Luciferase Assay Kit INSTRUCTION MANUAL. Catalog # Revision B.0. For Research Use Only. Not for use in diagnostic procedures.

Similar documents
SideStep Lysis and Stabilization Buffer

Lambda DNA Purification Kit

DNA Extraction Kit INSTRUCTION MANUAL. Catalog # Revision B. For In Vitro Use Only

Quantos Cell Proliferation Assay Kit

DNA Extraction Kit INSTRUCTION MANUAL. Catalog # Revision A. For In Vitro Use Only

StrataPrep Plasmid Miniprep Kit

StrataPrep PCR Purification Kit

psg5 Vector INSTRUCTION MANUAL Catalog # Revision A For In Vitro Use Only

Absolutely RNA Microprep Kit

DNA Purification for Case Transgene Pronuclear Injection Updated 2/26/08 RM

SideStep mrna Enrichment Kit

ab65313 ADP/ATP Ratio Assay kit (Bioluminescent)

ab83355 ATP Assay Kit (Colorimetric/ Fluorometric)

Mitochondrial Membrane Potential Detection Kit

ab Beta Galactosidase Detection Kit (Fluorometric) Instructions for Use For monitoring β-galactosidase activity in cells.

Absolutely RNA 96 Microprep Kit

Tech support: Luciferase Assay System. Protocol. LightSwitch Transfec tion Optimization Kit. Genome In. Function Out.

pbluescript II RI Predigested Vector

TECHNICAL MANUAL. NAD/NADH-Glo Assay. Instructions for Use of Products G9071 and G9072. Revised 8/17 TM399

AdEasy Virus Purification Kits and 5 100

Stratagene QPCR Mouse Reference Total RNA

ToxiLight bioassay kit

Absolutely RNA Nanoprep Kit

Luciferase Assay System

ab65354 Superoxide Dismutase Activity Assay kit (Colorimetric)

Rapid GST Inclusion Body Solubilization and Renaturation Kit

ADP/ATP Ratio Assay Kit (Bioluminescent)

High Sensitivity Luminescence Reporter Gene Assay System

CAT Enzyme Assay System INSTRUCTIONS FOR USE OF PRODUCT E1000.

TECHNICAL MANUAL. NADP/NADPH-Glo Assay. Instructions for Use of Products G9081 and G9082. Revised 8/17 TM400

CalPhos Mammalian Transfection Kit User Manual

Stratagene QPCR Human Reference Total RNA

ab Luminescent ATP Detection Assay Kit

Generation Capture Column Handbook

Protocol. High-throughput Transfection Protocol for GoClone Reporter Assays. Tech support: Luciferase Assay System

Glucose-6-Phosphate Dehydrogenase (G6PDH) Activity Assay Kit

Brilliant II SYBR Green QPCR Master Mix

Tissue & Cell Genomic DNA Purification Kit. Cat. #:DP021/ DP Size:50/150 reactions Store at RT For research use only

Prime-It II Random Primer Labeling Kit

96-well Checkpoint Kinase Activity Assay Kit

IDTox Lactate Dehydrogenase (LDH) Enzyme Cytotoxicity Kit For Cell Culture Supernatant Samples

ab Histone Extraction Kit

ab Factor IXa Activity Assay Kit (Fluorometric)

ab Glutamine Assay Kit (Colorimetric)

MATERIAL DATA SHEET. NOTE: Kit contains reagents sufficient for 10 x 30 μl reactions and 5 Western Blots (minigel. Reagents Provided in Kit

MATERIAL DATA SHEET. Reagents Provided in Kit

GUS Assays. 1. Label all tubes. Prepare solutions and have ready at hand.

mirna 1st-Strand cdna Synthesis Kit

SPEEDTOOLS DNA EXTRACTION KIT

RayBio Human, Mouse and Rat Phospho-STAT3 (Tyr705) ELISA Kit

UltraClean Endotoxin-Free Mini Plasmid Prep Kit

FLAG Western Detection Kit

Total NAD and NADH Assay Kit (Colorimetric)

IgG TrueBlot Protocol for Mouse, Rabbit or Goatderived Antibodies - For Research Use Only

DNA 5 End-Labeling System INSTRUCTIONS FOR USE OF PRODUCT U2010.

