EARTHQUAKE SIMULATIONS ON A SELF-CENTERING STEEL MOMENT RESISTING FRAME WITH WEB FRICTION DEVICES

Similar documents
DESIGN OF SELF-CENTERING MOMENT RESISTING FRAME AND EXPERIMENTAL LOADING SYSTEM

Real-time Hybrid Simulation: Validation of PBD Procedure for Steel Frames with Nonlinear Viscous Dampers

Seismic Resilient Systems: Concepts and Challenges

Chinmoy Kolay Research Engineer

DESIGN AND BEHAVIOR OF POST-TENSIONED STEEL MOMENT FRAMES

LATERAL LOAD BEHAVIOR OF UNBONDED POST-TENSIONED HYBRID COUPLED WALLS. Qiang SHEN Graduate Research Assistant. Yahya C. KURAMA Assistant Professor

Seismic Performance and Design of Linked Column Frame System (LCF)

HYBRID MOMENT RESISTING STEEL FRAMES

Seismic performance analysis of self-centering steel frames with intermediate columns containing friction dampers

REINFORCED CONCRETE WALL BOUNDARY ELEMENT LONGITUDINAL REINFORCING TERMINATION

Seismic evaluation of Hybrid steel frames with different patterns of semi-rigid connection

Analytical and Large-Scale Experimental Studies of Earthquake-Resistant Buckling-Restrained Braced Frame Systems

SEISMIC VULNERABILITY ASSESSMENT OF STEEL PIPE SUPPORT STRUCTURES

Seismic Evaluation of Steel Moment Resisting Frame Buildings with Different Hysteresis and Stiffness Models

PEER Tall Building Seismic Design Guidelines

CYCLIC TESTING OF BOLTED CONTINUOUS I-BEAM-TO-HOLLOW SECTION COLUMN CONNECTIONS

EVALUATION OF NONLINEAR STATIC PROCEDURES FOR SEISMIC DESIGN OF BUILDINGS

Evaluation of the ASCE 7-05 Standard for Dual Systems: Response History Analysis of a Tall Buckling-Restrained Braced Frame Dual System

Evaluation of Seismic Behavior of Buckling Restrained Braced Frames as Dual System in Combination with Special Moment Resisting Frames

Nonlinear Pushover Analysis of Steel Frame Structure Dahal, Purna P., Graduate Student Southern Illinois University, Carbondale

PEER/CSSC Tall Building Design Case Study Building #1. J. Andrew Fry John Hooper Ron Klemencic Magnusson Klemencic Associates

Span Length Effect on Seismic Demand on Column Splices in Steel Moment Resisting Frames

Advanced Technology for Large Structural Systems Research Center Lehigh University Bethlehem, PA

Overview of Presentation. SCBFs are Conceptually Truss Structures

Design, Construction, and Characterization of a Large Scale Steel Structural System for Real Time Hybrid Testing

Below-Grade Structurla Flexibility Study for Seismic-Resistant, Self-Centering, Concentrically- Braced Frames

A Comparison of Seismic Performance and Vulnerability of Buckling Restrained and Conventional Steel Braced Frames

Performance Based Seismic Design of Reinforced Concrete Building

SEISMIC EVALUATION AND PERFORMANCE ENHANCEMENT OF INDUSTRIAL STORAGE RACKS YUAN GAO. Submitted in partial fulfillment of the requirements

Index terms Diagrid, Nonlinear Static Analysis, SAP 2000.

Retrofit of an Existing Hospital to Immediate Occupancy Standards. One Year Later. Degenkolb Engineers

Seismic performance assessment of reinforced concrete buildings using pushover analysis

SEISMIC PERFORMANCE OF CONCRETE TILT-UP BUILDINGS: CURRENT WALL-TO-SLAB CONNECTIONS

3.5 Tier 1 Analysis Overview Seismic Shear Forces

NON-LINEAR STATIC PUSHOVER ANALYSIS FOR MULTI-STORED BUILDING BY USING ETABS

Simi Aboobacker 1 and Nisha Varghese 2

Performance of Steel Moment Connections under a Column Removal Scenario. I: Experiments

Application of Buckling Restrained Braces in a 50-Storey Building

Cold-Formed Steel Special Bolted Moment Frames: Cyclic Testing and Numerical Modeling of Moment Connections

