BEHAVIOR OF MOMENT RESISTING REINFORCED CONCRETE CONCENTRIC BRACED FRAMES (RC-MRCBFs) IN SEISMIC ZONES

Similar documents
Review of the Soft First Story Irregularity Condition of Buildings for Seismic Design

SEISMIC VULNERABILITY ASSESSMENT OF STEEL PIPE SUPPORT STRUCTURES

22. DESIGN OF STEEL BRACED FRAMES Eccentrically Braced Steel Frames

Title. Author(s)ARDESHIR DEYLAMI; MOSTAFA FEGHHI. Issue Date Doc URL. Type. Note. File Information IRREGULARITY IN HEIGHT

HYBRID MOMENT RESISTING STEEL FRAMES

Steel Rigid Frame Structural Behaviour at El Mayor Cucapah (Baja California) Earthquake April 4, 2010.

Seismic Evaluation of Steel Moment Resisting Frame Buildings with Different Hysteresis and Stiffness Models

Evaluation of Seismic Behavior for Low-Rise RC Moment Resisting Frame with Masonry Infill Walls

Seismic Assessment of an RC Building Using Pushover Analysis

Effect of Concentric Braces on the Behaviour of Steel Structure by Pushover Analysis

Static Analysis of Multistoreyed RC Buildings By Using Pushover Methodology

Department of Civil Engineering, College of Civil Engineering, Semnan branch, Islamic Azad University, Semnan, Iran.

ECCENTRICALLY BRACED FRAME DESIGN FOR MODERATE SEISMIC REGIONS

REHABILITATION OF RC BUILDINGS USING STRUCTURAL WALLS

PEER Tall Building Seismic Design Guidelines

Survey and Testing of Pre-1988 Braced Frame Structures From The West Coast of the United States

ctbuh.org/papers CTBUH Recommendations for the Seismic Design of High-Rise Buildings

Comparative Study on Concentric Steel Braced Frame Structure due to Effect of Aspect Ratio using Pushover Analysis

EVALUATION OF NONLINEAR STATIC PROCEDURES FOR SEISMIC DESIGN OF BUILDINGS

Seismic Performance and Design of Linked Column Frame System (LCF)

DESIGN ASPECTS AFFECTING THE SEISMIC BEHAVIOUR OF STEEL MRF BUILDINGS: ANALYSIS OF THREE CASE STUDIES

Application of Pushover Analysis for Evaluating Seismic Performance of RC Building

Simi Aboobacker 1 and Nisha Varghese 2

OPTIMUM POSITION OF OUTRIGGER SYSTEM FOR HIGH RAISED RC BUILDINGS USING ETABS (PUSH OVER ANALYSIS)

Efficiency of bracing systems for seismic rehabilitation of steel structures

Pushover Analysis of High Rise Reinforced Concrete Building with and without Infill walls

NON LINEAR BEHAVIOR OF STEEL FRAMES AND SPECTRUM REDUCTION FACTOR

Modern Seismic Design Approach for Buildings with Hysteretic Dampers

Comparison of Chilean and US Seismic Design Provisions for Timber Structures

An Investigation of Seismic Response Reduction Factor for Earthquake Resistant Design

NON-LINEAR STATIC PUSHOVER ANALYSIS FOR MULTI-STORED BUILDING BY USING ETABS

Seismic performance assessment of reinforced concrete buildings using pushover analysis

Stability Analysis of Rigid Steel Frames With and Without Bracing Systems under the Effect of Seismic and Wind Loads

COMPARATIVE STUDY ON SEISMIC BEHAVIOR OF SPECIAL CONCENTRIC BRACED FRAMES WITH ECCENTRIC BRACED FRAMES

PERFORMANCE- BASED SEISMIC DESIGN OF A BUILDING

Energy dissipation demand of compression members in concentrically braced frames

A COMPARISON BETWEEN THE REQUIREMENTS OF PRESENT AND FORMER ROMANIAN SEISMIC DESIGN CODES, BASED ON THE REQUIRED STRUCTURAL OVERSTRENGTH

