EVALUATION OF MICROGRAVITY BACKGROUND AT THE UNDISTURBED OGUNI GEOTHERMAL FIELD, JAPAN

Similar documents
APPROPRIATE USE OF USGS VOLUMETRIC HEAT IN PLACE METHOD AND MONTE CARLO CALCULATIONS

Production/Injection Optimization Using Numerical Modeling at Ribeira Grande, São Miguel, Azores, Portugal

Ahmad Yani PT. Pertamina Geothermal Energy Lahendong, Jl. Raya Tomohon no. 420, North Sulawesi

USING A LARGE RESERVOIR MODEL IN THE PROBABILISTIC ASSESSMENT OF FIELD MANAGEMENT STRATEGIES

Baigcng Hu. Thermal Engineering Depaarnent, Tsinghua University, Beijing, , P. R. China

Interpretation of the Injection and Heat Up tests at Sabalan geothermal field, Iran

Modelling of Injection into Geothermal Systems E. KAYA 1. Department of Engineering Science, University of Auckland, Auckland, NZ M.J.

Japan Country Report 2013 IEA Geothermal Implementing Agreement

This is Reservoir Engineering COPYRIGHT. By the end of this lesson, you will be able to:

COSTA RICA COUNTRY UPDATE

Numerical study of the influence of injection/production well perforation location on CO 2 -EGS system

A simple model for low flow forecasting in Mediterranean streams

Utilizing Vertical Discharge Tests as an Effective Means for Well Decision Making at the Darajat Geothermal Field, Indonesia

Calculation of Geothermal Stored Heat from a Numerical Model for Reserve Estimation

MEASUREMENT OF GROUNDWATER TEMPERATURE FOR UNDERGROUND THERMAL UTILIZATION

Evolution of the Miravalles Geothermal Field in Costa Rica after Ten Years of Exploitation

PROVED GEOTHERMAL RESERVES FRAMEWORK AND METHODOLOGY

Decline Curve Analysis for Production Forecast and Optimization of Liquid-Dominated Geothermal Reservoir

FLOW TESTING IN INDONESIA USING ALCOHOL TRACERS

Geothermal reservoir simulation of hot sedimentary aquifer system using FEFLOW

Review of the Ogachi HDR Project in Japan

Discrete Fracture Embedding to Match Injection Returns in a Single Porosity Model

Renewable Energy Potential Evaluation and Analysis for Use by using GIS -A Case Study of Northern-Tohoku Area and Tokyo Metropolis, Japan

Developing Geothermal Energy in the Pacific Northwest. The Energy Under Our Feet

STRATEGIC ENVIRONMENTAL ASSESSMENT (SEA) FOR ENERGY SECTOR: CASE STUDY OF OLKARIA GEOTHERMAL EXPANSION PROGRAMME IN NAKURU COUNTY, KENYA.

INVESTIGATION ON SURFACE AND SUBSURFACE FLUID MIGRATION: ENVIRONMENTAL IMPACT

SOURCES OF WATER SUPPLY GROUND WATER HYDRAULICS

Geothermal Development in El Salvador Update

Tracer Dilution Measurements for Two-Phase Geothermal Production: Comparative Testing and Operating Experience

Noninvasive monitoring of CO 2 sequestration sites using airborne EM technology

Aquifer Science Staff, January 2007

Primary Recovery Mechanisms

Successful Perforation Operation Experience in a Geothermal Well of Salavatli Geothermal Field

Timber Creek Field Study for Improving Waterflooding

H.R.6. Energy Independence and Security Act of 2007 (Enrolled as Agreed to or Passed by Both House and Senate) Subtitle B--Geothermal Energy

EXERGY ANALYSIS FOR THE AHUACHAPAN AND BERLIN GEOTHERMAL FIELDS, EL SALVADOR

Drilling and Evaluation. MR explorer. Magnetic resonance logging service

Exercise 14: Estimating HC Volumes

Binary Cycle Geothermal Power Systems

Reform in China s Electric Power Industry. - A Case Study of East China s Wholesale Electric Power Market -