Seismic design of braced frame gusset plate connections

ON DRIFT LIMITS ASSOCIATED WITH DIFFERENT DAMAGE LEVELS. Ahmed GHOBARAH 1 ABSTRACT

DESIGN ASPECTS AFFECTING THE SEISMIC BEHAVIOUR OF STEEL MRF BUILDINGS: ANALYSIS OF THREE CASE STUDIES

4.6 Procedures for Connections

HYBRID MOMENT FRAMES AND UNBONDED PT SHEAR WALLS

PERFORMANCE BASED SEISMIC EVALUATION OF MULTI-STOREYED REINFORCED CONCRETE BUILDINGS USING PUSHOVER ANALYSIS

Supplemental Structural Correction Sheet Steel Brace Frame Design (2017 LABC)

FINITE ELEMENT ANALYSIS OF REINFORCED CONCRETE BRIDGE PIER COLUMNS SUBJECTED TO SEISMIS LOADING

In-Plane and Out-of-Plane Performance of the MINI-MC Flange Connector

CONTENT. Self-Centering Earthquake Resisting Systems. Andre Filiatrault, Ph.D., Eng. 1. Introduction

Structural Systems with Enhanced Seismic Resiliency Using High-Performance Materials

Modelling of RC moment resisting frames with precast-prestressed flooring system

Deformation Capacity of RC Structural Walls without Special Boundary Element Detailing

Survey and Testing of Pre-1988 Braced Frame Structures From The West Coast of the United States

POST-TENSIONED CONNECTION SYSTEMS FOR SEISMIC-RESISTANT STEEL FRAMES

Performance based Displacement Limits for Reinforced Concrete Columns under Flexure

Seismic Performance Assessment of Concentrically Braced Steel Frame Buildings

DESIGN OF HIGH-RISE CORE-WALL BUILDINGS: A CANADIAN PERSPECTIVE

PERFORMANCE OF ECCENTRICALLY BRACED FRAMES UNDER THE ACTION OF LATERAL LOAD

THE USE OF FRICTION DAMPERS FOR SESIMIC RETROFIT OF THE MONTEREY COUNTY GOVERNMENT CENTER

Determine Seismic Coefficients of Structural Using Pushover Nonlinear Analysis

SEISMIC RESPONSE OF MULTIPLE-ANCHOR CONNECTIONS TO CONCRETE

Fragility Curves for Seismically Retrofitted Concrete Bridges

SHAKE TABLE TESTING OF BRIDGE REINFORCED CONCRETE COLUMNS UNDER COMBINED ACTIONS

Experimental Evaluation of a Multi-Story Post-Tensioned Coupled Shear Wall Structure

PUSHOVER ANALYSIS FOR THE RC STRUCTURES WITH DIFFERENT ECCENTRICITY

FLOOR AND ATTACHED COMPONENT SEISMIC AMPLIFICATION FACTORS FROM NONLINEAR TIME-HISTORY ANALYSIS

OPTIMUM POSITION OF OUTRIGGER SYSTEM FOR HIGH RAISED RC BUILDINGS USING ETABS (PUSH OVER ANALYSIS)

RESILIENT INFRASTRUCTURE June 1 4, 2016

CTBUH Technical Paper

Interpretation of SECTION 12 DESIGN AND DETAILING FOR EARTHQUAKE LOADS IS

Design Example 2 Reinforced Concrete Wall with Coupling Beams

Consideration of torsional irregularity in Modal Response Spectrum Analysis

EXPERIMENTAL RESULTS

Dynamic Stability of Elastomeric Bearings at Large Displacement

Seismic Behaviour of RC Shear Walls

ADVANCED SEISMIC TESTING USING THE MULTI-AXIAL TESTING SYSTEM (MATS) IN NCREE

steelwise WHAT S NEW WITH PREQUALIFIED CONNECTIONS? A look at the latest version of AISC 358.