Nonlinear Pushover Analysis of Steel Frame Structure Dahal, Purna P., Graduate Student Southern Illinois University, Carbondale

Volume 1. HOW TO MAKE A DREAM HOUSE EARTHQUAKE RESISTANT Contents

Performance Based Seismic Design of Reinforced Concrete Building

PERFORMANCE STUDY OF RETROFITTED GRAVITY LOAD DESIGNED WALL FRAME STRUCTURES (SC-140)

STRENGTH REDUCTION FACTORS FOR MULTI-DEGREE-OF-FREEDOM SYSTEMS

Seismic behavior factors of buckling-restrained braced frames

REINFORCED CONCRETE WALL BOUNDARY ELEMENT LONGITUDINAL REINFORCING TERMINATION

PUSHOVER ANALYSIS FOR THE RC STRUCTURES WITH DIFFERENT ECCENTRICITY

Overview of Presentation. SCBFs are Conceptually Truss Structures

COMPARISON OF PERFOMANCE OF THIN STEEL SHEAR WALLS AND CONCENTRIC BRACES BY CAPACITY SPECTRUM METHOD

Analysis of Various Steel Bracing Systems using Steel Sections for High Rise Structures

PERFORMANCE OF ECCENTRICALLY BRACED FRAMES UNDER THE ACTION OF LATERAL LOAD

EVALUATION OF THE NEED FOR WEAK BEAM-STRONG COLUMN DESIGN IN DUAL FRAME-WALL STRUCTURES

NONLINEAR DYNAMIC RESPONSE OF DISSIPATIVE DEVICES FOR SEISMIC RESISTANT STEEL FRAMES: EXPERIMENTAL BEHAVIOUR AND NUMERICAL SIMULATION

Cold-Formed Steel Special Bolted Moment Frames: Capacity Design Requirements

Seismic Performance Evaluation of Eccentrically Braced Frame Using PBPD Method

NONLINEAR PERFORMANCE OF A TEN-STORY REINFORCED CONCRETE SPECIAL MOMENT RESISTING FRAME (SMRF)

by Dr. Mark A. Ketchum, OPAC Consulting Engineers for the EERI 100 th Anniversary Earthquake Conference, April 17, 2006

INTERNATIONAL JOURNAL OF PURE AND APPLIED RESEARCH IN ENGINEERING AND TECHNOLOGY

Span Length Effect on Seismic Demand on Column Splices in Steel Moment Resisting Frames

Evaluation of Seismic Behavior of Buckling Restrained Braced Frames as Dual System in Combination with Special Moment Resisting Frames

IJSRD - International Journal for Scientific Research & Development Vol. 2, Issue 09, 2014 ISSN (online):

Seismic performance of ductile shear wall frame systems

COST C26. Urban Habitat Constructions under Catastrophic Events EARTHQUAKE RESISTANCE WG 2 Session, March 30th

3. CLASSIFICATION AND IMPLICATIONS OF DAMAGE

Advance Design Bracing members design according to Eurocode 3

U.S. General Services Administration Progressive Collapse Design Guidelines Applied to Concrete Moment-Resisting Frame Buildings

Gravity Load Collapse of Reinforced Concrete Columns with Brittle Failure Modes

Analysis of Reinforced Concrete Building with Different Arrangement of Concrete and Steel Bracing system

Seismic design of braced frame gusset plate connections

ANALYTICAL STUDIES OF A FULL-SCALE STEEL BUILDING SHAKEN TO COLLAPSE

Study of Inelastic Behavior of Eccentrically Braced Frames under Non Linear Range

INTERACTION OF TORSION AND P-DELTA EFFECTS IN TALL BUILDINGS

INNOVATIVE DESIGN AND TESTING OF A SEISMIC RETROFITTED STEEL DECK TRUSS BRIDGE

PUSHOVER ANALYSIS OF A 19 STORY CONCRETE SHEAR WALL BUILDING

IJSRD - International Journal for Scientific Research & Development Vol. 2, Issue 07, 2014 ISSN (online):