Modeling of Usage of Air Injection Well in a Geothermal System

DIAGNOSTICS-WHILE-DRILLING: REDUCING THE COST OF GEOTHERMAL-PRODUCED ELECTRICITY

Ground Water Quantity Measurement on the Foot of Mt. Fuji by the Use of Radioisotopes

DEVELOPMENT OF DOWNHOLE PUMP FOR BINARY CYCLE POWER GENERATION USING GEOTHERMAL WATER

Production Test Analysis Using Separator Method with Respect to Separator Efficiency

1. Apply knowledge of the controlling variables for groundwater flow. 2. Demonstrate groundwater flow direction based on hydraulic head observations.

TWENTY FIVE YEARS OF PRODUCTION HISTORY AT THE MOMOTOMBO GEOTHERMAL FIELD, NICARAGUA

ANALYSIS OF WORKOVER TECHNIQUES IN GEOTHERMAL WELLS OF CERRO PRIETO FIELD, MEXICO

MODELING THE VIABILITY OF UNDERGROUND COAL FIRES AS A HEAT SOURCE FOR ELECTRICAL POWER GENERATION

Understanding Earth Fifth Edition

MASTERING REINJECTION IN THE HELLISHEIDI FIELD, SW-ICELAND: A STORY OF SUCCESSES AND FAILURES

POSSIBILITIES FOR GROUNDWATER DEVELOPMENT FOR THE CITY OF JAKARTA, INDONESIA

Prediction of Water Production in CBM wells

EFFECT OF NATURAL CONVECTION PATTERNS ON OPTIMAL LOCATION AND SIZE OF A HEAT SINK IN A GEOTHERMAL RESERVOIR

CLIMATE CHANGE EFFECTS ON THE WATER BALANCE IN THE FULDA CATCHMENT, GERMANY, DURING THE 21 ST CENTURY

POROSITY, SPECIFIC YIELD & SPECIFIC RETENTION. Physical properties of

Heat Extraction from Deep Single Wells

Estimating Agricultural Water Consumption impacts on water level fluctuations of Urmia Lake, Iran

Permeability, Flow Rate, and Hydraulic Conductivity Determination for Variant Pressures and Grain Size Distributions

Fig. 1. Well field location

UNIT HYDROGRAPH AND EFFECTIVE RAINFALL S INFLUENCE OVER THE STORM RUNOFF HYDROGRAPH

A NOVEL TECHNIQUE FOR EXTRACTION OF GEOTHERMAL ENERGY FROM ABANDONED OIL WELLS

Summary of the Mid-term Review

Simulation of horizontal well performance using Visual MODFLOW

Application of a Basin Scale Hydrological Model for Characterizing flow and Drought Trend

Measurement of Two Phase Flows in Geothermal Pipelines Using Load-Cells: Field Trial Results

EVALUATION ON GEOTHERMAL INJECTION TREATMENT BY ph MODIFICATION

Comparison between Neuman (1975) and Jacob (1946) application for analysing pumping test data of unconfined aquifer

PHASES OF GEOTHERMAL DEVELOPMENT IN ICELAND

ENGINEERING HYDROLOGY

Binary Power Plants in New Zealand

An Improved Analogy-based Demand Forecasting Method for Service Parts

HYDRO GEO CHEM, INC. PNEUMATIC TESTING AND RECOMMENDED CHANGES AT THE SUNSHINE CANYON LANDFILL SYLMAR, CALIFORNIA. Environmental Science & Technology

CHAPTER FIVE Runoff. Engineering Hydrology (ECIV 4323) Instructors: Dr. Yunes Mogheir Dr. Ramadan Al Khatib. Overland flow interflow

Soil Temperature Monitoring and Study of Geothermal Heat Pump Systems

Enhanced Geothermal Systems (EGS) Using CO 2 as Working Fluid

Estimating Water Saturation at The Geysers Based on Historical Pressure and Temperature Production Data

