Low-dose and High-resolution Cardiovascular Imaging with Revolution* CT

Similar documents
GE Healthcare. Introducing Veo * on Discovery * CT750 HD Great care by design

GENESIS Edition Transforming CT

GE Healthcare. Optima NM/CT 640

GE Healthcare. Optima * CT660 Second Edition

GENESIS Edition. Transforming CT

Leading Canadian Pediatric Hospital Continues to Drive Dose Down for Sick Children

Computed Tomography: Optimization of acquisition protocols & Justification of clinical referrals. Koos Geleijns, medical physicist

A New Standard for the Future

GE Healthcare LOGIQ P3. Advancing your imaging capabilities

Handzettel 1. CARE Right Computed Tomography, committed to the right dose Ivo Driesser Austin, July 22 nd 2014

Extending quality care to more people. Brivo CT315

Your diagnostic partner. Every day. Optima* CT540

GE Healthcare. Vivid S6. Cardiovascular ultrasound system

Future bound. Philips Ingenuity Core

Optima IGS 330 Versatility within your reach. gehealthcare.com

Low Dose, Lightning Speed, Latest Applications

Recharge your MR experience.

CTA Throughout the Ages

MAC 800 Resting ECG System. Connecting hearts and minds.

Computed Tomography. Printed in Japan

Every Day is a CardioDay. Speed. Accuracy. Ease of Use. CardioDay

GE Healthcare. EchoPAC Dimension 06. Clinical workstation


The time has come. Philips GEMINI TF PET/CT with TruFlight technology

low Dose, Lightning Speed

2017 ACR Computed Tomography Quality Control Manual FAQS

Advanced digital radiographic system powered by FlashPad.

Aquilion ONE ViSION EDITION

The World s First Adaptive Scanner

GE Healthcare. OEC 9800 Plus. A Classic Choice

Optimize efficiency with a universal system.

GE Healthcare LOGIQ 7

LOGIQ S8 with XDclear Simply Amazing

GE Medical Systems Ultrasound LOGIQ 5 PRO. TruScan Imaging Technology. GE imagination at work

Progress in X-Ray & MR

I M A G E G U I D E D R A D I A T I O N T H E R A P Y. Elekta XVI. Inspiring clinical confidence

Jonathon A. Nye, Ph.D Emory University School of Medicine Atlanta, GA

Voluson S8. Extraordinary vision Signature Series

Department of Radio Diagnosis

Motiva: a TV-based platform for remote patient management

Clinical Applications. ImagingRite. Interventional Radiology

Minimum Detectability and Dose Analysis for Size- based Optimization of CT Protocols. Christopher Craig Smitherman

Making the difference with Live Image Guidance

Effective Date: April 19, 2018 TITLE: GUIDELINE FOR RADIATION SAFETY COMMITTEE REVIEW OF HUMAN RESEARCH STUDIES. Table of Contents

Optimization of Low-Dose CT Protocol in Pediatric Nuclear Medicine Imaging

Fluoroscopy units come in many different physical configurations but all consist of the main components shown in this slide.

Image guided therapy. Azurion 7. With Azurion, performance and superior care become one

Implementing Optimal Kidney Stone CT Protocols Using Outreach from a National Database. Purpose

New PET/CT from Siemens helps more patients benefit from premium technologies

Clinical Applications. ImagingRite. Neuro Intervention. 1 ImagingRite

better images mean better results

Artis Q and ArtisQ.zen

Gastrointestinal Imaging Original Research

AAPM IGRT Recommendations

GE Healthcare. GoldSeal. Refurbished imaging systems. Reliable quality. Certified confidence.

M7 Hand-carried Ultrasound System

Vantage Titan 1.5T MR. The Intelligent Choice.

CT QA SOLUTIONS. Ensure Accurate Screening, Diagnosis and Monitoring

GE Healthcare. Mobile X-ray Systems. Intuitive. Integrated. Practical.

One exam. One workflow. Immeasurable versatility.

Symbia TruePoint SPECT CT. Working For You.

GE Healthcare. Brivo DR-F. Simply digital.

Delivering top performance. Outstanding value. Diagnostic scalability. ACUSON X150 Ultrasound System.

Protecting Patients 3/5/2014. Educating and Engaging your Staff in Radiation Safety

CT of the Abdomen with Reduced Tube Voltage in Adults: A Practical Approach 1

Excellence on the Move

IAEA-TECDOC Dose Reduction in CT while Maintaining Diagnostic Confidence: A Feasibility/Demonstration Study

Intuitive 3D catheter guidance. Philips EP navigator and 3D rotational scan

Automated Breast Volumes. Simplified.

DuoFLEX. MRI Coil Suite. Flexible coils that contour to your patient and your budget.