SEISMIC ANALYSIS OF SIX STOREYED RC FRAMED BUILDING WITH BRACING SYSTEMS

ON DRIFT LIMITS ASSOCIATED WITH DIFFERENT DAMAGE LEVELS. Ahmed GHOBARAH 1 ABSTRACT

Seismic design of large underground structures Application of a new methodology to structures with feasible layout

Evaluation of Earthquake Risk Buildings with Masonry Infill Panels

Keywords ETABS 2013, Earthquake, Waffle Slab, Flat Slab, Seismic Analysis, Storey Drift, Maximum Displacement. 1.1 Objective

Inelastic Versus Elastic Displacement-Based Intensity Measures for Seismic Analysis

DEVELOPMENT OF FLOOR DESIGN SPECTRA FOR OPERATIONAL AND FUNCTIONAL COMPONENTS OF CONCRETE BUILDINGS IN CANADA

TO STUDY THE PERFORMANCE OF HIGH-RISE BUILDING UNDER LATERAL LOAD WITH BARE FRAME AND SHEAR WALL WITH OPENINGS

Structural Systems with Enhanced Seismic Resiliency Using High-Performance Materials

International Journal of Engineering Research And Management (IJERM) ISSN: , Volume-03, Issue-11, November 2016

This point intends to acquaint the reader with some of the basic concepts of the earthquake engineer:

NON-LINEAR STRUCTURAL INTEGRITY ANALYSIS

REINFORCED CONCRETE STRUCTURAL WALLS AS SOLUTION TO RETROFIT A R/C FRAME. Patricio Bonelli 1, Rubén Boroschek 2.

Council on Tall Buildings

PERFORMANCE-BASED SEISMIC DESIGN OF BRACED-FRAME GUSSET PLATE CONNECTIONS

SEISMIC EFFECTS ON COUPLED SHEAR WALL STRUCTURE BY COUPLING BEAMS WITH SIDE BOLTED STEEL PLATES

Available at ISSN

Modelling of RC moment resisting frames with precast-prestressed flooring system

VULNERABILITY EVALUATION OF COMMON SIMPLE-SUPPORTED BRIDGES

EFFECTS OF COLUMN SPLICE LOCATION ON SEISMIC DEMANDS IN STEEL MOMEMNT FRAMES CONSIDERING SPLICE FLEXIBILITY

DESIGN OF HIGH-RISE CORE-WALL BUILDINGS: A CANADIAN PERSPECTIVE

Analytical Study on Seismic Performance of Hybrid (DUAL) Structural System Subjected To Earthquake

Application of Buckling Restrained Braces in a 50-Storey Building

EFFECT OF LINK ON ECCENTRICALLY BRACED FRAMES

SEISMIC EVALUATION OF BUILDINGS WITH POSTTENSIONED BEAMS BY NON-LINEAR STATIC ANALYSIS

Yousef Zandi Member of Academic Staff, Department of Civil Engineering, Tabriz Branch, Islamic Azad University, Tabriz, Iran.

A Two-Ring Energy Dissipating Device with Similar Behaviors in Tension and Compression to Create Buckling Resistant Braces

Transcription:

BEHAVIOR OF MOMENT RESISTING REINFORCED CONCRETE CONCENTRIC BRACED FRAMES (RC-MRCBFs) IN SEISMIC ZONES E.A. Godínez-Domínguez 1 and A. Tena-Colunga 2 1 PhD Student, Departamento de Materiales, Universidad Autónoma Metropolitana, México, DF. Mexico 2 Professor, Departamento de Materiales, Universidad Autónoma Metropolitana, México, DF. Mexico Email: eagd@correo.azc.uam.mx, atc@correo.azc.uam.mx ABSTRACT This paper presents the results of a study devoted to evaluate, using nonlinear analyses, the behavior of ductile moment-resisting reinforced concrete concentric braced frames structures (RC-MRCBFs) using steel bracing. RC-MRCBFs were designed for lakebed region of Mexico City. It is possible to conclude from the results obtained in this study the need to improve current guidelines in the Mexican building code in order to warrant a ductile behavior for this structural system and to achieve the expected collapse mechanism. KEYWORDS: Reinforced concrete structures, concentric braced frames, dual systems, seismic design, capacity design 1. INTRODUCTION Due to the good behavior observed in the retrofitted RC structures by the addition of steel bracing in Mexico City, it is attractive to consider using this system for original design as well. In fact, the seismic guidelines of Mexico s Federal District Code (MFDC-04) allow for more than 30 years the design of a moment-resisting reinforced concrete concentric braced frames structures (RC-MRCBFs), considering even the possibility of a ductile behavior. However, in the design practice, this system has almost never been used for new construction. Currently, there are shortcomings in MFDC-04 and other international codes to design ductile RC-MRCBFs. Most building codes extrapolate recommendations developed for ductile moment-resisting frames to design ductile MRCBFs, which seems to be an incomplete strategy. The absence of enough specific guidelines in building codes to insure a ductile behavior of MRCBFs using conceptual capacity design principles is notorious. Therefore, the expected failure mechanism of strong column weak beam weaker brace is not warrant following general guidelines available in international building codes. According to the guidelines of Mexico s Federal District Code (MFDC-04), moment-resisting reinforced concrete concentric braced frames structures (RC-MRCBFs) should be analyzed considering the shear contribution of two structural systems as shown in Figure 1: the RC frame and the steel bracing system. Moment frames at all the stories must resist, without the bracing system contribution, at least 50% of the seismic force. RC-MRCBFs RC Frame Steel bracing system Figure 1. Assumption on how seismic shear forces must be resisted in RC-MRCBFs according with MFDC-04

2. SUBJECT BUILDINGS Twenty-seven regular reinforced concrete moment-resisting concentric braced frames (RC-MRCBFs) using steel bracing were designed according to the seismic, concrete and steel guidelines of Mexico s Federal District Code (MFDC-04) for lake-bed region (zone III b ) and a seismic response modification factor Q=4, the maximum allowed for these structures. The corresponding elastic and inelastic design spectra are shown in Figure 2. Figure 2. Design spectra for zone III b according to the MFDC-04 Building models ranged from 4 to 16 stories, using two different bracing layout configurations (Fig. 3). The typical floor plan considered in the study is depicted in Figure 3. RC-MRCBFs were designed using different shear strength ratios between the bracing system and the moment frame system (Figure 1). Y 1 2 3 4 5 8 m 8 m 8 m 8 m A 7 m B 7 m C 7 m D = Bracing Y a) Floor plan for the building b) Frame layout in Y direction c) Frame layout in direction Figure 3. Floor plan of the building and elevation view of the studied frames 3. CASES OF STUDY Three different cases were studied for each considered building height, based on the lateral shear strength percentage resisted by the columns of the RC-MRCBFs. The cases studied were: (a) The percentage of the lateral shear strength provided for the steel bracing system is greater than the percentage provided for the columns of the RC moment-resisting frame. Near to twenty-five percent of the lateral shear strength is provided by the columns of the RC moment-resisting frame (condition no allowed in MFDC-04). (b) Fifty percent of the lateral shear strength is provided by the columns of the RC moment-resisting frame (minimum shear strength percentage allowed in MDFC-04). (c) Near to seventy-five percent of the lateral shear strength is provided for the columns of the RC moment-resisting frame (allowed condition in MDFC-04). The considered strength balances just mentioned above were selected as they would allow a better understanding

