Nutrients recovery of source separated urine by forward osmosis and a pilot scale resources-oriented sanitation system

Similar documents
Urine concentration by forward osmosis process

Technical experience and lessons learned from O&M of a membrane based water plant

Forward Osmosis: Progress and Challenges

Proven Solutions for the Most Challenging Wastewaters

Forward Osmosis Reverse Osmosis Process Offers a Novel Hybrid Solution for Water Purification and Reuse

Membrane-Based Technologies for Sustainable Production of Power

A NOVEL HYBRID FORWARD OSMOSIS- NANOFILTRATION TECHNOLOGY FOR SEAWATER DESALINATION

Forward Osmosis Applications for the Power Industry

A Comprehensive Bench- and Pilot-Scale Investigation of Trace Organic Compound Rejection by Forward Osmosis

Polymer assisted forward osmosis for desalination and water reuse

HTI - Forward Osmosis Overview MSSC 2012

MEMBRANE BIOREACTORS (MBR)

Innovative Sanitation Concepts The German Experience

Sulaibiya world s largest membrane water reuse project

Innovating Water Treatment Technologies in Managing Water-Energy Demand

REVERSE OSMOSIS AND FORWARD OSMOSIS LABORATORY EXPERIMENTS

Application of the AGF (Anoxic Gas Flotation) Process

Almy Fithriana Malisie Ralf Otterpohl Institute of Wastewater Management and Water Protection Hamburg University of Technology

Reclamation of Sand Filter Backwash Effluent using HYDRAcap LD Capillary UF Membrane Technology

Novel source separating sanitation approach for remote tourist facilities at sensitive coastal areas

Operation of a small scale MBR system for wastewater reuse

Malawi Field trials. Emergency Sanitation

Low Fouling and Energy Consumption two-stage Forward and Reverse Osmosis desalination Process

Membrane Filtration Technology: Meeting Today s Water Treatment Challenges

Technical White Paper

Optimum RO System Design with High Area Spiral Wound Elements

MOSES BASITERE 13th IWA Specialized conference on small water and wastewater Systems (SWWS)

Sustainable utilization and practice of urban water system

Boss Water Systems Australia Reverse Osmosis System Model 021-4P-GM

Operating parameters influencing Ultrafiltration of organic model solutions

Low-cost Innovation in Water and Sanitation at a Local Level

Technological options for fecal sludge treatment in urban areas: case study in Beijing

Reverse Osmosis. Lecture 17

Onsite Wastewater Treatment. Biological and Agricultural Engineering Department

5.B Generation of pharmaceutical water Author: Michael Gronwald Co-Author: Dr. Ralph Gomez / Up06

The future in sanitation is off the grid

Challenges in Wastewater Treatment and Management in Asia:

Purple phototrophic bacteria for nutrient recovery from domestic wastewater treatment

Wastewater Treatment Works... The Basics

(c) Tertiary Further treatment may be used to remove more organic matter and/or disinfect the water.

W O C H H O L Z R E G I O N A L W A T E R R E C L A M A T I O N F A C I L I T Y O V E R V I E W

SEPARATION OF OIL WATER EMULSION FROM CAR WASHES

Stress Test Report of the water recovery system in the Blue Diversion Toilet

NEW TECHNOLOGIES FOR THE USE OF WASTE ENERGY FOR DESALINATION

NEW BIOLOGICAL PHOSPHORUS REMOVAL CONCEPT SUCCESSFULLY APPLIED IN A T-DITCH PROCESS WASTEWATER TREATMENT PLANT

Early Onsite Systems

Module 2 : System of Sanitation. Lecture 2 : System of Sanitation

Separation of Ammonia and Phosphate Minerals from Wastewater using Gas-Permeable Membranes. Matias Vanotti

Key words: Integrated Membrane System, IMS, Seawater Reverse Osmosis, SWRO, SW30HRLE- 400, Ultrafiltration, UF, ZeeWeed 1000

INNOVATIVE APPROACHES FOR SUSTAINABLE ENERGY EFFICIENT SWRO DESALINATION

Keywords nanofiltration; capillary membrane; direct treatment; backflush; surface water.

Title: How to Design and Operate SWRO Systems Built Around a New Pressure Exchanger Device

Treatment and Reuse of Tannery Waste Water by Embedded System

Improving Septic Tank Performance by Enhancing Anaerobic Digestion NOWRA Onsite Wastewater Mega-Conference

Reverse Osmosis. Background to Market and Technology

Determination of Total Nitrogen and Phosphorus in Environmental Waters

Fig 1. Flex EDR Ammonia Stack

Ontario s 2012 Building Code Division B, Part 7 Ontario Regulation 332/12

Volume 4 of the World Health Organization s (WHO) Guidelines for the safe use

Characteristics of Nutrient Removal in Vertical Membrane Bioreactors

Fabrication of Reverse Osmosis Spiral Wound Membranes using Local Materials

Steven Dickey. Abstract

Overview of anaerobic treatment options for sustainable sanitation systems Dr. Elisabeth v. Münch (leader of GTZ ecosan program)

