Mathematical Applications in Science and Mechanics

Similar documents
Hygrothermal properties applied in numerical simulation: Interstitial condensation analysis Received (in revised form): 24th July 2009

Application of Waste Ceramics as Active Pozzolana in Concrete Production

DURABILITY PROPERTIES OF SELF COMPACTING CONCRETE PRODUCED USING BLAST FURNACE SLAG

PH-CALCULATION Dynamic simulation with WUFI

Energy consumption and thermal comfort in a passive house built in Romania

Hygrothermal Calculations applied to water-repellent surfaces - Validation and Application -

Proceedings Cold Climate HVAC Sisimiut, Greenland, March 2009

Buildings XI Conference Workshop 2: Thermal Mass IV Assessing Thermal and Moisture Control Benefits of PCM Components by Hygrothermal Simulation

Design of Mineral Fibre Durability Test Based on Hygrothermal Loads in Flat Roofs.

IMPACT OF COLUMNS AND BEAMS ON THE THERMAL RESISTANCE OF THE BUILDING ENVELOPE

CEN/TC 89 - Thermal performance of buildings and building components

DETERMINATION OF THERMAL TECHNICAL PROPERTIES OF ORGANIC THERMAL INSULATING MATERIALS BUILT-IN TO HISTORICAL BUILDINGS

On the hygrothermal performance of straw bale wall elements in Belgium

The Rijksmuseum Amsterdam - Hygrothermal analysis and dimensioning of thermal insulation

Moisture convection performance on the joint of external wall and attic floor - laboratory tests and two-dimensional simulation model validation

Thermal Performance Degradation of Foam Insulation in Inverted Roofs Due to Moisture Accumulation

Lime-Pozzolan Plasters with Enhanced Thermal Capacity Z. Pavlík, A. Trník, M. Pavlíková, M. Keppert, R. Černý

Numerical Simulation of a Building Envelope with High Performance Materials

Flexible Vapor Control Solves Moisture Problems of Building Assemblies - Smart Retarder to Replace the Conventional PE-Film

Observation of Liquid-filled Window without Presence of Liquid in Test Chamber

Thermal Performance of Retrofitted Envelopes with Internal Insulation: A Comparative Analysis

Is the moisture buffer value a reliable material property to characterise the hygric buffering capacities of building materials?

Experimental Assessment of Hygrothermal Performance of Wood Frame Wall System in Suzhou's Lake Tai Climate Zone

Hygrothermal modelling of a sustainable retrofit taking into account the urban microclimate. Case study of the medieval city center of Cahors (France)

NUMERICAL MODEL FOR PREDICTION OF CRACKS IN CONCRETE STRUCTURES

DESIGN AND USE OF RADIANT BARRIERS AS THERMAL INSULATION FOR HIGH INERTIA HOUSES IN TROPICAL CONDITIONS A CASE STUDY

External Environment and Indoor Microclimate

Energy Efficient Buildings in Germany An Introduction

Available online at ScienceDirect. Procedia Engineering 151 (2016 )

A Comparative Study of the Thermal Comfort of Different Building Materials in Sana a

A NEW MODEL FOR PREDICTION AND ITS APPLICATION IN PRACTICE

ENVIRONMENTAL ANALYSIS OF BUILDING MATERIALS OF HOMES IN SLOVAK REPUBLIC A CASE STUDY

Development of an improved model for mould growth: Modelling

INVESTIGATIONS OF GYPSUM BOARDS WITH REGARD TO THE MOISTURE-BUFFERING-EFFECTS

THE HYGROTHERMAL BEHAVIOUR OF ROOMS: COMBINING THERMAL BUILDING SIMULATION AND HYGROTHERMAL ENVELOPE CALCULATION

1. Introduction. Carl-Magnus Capener, Ph.D. 1 Stephen Burke, Ph.D. 2 Simon Le Roux, Architect 3 Stephan Ott, Architect 4

EXPERIMENTAL INVESTIGATION OF ROCKWOOL INSULATION HYGROTHERMAL PROPERTIES RELATED TO MATERIAL STRUCTURE

Apartment building Sodastraße 40 in Ludwigshafen, DE

Accuracy of simplified indoor humidity simulation

BUILDING DESIGN AND THERMAL INERTIA: WHEN, WHY, WHERE

Hygrothermal Evaluation of Icynene Spray Foam Insulation Installed Between Roof Rafters on Pitched Roofs