RayBio Human, Mouse and Rat Phospho-STAT3 (Tyr705) and Total STAT3 ELISA Kit

Glucose 6 Phosphate Dehydrogenase Assay Kit (Colorimetric)

ab65354 Superoxide Dismutase Activity Assay kit (Colorimetric)

NADP + /NADPH Assay Kit (Colorimetric)

Rapid GST Inclusion Body Solubilization and Renaturation Kit

ab NAD/NADH Assay Kit (Fluorometric)

Instructions. Fuse-It-siRNA. Shipping and Storage. Overview. Kit Contents. Specifications. Note: Important Guidelines

APOB (Human) ELISA Kit

Brilliant SYBR Green QPCR Master Mix

ab Factor Xa Inhibitor Screening Assay Kit (Fluorometric)

ab Histone Extraction Kit Rapid / Ultra-pure

MEK1/2 (MAPK Kinase) Activity Assay Kit

Illuminator Chemiluminescent Detection System

Electrocomp GeneHogs E. coli One Shot Electrocomp GeneHogs E. coli

RayBio Human NF-κB p65 Transcription Factor Activity Assay Kit

ab Complex I Enzyme Activity Microplate Assay Kit

Lambda DASH II Library

ab Plasmin Inhibitor Screening Assay Kit (Fluorometric)

HighPrep Blood & Tissue DNA Kit

ab Histone H3 (tri-methyl K27) Quantification Kit (Fluorometric)

LDH Cytotoxicity Assay Kit. Item No

Human TACI (TNFRSF13B) ELISA Kit

Laboratory protocol for manual purification of DNA from whole sample

ProductInformation. Genomic DNA Isolation Kit. Product No. GDI-3 Technical Bulletin No. MB-275 May 2000 TECHNICAL BULLETIN

GST Fusion Protein Purification Kit

RayBio Caspase Colorimetric Substrate Set II Plus

LDH-Cytox Assay Kit. A Colorimetric Cytotoxicity Measuring Kit. Cat. No LDH-Cytox Assay Kit can be used to measure cytotoxicity in vitro

E.Z.N.A. Stool DNA Kit. D preps D preps D preps

+ M III. IMAP Screening Express Kit Product #8073 Quantity: 8000, 20 µl reactions (80 µl final volumes) Low FP. M III High FP.

Lambda CE6 Induction Kit

Please read all the information in booklet before using the unit

ab65331 L- Lactate Assay kit (Colorimetric)

ElectroTen-Blue Electroporation Competent Cells

ab Plant Chromatin Extraction Kit

ab Porcine VEGF-A ELISA Kit

DNA Laddering Assay Kit

In-Cell Western Kits I and II

For the sensitive and accurate measurement of adenylate cyclase activity in cell extracts, tissue extracts and biological fluids.

RayBio Phospho- Stat 3 (Tyr705) ELISA Kit

Human IgM Ready-SET-Go!

XactEdit Cas9 Nuclease with NLS User Manual

Phosphate buffered saline (PBS) for washing the cells TE buffer (nuclease-free) ph 7.5 for resuspending the SingleShot RNA control template

ab Glutamate Assay Kit (Fluorometric)

RPM. Rapid Pure Miniprep Kit preps preps preps preps preps

ab Histone H4 Acetylation Assay Kit

Transcription:

Luciferase Assay Kit INSTRUCTION MANUAL Catalog #219020 Revision B.0 For Research Use Only. Not for use in diagnostic procedures. 219020-12

LIMITED PRODUCT WARRANTY This warranty limits our liability to replacement of this product. No other warranties of any kind, express or implied, including without limitation, implied warranties of merchantability or fitness for a particular purpose, are provided by Agilent. Agilent shall have no liability for any direct, indirect, consequential, or incidental damages arising out of the use, the results of use, or the inability to use this product. ORDERING INFORMATION AND TECHNICAL SERVICES United States and Canada Agilent Technologies Stratagene Products Division 11011 North Torrey Pines Road La Jolla, CA 92037 Telephone (858) 373-6300 Order Toll Free (800) 424-5444 Technical Services (800) 894-1304 Internet techservices@agilent.com World Wide Web www.stratagene.com Europe Location Telephone Fax Technical Services Austria 0800 292 499 0800 292 496 0800 292 498 Belgium 00800 7000 7000 00800 7001 7001 00800 7400 7400 0800 15775 0800 15740 0800 15720 France 00800 7000 7000 00800 7001 7001 00800 7400 7400 0800 919 288 0800 919 287 0800 919 289 Germany 00800 7000 7000 00800 7001 7001 00800 7400 7400 0800 182 8232 0800 182 8231 0800 182 8234 Netherlands 00800 7000 7000 00800 7001 7001 00800 7400 7400 0800 023 0446 +31 (0)20 312 5700 0800 023 0448 Switzerland 00800 7000 7000 00800 7001 7001 00800 7400 7400 0800 563 080 0800 563 082 0800 563 081 United Kingdom 00800 7000 7000 00800 7001 7001 00800 7400 7400 All Other Countries 0800 917 3282 0800 917 3283 0800 917 3281 Please contact your local distributor. A complete list of distributors is available at www.stratagene.com.

