SECTION ACCESS PANELS

Similar documents
Access Doors. Complementary Building Products. Right to site.

B. Provide fire-rated access doors where indicated or scheduled.

A. Access doors and frames are part of an access door and frame allowance.

where high efficiency is the standard

Access Doors. Babcock-Davis Always right there.

Access Doors. Babcock-Davis Always right there.

Direct Service Done Right. Access Doors + Panels Catalog

WHERE HIGH EFFICIENCY IS THE STANDARD

Access Doors PRODUCT CATALOG

SECTION ACCORDION FOLDING PARTITIONS

COLLEGE CLASSROOM & DORMITORY SPECIFICATION SECTION 08100

Specifications PRE ASSEMBLED DOOR SPECIFICATION PART 1 GENERAL 1.01 SUMMARY

SECTION [ ] COILING COUNTER DOORS. Display hidden notes to specifier. (Don't know how? Click Here)

PASSAIC COUNTY TECHNICAL INSTITUTE CCA 1422 NEW S.T.E.M. BUILDING 2017

SECTION OVERHEAD COILING FIRE DOORS MODEL 662 OVERHEAD COILING COUNTER FIRE DOORS WITH INTEGRAL FRAME

SECTION PERSONNEL DUTY LOCKERS. 1. FPPL Series Police Personnel Duty Lockers, including the following:

Why Choose Karp Associates?

C S I S E C T I O N STAINLESS STEEL DOORS AND FRAMES SPECIFICATIONS

SECTION ROOF ACCESSORIES

SECTION RADIO FREQUENCY SHIELDING ENCLOSURE RF Welded System

ACCESS PANELS AND DOORS

B. Hollow Metal work for Interior frames, including Glazing Stops.

e. Cutouts and Holes for Toilet Accessories: Made to template and edge-reinforced.

B. Shop Drawings: For metal lockers. Include plans, elevations, sections, details, and attachments to other work.

COMPLETE REVISION November Process Industry Practices Architectural. PIP ARS08111 Standard Steel Doors and Frames Supplier Specification

AMBICO Limited Section and RFI\EMI SHEILDED STEEL DOOR AND FRAME ASSEMBLIES Page 1

MODERNFOLD GWS 100SR-G MOVEABLE GLASS WALLS

Aluminum-Framed Entrances and Storefronts

STEEL STUD, TRIMS AND ACCESSORIES FOR DRYWALL CONSTRUCTION MONTREAL TORONTO CALGARY EDMONTON VANCOUVER THE STRENGTH WITHIN

Access Doors AD-2014 Go to for the most current product specification sheets. LIT-043

UNIFIED FACILITIES GUIDE SPECIFICATIONS

SECTION SECTIONAL OVERHEAD DOORS

SECTION VIBRATION AND SEISMIC CONTROLS FOR ELECTRICAL SYSTEMS

B. Polyethylene samples shall be submitted for Owner approval of color and quality.

Northpointe Renovation EPN #1701 F/A Project #17027 September 8, 2017

SECTION LOUVERS AND VENTS

SECTION HVAC GRAVITY VENTILATORS

NORTHWESTERN UNIVERSITY PROJECT NAME JOB # ISSUED: 03/29/2017

B. Shop Drawings: Show fabrication and installation details for roof accessories.

Specifications for FL-100 Soffit Panel

COMPLETE REVISION June Process Industry Practices Architectural. PIP ARS08390 Blast Resistant Doors, Frames, and Related Hardware Specification

Central Dartmouth Section Exterior Envelope Renovations METAL-CLAD WOOD DOORS Page 1 of 5 Dartmouth, NS

1. Vertical reciprocating conveyor, Hydraulic straddle VRC.

.1 Underwriters' Laboratories of Canada (ULC)..1 CAN/ULC-S102-M88(R2000), Surface Burning Characteristics of Building Materials and Assemblies.

SECTION RESIDENTIAL OVERHEAD DOORS SIGNATURE COLLECTION WOOD GARAGE DOORS

B. Related Requirements: 1. [Section "Door Hardware"] for door hardware for hollow metal doors.

SECTION (Master Template Final-05) ELECTRICAL BOXES. A. Provide boxes for electrical equipment and wiring devices as follows:

PRESTON HEALTH SERVICES ARCHITECT'S NO. 2700

Features and benefits. Precision made using cnc machinery to ensure accurate and unobtrusive installation.