Modutech S.r.l. WDS SEAWATER DROPLET SYSTEM FOR FRESH WATER SUPPLY. Ing. Alessandro Cariani

RO400 USER'S MANUAL. Memo PURE-PRO REVERSE OSMOSIS SYSTEM RO400. Type of product. Date of purchase. Address

Engineering, NTUA, 15780, Greece Tel: ; Fax: * Correspondence author

Rainwater harvesting and greywater recovery - Part 3-

Appendix D JWPCP Background and NDN

Kirill Ukhanov, GE Water & Process Technologies, Russia, describes how advanced membrane technology is helping a Russian refinery to meet stringent

Traditional Treatment

Impacts of blackwater co-digestion upon biogas production y in pilot-scale UASB and CSTR reactors

Decentral drinking water and wastewater treatment at De Ceuvel in Amsterdam

Removal of High C and N Contents in Synthetic Wastewater Using Internal Circulation of Anaerobic and Anoxic/Oxic Activated Sludge Processes

BEING GOOD STEWARDS: IMPROVING EFFLUENT QUALITY ON A BARRIER ISLAND. 1.0 Executive Summary

Membrane Biofilm Reactor (MBfR): A New Approach to Denitrification in Wastewater Setting

Reclamation of the Polymer-Flooding Produced Water

High-Flux Polymeric Membrane for Industrial Water Separation

Sanitation Technology Options in Lesotho

A PILOT-SCALE FERTILISER DRAWN FORWARD OSMOSIS AND NANOFILTRATION HYBRID SYSTEM FOR DESALINATION. by Jung Eun Kim

Technological improvements in compact UASB/SBTF systems for decentralized sewage treatment in developing countries

Proposal by Russia to delete hot sub-spot Hot sub-spot name South-West Wastewater Treatment Plant

Forward Osmosis Applied to Desalination and Evaporative Cooling Make-up Water

Crossflow Filtration for Ink Jet Fluids

Novel Engineered Osmosis Technology: A Comprehensive Approach to the Treatment and Reuse of Produced Water and Drilling Wastewater

Watertown Wastewater Facility Plan. August 11, 2015

Ultrafiltration Technical Manual

Recycling of Food Processing Wastewater to Potable Water Standards

Dry Sanitation, Urine Management, Containment Methods and Reuse Potential in Agriculture

Wastewater recycling concept for an urban multi-storey building

Membranes & Water Treatment

d&wr desalination & WATER REUSE

What Is Membrane Performance Normalization?

Flexible Platform Technologies for Resource Recovery from Food Waste

Advanced water and wastewater treatment technologies in Thailand

Recycling wastewater yields multiple benefits. World Congress & Expo on Recycling, July 20-22, Barcelona, Spain

Lagoons Operation and Management in New Brunswick

WASTEWATER TREATMENT SYSTEM

Lenntech. Tel Fax

Microbubbles Generator

Low-cost Options for Treating Faecal Sludges (FS) in Developing Countries

Transcription:

School of Environment, Tsinghua University Nutrients recovery of source separated urine by forward osmosis and a pilot scale resources-oriented sanitation system SWWS 2016, 15 September XU Yangyu, ZHOU Lu* and JIA Qibo Email: zhoulu@tsinghua.edu.cn Tel: +86+10+62773079

Contents 1.Introduction 2.Performance of FO in urine concentration 3.Pilot-scale sanitation system 4.Conclusions

1.Introduction

1.Introduction Source: Bill&Melinda Gates Foundation Disadvantages of end-of-pipe systems: Expensive: lands, energy, water O&M, etc. Human excreta contain large amount of nutrients (N, P, K), crucial for the growth of plants, but costly to eliminate in wastewater.

1.Introduction Urine: Almost sterile 1.5L/(cap d) 1.4% inorganics(k, P, etc.) 1.3% urea Resource recovery Faeces: 0.4kg/(cap d) Harmless 30% bacteria 30% undigested fibers and dead cells Human excreta contribute to >50% N&P in sewage Source separation is important!

1.Introduction Forward osmosis (FO), or direct osmosis uses the osmotic pressure differential(π) across the membrane, as the driving force for transportation of water through the membrane. Cath, 2006; Lutchmiah, 2014; Xue, 2016 Advantages: Low or no hydraulic pressure Membrane support is less of a problem High rejection for a wide range of contaminants Lower membrane fouling tendency Simple equipment and less area occupation

1.Introduction Source separated urine concentration by FO is a promising way for pollution prevention and resource recovery, but studies for FO application in urine concentration has some drawbacks: Low water flux due to the high concentration of urine; Low rejection for nitrogen; Draw solution contamination; Synthetic urine can be different from the practical situation. Zhang, 2014; Xue, 2015; Liu, 2016