Luciferase Assay Kit Contents Materials Provided... 1 Storage Conditions... 1 Additional Materials Required... 1 Introduction... 2 Extracting Luciferase from Tissue Culture Cells... 3 Performing the Luciferase Activity Assay... 4 Active Lysis Protocol for Extracting Luciferase from Tissue Culture Cells... 5 Troubleshooting... 6 Preparation of Reagents... 6 References... 6 Endnotes... 6 MSDS Information... 6 Quick-Reference Protocol... 8

Luciferase Assay Kit MATERIALS PROVIDED Materials Provided a Quantity Luciferase assay buffer (1 ) 10 ml Luciferase assay substrate (lyophilized) 1 vial Luciferase cell culture lysis buffer (5 ) 30 ml a The Luciferase assay kit contains sufficient reagents for 100 assays performed in 35-mm tissue culture plates. STORAGE CONDITIONS All Components: Store all Luciferase assay kit components at 20 C. Luciferase Substrate: Store the Luciferase substrate at 20 C in the dark. Following reconstitution of the Luciferase substrate, the reconstituted reagent may be stored at 70 C for one year or at 20 C for one month and should be stored in the dark. Avoid subjecting the reconstituted Luciferase substrate to multiple freeze-thaw cycles by dispensing the reagent into working aliquots. ADDITIONAL MATERIALS REQUIRED Luminometer Revision B.0 Agilent Technologies, Inc. 2015. Luciferase Assay Kit 1

INTRODUCTION The Luciferase Assay Kit* provides a rapid, sensitive, and quantitative measurement of the activity of the reporter enzyme American firefly (Photinus pyralis) luciferase in cultured mammalian cells. The kit is designed for use with the Stratagene PathDetect in vivo signal transduction pathway reporting systems and other systems that use firefly luciferase as a reporter enzyme in mammalian cells. The luciferase assay is highly sensitive as few as ~1 10 20 moles of luciferase (1 10 5 luciferase molecules) are detected with a luminometer under optimal conditions. 1 4 Background activity is low because mammalian cells do not contain endogenous luciferase. Luciferase catalyzes the following chemiluminescent oxidation reduction reaction: luciferase substrate (luciferin) + ATP + O 2 oxyluciferin + light (560 nm) + AMP + PP i + CO 2 The Luciferase assay kit contains a cell lysis buffer, the luciferase substrate, and an assay buffer. The cell lysis buffer allows efficient extraction of luciferase from many types of cultured cells without the time-consuming task of scraping the cells from the tissue culture plate. The luciferase assay is performed by adding the luciferase substrate dissolved in assay buffer to the cell lysate. Luciferase in the cell lysate catalyzes the chemiluminescent reaction, which emits light that remains nearly constant for several minutes (see Figure 1). The emitted light is readily measurable with a luminometer. The luciferase activity emitted light relationship is linear over at least eight orders of magnitude of relative light units (RLU). Light Emission/Second (RLU) 90000 80000 70000 60000 50000 40000 30000 20000 10000 0 0 30 60 90 120 150 Time (seconds) Figure 1 Light emitted by the luciferase-catalyzed chemiluminescent reaction, in relative light units (RLU), measured 8 seconds after the addition of 0.1 ng of luciferase and every 30 seconds thereafter, with integration periods of 1 second. * Manufactured for Stratagene Products Division by Promega Corporation. 2 Luciferase Assay Kit

