956, now in its 3rd generation of business management. You can be assured that the service you receive from Superior will be second to none, as this longevity is a testament to the dedication and pride we have in our work. The materials that go into Superior's columns, railings, and fence are sourced from the United States and Canada, as well as recycled content, and the finished products are fabricated and assembled at our manufacturing facility located in Ohio. This means you can be confident in the quality and craftsmanship you receive. This also means that Superior products qualify for LEED MR 4 credits for recycled content and possibly LEED MR5 credit for locally sourced material. PART 1 GENERAL 1.1 SECTION INCLUDES A. Aluminum Pipe Railing 1.2 RELATED SECTIONS ** NOTE TO SPECIFIER ** Delete any sections below not relevant to this project; add others as required. A. Section 03300 Cast-In-Place Concrete: Placement of sleeves cast in concrete. B. Section 05500 - Metal Fabrications: Furnishing of sleeves cast in concrete. 05720-2

C. Section 05510 - Metal Stairs D. Section 05520 - Aluminum Pipe Railings 1.3 REFERENCES ** NOTE TO SPECIFIER ** Delete references from the list below that are not actually required by the text of the edited section. A. ANSI A1264.1 - Safety Requirements for Workplace Floor and Wall Openings, Stairs, and Railing Systems. B. ASTM B 211 - Standard Specification for Aluminum and Aluminum-Alloy Bar, Rod, Wire. C. ASTM B 247 - Standard Specification for Aluminum and Aluminum Die Forgings, Hand Forgings and rolled Ring Forgings. D. ASTM B 429 - Standard Specification for Aluminum-Alloy Extruded Structural Pipe and Tube. E. ASTM E 935 - Standard Test Methods for Permanent Metal Railing Systems and Rails for Buildings. 1.4 DESIGN / PERFORMANCE REQUIREMENTS A. Comply with requirements of building authorities having jurisdiction in Project location and the following: 1. Handrail Standard: ANSI A1264.1 2. Occupational Safety and Health Administration - 29 CFR 1910.23 - Guarding floor and wall openings. 05720-3

B. Structural Performance: Engineer, fabricate, and install handrails, guardrails, and railing systems to withstand, when tested per ASTM E 935, loadings required by applicable building and safety codes but not less than the following: C. Design Loads: Design to the following requirements. Concentrated and uniform loading need not be applied simultaneously. ** NOTE TO SPECIFIER ** Edit the following paragraphs as required. Superior railings are typically designed for ICBO loadings of 200 pound concentrated and 50 pound uniform, however railings can be fabricated to meet other code loading conditions. Codes vary in method of application and magnitude of load. Governing code should be checked for specific requirements. Horizontal and vertical concentrated load test of railing systems should be conducted in accordance with ASTM E 935. 1. Uniform load: 50 pounds per foot (74.3 kg/m) applied at the top in any direction.. 2. Concentrated load: 200 pounds (90.6 kg) applied at the top in any direction. 1.5 SUBMITTALS A. Submit under provisions of Section 01300. B. Product Data: Manufacturer's data sheets on each product to be used, including: 1. Preparation instructions and recommendations. 2. Details of material and construction. 3. Storage and handling requirements and recommendations. 4. Installation methods and requirements. C. Shop Drawings: Submit shop drawings for fabrication and installation of ornamental metalwork. Include plans, elevations and detail sections. Indicate materials, methods, finishes and types of joinery, fasteners, anchorages and accessory items. 05720-4