Geothermal Steam Turbines for Various Purposes

Monitoring aquifer recharge using repeated high-precision gravity measurements: A pilot study in South Weber, Utah

CHEMISTRY OF THE ROTORUA GEOTHERMAL FIELD UPDATE OF SPRING AND WELL COMPOSITIONS

Japan Renewed Emphasis

BC Hydro Wind Data Study Update

Shaking table testing of liquefiable ground improved by multi-layer solid

Experiences, Successes and Challenges in Sustaining Long-Term Production at the Tiwi Geothermal Field

Water Resources Management: Vulnerability of Coastal Aquifers to Climate Change & Human Effects.

An Update Geothermal Heat Pumps in Australia

INTELLIGENT CONTROL SOLUTIONS FOR STEAM POWER PLANTS TO BALANCE THE FLUCTUATION OF WIND ENERGY

Parametric Study for Evaluation of Design Parameters of Standing Column Well

URBAN FLOODING: HEC-HMS

Agriculture and Climate Change Revisited

Renewable Energy Systems 10

Low enthalpy power generation with ORC- Turbogenerator The Altheim Project, Upper Austria

Telephone Lake project

downtown (Fig. E This enhances safety and has minimal costs (the original

Geothermal Energy in the Heart of the Rockies was a presentation introducing the subject of geothermal energy and covered the following topics:

EFFECT OF THE GRID-SHAPED STABILIZED GROUND IMPROVEMENT TO LIQUEFIABLE GROUND

Upscaling sub-core scale heterogeneity

Optimization of Process Parameters of Pressure Die Casting using Taguchi Methodology

ANALYSIS OF RAINFALLINFILTRATION

1. Introduction. Keywords Groundwater, Vulbnerability, Aquifer, Aquitard, Vadose zone. Alsharifa Hind Mohammad

Transcription:

PROCEEDINGS, Twenty-Fifth Workshop on Geothermal Reservoir Engineering Stanford University, Stanford, California, January 24-26, 2 SGP-TR-165 EVALUATION OF MICROGRAVITY BACKGROUND AT THE UNDISTURBED OGUNI GEOTHERMAL FIELD, JAPAN Chitoshi Akasaka and Shigetaka Nakanishi Electric Power Development Co., LTD. 6-15-1, Ginza, Chuo-ku, Tokyo, 14-8165, Japan e-mail: Chitoshi_Akasaka@epdc.co.jp ABSTRACT Repetitive microgravity monitoring surveys are planned to help characterize reservoir behavior after electric power generation begins at Oguni in 22. To prepare for this monitoring program, background microgravity has already been surveyed numerous times at Oguni. Seasonal changes in gravity have been observed. The observed background temporal changes in microgravity are believed to be due primarily to variations in the depth of the shallow ground water table. To separate the effects of water table fluctuations from those caused by events in the deep reservoir, we first tried to correlate both gravity changes and water table level changes with precipitation at a particular benchmark where the water level and microgravity histories were both known. Next, the resulting correlation was used to compute the effect of precipitation on microgravity elsewhere in the field, and the results were compared with measurements. Observed excursions in microgravity are somewhat greater than those estimated in this manner. INTRODUCTION The Oguni field is located in central Kyushu, southwestern Japan (Figure 1). The permeable reservoir area (established by drilling logs and pressure-transient testing) is approximately 4 km (north-south) by 2 km (east-west), and a cap rock is present between approximately 3 m RSL and 75 m RSL. Below the cap rock, temperatures range from 2 C to 24 C and a small steam zone is present at the top of the reservoir. A shallow unconfined ground water aquifer is present above the cap rock. The water table is about 1 m deep in the northern part of the field (Abe et al., 1995). A 2 MW e (gross) double-flash geothermal power plant will soon be constructed by Electric Power Development Company (EPDC) on the northwestern flank of Mt. Waita (15 m RSL), in the southeastern part of the area. Figure 1. Location and extent of the Oguni geothermal field in Kyushu, Japan Repeat gravity surveys will be performed in the future at regular intervals to help understand reservoir behavior during field exploitation. Nakanishi et al. (1998) estimated the changes in gravity which are likely to be caused by exploitation using a numerical simulation technique. Their results suggest that, after 3 years of operation, slight gravity increases (about 35 µgal) will occur in the main reinjection wellfield to the north. Relatively large gravity decreases (about 13 µgal) centered on the middle of the production wellfield are also predicted, caused by production-induced local pressure decline and associated boiling (Figure 2). Since these predicted gravity disturbances are rather small, accurate measurements will be required and careful noise reduction techniques must be employed.