International Journal of Engineering Research And Management (IJERM) ISSN: , Volume-03, Issue-11, November 2016

PUSHOVER ANALYSIS OF A 19 STORY CONCRETE SHEAR WALL BUILDING

PERFORMANCE STUDY OF RETROFITTED GRAVITY LOAD DESIGNED WALL FRAME STRUCTURES (SC-140)

DESIGN OF GRAVITY-LOAD RESISTING FRAMES FOR SEISMIC DISPLACEMENT DEMANDS

STEEL MOMENT FRAME DAMAGE PREDICTIONS USING LOW-CYCLE FATIGUE

PERFORMANCE-BASED SEISMIC DESIGN OF BRACED-FRAME GUSSET PLATE CONNECTIONS

SEAU 5 th Annual Education Conference 1. ASCE Concrete Provisions. Concrete Provisions. Concrete Strengths. Robert Pekelnicky, PE, SE

Seismic Design Recommendations for PT Slab-Column Connections

PERFORMANCE- BASED SEISMIC DESIGN OF A BUILDING

DESIGN OF STEEL FRAMES OF DISSIPATIVE SHEAR WALLS

Effect of Concentric Braces on the Behaviour of Steel Structure by Pushover Analysis

ECCENTRICALLY BRACED FRAME DESIGN FOR MODERATE SEISMIC REGIONS

SEISMIC LOSS ASSESSMENT OF EXISTING TALL STELL BUILDINGS IN LOS ANGELES

Compression Behavior, Strength, and Ductility of Confined Concrete after Inelastic Tensile Cyclic Loading

Gravity Load Collapse of Reinforced Concrete Columns with Brittle Failure Modes

INTERNATIONAL JOURNAL OF PURE AND APPLIED RESEARCH IN ENGINEERING AND TECHNOLOGY

ctbuh.org/papers Seismic Performance of High-Rise Intermediate Steel Moment Frames Title:

DISTORTION-INDUCED FATIGUE CRACKING AT WEB-GAP OF WELDED I-BEAMS

Supplemental Structural Correction Sheet Steel Moment Frame Design (2017 LABC)

Fagà, Bianco, Bolognini, and Nascimbene 3rd fib International Congress

Nonlinear Finite Element Modeling & Simulation

Static Analysis of Multistoreyed RC Buildings By Using Pushover Methodology

CHAPTER 8 THE DESIGN AND ANALYSIS OF MULTI-STORY BUILDINGS WITH LARGE MOMENT END-PLATE CONNECTIONS 8.1 INTRODUCTION

Transcription:

EARTHQUAKE SIMULATIONS ON A SELF-CENTERING STEEL MOMENT RESISTING FRAME WITH WEB FRICTION DEVICES Ying-Cheng Lin 1, James Ricles 2, and Richard Sause 3 1 Graduate Research Assistant, ATLSS Center, Department of Civil and Environmental Engineering, Lehigh University, 117 ATLSS Drive, Bethlehem, PA 18015, USA 2 Bruce G. Johnston Professor of Structural Engineering, ATLSS Center, Department of Civil and Environmental Engineering, Lehigh University, Bethlehem, PA 18015, USA 3 Joseph T. Stuart Professor of Structural Engineering, ATLSS Center, Department of Civil and Environmental Engineering, Lehigh University, Bethlehem, PA 18015, USA ABSTRACT : Email: ycl206@lehigh.edu, jmr5@lehigh.edu, rsause@lehigh.edu A self-centering moment resisting frame (SC-MRF) is a viable alternative to a conventional MRF for seismic resistant buildings. An SC-MRF is characterized by gap opening and closing at the beam-column interface under earthquake loading. The beams are post-tensioned to columns by high strength post-tensioning (PT) strands oriented horizontally to provide self-centering forces when gap opening occurs. For the SC-MRF investigated in this research, energy dissipation is provided by web friction devices (WFDs) on the beam. The PT strands and WFD each contribute to the moment capacity of the MRF connections. The SC-MRFs in this study are designed to meet several seismic performance objectives. These include no damage under the Design Basis Earthquake (DBE), leading to immediate occupancy performance following the DBE. In addition, under the Maximum Considered Earthquake (MCE) the structure is designed to have minimal damage and achieve the collapse prevention performance. A 7-bay, 4-story SC-MRF prototype building located on stiff soil in the Los Angeles area was designed with WFDs using a performance-based design procedure with the above performance objectives. A 0.6-scale model of two bays of the SC-MRFs was developed and tested at the NEES equipment site located at Lehigh University using the hybrid simulation method to include other parts of the building in the test. This paper presents an overview of the performance-based design procedure, the test results, and an assessment of the design procedure by a comparison of the test results with the expected performance of the SC-MRF. KEYWORDS: Steel structures, self-centering MRF, post tensioning, web friction devices, beam-to-column connection, gap opening, hybrid simulation, performance-based design 1. INTRODUCTION Conventional moment resisting frames (MRFs) are designed to dissipate energy under the design earthquake by developing damage in the members. This damage can result in large residual drift after the earthquake. To avoid large residual drift, post-tensioned (PT) beam-to-column connections for self-centering (SC) MRF were developed by Ricles et al. (2001). These connections develop a gap opening at the beam-column interface. The PT force enables the connection to self-center upon unloading. Energy dissipation occurs in special devices designed for the connection. This paper presents an experimental study on a self-centering MRF (SC-MRF) with web friction devices (WFDs). The WFDs are used as energy dissipating devices and are positioned on the beam web to avoid interference with the floor slab. Using a performance based design (PBD) approach the SC-MRF is designed to be damage-free under the Design Based Earthquake (DBE) and enable immediate occupancy,