on the behavior of this structural system based on the shear strength distribution between the two different components of this dual system (Fig. 1) and the building height. Besides, it is important to review the minimum shear strength required for the columns of RC-MRCBFs, as the proposed value in MDFC-04 is based more in the experience and common sense of code committee members rather than in specific studies devoted to define an adequate target value. 4. DESIGN METHODOLOGY Currently, there are shortcomings in most international codes to design RC-MRCBFs. Most RC building codes extrapolate recommendations developed for moment-resisting frames to design MRCBFs, which is an incomplete strategy. The absence of specific guidelines in building codes to warrant a ductile behavior in MRCBFs using conceptual capacity design principles is notorious. The expected failure mechanism of strong column weak beam weaker brace is not warrant following general guidelines available in many building codes. Therefore, a conceptual capacity design methodology has been explored in this research study for the design of MRCBFs. The methodology, which is described in detail elsewhere (Godínez-Dominguez and Tena-Colunga 2007) explicitly takes into account the sequence for designing resisting elements in order to warrant the expected collapse mechanism: (1) bracing elements, (2) beams, (3) columns, (4) connections between the frame and the bracing system and, (5) panel zone (joint area). The axial force transmitted from the bracing system to connections, columns, as well as to the beams subjected to such forces because of the bracing configuration is addressed in the design procedure, something that it is not currently addressed properly in RC building codes. 5. NONLINEAR STATIC ANALYSES Nonlinear static analysis (pushover analyses) of representative perimeter frames models (Figure 3) for the designed 4 to 16 story buildings were carried out using Drain-2D program (Prakash et al. 1992). P- effects were considered in all analyses. In order to identify the different models, a cryptogram was defined: FNdpp, where F indicates a chevron bracing frame, N indicates the number of stories of the frame, d indicates the analysis direction (x or y) according to the floor plan (Figure 3) and finally, pp indicates the shear force percentage provided by the RC columns. The designed member sections for each RC-MRCBFs vary along the height of the frame, following a common design practice done by structural engineers in Mexico. Beams and columns change their cross section every four stories. Also, the box sections for the steel bracing change every three stories, in this case, the bracing system changes only its thickness remaining constant the width of the section. Story and global lateral shear vs drift curves were obtained for all the described models. The curves obtained for the eight-story and sixteen-story models are shown in Figure 4 and Figure 5 respectively. These curves give insight on the medium-rise height building category that it is common in Mexico City. In these curves the lateral strength provided by the concrete columns and the steel braces elements is shown by separate, as well as the sum of the strength of these two components, which yields the total lateral strength for the RC-MRCBFs. It is observed from Figures 4 and 5 that columns and braces behave differently as they enter into the inelastic range of response. After first yielding, steel braces keep on increasing their lateral strength (positive slope), whereas the columns, in the majority of the models, often decrease their lateral strength after yielding (negative slope). This effect can also be observed in Table 1, which the strength variation in braces and columns across the analysis are also reported. The mentioned phenomenon becomes less evident as the height of the models increase, as well as the lateral shear strength provided by the reinforced concrete columns of the frame increases. This phenomenon is observed both in the story curves and in the global response curves. It can be observed from Figures 4 and 5 that for models where columns resist near 25% of the total seismic shear

force (F8x25 and F16x25) that a reduced inelastic behavior is demanded in the upper stories, remaining elastic. On the other hand, for the models where columns resist near 75% of the total seismic shear force (F8x75 and F16x75), a better distribution of the inelastic behavior along the height is observed, which is desirable in order to obtain a more uniform distribution of the energy dissipation and, in fact, dissipate more energy. Model F8x25 Model F8x50 Model F8x75 Figure 4. Story and global lateral shear-drift curves for the eight-story models Table 1. Shear strength contribution for columns and braces to resist lateral seismic loads at different time-steps Elastic response First yielding First plastic hinge Collapse mechanism Model %Columns %Braces %Columns %Braces %Columns %Braces %Columns %Braces F4x25 34.13 65.87 31.71 68.29 33.32 66.68 32.26 67.74 F4x50 64.05 35.95 65.78 34.22 64.15 35.85 58.32 41.68 F4x75 79.19 20.81 80.43 19.57 75.42 24.58 64.12 35.88 F8x25 44.45 55.55 39.02 60.98 32.41 67.59 28.72 71.28 F8x50 59.84 40.16 55.34 44.66 47.98 52.02 41.64 58.36 F8x75 77.63 22.37 73.42 26.58 67.57 32.43 55.50 44.5 F12x25 44.66 55.34 40.85 59.15 27.62 72.38 23.54 76.46 F12x50 66.55 33.45 65.04 34.96 53.02 46.98 44.70 55.3 F12x75 71.98 28.02 69.28 30.72 63.19 36.81 45.63 54.37 F16x25 50.14 49.86 45.34 54.66 40.38 59.62 33.03 66.97 F16x50 63.94 36.06 63.47 36.53 56.76 43.24 44.29 55.71 F16x75 76.39 23.61 75.44 24.56 63.61 36.69 50.35 49.65 The largest story drifts observed in the lateral shear-drift curves correspond to intermediate levels, exactly at the stories where a change of section exist. As presented in following sections, the resisting elements at those levels experienced the highest plastic hinge rotations.