Student Services & Classroom Addition

SECTION TURBINE VENTILATORS

NORTH HARRIS COUNTY REGIONAL WATER AUTHORITY PIPE HANGERS, Section PIPE HANGERS, SUPPORTS, AND RESTRAINTS

SECTION IMPACT RESISTANT WALL PROTECTION

SIMEILINGS TORSION SPRING CEILING SYSTEM SPECIFICATION

SECTION SECTIONAL OVERHEAD DOORS 522 SERIES ALUMINUM SECTIONAL OVERHEAD DOORS. Display hidden notes to specifier. (Don't know how?

VELUX America Inc. SPECIFICATION FOR MODEL QPF SELF-FLASHED FIXED SKYLIGHT SECTION UNIT SKYLIGHTS

A. This Section includes automatic entrance door systems operating as follows: 1. Swinging operation.

Architectural Specifications, Section Phenolic Lockers

SOLAR SHADING SYSTEMS - Manual Solar Shade SECTION ROLLER WINDOW SHADES

A. Types of lightgauge metal framing units include the following: 1. C-shaped structural steel studs Uniform Building Code.

GUIDE SPECIFICATION EXETER SECURITY SHIELD SECURITY WINDOW BARRIER SYSTEM

Price Egg Crate Grille

Aluminum Flush Doors and Frames SPECIFICATIONS. Section [8120] PART 1 GENERAL

SECTION NON-STRUCTURAL METAL FRAMING

DOWNSPOUT Sc.ale: None

DIVISION 10 SPECIALTIES SECTION OPERABLE PARTITIONS

CUSTOMWOOD. taccess.com.au ACCESS PANELS (APC) Trafalgar has the most extensive range of access panels available:

Roof Accessories. Division Roof Hatches Roof Safety Rails Safety Posts. Division Smoke Vents

SECTION HANGERS AND SUPPORTS FOR PLUMBING

GUIDE SPECIFICATION EXETER VERSA SHIELD SECURITY SCREEN SYSTEM

B. LEED Submittals (Projects authorized for LEED certification only)

LINEAR METAL CEILINGS Section

SECTION SOLID COLOR REINFORCED COMPOSITE TOILET PARTITIONS

Series 3000 Pocket Doors

AND ACCESSORIES FOR DRYWALL CONSTRUCTION

Daytona Beach Pier Building Renovation Jun 2010

NORTHWESTERN UNIVERSITY PROJECT NAME JOB #

SECTION METAL FABRICATIONS

SECTION DIRECTORIES

Model 4010 Individual Panels / Curve & Diverter

FIRE RATED. taccess.com.au CEILING ACCESS PANELS (FRC) Trafalgar has the most extensive range of access panels available:

SECTION MODULAR GALVANIZED RF SHIELDING SYSTEM SPECIFICATIONS

PH6000. Key Features

The Contractor is responsible for quality control, including workmanship and materials furnished by his subcontractors and suppliers.

Riverbend Water Resources District Pump Station and Ground Storage Tanks Project Addendum No. 1 June 6, 2017

SECTION ACOUSTICAL PANEL CEILINGS

ALL-ALUMINUM DOOR & WINDOW FRAMING

SECTION CRL50 AND CRL51 HEAVY GLASS TOP HUNG SLIDING DOOR SYSTEMS

DIVISION 13 - SPECIAL CONSTRUCTION SECTION ACOUSTICAL PANEL ENCLOSURE

Box Rail. Single Box Rail Bracket

SECTION VINYL ACRYLIC CLAD WOOD DOORS PART 1 GENERAL 1.1 RELATED DOCUMENTS

Division 08 OPENINGS TABLE OF CONTENTS

BEARING METAL STUD FRAMING

HIR 1 ACOUSTICAL, IMPACT RESISTANT, TACKABLE WALL PANEL SPECIFICATION

SECTION PIPE AND TUBE RAILINGS PART 1- GENERAL 1.1 RELATED DOCUMENTS 1.2 SUMMARY 1.3 PERFORMANCE REQUIREMENTS

SECTION ROOF SPECIALTIES

SECTION ALUMINUM WINDOWS

SECTION U.S. ALUMINUM SERIES BAL-350 HURRICANE RESISTANT BALCONY/TERRACE DOOR

Alply CLASSIC WALL Architectural Insulated Panel Wall System

SECTION LIGHT DUTY SLIDING AND STACKING GLASS DOOR SYSTEMS

Transcription:

SECTION 08310 ACCESS PANELS PART 1: GENERAL 1.01 RELATED DOCUMENTS Drawings and general provisions of the contract, including supplementary conditions and Division 1 specification sections, apply to this section. 1.02 SUMMARY A. Section includes: access panels for the following types of installations: Wall access panels Ceiling access panels Fire Rated access panels for walls and ceilings 1.03 RELATED SECTIONS: Verify specification sections A. Section 07720 "Roof Accessories" for roof hatches and automatic smoke vents. B. Section 08000 "Door Hardware" for mortise cylinder lock. C. Section 08311 "Floor Hatches" for load bearing floor doors. D. Section 15000 "Duct Accessories" for duct access doors. 1.04 REFERENCES A. Insulated fire rated units for walls shall bear the Intertek/Wamock Hersev and/or Underwriters Laboratories. Inc. 1-1/2 hour "8" label with 250-temperature rise. B. Uninsulated fire rated units for walls only shall bear the Underwriters Laboratories. Inc. label for 1-1/2 hour "8" label with NO temperature rise. C. Fire rated units for ceilings shall bear the 1-hour combustible construction, 3-hour noncombustible construction label by lntertek/wamock Hersey. 1.05 SUBMIT~ALS A. General: In accordance with conditions of Division 1 specifications. 1. Shop drawings. 2. Manufacturer's literature and data. 1.06 QUALITY ASSURANCE A. Provide all access panels for the project by the same source and the same manufacturer. B. Fire Rated door assemblies that comply with NFPA 80 and are labeled by Underwriters Laboratories, Interek/Wamock Hersey or other testing facilities acceptable to authorities having jurisdiction. C. Obtain design professional's approval of sizes that may vary slightly from those indicated when they are not in accordance to manufacturer's standards. 1.07 COORDINATION The paragraphs below are optional but help to determine specific responsibility for access

panels. A. Determine specific locations and sizes for access panels needed to gain access to concealed equipment and indicate on schedule specified under "submittals" article. B. Access panels to gain access to equipment specified in Division 15 or 18 and where panels are not shown on drawings are to be provided by applicable subcontractor and in compliance with requirements listed in this section. 1.08 DELIVERY, STORAGE AND HANDLING A. Package and ship in accordance to manufacturer's recommendations. B. Store in compliance to manufacturer's instructions. AP-4 1. Store in dry area out of direct sunlight PART 2: PRODUCTS 2.01 MANUFACTURER A. Cierra Products Distributed by AmeraProducts Company P.O. Box 5665 Beaumont, Texas 77726-5665 1-800-608-6568 Phone: (409) 842-2267 Fax: (409) 842-5852 E-Mail: info@ameraproducts.com Internet www.ameraproducts.com 2.02 MATERIALS A. Commercial quality, cold steel sheet with baked on rust inhibitive gray primer. B. Galvanized bonderized steel a baked on rust inhibitive gay palmer. C. Type #304 stainless steel with #4 satin polish finish. 2.03 ACCESS PANELS A. Non rated flush access doors, Cierra C-N series 1. Door: Fabricate from 14-gauge cold ruled sheet steel. 2. Frame: Fabricate from 16-gauge cold rolled sheet steel. Provide ¼ mounting holes. C-NT - All surfaces 1 flange at perimeter. C-NW - Wallboard surfaces fl-gauge galvanized drywall bead at perimeter C-NP - Plaster surfaces - 22-gauge galvanized plaster 3. Hinge: Concealed type, spring loaded to allow for door removal, set to open 175 degrees.