EXTERNAL THERMAL INSULATION FOR WARM CLIMATE ZONES

NUMERICAL SIMULATION OF CAR COCKPIT HEATING DURING WINTER 1

STEADY STATE AND DYNAMIC THERMOPHYSICAL PARAMETERS OF TRANSPARENT BUILDING COMPONENTS

Numerical Analysis of Heat Conduction and Phase. Transformation in Laser Transformation. Hardening: Influences of Heating Duration and

Evaluation of the hygrothermal performance of a concrete wall construction with Icynene open cell insulation

Indoor climate design for a monumental building with periodic high indoor moisture loads.

Improving the hygrothermal properties of clay plasters

THERMAL MASS IMPACT ON ENERGY PERFORMANCE OF A LOW, MEDIUM, AND HEAVY MASS BUILDING IN BELGRADE

European Cooperation in the field of Scientific and Technical Research. Building Integration of Solar Thermal Systems TU1205 BISTS

ANALYSIS OF THE ENERGY PERFORMANCE OF EARTH-SHELTERED HOUSES WITH SOUTHERN ELEVATION EXPOSED. Maja Staniec 1, Henryk Nowak 1

Smart Vapor Retarders

Application of electrical impedance spectrometry for measurements of humidity distribution in aerated concrete masonry constructions

Abstract. Nomenclature. A Porosity function for momentum equations L Latent heat of melting (J/Kg) c Specific heat (J/kg-K) s Liquid fraction

THERMAL MASS IMPACT ON ENERGY PERFORMANCE OF A LOW, MEDIUM AND HEAVY MASS BUILDING IN BELGRADE

COOLING TOWER DESIGN FOR CENTRAL GENERATORS OF CUET, BANGLADESH. Mohammad Sharif Khan, Golam Mainuddin, Abu Sadat Mohammad Sayem, Nadeem Nafis

Experiment in real conditions: mechanical properties of gypsum block determined using non-destructive and destructive methods

Building envelope and sealing systems interior and exterior

PREFABRICATED LOAD BEARING WALL PANELS EFFECTIVE TECHNOLOGIES FOR EARTH STRUCTURES

Biological Defacement of External Thermal Insulation Composite Systems

DEVELOMENT AND EVALUATION OF ENVIRONMENTALLY FRIENDLY FAÇADE ELEMENTS FOR DEEP RETROFITTING OF BUILDINGS

Moisture transport across interfaces between autoclaved aerated concrete and mortar. Qiu, X.; Haghighat, F.; Kumaran, M.K.

Moisture and temperature conditions in cold lofts and risk of mould growth

Computational and the real energy performance of a single-family residential building in Poland an attempt to compare: a case study

An Evaluation of the Total Energy Consumption of Educational Buildings: Prototype Case Studies in Saudi Arabia

Hygroscopic Materials versus Mechanical Ventilation

THERMAL PERFORMANCE USING RADIANT BARRIER AND PHASE CHANGE MATERIAL IN ROOFS

Impact of Sustainable Cool Roof Technology on Building Energy Consumption

Dynamical interactions between heat and mass flows in Lime-Hemp Concrete

Adapted vapour control for durable building enclosures

See how to use WUFI in conjunction with ASHRAE s New Standard 160, Design Criteria for Moisture Control in Buildings.

OPERATION AND CONTROL OF THERMALLY ACTIVATED SLAB HEATING AND COOLING SYSTEMS

EXPRIMENTAL INVESTIGATION OF ROCKWOOL INSULATION HYGROTHERMAL PROPERTIES RELATED TO MATERIAL STRUCTURE

Thermal Rehabilitation of Existing Building Enclosures by Using VIP (Vacuum Insulation Panel) Sandwich and Timber Based Panels

Bruck an der Mur. Project summary. Energy concept: Background for the renovation reasons

Optimisation of an HVAC system for energy saving and thermal comfort in a university classroom

How Many Times Can You Repaint the Exterior of Your Building? Kevin Brown KTA-Tator, Inc.