Q-STRESS CARDIAC STRESS TESTING SYSTEM

Donna Newman B.A. RT ( R) CNMT Director of Professional Practice ISRRT

LOGIQ Book High Performance Hand-carried Ultrasound

Centricity * Precision Reporting

UNTAPPED POTENTIAL PART 1 OF 3 How Radiology Administrators made the most of their CT investments

R/F. Experiences Using SONIALVISION safire and the Utility of Tomosynthesis. 1. Introduction. 2. Basics of Tomosynthesis.

Vivid iq. The power to take you places.

New Product Innovation Leadership

Treatment Quality Assurance Cone Beam Image Guided Radiation Therapy. Jean-Pierre Bissonnette, PhD, MCCPM

Disclaimer and Notices.

Is there a way to unify economical and ecological demands in healthcare?

Join the World of CT SOMATOM Spirit

First Experiences with the Ziehm Vision FD Mobile C-Arm with Flat-Panel Detector

TENDER # SUPPLY OF MOBILE C-ARM RADIOGRAPHY/FLUOROCOPY SYSTEM FOR WESTERN HEALTH

Ingenia MR-RT. MR Systems. The comprehensive MR-sim solution to fit your planning

Contrast Dose Management. For CT and MR

siemens.com/mct-flow Biograph mct Flow Moving the standard to personalized care.

A dosimetric trial for the clinical follow-up of potential skin injuries on patients undergoing interventional cardiology procedures

IMV 2006 CT Market Summary Report Featuring results from 2,565 hospital and non-hospital CT imaging sites in the United States

Centricity Cardio Workflow Customizable workflows bring order to a complex care area

Quantification in emission tomography: challenges, solutions, performance and impact

Connect. Collaborate. Transforming Cardiovascular Care.

Transcription:

GE Healthcare Case study Low-dose and High-resolution Cardiovascular Imaging with Revolution* CT Jean-Louis Sablayrolles, M.D. Laurent Macron, M.D. Jacques Feignoux, M.D. Centre Cardiologique du Nord, Saint-Denis, France

Case 1 Rapid and Precise Coronary CT Angiography A woman in her 60s with multiple risk factors and complaining about atypical chest pain was referred to CT for coronary assessment. One-beat cardiac acquisition: - 120 mm axial scanning with ECG gating - kv Assist & SmartmA to tailor dose to patient s morphology: 80 kv, 370 ma, Noise Index 30 - BMI: 23 - ASiR*-V 1 to lower dose - 0.28 sec rotation speed - Heart rate: 69 BPM - 60 cc of contrast media (350 mg I/ml) including SmartPrep phase (automated threshold-based triggering) - DLP 18 mgy-cm - 0.25 msv 2 - Exposure time: 0.28 sec 3D Coronary Tree Curved - LAD Curved - RCA On this patient with a relatively high heart rate (77 BPM before apnea, 69 BPM during acquisition), the exam was performed within a single diastolic phase, at 80 kv, enabling diagnostic quality images to be acquired at a quarter of a millisievert. Thanks to the one-beat axial acquisition, the new iterative reconstruction technology ASiR-V and the high image quality at low kv, Revolution CT delivers cardiac CT with excellent image quality at very low dose routinely. Jacques Feignoux

Case 2 Conclusive Triple-Rule-Out Study Without Compromise A woman in her 50s, complaining of paroxysmal chest pain for one month and presenting with left ventricular hypertrophy, was referred to CT for triple-rule-out after a vasovagal episode related to stress. Axial scanning with ECG gating: - Smart coverage to automatically select anatomy specific collimations required to scan the prescribed area - kv Assist & SmartmA to tailor dose to patient s morphology: 80 kv, 295-320 ma, Noise Index 30 - BMI: 17 - ASiR-V 1 to lower dose - 0.28 sec rotation speed - Heart rate 56-69 BPM - DLP 36 mgy-cm - 0.5 msv 2 - Coverage: 240 mm - Exposure time: 0.56 sec Thanks to the 160 mm coverage, this exam was performed with two axial volumes for optimal visualization of pulmonary arteries, thoracic aorta and motion free coronaries. The new generation of iterative reconstruction ASiR-V delivers diagnostic image quality at half a millisievert. With Revolution CT, triple-rule-out studies are now robust and reproducible with easy synchronization with contrast injection and lower dose, with uncompromised image quality. Jean-Louis Sablayrolles

Case 3 Detailed Head & Neck CT Angiography at Low Dose A man in his 70s was referred to CT for follow-up of a stenosis of the right internal carotid. - Helical mode - Pitch 0.992:1 - kv Assist & SmartmA to tailor dose to patient s morphology: 120 kv, 35-320 ma, Noise Index 25 - BMI: 26 - ASiR-V 1 to lower dose - 0.5 sec rotation speed - 50 cc of contrast media (350 mg I/mL) including SmartPrep phase (automated threshold-based triggering) - DLP 175 mgy-cm - 0.9 msv 3 - Coverage: 300 mm - time: 1.9 sec This head and neck angiography was performed in less than two seconds with highresolution images at less than one millisievert. With Revolution CT, faster head and neck angiography allows for uniform contrast in pure arterial phase, with no venous contamination. Therefore, it gives us the imaging accuracy that we need to provide a confident diagnosis to referring clinicians. Laurent Macron