Model F16x25 Model F16x50 Model F16x75 Figure 5. Story and global lateral shear-drift curves for the sixteen-story models

5.1. Yielding mapping The final collapse mechanisms are presented for the models in the x direction only. The magnitude of inelastic deformations in beams and columns are shown by a color scale using circles, whereas the axial extension in braces (braces in tension at the left side of the braced bays) and the axial shortening in braces (braces in compression at the right side of the braced bays) are shown by a second color scale using oval marks. Yielding mappings shown in Figures 6 to 8 correspond to the time-step where the collapse mechanism was formed. The maximum inelastic deformations were controlled taking into account the assessment of the theoretical plastic rotation capacities for beams and columns and axial extensions and buckling shortenings for the steel braces. For the braces, the magnitude of the buckling length (L p ), which defines the failure of the element, was computed according with the methodology proposed by Kemp (1996), which is based in a comprehensive compilation of experimental research. The yielding mapping for the final collapse mechanism for the four, eight, twelve and sixteen-story models where columns resist near 25% of the total seismic shear force are depicted in Figure 6; models where columns resist near 50% of the total seismic shear force are depicted in Figure 7; and finally, models where columns resist near 75% of the total seismic shear force are depicted in Figure 8. The study of models where columns resist near of 25% of the total seismic shear force (not allowed in MFDC-04 for a ductile RC-MRCBFs, Figure 6) was done to explore smaller values to the minimum shear strength required in the columns of RC-MRCBFs in MDFC-04, as this recommendation is based more in experience and common sense than in specific studies focused to assess a minimum reasonable balance of the shear strength provided by each component of the RC-MRCBFs (Figure 1) that would lead to a ductile behavior. It was found that this strength balance lead to the use of stocky braces. As a consequence, the expected failure mechanism of strong column weak beam weaker brace is not warrant. In fact, the first plastic hinge rotation usually develops in a column. Also, due to the axial force transmitted by the braces to the columns, plastic hinge rotations can be formed at both columns ends in the same story (Figure. 6), which it is not desirable as it can lead to the formation of soft-story mechanisms. For the models where columns resist near 50% (minimum shear strength contribution currently required for columns of ductile RC-MRCBFs by MFDC-04) and 75% of the total seismic shear force (Figures 7 and 8, respectively), the distribution and magnitudes of plastic hinge rotations are similar. The first plastic deformation always occurs in a brace element. Collapse mechanisms for low-rise and medium-rise models (four to twelve stories) adjust reasonably with the expected failure mechanism of strong column weak beam weaker brace. It is important to consider that plastic hinge rotations in columns at their base are due to the fixed-base modeling assumption. Nevertheless, as the models start to become taller (sixteen-story models, Figures. 7d and 8d), some incipient plastic rotations are formed at the column ends in the lower levels, which according with the direction of the applied loads, they are located in the tension side. These plastic rotations are developed because the magnitude of the axial force in the exterior columns of the 16-story models is higher than those developed in the other low-rise and medium-rise models. For building sixteen stories in height or taller, it is likely that the design methodology used must be adjusted to prevent the formation of plastic hinges at column ends at the lower stories, or to further limit the shear strength contribution for the columns to resist lateral seismic loads. The effect of the height in the structural behavior of MRCBFs has been explored. Most of the referred studies have focused in steel structures (i.e. Bruneau et al. 1998, Tapia-Hernández and Tena-Colunga 2008), and they have shown that rather different collapse mechanism could be developed for CBFs for medium-rise buildings. Based upon the results discussed above, it is found that the guideline available in MFDC-04 that does not allow the design of RC-MRCBFs where columns resist less than 50% of the total seismic shear force seems reasonable enough.