INJECTION We started precise gravity observations in May 1996 and continued for about 3 years, measuring gravity monthly at each of the 41 benchmarks relative to a reference benchmark located about 11 km from the geothermal field. The Geographical Survey Institute (GSI) maintains this first-order leveling benchmark used for reference. The reference benchmark is far enough from the geothermal field that exploitationinduced gravity changes are not expected. YAMAKAWA PRODUCTION -1-5 -25 Mt.WAITA A CG-3M gravity meter was used to measure gravity. This gravity meter was calibrated to yield relative gravity difference from the reference point. Precise leveling surveys have been conducted twice during the period of gravity measurements, and indicate that ground surface elevation changes were less than the ability of the leveling network to measure them. Consequently, gravity changes caused by earth subsidence or swelling were completely negligible. Figure 2. Calculated gravity changes caused by 3 years operation of the 2 MW e Oguni geothermal power plant At Oguni, large and rapid changes in the water table depth take place because of the mountainous terrain and the relatively heavy local precipitation. Between 199 and 1999, natural water table depth fluctuations (attributable to rainfall) exceeded 16 meters. Consequently, microgravity changes caused by water table fluctuations are likely to represent a significant fraction of the total measurable temporal gravity signal. If the noise introduced by water table variations could be compensated for directly, based on rainfall records, corrections could be applied in areas where no observation wells are present. This method can also help compensate for the effects upon gravity of changes in water saturation in the vadose zone. PROCEDURE Precise gravity observations A total of 41 benchmarks have been established for gravity monitoring in the Oguni geothermal field (Figure 3), lying at elevations between 519 and 195 m RSL. The benchmarks were situated in locations where substantial gravity changes due to reservoir disturbances caused by geothermal power plant operations are expected, based on forecasts using the STAR reservoir simulator and surface gravity postprocessor (Pritchett, 1995) see Figure 2. Figure 3. Location map of measurement area, measurement benchmarks, observation wells of shallow ground water table and rainfall measurement station Estimating water table changes from rainfall data Precipitation measured in the northern part of the Oguni field is shown in Figure 4, together with the history of the measured water level in shallow observation well BW-2 (near benchmark 21).