APT building on Makartstrase, Linz AT

5th Pan American Conference for NDT 2-6 October 2011, Cancun, Mexico

CHAPTER 3. BUILDING THERMAL LOAD ESTIMATION

Current State of Knowledge on the Hygrothermal Behaviour of Bio-based Materials

Thermal Comfort in Architecture

Environmental friendly concrete production using municipal solid waste incineration materials

MOISTURE ACCUMULATION IN WALLS: COMPARISON OF FIELD AND COMPUTER-PREDICTED DATA

ENERGY SAVING IN BUILDING USING PCM IN WINDOWS

A NOVEL TECHNIQUE FOR EXTRACTION OF GEOTHERMAL ENERGY FROM ABANDONED OIL WELLS

Aalborg Universitet. CLIMA proceedings of the 12th REHVA World Congress Heiselberg, Per Kvols. Publication date: 2016

Shading effects on the winter thermal performance of the Trombe wall air gap: An experimental study in Dalian

See how to use WUFI in conjunction with ASHRAE s New Standard 160, Design Criteria for Moisture Control in Buildings.

Integrated Hygrothermal Analysis of Ecological Buildings

Technical Data Sheet StoLevell Duo plus

NOTES AND CORRESPONDENCE. Toward a Robust Phenomenological Expression of Evaporation Efficiency for Unsaturated Soil Surfaces

THERMAL PERFORMANCE CALCULATION. Analysis undertaken and report prepared on behalf of XXXXXXX for. XXXXXXX

Environmentally-friendly insulation systems made from natural wood fibres. We care about. Innova Wood / ITD Conference

Modelling a temperature regime of a railway track structure and its comparison with the results of experimental measurements

Breathability of building elements

EPSRC Centre for Doctoral Training in Industrially Focused Mathematical Modelling

RESTORATION MEASURES THAT SAVE ENERGY. Insulating Without Losing Face

Thermal Simulation for a Room with Solid and One-way Ribbed Slab Using FEM

Data Sheet 3611 Englisch

Transcription:

Energy Balance of AAC Building Envelopes with Mineral-Wool Thermal Insulation: Effect of Moisture Content VÁCLAV KOČÍ, ROBERT ČERNÝ Department of Materials Engineering and Chemistry, Faculty of Civil Engineering, Czech Technical University in Prague, Thákurova 7/277, 166 29 Prague 6 CZECH REPUBLIC vaclav.koci@fsv.cvut.cz http://tpm.fsv.cvut.cz Abstract: - Computational analysis of hygrothermal performance of several building envelopes based on autoclaved aerated concrete (AAC) is presented in the paper. Based on the knowledge of thermal and hygric conditions inside the building envelope, the energy balance calculations assuming the effect of moisture content are accomplished. All the material parameters necessary for the calculations are measured within the experimental analysis preceding the computations. As boundary conditions, climatic data in form of reference year are used. The obtained results are compared and conclusions are drawn. Key-Words: AAC, building envelope, hygrothermal performance, heat and moisture transport, energy balance, mineral wool 1 Introduction Calculations of energy balance of building envelopes or their parts can be performed in many ways. The accuracy of obtained results depends on quality and quantity of input parameters and methods of their processing. For instance standard procedure presented in Czech thermal standard [1-2] should provide simple calculation in order to be easily used by designers. However, the simplifications have side effect in form of inaccuracies, because only simple Glaser s model is used and thus whole liquid moisture intake and transport is neglected. It is generally known that thermal conductivity is highly dependent on moisture content [3], especially when thermal insulations are under consideration [4-5]. Although this standard obtains design values of thermal conductivity assuming certain moisture content, under real conditions this amount can be much higher as well as subsequent heat losses. It is important to perform the calculations precisely in order to get as accurate results as possible. That means that a complete set of thermal and hygric material parameters should be used, as well as realistic boundary conditions in form of climatic data. Besides mechanical parameters of building materials, also their thermal insulating properties play currently very important role. The reason is very simple, because energy prices are very high and exhaustibility of nonrenewable energy resources threats the society. That explains present efforts to achieve energy savings in building industry, which is one of the largest energy consumers in EU [6]. It can be achieved using modern building materials with better thermal insulating skills such as autoclaved aerated concrete (AAC). Combination of this material with common thermal insulations will create building envelopes with excellent thermal insulating capabilities and helps to reach required energy savings, because substantial share of energy is consumed by heating [7]. However, it is important to pay attention to their hygrothermal performance, so insulating materials have to be chosen wisely [8] and mineral wool seems to be the most appropriate solution. The main objective of this paper is to assess energy balance of AAC based building envelope provided from exterior and interior with several types of mineral wools according to the results of numerical simulation assuming presence and transport of liquid moisture under real climatic conditions. 2 Computational Analysis The computational analysis was performed using computer code HEMOT [9-1], which was developed at Department of Materials Engineering and Chemistry, Faculty of Civil Engineering, Czech Technical University in Prague. This code is an extension of program package SIFEL [11] and allows a user to utilize its user-friendly interface to define all the necessary input parameters, such as mathematical model, scheme of analyzed ISBN: 978-96-474-35-6 158