while also achieving the performance level of collapse prevention under the Maximum Considered Earthquake (MCE). Test results are presented and discussed to assess the design approach. 2. CONNECTION OVERVIEW AND BEHAVIOR 2.1. Connection Details Figure 1(a) shows a SC-MRF with post-tensioned WFD (PT-WFD) beam-to-column connections. The PT strands are shown running parallel to the beams across multiple bays. A WFD connection, shown in Figure 1(b), includes two channel sections (referred to as friction channels) welded to column flange. Brass cartridge plates are sandwiched between the webs of the channels and beam to enable reliable friction to occur at their interface. The channels are clamped to the beam web by tightening the friction bolts shown in Figure 1(b) to produce the normal force on the friction surface. The channels are welded to the column flange after the friction bolts are tightened. The channel shape is selected to reduce the effect of weld shrinkage on the normal force on the friction surface. The shim plates shown in Figure 1(b) are welded to the column face to provide good contact surfaces for the beam flanges. Slotted holes are used in the beam web to accommodate the travel of the friction bolts during gap opening and closing of the connection. Reinforcing plates welded on the outside faces of the beam flanges are used to avoid excessive yielding in the beam flanges. Reinforcing plates are also welded to the inside faces of the column flanges to prevent low-cycle fatigue of the column flanges where holes for the PT strands are located. The reinforced net section area of each column flange is at least 85% of the flange gross area. 2.2. Moment-Rotation Behavior The conceptual moment-relative rotation (M-θ r ) behavior for a PT-WFD connection under cyclic loading is shown in Figure 1(c). From event 0 to 1, the connection has an initial stiffness that is similar to a conventional welded moment connection. Once the connection overcomes the imminent gap opening moment at event 1 (M IGO, ), where the M IGO is the sum of the decompression moment M d due to the initial PT force and the moment M Ff due to friction in the WFD, the beam tension flange loses contact with the shim plate at the column face and gap opening occurs. After the M IGO is overcome, the moment at the connection continues to increase as the PT force increases with strand elongation due to the gap opening (event 1 to 2). A large gap opening will eventually yield the PT strands at event 3. During unloading between events 2 and 4, θ r remains constant but the connection moment decreases by 2M Ff due to the reversal in direction of the friction force in the WFD. Continued unloading between events 4 and 5 reduces θ r to zero as the beam tension flange comes in contact with the shim plate at the column face. Further unloading (between events 5 and 6) decreases the moment to zero as the beam tension flange fully compresses against the shim plate. A similar behavior occurs when a reversal in the applied moment occurs. After gap opening, the moment M in the PT-WFD connection is controlled by the axial force P in the beam and friction force resultant F f in the WFD, as follows: M = Pd 2 + F f r (1) In Eqn. (1) d 2 is the distance from the centroid of the beam section to the center of rotation (COR) of the connection, and r is the distance from the friction force resultant to the COR. The COR occurs at the point of contact of the compression beam flange with the column. Considering that a floor diaphragm force F fd develops from the interaction of the SC-MRF with the floor system and the PT force T, the axial force in the beam P is (Garlock et al., 2005): where P = F fd + T (2)