a) Non-removable flush continuous tinge on sizes larger than 36 and on S stainless steel panels. 4. Latching/Locking devices: Screwdriver cam lath - standard. a) Key operated cylinder lock a two (2) bye per lock, keyed alike. b) Mortise cylinder preparation to receive 1 1/8 mortise cylinder lock. Cylinder lock provided by - as specified in Division 8 section Door Hardware c) Other options as specified. 5. Finish: Phosphate ipped a factory applied coat b) Type #304 Stainless steel with #4 satin polish. B. Insulated fire rated access panels for walls and ceilings, Cierra C-I series 1. Door: Fabricate from 20-gauge cold rolled sheet steel, Insulated sandwich type construction. 2. Frame: Fabricate from 16-gauge cold rolled steel of configuration to suit material application C-IT - Al surfaces 1 flange at perimeter. C-IW - Wallboard surfaces - 22-gauge galvanized drywall C-IP- Plaster surfaces - 22-gauge galvanized plaster bead at perimeter. 3. Hinge: Plush continuous piano type on model C-IT. Concealed pin hinge on style C-IW and C-IP. 4. Latching/Locking mechanism: Knurled knob/flush key operated latch bolt -standard. a) Mortise cylinder preparation to receive 1 1/8" mortise cylinder lock. Cylinder lock provided by as specified in Division 8 section "Door Hardware. b) Other options as specified. b) Type #304 stainless steel with #4 satin polish. 6. Insulation: 2" thick fire rated mineral fiber. 7. Automatic closure device: Integral automatic spring closure device for each door. 8. Interior latch release: Mechanism to allow for panel to open from interior side -standard on panels 18" and larger (safety feature). C. Uninsulated access panels for walls only, C-U cerles 1. Door: Fabricate from 14-gauge cold rolled sheet steel. 2. Frame: Fabricate from 16-gauge cold rolled sheet steel of C-UT- All surfaces - 1" flange at perimeter. C-UW - Wallboard surfaces 22-gauge galvanized drywall C-UP - Plaster surfaces 22-gauge galvanized plaster

b) Type #304 stainless steel. 3. Hinge: Flush continuous piano type. 4. Latching/Locking mechanism: Knurled knob/flush key operated latch bolt -standard. a) Mortise cylinder preparation to receive 1-1/8" mortise cylinder lock. Cylinder lock provided by - as specified In Division 8 section "Door Hardware. b) Other options as specified. b) Type #304 stainless steel with #4 satin polish. 6. Automatic closure device: Integral automatic spring closure device for each door 7. Interior release: Mechanism to allow for panel to open from interior side -standard on panels 18' and larger (safety feature). D. Recessed access panels, Cierra C-A series 1. Door: Fabricate from 16-gauge cold rolled sheet steel recessed 5/8" for in-fill of material. 2. Frame: Fabricate from 16-gauge cold rolled sheet steel of C-RW- Wallboard surfaces 22-gauge galvanized drywall C-RP - Plaster surfaces 22-gauge galvanized plaster C-RA - Acoustical surfaces - no surface frame. 3. Hinge: Concealed pivoting rod. a) Key operated cylinder lock with two (2) keys per lock, keyed alike. b) Mortise cylinder preparation to receive special 2" mortise cylinder lock. Cylinder lock provided by - as specified in Division 8 section "Door Hardware". c) other options as specified. 4. Finish: Phosphate dipped with factory applied prime coat. E. Security, Insulated fire rated access panels, Cierra C-S series (walls only) 1. Door: Fabricate from 14-gauge cold rolled sheet steel, insulated sandwich type construction. 2. Frame: Fabricate from 18-gauge cold rolled sheet steel of C-ST - All surfaces. 1' flange at perimeter. C-SW - Wallboard surfaces 22-gauge galvanized drywall C-SP - Plaster surfaces 22-gauge galvanized plaster b) Type #304 stainless steel.