construction detail, initial and boundary conditions or time specification of calculations. Within the framework of this paper, Künzel s mathematical model for coupled heat and moisture transport [12] was used. This model was successfully verified [13] and used in the previous researches [14-15]. 2.1 Scheme of construction details As load bearing material, AAC P2-35 in a thickness of 45 mm was assumed. This wall was provided with external and internal thermal consisting of 1 mm thick layer of hydrophobic/hydrophilic mineral wool connected using 1 mm thick adhesive layer. As external and internal finishes, MVR Uni plaster (1 mm) was used. This plaster was developed especially for AAC-based constructions. As reference building envelope, only AAC wall with MVR Uni plaster was defined. All the variations of building envelope are captured in Fig. 1. 2-3, where following symbols are used: ρ bulk density [kg/m 3 ], ψ porosity [%], c specific heat capacity [J/(kg K)], µ water vapor diffusion resistance factor [-], λ dry thermal conductivity in dry state, λ sat thermal conductivity in water saturated state, κ app apparent moisture diffusivity [m 2 /s], w hyg hygroscopic moisture content [m 3 /m 3 ]. Table 1 Material parameters part I AAC P2-35 MVR Uni plaster Adhesive layer ρ [kg/m 3 ] 367 142 143 ψ [%] 81.6 44.4 42.6 c [J/(kg K)] 116-145 12-178 12 µ [-] 3.3-12 4.5-12.4 12.4 λ dry λ sat.83.443.481.746 1.38 2.22 κ app [m 2 /s] 2.48e-9 1.59e-9 1.7e-9 w hyg [m 3 /m 3 ].21.42.21 Table 2 Material parameters part II Hydrophobic mineral wool Hydrophilic mineral wool ρ [kg/m 3 ] 1 17 ψ [%] 96.6 92.9 c [J/(kg K)] 79 77 µ [-] 1.3-2.6 1.6-2.7 λ dry λ sat.36.41.766.694 κ app [m 2 /s] 4.73e-9 2.7e-5 w hyg [m 3 /m 3 ].21.539 Fig. 1: Scheme of analyzed building envelopes 2.2 Material parameters All the parameters of materials which are involved in analyzed building envelopes were measured in the laboratories of the Department of Materials Engineering and Chemistry, Faculty of Civil Engineering, Czech Technical University in Prague [16-19]. These parameters are summarized in Tables 2.3 Initial and boundary conditions Initial and boundary conditions should be as realistic as possible in order to achieve the most accurate results. For this reason, climatic data for Prague was used on exterior side of analyzed building envelope in the form of reference year. Reference climatic year contains averaged longterm hourly values of temperature, relative humidity, wind direction and velocity, rainfalls and several kinds of sun radiation. It was generated using METEONORM software [2]. On the interior ISBN: 978-96-474-35-6 159