T = T o + θ r [2 d 2 k b k s / ( k b + k s )] (3) In Eqn. (3) T o is the initial PT force; and k b and k s are the axial stiffness of the beam and the PT strands within one bay, respectively. 3. PERFORMERCE BASED DESIGN A performance-based design (PBD) procedure is used for the SC-MRF studied in this research. The PBD considers two levels of seismic hazard, namely the DBE and MCE. Under the DBE (which is equal to two-thirds the intensity of the MCE, and has an approximate 10% probability of being exceeded in 50 years) the SC-MRF is designed to achieve the immediate occupancy (IO) performance level defined in FEMA 450 (FEMA 2000), where limited structural and nonstructural damage occurs. Under the MCE (which has a 2% probability of being exceeded in 50 years), the collapse prevention (CP) performance level (FEMA 2000) should be achieved. The design objectives and the limit states of the SC-MRF with PT-WFDs connections are shown in the conceptual base shear-roof drift (V-θ roof ) response in Figure 2. Before the IO performance level, connection decompression and minimal yielding at the column bases of the SC-MRF is permitted to occur. Panel zone yielding, beam web yielding, and a beam flange strain greater than twice the yield strain is designed to occur between the IO and CP levels. At the CP level, PT strand yielding, beam web buckling, and excessive story drift are not permitted. The details of the design procedure are given in Garlock et al., (2005). 4. CONNECTION DESIGN The effective energy dissipating ratio (β E ) of a PT-WFD connection expresses its energy dissipation characteristics. It can be shown that for a PT-WFD connection, the β E can be determined as follows: β E = M Ff / M IGO (4) To enable a satisfactory response for the SC-MRF under seismic loading to be achieved, Seo and Sause (2005) recommend that 0.25 β E. In addition, the target value of M IGO / M des = 0.95 is used, based on studies by Garlock (2002) and Rojas (2003). M des is the design moment determined by an equivalent lateral force (ELF) analysis of the SC-MRF using a model of the MRF with rigid connections subject to the design forces associated with the design base shear V des defined in ASCE7-05 by using the response modification factor R equal to 8. 5. EXPERIMENTAL PROGRAM Using the design criteria and PBD approach described above, a 7x7-bay 4-story prototype building shown in Figure 3(a) was designed. The building is located on stiff soil in the Los Angeles. The perimeter frames include SC-MRFs. Each perimeter frame has two 2-bay SC-MRFs with PT-WFD connections. Figure 3(a) also shows the floor diaphragm is attached to one bay of each SC-MRF in each perimeter frame to avoid restraining the PT-WFDs connections from developing gap opening. 5.1. Test Structure and Test Setup The test structure for the experimental program consisted of a 0.6-scale 4-story 2-bay SC-MRF with