2. Performance of FO in urine concentration

2.Performance of FO in urine concentration Feed SolutionTank Pump Valve Pump Flow Meter L FO Test Chamber FO Membrane Feed Solution Electrode L Flow Meter Pump Valve Draw Solution Tank Pump Conductivity Meter Draw Solution Data Aggregation System Electrion Blance 1: fixed splint; 2: strap bolt; 3: flat water channel; 4: draft tube; 5: FO membrane. a: FS; b: DS Feed: synthetic and real urine; Draw: NaCl solution; Membrane: CTA HTI

Water flux/lhm Rejection 2.Performance of FO in urine concentration 2.1.Comparison of different membrane 30,0 25,0 20,0 15,0 10,0 5,0 0,0 AQP CTA TFC RO Modified RO Membrane type 100,0% 80,0% 60,0% 40,0% 20,0% 0,0% The CTA, TFC membrane showed the best performance with water flux of 23.6 LHM and 20.5 LHM, rejection of 99.8% and 99.6% respectively. The modification of the RO membrane contributes to the increase in water flux mainly due to the decrease of concentration polarization.

Water flux /LHM Water flux/lhm 2.Performance of FO in urine concentration 2.2.Influence factors 16,0 16,0 14,0 14,0 12,0 12,0 10,0 10,0 8,0 8,0 6,0 6,0 4,0 4,0 2,0 2,0 0,0 0,0 1,0 2,0 3,0 4,0 Draw solution concentration /M 0,0 10 20 30 40 50 60 70 80 Cross velocity cm/s The water flux increases as the draw solution concentration goes up. The increasing rate declines. Thus, 2M NaCl was used initially. Cross velocity mainly affects the external concentration polarization (ECP), and higher velocity has a positive effect on the decrease of membrane fouling.

2.Performance of FO in urine concentration 2.3.Comparison of synthetic urine and real urine In the practical situation, the separation of urine and faecal matters are not complete. The composition of the urine can be very different from the synthetic urine.

2.Performance of FO in urine concentration 2.3.Comparison of synthetic urine and real urine Urine type TP (mg/l) TN (mg/l) NH 3 -N (mg/l) COD Cr (mg/l) K (mg/l) Synthetic urine Real urine Before 3210±5 12550±5 12440±5 4550±5 840±5 After 6240±5 16950±5 16370±5 7630±5 1480±5 Rejection 97.2% 73.4% 65.8% 83.9% 88.1% Before 2110±5 2460±5 2350±5 4030±5 575±5 After 4140±5 3160±5 2570±5 6960±5 970±5 Rejection 97.9% 64.5% 54.7% 86.3% 84.1% The FO membrane has a high rejection for P, and a relatively low rejection for organics and K. The rejection for nitrogen is not ideal. Nitrogen exists as ammonia, which is similar to the H 2 O molecule. The nutrients concentration of real urine is lower than synthetic urine, mainly due to the natural difference of people and flush water dilution.

Rejection 2.Performance of FO in urine concentration 2.4.pH adjustment to promote the rejection for nitrogen 100,0% 90,0% Real Urine Synthetic Urine 80,0% 70,0% 60,0% 50,0% 40,0% 5 6 7 8 9 ph The highest rejection is achieved at ph=7. When ph=7, ammonia mainly exists as NH 4+, the combination of screening and Donnan effect has the best results. The permeability of the membrane is not influenced. When ph is lower, the permeability of the membrane increases thus allowing more ammonia molecules to get through. The durability of the membrane will be affected. When ph is higher, ammonia exists as NH 3, the Donnan effect will decrease.

3. Pilot-scale sanitation system

3. Pilot-scale sanitation system

3. Pilot-scale sanitation system Anaerobic digester Greywater treatment Urine storage Control panel Draw solution Vacuum station Membrane system Reclaimed water Greywater storage

3. Pilot-scale sanitation system Solar panel Air flush urinal Urine diversion vacuum toilet Flat sheet FO membrane module Fertilizer Anaerobic digester

3. Pilot-scale sanitation system Indicator Target value Results Cost <0.3 CNY/(capita d) 0.22 CNY/(capita d) Energy consumption <3.5 kwh/d 2.4 kwh/d Water consumption Urine <0.1 L/ flush Urine 0.1 L/ flush Feces <1.0 L/ flush Feces 1.0 L/ flush Fertilizer efficiency (N+P2O5+K2O, g/l) Hygienic indexes >38.4 g/l 11.9 g/l Egg death rate above 95% and a value fecal Escherichia Coli number less than 10-2 Egg death rate >99% fecal Escherichia Coli number 10-4 The urine can be concentrated for 2-3 times, and further concentration takes too long and energy consumption will rise. The low concentration of nutrients in real urine leads to low efficiency of the liquid fertilizer. The reclaimed water meets the standards for reuse, but the RO system cost too much energy.

4.Conclusions The application of FO in urine concentration is a promising solution for the pollution prevention and nutrients recovery. The improvement in water flux and rejection of the FO membrane is essential for the application. The synthetic urine can be very different from the practical situation, the design of the FO process and module should take it into consideration. The FO application is more feasible in places where high osmotic solution exists and has no need for recovery, such as coastal areas.

Thanks!