D. Load Tests: Submit test results from ASTM E 935 conducted on the manufacturer s supplied system indicating compliance with required structural loading. ** NOTE TO SPECIFIER ** Delete selection samples if colors have already been selected. E. Selection Samples: For each finish product specified, two complete sets of color charts representing manufacturer's full range of available colors and patterns. F. Manufacturer's Certificates: Certify products meet or exceed specified requirements. G. Closeout Submittals: Provide manufacturer s maintenance instructions that include recommendations for periodic cleaning and maintenance of all components. 1.6 QUALITY ASSURANCE A. Manufacturer Qualifications: Minimum 3 years documented experience producing systems specified in this section. ** NOTE TO SPECIFIER ** Include a mock-up if the project size and/or quality warrant taking such a precaution. The following is one example of how a mock-up on a large project might be specified. When deciding on the extent of the mock-up, consider all the major different types of work on the project. Note that a mockup will represent an additional cost for the project. Delete if not required. B. Mock-Up: Provide a mock-up for evaluation of surface preparation techniques and application workmanship. 1. Finish areas designated by Architect. 2. Do not proceed with remaining work until workmanship, color, and sheen are approved by Architect. 3. Refinish mock-up area as required to produce acceptable work. 4. Accepted mock-ups shall be comparison standard for remaining Work 05720-5

1.7 DELIVERY, STORAGE, AND HANDLING A. Store products in manufacturer's unopened, properly labeled, original packaging until ready for installation. B. Store components to avoid damage from moisture, abrasion, and other construction activities. 1.8 SEQUENCING A. Ensure that products of this section are supplied to affected trades in time to prevent interruption of construction progress. 1.9 PROJECT CONDITIONS A. Maintain environmental conditions (temperature, humidity, and ventilation) within limits recommended by manufacturer for optimum results. Do not install products under environmental conditions outside manufacturer's absolute limits. B. Field Measurements: Take measurements of actual dimensions where necessary for fit without gaps. Indicate measurements on shop drawings. PART 2 PRODUCTS 2.1 MANUFACTURERS A. Acceptable Manufacturer: Superior Aluminum Products, Inc.; 555 E. Main St., P. O. Box 430, Russia, OH 45363. Phone: 937-526-4065. Fax: 937-526-3904. Email: info@superioraluminum.com. Web: www.superioraluminum.com. 05720-6

** NOTE TO SPECIFIER ** Delete one of the following two paragraphs; coordinate with requirements of Division 1 section on product options and substitutions. B. Substitutions: Not permitted. C. Requests for substitutions will be considered in accordance with provisions of Section 01600. 2.2 HORIZONTAL PIPE RAILINGS ** NOTE TO SPECIFIER ** Series 500 and Series 550 Horizontal Pipe and Pipe Picket Railing were developed to meets state, local and federal codes. Post spacing shall not exceed 6 feet on center. Railings can be manufactured in a manner that fits code requirements in commercial, industrial, or residential settings. Pipe railing can also be manufactured as a strict handrail system, for use directly on a wall (or other existing structure), or in conjunction with either a full pipe guardrail system or full square guardrail system in order to meet code requirements. A. Horizontal Pipe Rail Guard Railing Series 500: 1-1/2 inch (3.81 cm) Schedule 40 pipe with 1.9 inch (4.83 cm) outside diameter runs between posts and utilizes concealed fasteners. No joints shall be fastened via welding. All top rail shall be continuous through the full length of the system. 1. Round posts a. 1-1/2 inch Schedule 40 pipe (3.81 cm) with 1.9 inch (4.83 cm) outside diameter with reinforcement rebar inserts ** NOTE TO SPECIFIER ** Select height required and delete the one not required. 2. Height: a. Residential: 36 inches (91.44 cm) b. Commercial: 42 inches (106.68 cm) c. As indicated on the Drawings 05720-7