side, constant temperature 21 C and relative humidity 55 % was used. These data are prescribed in Czech thermal standard CSN 73 54-3 Thermal protection of buildings Design value quantities [2]. 2.4 Methodology of energy balance calculations Energy balance of analyzed building envelopes was calculated on the basis of computational results. The results were obtained in form of hourly values of temperature and moisture content in any point of construction. In the first step, heat flux through the envelope was calculated according to, (1) where q is heat flux [W/m 2 ], λ(w) is thermal conductivity depending on moisture content, dt is temperature difference between two nodal values [K] and dx is distance of these nodes [m]. The nodes were chosen on interior side, because the simulations were not performed in steady state and values of temperature and moisture content near the interior side of building envelope were much stable because of constant boundary conditions on this side. After hourly values of heat flux were calculated, integration of time function of heat flux (Eq. 2) provided the energy balance per one square meter of envelope and chosen time period, one year for instance, d, (2) where Q is energy balance per certain time period [kwh/m 2 ], q(t) is time function of heat flux [W/m 2 ] and t is time [h]. 3 Computational Results and Discussion All the results are related to the third year of computational simulation. Plus sign of heat flux denotes heat loss, minus sign denotes heat gain. In the presented figures and tables the following shortcuts are used: HFOBext - hydrophobic mineral wool applied on exterior side, HFOBint hydrophobic mineral wool applied on interior side, HFILext hydrophilic mineral wool applied on exterior side, HFILint hydrophilic mineral wool applied on interior side and REF reference building envelope without thermal insulating system. Comparison of time functions of heat fluxes of building envelopes with external insulation systems is shown in Fig. 2. Also time function of heat flux of reference building envelope without thermal insulation is included. Heat flux [W/m 2 ] 8 7 6 5 4 3 2 1-173 83 93 13 Time [day] REF HFOBext HFILext Fig. 2: Time function of heat flux external thermal It is obvious from Fig. 2 that the highest heat flux is obtained when thermal insulation is missing. Building envelope provided with hydrophilic mineral wool has not as good thermal insulating properties as building envelope with hydrophobic mineral wool, because the heat flux is much higher. Main reason of this fact is easy moisture acceptance of hydrophilic mineral wool and subsequent quick moisture transport (κ = 2.7e-5 m 2 /s) which leads to worsening of its thermal conductivity (see λ dry and λ sat in Table 2). Thanks to hydrophobic agents contained in hydrophobic mineral wool, this material is kept in relatively dry state all the time, which ensures preservation of its excellent thermal insulating capabilities. Annual and monthly energy balance of AACbased building envelopes provided from exterior with different types of mineral wool is shown in Fig. 3. While hydrophobic mineral wool improves monthly energy balance of AAC-based building envelope approximately by 26-39 %, hydrophilic mineral wool does not provide such good results. In warm summer months, July and August, energy balance of building envelope with hydrophilic mineral wool was even worse by 34 and 54 %, ISBN: 978-96-474-35-6 16

respectively, than reference envelope. It is caused by number of rainfalls characteristic for this period of year, which significantly decreases thermal insulating capability of hydrophilic mineral wool. Energy balance ]Wh/m 2 ] Fig. 3: Monthly energy balance external thermal Based on results presented in Fig. 3 one can realize that hydrophilic mineral wool in not suitable for application in exterior or it has to be carefully protected against moisture intake. Heat flux [W/m 2 ] 45 4 35 3 25 2 15 1 5 8 7 6 5 4 3 2 1 1 2 3 4 5 6 7 8 9 1 11 12 Month REF HFOBext HFILext -1 73 83 93 13 Time [day] REF HFOBint HFILint Fig. 4: Time function of heat flux internal thermal Protection against moisture is also effective, when internal thermal s are used. In Fig. 4, time functions of heat fluxes of building envelopes with this type of thermal insulation system are presented together with reference building envelope. Heat fluxes of both provided building envelopes are very similar, but hydrophobic mineral wool gives slightly better results. Similarly to the previous case, presence of hydrophobic agents plays a significant role here. Thermal performance of building envelope with hydrophilic mineral wool is much better in this case and leads to the improvement of energy balance approximately by 29 %. However, better energy balance is achieved again, when hydrophobic mineral wool is assumed (37 %). Complete monthly energy balance of building envelopes with internal thermal is shown in Fig. 5. Energy balance ]Wh/m 2 ] 45 4 35 3 25 2 15 1 5 1 2 3 4 5 6 7 8 9 1 11 12 Month REF HFOBint HFILint Fig. 5: Monthly energy balance internal thermal Comparison of annual energy balances of all investigated variations of building envelopes is shown in Fig. 6 and Table 3. According to the results, best energy balance is achieved when hydrophobic mineral wool is assumed and it does not matter whether on external or internal side of building envelope. Presence of hydrophobic agents protects mineral wool against liquid moisture intake, thus only water vapor, which does not have significant influence on thermal properties, is transported mainly. Slightly better energy balance is even achieved when internal thermal insulating system is assumed. It can be explained by combination of especially developed MVR Uni plaster with AAC, which was already confirmed before [21] and which effectively works together when exposed to weather conditions. ISBN: 978-96-474-35-6 161