PT-WFD connections, and is shown in Figure 3(b). A992 steel sections were used throughout the test structure. The member sizes are scaled down from the prototype structure. The test structure has W10x88 columns, W18x55 and W18x50 floor beams, and W14x34 roof beams. The Table 1 summarizes the SC-MRF design demands for roof drift (θ roof ), story drift (θ s ), and connection relative rotation (θ r ) under the DBE and MCE levels. The first mode period for the test structure is 1.23 second. The initial PT forces T o, included in Figure 3(b), are less than 45% of ultimate strength (T u ). During the test, the lateral force at each level is applied through a floor diaphragm consisting of a loading beam system attached to the middle of the beam in the north bay by an actuator shown in Figure 3(b). The hybrid simulation method was used for the tests involving frequently occurring earthquake (FOE), DBE, and MCE tests discussed below. The test frame was the experimental substructure for the simulation. The gravity load bearing system and gravity loads tributary to the test structure were an analytical substructure in the hybrid simulation. The hybrid simulation used 2% damping in the 1st and 3rd modes, and an analytical model for the tributary mass of the test structure. The explicit unconditionally stable CR integration algorithm developed by Chen and Ricles (2008) was used to solve the equations of motion. 5.2. Test Matrix Table 2 shows the test matrix. For the static tests, tests to obtain the stiffness matrix of the test frame and pushover tests to verify the behavior of the PT-WFD connections under cyclic loading were performed. The stiffness matrix was obtained by using the flexibility method. For the hybrid simulation tests, ground motion records for FOE, DBE, and MCE levels were selected to assess the PBD method by comparing experimental results with the expected design objectives described previously. DBE-1 is a low-level DBE ground motion where no damage, including the column base yielding is expected to occur for DBE-1. From time history analysis, the expected value of roof drift, story drift, and connection relative rotation are about half of the design demands shown in Table 1. Tests with more demanding earthquake records (DBE-2, DBE-3, Aftershock, and MCE) are yet to be performed. 6. EXPERIMENTAL RESULTS This paper focuses on the test results from DBE-1. Figure 4 shows the floor displacement time history from this test. The residual story drifts of the test frame are given in Table 3, and were obtained by dividing the difference between adjacent floor displacements by the story height. The maximum residual story drift is less than 0.2% radian, which demonstrates the self-centering capability of the SC-MRF. Test results for DBE-1 test are shown in Table 4, and include maximum story drift θ s max, maximum relative rotation θ s max, maximum PT force T max and residual PT force after the simulation T o,dbe normalized by the strand tensile strength T u. The maximum θ s,max is 1.9% radians and θ r,max is 1.7% radians, which are about one-half of the expected design demand from Table 1 for the DBE. A plot of the PT force versus the average θ r for each floor is given in Figure 5. The results show an increase in PT force when the gap opening occurs at the PT-WFD connections. The maximum PT forces for the DBE-1 test were 0.52T u in the test (see Table 4). No yielding occurred in PT strands. The PT strand force decreased by a small amount during the test due to seating of the PT strand anchorage. Values for T o,dbe in Table 4 are less than the initial pre-stress level of 0.45T u. The M-θ r response for the 2 nd floor south-bay beam connections are shown in Figure 6. The self-centering capability is demonstrated in Figure 6 where θ r returns to zero upon unloading of the connection. After gap opening, the stiffness is different in the positive and negative moment directions. This is due to the effect of the floor diaphragm forces (i.e., the lateral force for the actuators) applied to the north bay beam. When structure is loaded to north direction, the floor diaphragm force imparts tension force in the south bay beam.

When structure is loaded to the south, the floor diaphragm imparts compression force in the south bay beam. Therefore, in Eq. (1) the axial force P in the south bay is different for the different loading directions. The estimated β E is shown in Table 5 for each floor level, and was calculated by Eq. (4) using estimated M Ff and M IGO from the M-θ r responses. Most of the floors have a β E which is less than 25%, except for the 3 rd floor. The low β E indicated the friction forces in the WFDs were lower than the design target values, which were 24.3% for 1 st floor, 25.5% for 2 nd floor, 33.9% for 3 rd floor, and 31.7% for the roof. In general, the WFD connections in the SC-MRF performed very well. Friction forces in the WFDs can be adjusted by retightening the friction bolts to provide greater energy dissipation. 7. SUMMARY AND CONCLUSIONS The SC-MRF with PT-WFD connections performed well under the DBE-1 ground motion and in accordance with the objectives of the PBD. No damage occurred during the DBE-1. The test results demonstrate the self-centering capability of the SC-MRF. The WFDs are shown to provide energy dissipation, which can be adjusted by the amount of pretension in the friction bolts. Additional tests will be performed involving earthquake records that impose greater demand on the test structure. The PBD for the SC-MRF will be further assessed based on the results from these tests. 8. ACKNOWLEDGEMENTS The research reported in this paper was conducted at the NEES Real-Time Multi-Directional (RTMD) Earthquake Testing Facility located at the ATLSS Center at Lehigh University. The work was supported by the National Science Foundation under Grant No. CMS-0420974, within the George E. Brown, Jr. Network for Earthquake Engineering Simulation Research (NEESR) program and Award No. CMS-0402490 NEES Consortium Operation. REFERENCES Chen, C., Ricles J.M. (2008), Development of Direct Integration Algorithms for Structural Dynamics Using Discrete Control Theory, Journal of Engineering Mechanics, ASCE; 134:8, 676-683. FEMA. (2000), NEHRP Recommended Provisions for Seismic Regulations for New Buildings and Other Structures. Part 1 Provisions and Part 2 Commentary, FEMA 450, Federal Emergency Management Agency, Washington, D.C. Garlock, M. (2002), Full-Scale Testing, Seismic Analysis, and Design of Post-Tensioned Seismic Resistant Connections for Steel Frames, Ph.D. Dissertation, Civil and Environmental Engineering Dept., Lehigh University, Bethlehem, PA Garlock M., Sause R., Ricles J.M. (2005), Behavior and Design of Post-tensioned Steel Frame Systems, Journal of Structural Engineering, ASCE; 133:3, 389-399. Ricles J.M., Sause R., Garlock M., Zhao C. (2001), Post-Tensioned Seismic-Resistant Connections for Steel Frames, Journal of Structural Engineering, ASCE; 127:2, 113-121. Rojas P. (2003), Seismic Analysis, Design, and Evaluation of Post-tensioned Friction Damped Connections for Steel Moment Resisting Frames, Ph.D. Dissertation, Department of Civil and