Precipitation(mm) 28 26 24 22 2 18 16 14 12 1 8 6 4 2 Daily Precipitation 9 91 92 93 94 95 Measured Groundwater Level Figure 4. Precipitation and ground water level changes measured in shallow well BW-2 8 78 76 74 72 7 68 66 64 62 6 Groundwater Level(mRSL) RESULTS To illustrate representative results, long-term gravity change histories measured at benchmarks 21 and OG-15 are shown in Figure 5 and 6, respectively. Locations of these benchmarks are indicated in Figure 3. Gravity changes at station 21 are substantial, consisting mainly of large abrupt shifts in November 1996 and November 1998 which interrupt a history that is otherwise relatively smooth and continuous. The reasons for the abrupt gravity discontinuities are not known. By contrast, the Benchmark OG-15 measurements exhibit relatively small fluctuations and regular seasonal changes. The large shifts that occurred at benchmark 21 were not observed at OG-15. Rainfall is heavy at Oguni. Annual total rainfall has varied between 113 and 345 mm during the past decade. Average annual rainfall is 225 mm. Well BW-2 was drilled to observe the shallow unconfined water table above the cap rock. Overall, the range of water level excursions in BW-2 was 16.9 meters during this period. Increases in ground water level in this well clearly correspond to rainfall (Figure 4). When a rainstorm occurs, the water level in the well first increases suddenly and then decreases gradually. Accordingly, an empirical exponential decrease equation (Yuhara and Seno, 1969) was used to correlate precipitation with water level in the well: H(t) = H 1 +ασ n R n exp{-c(t-t n ) } (1) where H 1 is an initial ground water level before rainfall, t represents time, α and c are constants, and R n is the precipitation (mm) which falls on day t n. Calculation of gravity change from precipitation Using the above relation to obtain water table depth changes from precipitation data, we next calculate the resulting gravity changes using the relationship of Allis and Hunt (1986); g=2πgφρ w h (2) where g is the gravity change (µgal = 1-8 m/s 2 ), G (6.67 1-11 m 3 kg -1 sec -2 ) is the universal gravitational constant, φ is the porosity near the water table depth, ρ w is the density of ground water (kg m -3 ), and h is the change in water level (m). Several shallow observation wells distributed widely in the northern Oguni area exhibit similar ground water table elevations (relative to sea level). This suggests that the infinite-plane approximation implicit in Eq. (2) is appropriate, at least for the northern part of the field. Gravity Change (1-8 ms -2 ) 4 3 2 1 Site 21 Figure 5. Measured changes in surface microgravity at benchmark 21. Note the step changes in late 1996 and 1998. Gravity Change (1-8 ms -2 ) 4 3 2 1 Site OG-15 Figure 6. Measured changes in gravity at benchmark OG-15. Differences in absolute gravity acceleration among the various 41 benchmarks arising from elevation differences alone exceed 13, µgal. The amount of overall temporal gravity variability that was observed at each benchmark seems to be proportional

to the difference in absolute gravity acceleration between the benchmark in question and the reference benchmark. Therefore, we suspect that systematic errors are involved, caused by measurement or data processing problems. Data analysis was therefore limited to the stable period between the two large shifts. Applying equation (1) to the rainfall data and the water level measured in well BW-2, a least-squares fitting procedure yielded the following optimum values for the free parameters: H 1 =671 (m RSL), α=.937 and c=.99 (day -1 ) The ground water level history calculated using these parameters is compared with the actual water level measurements in Figure 7. The porosity at the ground water level was estimated to be.11 by leastsquares correlation of measured water level changes with gravity changes. This value is reasonable for the shallow ground water aquifer in the area. The gravity change history that was calculated based on the inferred changes of water table depth is shown in Figure 8 together with the gravity changes observed at station 21. On the whole, the general features of the observed gravity history are reproduced by the calculation. Next, however, we applied the same technique to nearby station 22. As figure 9 shows, the resulting calculated gravity history does not correlate very well with measured values, although both benchmarks are obviously located on the same unconfined ground water system and would therefore be expected to exhibit similar water table depth histories and resulting microgravity changes. DISCUSSION Gravity changes have been observed at all 41 Oguni benchmarks. The overall amplitudes of the gravity changes are relatively large in regions of high ground surface elevation, and the observed changes increase in proportion to the difference in absolute gravity acceleration between the station in question and the distant reference benchmark. The most stable benchmark (OG-15) has the smallest absolute gravity difference from the reference point. We have also carried out simultaneous comparative measurements using a second gravimeter, and very similar results were obtained. However, the slight difference in gravity values obtained from the two gravimeters also appears to be in proportion to station elevation. For that reason, we believe that the gravimeter calibration was insufficient for the accuracy requirements of this program. Additional and more precise calibrations need to be carried out using additional reference benchmarks to cover the entire absolute gravity range prevailing in the Oguni field. Precipitation(mm) Figure 7. Precipitation and ground water table in well BW-2 Gravity Change (1-8 ms -2 ) 2 1-1 -2 Site 21 Figure 8. Comparison between observed and calculated gravity values at benchmark 21. Gravity Change (1-8 ms -2 ) 28 26 24 22 2 18 16 14 12 1 8 6 4 2 2 1-1 -2 9 91 92 93 94 95 Site 22 Figure 9. Daily Precipitation Measured Groundwater Level Calculated Groundwater Level Residual Measured Calculated from Precipitation Calculated from Groundwater Level Measured Calculated from Precipitation Comparison between observed and calculated gravity values at benchmark 22. 8 78 76 74 72 7 68 66 64 62 6 Groundwater Level(mRSL)