HFOBext HFOBint HFILext HFILint REF 1 2 3 Annual energy balance [kwh/m 2 a] Fig. 6: Annual energy balances Table 3: Annual energy balances Annual energy % of balance [kwh/m 2 improvement a] HFOBext 15.14 37.11 HFOBint 15.37 37.54 HFILext 21.96 8.78 HFILint 17.124 28.87 REF 24.74. While position of hydrophobic mineral wool in composition of building envelope is not decisive, the right placement of hydrophilic mineral wool is crucial factor of its correct function. When it is exposed to effects of weather conditions - that means on exterior side - it is necessary to protect it against increased moisture intake, for instance using special plasters with low moisture diffusivity and low water vapor diffusion resistance factor allowing fast water evaporation. More advantageous application of hydrophilic mineral wool seems to be as internal thermal. Even if this type of insulation is not as common as external, its application is also possible and has been already studied and verified [22-24]. 4 Conclusions Energy balance of several types of AAC-based building envelopes based on results of computational analysis was performed. Unlike standard procedure of energy balance calculations, application of computational analysis gives more precise results because a broader set of input parameters is used and in particular, liquid water intake and transport is not neglected. As a disadvantage of this method, one can consider the demanding experimental analysis which requires experimental equipment and takes lot of time. However, the more accurate results which are obtained are sufficient counterbalance. Energy balance of five variations of building envelopes was compared, namely AAC provided with external and internal thermal based on hydrophobic and hydrophilic mineral wool and reference building envelope without any thermal insulation. Better energy performance was achieved when hydrophobic mineral wool was assumed. From the point of view of energy balance, application of hydrophilic mineral wool cannot be recommended on exterior side of building envelope, unless proper protection against moisture is done. In other case, this type of mineral wool should be used on interior side, where provides better thermal insulating function. It is also important to mention, energy balance is not only single decisive factor during a design of building envelope. It is necessary to focus on several other properties concurrently, such as proper hygrothermal behavior, mechanical properties or economical aspects. Acknowledgment This research has been supported by Ministry of Education, Youth and Sports of the Czech Republic, under project No SGS12/15/OHK1/2T/11. References: [1] CSN 73 54-2 Thermal protection of buildings Part 2: Requirements, Czech Office for Standards, Metrology and Testing, Prague, 211. [2] CSN 73 54-3 Thermal protection of buildings Part 2: Design values quantities, Czech Office for Standards, Metrology and Testing, Prague, 27. [3] M. I. Khan, Factors affecting the thermal properties of concrete and applicability of its predictions models, Building and Environment, Vol. 37, 22, pp. 67-614. [4] A. Karamanos, S. Hadiarakou, A. M. Papadopoulos, The impact of temperature and moisture on thermal performance of stone wool, Energy and Buildings, Vol. 4, 28, pp. 142-1411. [5] M. Jerman, R. Černý, Effect of moisture content on heat and moisture transport and storage properties of thermal insulation ISBN: 978-96-474-35-6 162