3. Hinge: Concealed pin type for concealed frame. Flush continuous piano type for exposed frame and on panels larger than 36". 4. Latching/Locking mechanism: Mortise cylinder preparation to receive 1-1/8' mortise cylinder lock. Cylinder lock provided by- as specified in Division 8 section "Door Hardware'. a) Detention deadbolt lock preparation. Lock provided by- as specified in Division 8 section "Door Hardware". b) Other options as specified. b) Type #304 stainless steel with #4 satin finish. 6. Automatic closure device: Integral automatic spring closure device for each door. 7. Interior latch release: Mechanism to allow for panel to open from interior side on panels 18' and larger (safety feature). F. Medium security access doors, Cierra C-M series 1. Door: Fabricate from 12-gauge cold rolled sheet steel. 2. Frame: Fabricate from 12-gauge cold rolled sheet steel of C-UT - All surfaces -1' flange at perimeter. C-MW - Wallboard surfaces - 22-gauge galvanized drywall C-UP - Plaster surfaces 22-gauge galvanized plaster 3. Hinge: Concealed continuous piano type. 4. Latching/Locking mechanism: Pinned allen head security cam latches -standard. a) Mortise cylinder preparation to receive 1-1/8' mortise cylinder lock. Cylinder provided by - as specified in Division 8 section "door hardware'. b) Heavy-duty detention deadbolt lock preparation. Detention Lock provided as specified In Division 8 "Door Hardware'. c) Other options as specified. G. High security access panels, Cierra C-HS series 1. Door: Fabricate from 10-gauge cold rolled steel. 2. Frame: Fabricate from 2 x 2 x 3/16 steel angle, masonry anchors welded to frame. 3. Hinge: Heavy-duty steel butt hinge welded to the door and frame (surface mounted). a) Continuous piano type. 4. Latching/Locking mechanism: Pinned alien security screws standard. a) Mortise cylinder preparation to receive 1-1/8" mortise cylinder lock. Cylinder lock provided by- as specified in Division 8

section Door Hardware. b) Heavy-duty detention deadbolt lock preparation. Detention lock provided by - as specified in Division 8 section 'Door Hardware". c) Other options as specified. H. Maximum security access panels, Cierra C-TS series 1. Door: Fabricate from 7-gauge hot rolled steel. 2. Frame: Fabricate from 2 x 3 x 3/16" steel angle, masonry anchors welded to frame. 3. Hinge: Heavy-duty steel butt hinge welded to the door and frame (surface mounted). a) Continuous piano type. 4. Latching/Locking mechanism: Heavy-duty detention lock preparation standard. Detention lock provided by-as specified in Division 8 section Door Hardware. a) Other options as specified. I. Exterior Insulated access panel, Cierra C-XT series 1. Door: Fabricate from 20-gauge galvanized steel, insulated sandwich type construction. a) Type #304 stainless steel. 2. Frame: Fabricate from 6063-T5 extruded aluminum. 3. Hinge: Zinc plated continuous type. a) Stainless steel continuous piano type. 4. Latching/Locking device: Two dual acting handles. a) Lockable handle for exterior only. 5. Flange:.080 6063-T5 extruded aluminum. 6. Finish: Paint grip. 7. Insulation: 2' thick fiberglass. 6. Gasket: Extruded santoprene. J. Special lightweight access panel, Cierra C-LW series 1. Door: Fabricate from 26-gauge pre-finished embossed galvanized steel. a).063 aluminum door panel 2. Frame:.045 6063 T5 extruded aluminum with rolled 1-5/16' flange 3. Hinge: Zinc plated continuous piano type. a) Aluminum continuous piano type. 4. Latching/Locking device: Screwdriver cam latch standard. a) Key operated cylinder lock with two (2) keys per lock, keyed alike. 5. Insulation: %' polystyrene with 3.8 R-value at 75 degrees F

2.04 PADRICATION temperature. 6. Finish: White embossed steel. a) Mill finish with.063 aluminum panel insert. A. Manufacture each access panel assembly as an integral unit ready for Installation. B. Welded construction: Furnish with a sufficient quantity of 1I4~ mounting holes to secure access panels to types of supports indicated. C. Recessed panel: Form face of panel to provide specified recess for application of finish material. Reinforce panel as required to prevent buckling. D. Furnish number of latches required to hold door in flush smooth pane when closed. PART 3: EXECUTION 3.01 EXAMINATION A. Verify conditions are ideal for suitable installation. 3.02 PREPARATION A. Advise installers of work relating to access panel installation including rough opening dimensions, locations of supports, and anchoring methods. Coordinate delivery with other work to avoid delay. 3.03 INSTALLATION A. Follow manufacture's Instructions for installing access panels. B. Set frames to proper alignment with the wall or ceiling. C. Position access panels for proper access to concealed equipment requiring access. 3.04 ADJUST AND CLEAN A. Adjust panel after Installation for proper operation. B. Remove and replace panels or frames that are warped, bowed, or damaged.