Environmental Engineering. Lehigh University. Seo, C-Y., Sause R. (2005), Ductility Demands on Self-Centering Systems under Earthquake Loading, ACI Structural Journal; 102:2, 275-285. Wolski M., Ricles J.M., Sause R. (2008), Experimental Study of Self-centering Beam-column Moment Connections with a Bottom Flange Friction Device, Journal of Structural Engineering, submitted for publication. Table 1 Design demands (in radians) θ roof.,dbe θ s.,dbe θ r.,dbe θ roof.,mce θ s.,mce θ r.,mce 0.026 0.039 0.031 0.039 0.059 0.047 Table 2 Test matrix Tests Description Ground Scale Test Motion Factor Method Record Stiffness Stiffness matrix determination -- -- Static Pushover WFD connection behavior check -- -- Static FOE-1 1979 Imperial Valley H-CXO225 0.700 FOE-2 1979 Imperial Valley H-CXO225 1.410 DBE-1 1979 Imperial Valley H-ECC002 0.943 Pseudodynamic DBE-2 1989 Loma Prieta SJTE315 1.533 DBE-3 1994 Northridge LOS000 1.182 MCE tbd tbd tbd Aftershock tbd tbd tbd Table 3 Residual story drift after DBE-1 (in radian.) Story 1 st 2 nd 3 rd 4 th Drift 0.028% 0.082% 0.142% 0.187% Table 4 Test results for DBE-1 Level θ s max θ r max T max /T u T o,dbe /T u (radians) (radians) (%) (%) RF 0.019 0.017 49 43 3F 0.018 0.015 47 38 2F 0.019 0.014 52 43 1F 0.012 0.014 51 44 Table 5 Estimated β E for DBE-1 Level 1F 2F 3F RF β E 22% 18% 28% 15%

Figure 1 Schematic of (a) Elevation of a 2-bay SC-MRF with PT strands and WFDs, (b) Connection details, and (c) Conceptual moment-relative rotation (M-θ r ) behavior of connections with WFDs. Figure 2 Performance based design objectives (b) N Figure 3 Schematic of (a) Plan of prototype, and (b) Elevation of 0.6-scale 4-story 2-bay SC-MRF test frame.

Flr. Disp. (in.) 6 4 2 0-2 -4-6 0 2 4 6 8 10 12 14 Time (sec.) Figure 4 Floor displacements time history, DBE-1 RF 3F 2F 1F (a) PT Force (kips) 260 240 220 200 180 160 (b) 260 240 220 200 180 160 PT Force (kips) (c) 180 Avg. θr (rad.) 160 140 120 100 80 (d) 100 Avg. θr (rad.) 90 80 70 60 50 40 Avg. θr (rad.) Avg. θr (rad.) Figure 5 PT force vs. average θ r, DBE-1 (a) 1 st Floor; (b) 2 nd Floor; (c) 3 rd Floor; (d) Roof (a) 3000 (b) 3000 2000 2000 M (kip-in) 1000 0-1000 M (kip-in) 1000 0-1000 -2000-3000 -2000-3000 θr (rad.) θr (rad.) Figure 6 Moment vs. θ r of (a) South-end connection and (b) North-end connection of the 2 nd floor south-side beam, DBE-1