EXTRACTING LUCIFERASE FROM TISSUE CULTURE CELLS s The cell lysis buffer supplied with the kit is designed to extract luciferase from mammalian tissue culture cells that are transfected with the luciferase reporter gene. The inclusion of 1% Triton X-100 in the cell lysis buffer allows the direct lysis of many types of tissue culture cells, such as HeLa cells and fibroblasts. Extraction of luciferase from tissue, yeast, or bacteria may require a different lysis buffer and a different extraction protocol. Little or no luciferase activity in all of the samples may indicate that the following passive lysis method has failed to lyse the cells. If the cells are not lysed by the passive method, use the active cell lysis method in Active Lysis Protocol for Extracting Luciferase from Tissue Culture Cells. The quantities of the reagents given in this protocol are optimized for a 35-mm tissue culture plate having ~9.4 cm 2 of surface area in each well. The volume of the cell lysis buffer may be adjusted for tissue culture plates of other sizes. 1. Being careful not to dislodge any of the cells, remove the media from the tissue culture plate wells and wash the cells twice with 1 PBS (see Preparation of Reagents). 2. Using a Pasteur pipet, remove as much PBS as possible from each well. 3. Make 1 cell lysis buffer by adding 4 milliliters of dh 2 O per milliliter of the 5 cell lysis buffer. Equilibrate the lysis buffer to room temperature before use. 4. Cover the cells by adding approximately 200 500 μl of 1 cell lysis buffer to each well. 5. Incubate the plate at room temperature for 15 minutes, swirling occasionally. 6. Scrape the cells and buffer from each well into separate microcentrifuge tubes. Place the tubes on ice. 7. Vortex the microcentrifuge tubes for 10 15 seconds. Spin the tubes in a microcentrifuge at 12,000 g for 15 seconds at room temperature or 2 minutes at 4 C. 8. Transfer the supernatant from each tube to a new microcentrifuge tube. 9. Immediately assay the supernatant for luciferase activity according to the protocol in Performing the Luciferase Activity Assay or store the supernatant at 80 C for later use. Each freeze thaw cycle results in a significant loss of luciferase activity (as much as 50%). Luciferase Assay Kit 3

PERFORMING THE LUCIFERASE ACTIVITY ASSAY The following protocol is based on a single-tube luminometer. Luminometers capable of assaying multi-well plates (e.g., 96-well plates) and sophisticated computer software to process large numbers of samples are also commercially available. Although both scintillation counters 5 and photographic film can be used to detect the light emission, they are not as sensitive. 1. Prepare the luciferase substrate assay buffer mixture by adding all of the assay buffer (10 ml) to the vial containing the lyophilized luciferase substrate and mixing well. 2. Divide the luciferase substrate assay buffer mixture into aliquots of an appropriate size to avoid multiple freeze thaw cycles. The luciferase substrate assay buffer mixture is best if used within one month when stored at 20 C or within one year when stored at 70 C. Avoid unnecessary freeze thaw cycles. Protect the luciferase substrate assay buffer mixture from light. 3. Allow the luciferase substrate assay buffer mixture to reach room temperature. Allow the supernatant from step 9 in Extracting Luciferase from Tissue Culture Cells to reach room temperature. 4. Add 100 μl of the luciferase substrate assay buffer mixture to a polystyrene tube that fits in the luminometer (e.g., a 5-ml BD Falcon polystyrene round bottom tube). 5. Add 5 20 μl of supernatant to the tube, mix gently, and immediately put the tube into the luminometer. 6. Begin measuring the light produced from the reaction ~8 seconds after adding the supernatant using an integration time of 5 30 seconds. Use the same delay time for all of the samples. Adjust the integration time if the luciferase activity in the supernatant is very low or very high (see Troubleshooting). 4 Luciferase Assay Kit

ACTIVE LYSIS PROTOCOL FOR EXTRACTING LUCIFERASE FROM TISSUE CULTURE CELLS Little or no luciferase activity in all of the samples may indicate that the passive lysis method in Extracting Luciferase from Tissue Culture Cells has failed to lyse the cells. If the cells are not lysed by the passive method, use the following active cell lysis protocol: 1. Being careful not to dislodge any of the cells, remove the media from the tissue culture plate and wash the cells twice with 1 PBS. 2. Using a Pasteur pipet, remove as much PBS as possible from the plate. 3. Make 1 cell lysis buffer by adding 4 milliliters of dh 2 O per milliliter of the 5 cell lysis buffer. Equilibrate the lysis buffer to room temperature before use. 4. Add 200 500 μl of 1 cell lysis buffer to each well. 5. Scrape the entire surface of the tissue culture plate. 6. Using a pipet, transfer the cells to microcentrifuge tubes and place the tubes on ice. 7. Use either of the following methods to lyse the cells: a. Briefly sonicate the cells with a microtip at the lowest energyoutput level. b. Freeze the cells at 80 C for 20 minutes, thaw the cells in a 37 C water bath, and vortex the tube for 10 15 seconds. 8. Spin the tubes in a microcentrifuge at top speed for 2 minutes. 9. Transfer the supernatant in each tube to a new microcentrifuge tube. 10. Immediately, assay the supernatant for luciferase activity according to the protocol in Performing the Luciferase Activity Assay or store the supernatant at 80 C for later use. Each freeze thaw cycle results in a significant loss of luciferase activity (as much as 50%). Luciferase Assay Kit 5