Case 4 Low-dose and High-resolution Runoff CT Angiography A man in his 60s was referred to CT for follow-up of lower limb arteriopathy. - Helical mode - Pitch 0.984:1 - kv Assist & SmartmA to tailor dose to patient s morphology: 100 kv, Noise Index 26 - BMI: 22 - ASiR-V1 to lower dose - 1 sec rotation speed - DLP 226 mgy-cm - 2 msv 4 - Coverage: 1210 mm - time: 35 sec This exam demonstrates the need of high spatial resolution for a confident diagnosis in severe arteriopathy cases. The significant dose reduction capabilities of ASiR-V allowed us to get this high image quality at only 226 mgy-cm. Revolution CT provides the flexibility to perform vascular examination using multi-volume axial imaging or helical mode with up to 80 mm collimation to optimize the results while delivering low dose thanks to ASiR-V. Jean-Louis Sablayrolles Enabling Technologies Revolution CT puts the next generation of iterative reconstruction, ASiR-V, up to 160 mm of multivolume axial scanning and up to 80 mm collimation for helical scanning in your hands, helping you acquire high-definition images at lower doses. ASiR-V 1 was designed to deliver reduced noise levels and improve low-contrast detectability so you can routinely reduce dose up to 82% relative to FBP at the same image quality 5 for patients of all ages. Revolution CT introduces the groundbreaking Gemstone Clarity Detector that gives you 160 mm whole organ coverage with best-in-class spatial resolution. The focally-aligned, miniaturized detector modules and 3D collimator are designed to reduce electronic noise by 25% which may improve image quality and reduce artifacts in low signal conditions, for example in large patients or when scanning at low kv and ma. Revolution CT features also the latest Smart Dose technologies designed to help you acquire high quality images using lower doses of radiation. Smart Dose technologies may help you make a more accurate diagnosis and lower exposure for patients across routine and advanced exams, including dynamic acquisitions for perfusion and 4D studies. Smart Dose technologies include kv Assist that helps you select the right settings for the patient being scanned. It recommends tube voltage and current to achieve the lowest dose while meeting your image quality goals. Finally, Revolution CT allows 70 kv scanning so you can develop low-dose protocols, which are especially suitable for pediatric imaging.

About GE Healthcare GE Healthcare provides transformational medical technologies and services to meet the demand for increased access, enhanced quality and more affordable healthcare around the world. GE (NYSE: GE) works on things that matter - great people and technologies taking on tough challenges. From medical imaging, software & IT, patient monitoring and diagnostics to drug discovery, biopharmaceutical manufacturing technologies and performance improvement solutions, GE Healthcare helps medical professionals deliver great healthcare to their patients. GE Healthcare 3000 N. Grandview Blvd. Waukesha, WI 53188 USA gehealthcare.com @GEHealthcare GE imagination at work 2014 General Electric Company All rights reserved. General Electric Company reserves the right to make changes in specification and features shown herein, or discontinue the product described at any time without notice or obligation. GE and GE Monogram are trademarks of General Electric Company. GE Healthcare, a division of General Electric Company. *Trademark of General Electric Company. The clinical cases are displayed for educational purposes only and for the benefit of healthcare students and professionals 1 In clinical practice, the use of ASiR-V may reduce CT patient dose depending on the clinical task, patient size, anatomical location and clinical practice. A consultation with a radiologist and a physicist should be made to determine the appropriate dose to obtain diagnostic image quality for the particular clinical task. 2 Obtained using a chest factor of 0.014*DLP 3 Obtained by EUR-16262 EN, using a head and neck CTA conversion factor of 0.0049*DLP 4 Obtained by EUR-16262 EN, using an adult Runoff factor of 0.009*DLP 5 Image quality as defined by low contrast detectability. Legal Mentions : The system is intended to produce cross-sectional images of the body by computer reconstruction of x-ray transmission projection data from the same axial plane taken at different angles. The system has the capability to image whole organs in a single rotation. Whole organs include but are not limited to brain, heart, liver, kidney, pancreas, etc.. The system may acquire data using Axial, Cine, Helical, Cardiac, and Gated CT scan techniques from patients of all ages. These images may be obtained either with or without contrast. This device may include signal analysis and display equipment, patient and equipment supports, components and accessories. Class: IIb Manufacturer: GE Medical Systems LLC, USA LNE/G-MED NB 0459 GMDN 37618. JB25620XXa