** NOTE TO SPECIFIER ** Select the design(s) required from the following paragraphs and delete those not required. All design styles are available with as little as 2 horizontal lines of pipe and as many as 8 horizontal lines of pipe. 3. Design a. Straight Rail Design: As indicated b. Step Rail Design: As indicated c. Toe-Plate Design: As indicated d. Radius Design: As indicated e. As indicated on the Drawing 4. Component Parts: a. Provide all connecting components and fittings as required. B. Horizontal Pipe Picket Railing Series 550: 1-1/2 inch Schedule 40 (3.81 cm) pipe with 1.9 inch (4.83 cm) outside diameter run between posts and utilizes concealed fasteners. Pickets are 3/4 inch (1.9 cm) round pipe spaced at 4.5 inch (11.43 cm) on center and run between the top and bottom rail utilizing concealed fasteners. Neither horizontal or vertical components shall be fastened via welding. All top rail shall be continuous through the full length of the system. 1. Round posts a. 1-1/2 inch Schedule 40 pipe (3.81 cm) with 1.9 inch (4.83 cm) outside diameter with reinforcement rebar inserts ** NOTE TO SPECIFIER ** Select height required and delete the one not required. 2. Height: a. Residential: 36 inches (91.44 cm) b. Commercial: 42 inches (106.68 cm) c. As indicated on the Drawings ** NOTE TO SPECIFIER ** Select the design(s) required from the following paragraphs and delete those not required. All design styles are available with as little as 2 horizontal lines of pipe and as many as 4 horizontal lines of pipe. 3. Design a. Straight Rail Design: As indicated 05720-8

b. Step Rail Design: As indicated c. Toe-Plate Design: As indicated d. Radius Design: As indicated e. As indicated on the Drawing 4. Component Parts: a. Provide components and fittings required. ** NOTE TO SPECIFIER ** Series 500 mounted hand rail can be utilized as a standalone handrail structure for a stairway/ramp enclosed by a wall or other similar application. Handrail supplied in matching finish to existing rail if applicable. Delete if not required. Mounted handrail can be specified in conjunction with the following systems in order to meet code requirements: Series 9000/9100/9900 in a 42 inch high commercial guardrail application (guards must be 42 inches high but handrail must be between 34 inches and 38 inches high) Series 9000/9900 applications that do not utilize standard top rail and must meet ADA grip-ability requirements Series 9100 applications that must meet ADA grip-ability requirements Series 500/550 in a 42 inch high commercial guardrail application (guards must be 42 inches high but handrail must be between 34 inches and 38 inches high) Any other application where additional attached handrail is required. C. Series 500 Mounted Hand Rail: 1-1/2 inch (3.81 cm) Schedule 40 pipe with 1.9 inch (4.83 cm) outside diameter. Pipe shall be mounted to wall, railing, or other structure by utilizing mounting plates and run continuously throughout the whole length of handrail system. No components shall be fastened via welding. ** NOTE TO SPECIFIER ** Select base(s) required and delete those not required. A variety of base options are available to fit any installation requirements. Series 500/550 Railing can be base mounted with heavy-duty bases, side mounted with brackets, or embedded into concrete using an elongated post with a cover flange. D. Base: Size to fit the posts specified 1. Heavy-Duty Surface Mount Base 05720-9

2. Cover Flange for Embedded Posts 3. Side-Mount Corner Base 4. Side-Mount Base 5. As indicated on the Drawings. 2.3 RAILING MATERIALS A. Rail, Post and Pickets: Aluminum extrusions; alloy and temper 6063-T4 or 6063-T6 for rail, posts, and pickets. 1. Pipe: ASTM B 429. B. Base Flanges, Anchors, and railing accessories: ASTM B 247. 1. Bases cast from manufacturer s standard A-356-T6, 535, or 713 aluminum alloys or solid extruded 6063 aluminum alloy stock. 2. Base flanges and railing accessories cast from manufacturer s standard 319, A-356, A-356-T6, 535, or 713 aluminum alloys. 3. Anchorages: Provide concrete anchorage for fastening and complying with applicable Federal standards. All fasteners used in the system shall be aluminum or stainless steel. C. Fasteners: Provide concrete anchorage for fastening and complying with applicable Federal standards. All fasteners used in the system shall be aluminum or stainless steel. D. Grout: Non-shrink Portland cement-based hydraulic grout, mixed and applied in accordance with manufacturer's instructions; gypsum based material are not acceptable. Provide formulation that is resistant to erosion from water exposure without needing protection by a sealer or waterproof coating and recommended by manufacturer for exterior use. 2.4 FINISH 05720-10