TROUBLESHOOTING Observation Low or no luciferase activity in all samples The luciferase activity is too low in some samples The luciferase activity levels in many samples are very high (>1 10 8 RLU) and the activity levels differ little between samples Suggestion(s) Optimize the transfection procedure with a control reporter plasmid. Little or no luciferase activity in all of the samples may indicate that the passive lysis method in Extracting Luciferase from Tissue Culture Cells has failed to lyse the cells. Instead, use the cell lysis method in Active Lysis Protocol for Extracting Luciferase from Tissue Culture Cells. Increase the luciferase concentration by using less cell lysis buffer when lysing the cells. Use a longer integration time to measure the light produced by the chemiluminescent reaction. Decrease the luciferase concentration by using more cell lysis buffer when lysing the cells or by diluting the supernatant with cell lysis buffer. Use a shorter integration time to measure the light produced by the chemiluminescent reaction. PREPARATION OF REAGENTS Cell Lysis Buffer (1 ) 25 mm Tris-phosphate (ph 7.8) 2 mm DTT 2 mm 1,2-diaminocyclohexane- N,N,N,N -tetraacetic acid 10% glycerol 1% Triton X-100 1 PBS 137 mm NaCl 2.6 mm KCl 10 mm Na 2 HPO 4 1.8 mm KH 2 PO 4 Adjust the ph to 7.4 with HCl REFERENCES 1. Bronstein, I., Fortin, J., Stanley, P. E., Stewart, G. S. and Kricka, L. J. (1994) Anal Biochem 219(2):169-81. 2. Kain, S. and Ganguly, S. (1995). In Current Protocols in Molecular Biology, F. M. Ausubel, R. Brent, R. E. Kingston, D. D. Moore, J. G. Seidman et al. (Eds.), pp. 9.6.1-9.6.12. John Wiley and Sons, New York. 3. de Wet, J. R., Wood, K. V., DeLuca, M., Helinski, D. R. and Subramani, S. (1987) Mol Cell Biol 7(2):725-37. 4. Wood, K. V. (1995) Curr Opin Biotechnol 6(1):50-8. 5. Nguyen, V. T., Morange, M. and Bensaude, O. (1988) Anal Biochem 171(2):404-8. ENDNOTES Triton is a registered trademark of Union Carbide Chemicals and Plastics Co., Inc. MSDS INFORMATION The Material Safety Data Sheet (MSDS) information for Stratagene products is provided on the web at http://www.stratagene.com/msds/. Simply enter the catalog number to retrieve any associated MSDS s in a print-ready format. MSDS documents are not included with product shipments. 6 Luciferase Assay Kit

Luciferase Assay Kit Catalog #219020 QUICK-REFERENCE PROTOCOL Extracting Luciferase from Tissue Culture Cells The quantities of the reagents given in this protocol are optimized for a 35-mm tissue culture plate having ~9.4 cm 2 of surface area. Remove the media from the tissue culture plate and wash the cells twice with 1 PBS, removing as much PBS as possible. Make 1 cell lysis buffer by adding 4 ml of dh 2 O per ml of the 5 cell lysis buffer. Equilibrate the lysis buffer to room temperature. Cover the cells by adding approximately 200 500 μl of 1 cell lysis buffer to each well. Incubate the plate at room temperature for 15 minutes, swirling occasionally. Scrape the cells and buffer from each well into separate microcentrifuge tubes. Place the tubes on ice. Vortex the microcentrifuge tubes for 10 15 seconds. Spin the tubes in a microcentrifuge at 12,000 g for 15 seconds at room temperature or 2 minutes at 4 C. Transfer the supernatant from each tube to a new microcentrifuge tube. Immediately assay the supernatant for luciferase activity or store the supernatant at 80 C for later use. Performing the Luciferase Activity Assay The following protocol is based on a single-tube luminometer. Prepare the luciferase substrate assay buffer mixture by adding all of the assay buffer (10 ml) to the vial containing the lyophilized luciferase substrate and mixing well. Allow the luciferase substrate assay buffer mixture to reach room temperature. Allow the cell supernatant to reach room temperature. Add 100 μl of the luciferase substrate assay buffer mixture to a polystyrene tube. Add 5 20 μl of supernatant to the tube, mix gently, and immediately put the tube into the luminometer. Begin measuring the light produced from the reaction ~8 seconds after adding the supernatant using an integration time of 5 30 seconds. Use the same delay time for all of the samples. Luciferase Assay Kit 8