a) F4x25 b) F8x25 c) F12x25 d) F16x25 Figure 6. Collapse mechanisms for models where columns resist near 25% of the total seismic shear force a) F4x50 b) F8x50 c) F12x50 d) F16x50 Figure 7. Collapse mechanisms for models where columns resist near 50% of the total seismic shear force a) F4x75 b) F8x75 c) F12x75 d) F16x75 Figure 8. Collapse mechanisms for models where columns resist near 50% of the total seismic shear force 0.00-0.0030 0.0030-0.0060 0.0060-0.0090 0.0090-0.012 0.012-0.015 0.015 Tension Compression 5.2. Overstrength factors (R) L < Lp L Lp L < Lp L Lp Overstrength factors (R) are shown in Figure 9, which were assessed from the global pushover curves. Figure 9a and 9b shows the V nom /V design and V sr /V design relations, respectively. Also, the overstrength factor value proposed

in the seismic provisions (MFDC-04) is depicted. It is clear that structures with low natural periods (four-story buildings) have greater overstrength levels than those proposed in MDFC-04. Generally, differences are observed between the assessed values and the proposed values. A relationship between the assessed R factors and the shear strength contribution for the columns to resist lateral seismic loads can be observed. a) R (taking into account nominal strength) b) R (taking into account overstrength sources) Figure 9. Assessed overstrength factors (R) 6. CONCLUDING REMARKS Currently, there are shortcomings in many international codes to design ductile RC-MRCBFs. Many building codes extrapolate recommendations developed for RC moment-resisting frames to design MRCBFs, which is an incomplete strategy. From the results obtained in this study, it seems that the capacity design methodology used by the authors is successful to design ductile RC-MRCBFs when the columns of the moment frames resist at least 50% of the total seismic shear force, supporting with numerical evidence this proposed strength balance established in MFDC-04. However, the optimal strength balance between the RC frame and the steel bracing system seems to vary depending on the building height, so the authors are currently studying this possibility designing buildings with 20 and 24 stories. It was found a notorious difference between the assessed overstrength factors (R) and the proposed values in MFDC-04. A relationship seem to exist between the assessed R factors and the shear strength contribution for the columns to resist lateral loads, so a new expression could be developed to define the R factor for RC-MRCBFs in Mexican codes in order to improve their design. REFERENCES Bruneau, M., Uang, C., and Whittaker, A. (1998). Ductile design of steel structures, second edition, McGraw-Hill, New York. Godínez-Domínguez, E.A. and Tena-Colunga, A. (2007). Evaluación de los criterios de diseño sísmico del RCDF para marcos dúctiles de concreto reforzado con contravientos. Proceedings, VI Congreso Nacional de Ingeniería Sísmica, Ixtapa, Mexico, CD-ROM, November (in Spanish). Kemp, R.A. (1996). Inelastic local and lateral buckling in design codes. Journal of Structural Engineering ASCE, 22:4, 374-382. MFDC-04, (2004). Reglamento de Construcciones para el Distrito Federal. Gaceta Oficial del Departamento del Distrito Federal (in Spanish). Prakash, V., Powell, G.H., and Fillipou, F, (1992). DRAIN-2D: base program user guide, Report No. UBC/SEMM-92/29, Department of Civil Engineering, University of California at Berkeley. Tapia-Hernández, E. and Tena-Colunga, A. (2008). Behavior of moment resisting concentrically braced frames (MRCBFs) of regular buildings in seismic zones. Proceedings, 14 th World Conference on Earthquake Engineering, Beijing, China, October.