To further improve the accuracy of the measurements, the gravity history at the reference benchmark should be more completely characterized. Alternatively we can connect an absolute gravity point to the reference benchmark with a relative gravity meter. The reference benchmark should be located where the gravity is expected to be sufficiently stable. An imperfect correlation was observed between ground water table fluctuations and temporal gravity changes at Oguni. Continuous gravity measurements appear to be necessary during periods of rapid change in ground water table caused by heavy rainfall. Ten meters of water table level change can occur at Oguni within a few months. If continuous gravity monitoring were carried out at a few representative stations at Oguni, gravity changes caused by ground water table changes could be better characterized. The potential value of continuous microgravity monitoring for geothermal reservoirs has been shown by Sugihara (1999). Of course, the situation is likely to be more promising at other geothermal sites with less rainfall. SUMMARY Temporal changes in microgravity have been monitored during a three-year period prior to the onset of Oguni geothermal field exploitation, while human activities at the site were at a minimum. Ground water table changes are believed to be the primary reason for the observed gravity fluctuations. We attempted to establish a relationship between ground water level and gravity, but a good correlation was not obtained. On the other hand, marked temporal microgravity changes were detected at several benchmarks. We recommend that continuous microgravity monitoring be carried out in the future, at least at a few representative stations. Accurate delineation of changes in gravity at the reference benchmark will be essential for precise characterization of the changes in gravity with time at the Oguni geothermal field. ACKNOWLEDGEMENTS The precipitation and ground water level data were acquired by the New Energy and Industrial Technology Development Organization (NEDO) Development of Binary Cycle Plant project, a part of the New Sunshine Project supported by the Agency of Industrial Science and Technology (AIST) of the Japanese Ministry of International Trade and Industry (MITI). Mr. T. Nuruyu (Kaihatsu Koji Co.) acquired the microgravity data. All digital data processing was carried out by Mr. H. Oshima of the Kaihatsu Computing Center. REFERENCES Abe, M., Yamada, M., Kawano, Y., Todaka, N., and Tezuka, S. (1995). Development of the Oguni Geothermal Field, Japan. Proc. World Geothermal Congress 1995, pp. 1319-1322 Allis, R.G., and Hunt, T.M. (1986). Analysis of exploitation-induced gravity changes at Wairakei Geothermal Field. Geophysics, Vol. 51, pp. 1647-166. Nakanishi, S., Iguchi, K., Akasaka, C., and Iwai, N. (1998). Microgravity Monitoring for the Oguni Geothermal Reservoir System, Japan, A preliminary correction of seasonal gravity changes before exploitation. Geothermal Resources Council Transactions, vol. 22, pp. 179-189 (Errata pp.11-16) Pritchett, J. W. (1995). STAR: A geothermal reservoir simulation system. Proc. World Geothermal Congress 1995, pp. 2959-2963. Pritchett, J. W.(1995). STAR Users Manual S- Cubed Report No.SSS-TR-92-1336, revision E. Sugihara, M. (1999). Continuous gravity measurements for reservoir monitoring Proc. Twenty-fourth Workshop on Geothermal Reservoir Engineering Stanford University, pp. 287-292 Yuhara, K. and Seno, K. (1969). Onsengaku. Chiginsyokan, Tokyo. pp.56-6 (in Japanese).