materials, Energy and Buildings, Vol. 53, 212, pp. 39-46. [6] Market observatory for energy, 21. REPORT 29 Europe s energy position markets & supply. doi:1.2768/214 [7] J. M. Cansino, M. del P. Pablo-Romero, R. Román, R. Yniguez, Promoting renewable energy sources for heating and cooling in EU- 27 countries, Energy Policy, Vol. 39, 211, pp. 383-3812 [8] V. Kočí, J. Maděra, R. Černý, Exterior thermal s for AAC building envelopes: computational analysis aimed at increasing service life, Energy and Buildings, Vol. 47, No. 1, 212, pp. 84-9. [9] R. Černý, Complex System of Methods for Directed Design and Assessment of Functional Properties of Building Materials: Assessment and Synthesis of Analytical Data and Construction of the System, Czech Technical University in Prague, 21, pp. 192 21. [1] V. Kočí, J. Kočí, J. Maděra, R. Černý, Computer code HEMOT for hygrothermal assessment of thermal insulation systems. In: Thermophysics 21. Brno: University of Technology, 21, pp. 133-14. [11] J. Kruis, T. Koudelka, T. Krejčí, Efficient computer implementation of coupled hydrothermo-mechanical analysis, Mathematics and Computers in Simulation, Vol. 8, 21, pp. 1578-1588. [12] H.M. Künzel, Simultaneous Heat and Moisture Transport in Building Components, Ph. D. Thesis. IRB Verlag, Stuttgart, Germany, 1995. [13] H. M. Künzel, K. Kiessl, Calculation of heat and moisture transfer in exposed building components, International Journal of Heat and Mass Transfer, Vol. 4, 1996, pp. 159-167. [14] J. Maděra, J. Kočí, V. Kočí, J. Výborný, R. Černý, Computational prediction of hygrothermal conditions in innovated AACbased building envelopes. In: Advanced Computational Methods and Experiments in Heat Transfer XI. WIT Press, Southampton, UK, 21, pp. 291-31. [15] V. Kočí, J. Výborný, R. Černý, Computational and experimental characterization of building envelopes based on autoclaved aerated concrete In: Materials Characterization V Computational Methods and Experiments. Southampton: WIT Press, 211, pp. 363-373. [16] M. Jerman, V. Kočí, J. Maděra, J. Výborný, R. Černý. Water and heat transport parameters of materials involved in AAC-based building envelopes. In: 1st Central European Symposium on Building Physics, Lodz: Technical University of Lodz, 21, pp. 39-45. [17] M. Jiřičková and R. Černý. Effect of Hydrophilic Admixtures on Moisture and Heat Transport and Storage Parameters of Mineral Wool. Construction and Building Materials, Vol. 2, 26, pp. 425-434. [18] M. Jerman, R. Černý. Effect of Moisture Content on Heat and Moisture Transport and Storage Properties of Thermal Insulation Materials. Energy and Buildings, Vol. 53, 212, pp. 39-46. [19] M. Jerman, M. Keppert, J. Výborný, R. Černý. Moisture and heat transport and storage characteristics of two commercial autoclaved aerated concretes. Cement Wapno Beton, Vol. 16, No. 78, 211, pp. 18-29. [2] Meteonorm Version 6, software version 6.1..2 of April 21, METEOTEST, Switzerland, 21. [21] J. Maděra, J. Kočí, V. Kočí, J. Výborný, R. Černý, Computational prediction of hygrothermal conditions in innovated AACbased building envelopes, In: Advanced Computational Methods and Experiments in Heat Transfer XI. Southampton: WIT Press, 21, pp. 291-31. [22] J. Grunewald, U. Ruisinger, P. Haupl, The Rijksmuseum Amsterdam hygrothermal analysis and dimensioning of thermal insulation. In: Research in Building Physics and Building Engineering, Taylor and Francis, London, UK, 26, pp. 345-352. [23] Z. Pavlík, R. Černý, Hygrothermal performance study of an innovative interior thermal insulation system, Applied Thermal Engineering, Vol. 29, 29, pp. 1941-1946. [24] J. Toman, A. Vimmrová, R. Černý, Long-term on-site assessment of hygrothermal performance of interior thermal insulation system without water vapour barrier, Energy and Buildings, Vol. 41, 29, pp. 51-55. ISBN: 978-96-474-35-6 163