** NOTE TO SPECIFIER ** Select finish required and delete those not required. Custom colors are available, contact the manufacturer for additional information. A. Baked on Enamel Colors (AAMA 2603): 1. White 2. Black 3. Light Bronze 4. Dark Bronze 5. Sandstone 6. Almond 7. Tan 8. Green 9. Custom colors as selected. B. Satin Anodized Finish: 1. 15 Minute: Architectural Clear Anodic Coating, AA-M12C22A21 2. 60 Minute: Architectural Class I, AA-M12C21A41 3. Brushed: Architectural Class I, AA-M12C22A41 C. Duranodic Architectural Hard Coat Anodized Finish, AA-M12C22A42 1. Dark Bronze 2. Black 3. Custom colors as selected. 2.5 FABRICATION 05720-11

A. All components or railing sections shall be fabricated at the manufacturing facility in largest practical site delivery sizes. All components or railing sections shall be fabricated to exact measurements specified through Drawings and field dimensions. 1. All pipe cuts shall be square and accurate for minimum joint-gap. Cuts shall be clean and free of chamfer, from deburring, nicks and burrs. B. If railing is angled horizontally, machine to proper angle into the post. C. Fabricate railing system to meet step railing requirements; riser and tread dimensions of the steps. D. All posts grouted in concrete to have one nominal 1/4 inch (6.0 mm) nominal diameter weep hole, 1/2 inch (12.0 mm) nominal above post collar, in the plane of the rail E. Provide components required for anchorage of framing. Fabricate anchors and related components of material and finish as required, or as specifically noted. PART 3 EXECUTION 3.1 EXAMINATION A. Do not begin installation until substrates have been properly prepared. B. If substrate preparation is the responsibility of another installer, notify Architect of unsatisfactory preparation before proceeding. 3.2 PREPARATION 05720-12

A. Clean surfaces thoroughly prior to installation. ** NOTE TO SPECIFIER ** Include the following paragraph and coordinate installation as applicable. Delete if not required. B. Coordinate railing installation with installation of waterproof membrane or coating Specified in Section 07xxx. C. Ensure that adjacent surfaces, structures, and finishes are protected from damage by construction activities of this section. D. Use wood blocks and padding to prevent damage to railing members and fittings during erection. E. Prepare surfaces using the methods recommended by the manufacturer for achieving the best result for the substrate under the project conditions. 3.3 INSTALLATION A. Install in accordance with manufacturer's instructions. B. Keep perimeter lines straight, plumb, and level. C. Provide grounds, clips, backing materials, adhesives, brackets, anchors, and accessories necessary for a complete installation. 1. Expansion Bolt Mounting: Anchor through base plates to concrete substrate. 2. Sleeve Mounting: a. Arrange for casting of sleeves or core drill insitu concrete to provide holes for railing uprights. b. After setting, fill holes with hydraulic grout; brace members until grout is cured. 05720-13

3. Connect railing components in accordance with manufacturer s instructions applicable to the specified system. Tighten all fasteners so that completed railing is rigid and free of play at joints and component attachments. 4. Expansion Joints: Provide expansion joints for continuous spans in excess of 40 feet (12.0 m). Construct joints by deleting structural adhesive from one end of the spliced joint so that it is free to move in or out of the pipe. If a joint is provided every 30 feet (9.0 m), the width of the gap should allow 1/8 inch (3.0 m) expansion for each 40 degrees F (22 degrees C) of expected temperature rise. 3.4 ERECTION TOLERANCES A. Install railings plumb and level, securely fastened, with vertical members plumb. 1. Maximum variation from plumb: 1/4 inch (6.0 mm). 2. Maximum misalignment from true position: 1/4 inch (6.0 mm). 3. Maximum misalignment between adjacent separated members: 1/8 inch (3.0 mm). 3.5 CLEANING A. Remove dust or other foreign matter from component surfaces; clean finishes in accordance with AAMA 609 and AAMA 610-02. 3.6 PROTECTION A. Protect installed products until completion of project. B. Touch-up, repair or replace damaged products before Substantial Completion. END OF SECTION 05720-14

05720-15