The Agilent 6545 Q-TOF LC/MS System. The Answers You Need:

Similar documents
Breakthrough ifunnel Technology

Agilent 6490 Triple Quadrupole LC/MS System REACH ULTIMATE SENSITIVITY WITH BREAKTHROUGH IFUNNEL TECHNOLOGY

Agilent 6400 Series Triple Quadrupole LC/MS. Breakthrough sensitivity now routine for your lab

Faster, easier, flexible proteomics solutions

The clearly better choice

performance and throughput

Agilent 6000 Series LC/MS Solutions CONFIDENCE IN QUANTITATIVE AND QUALITATIVE ANALYSIS

faster, confident more path to all the information in your samples. Agilent MassHunter Workstation Software Our measure is your success.

Agilent InfinityLab LC/MSD Series EXTEND THE BOUNDARIES OF YOUR ANALYSIS

HIGHER IMPACT LC/MS DIAGNOSTICS AGILENT IN VITRO DIAGNOSTIC MEDICAL DEVICES FOR CLINICAL LABORATORIES

Agilent 6430 Triple Quadrupole LC/MS System

MassHunter Profinder: Batch Processing Software for High Quality Feature Extraction of Mass Spectrometry Data

Proudly serving laboratories worldwide since 1979 CALL for Refurbished & Certified Lab Equipment QTRAP 5500

Expand Your Research with Metabolomics and Proteomics. Christine Miller Omics Market Manager ASMS 2017

AB SCIEX TripleTOF 5600 SYSTEM. High-resolution quant and qual

Agilent Food Profiling Solutions ASSESS FOOD QUALITY AND POINT OF ORIGIN

Agilent solutions for contract research and manufacturing organizations

Thermo Scientific TSQ Quantum Access MAX

Agilent 1260 Infinity II LC ASPIRE TO NEW LEVELS OF EFFICIENCY EVERY DAY IN EVERY WAY

Agilent 7693A Series Automatic Liquid Sampler. Inject new performance into your gas chromotography

Confident Pesticides Analysis with the Agilent LC/Triple Quadrupole and TOF/QTOF Solutions

Agilent 7820A GC System THE EASY CHOICE FOR ROUTINE ANALYSES

Precise Characterization of Intact Monoclonal Antibodies by the Agilent 6545XT AdvanceBio LC/Q-TOF

EPA Method 543: Selected Organic Contaminants by Online SPE LC/MS/MS Using the Agilent Flexible Cube

easy. HPLC has never been so Agilent 1120 Compact LC Our measure is your success.

Agilent 6500 Series Q-TOF LC/MS System

Fast and Efficient Peptide Mapping of a Monoclonal Antibody (mab): UHPLC Performance with Superficially Porous Particles

Featuring Analyst software under Windows NT for enhanced performance and ease of use. API 150EX. LC/MS System

Application Note. Abstract. Authors. Introduction. Environmental

Agilent 7693A Series Automatic Liquid Sampler INJECT NEW PERFORMANCE INTO YOUR GAS CHROMATOGRAPHY

Agilent 5100 ICP-OES DUAL VIEW ICP-OES MINUS THE WAIT

Accurately Identify and Quantify One Hundred Pesticides in a Single GC Run

Above and beyond the extraordinary

High Levels of Sensitivity and Robustness for Complex and Demanding Matrices SCIEX TRIPLE QUAD 5500 SYSTEM

ICP Expert software. Technical Overview. Introduction

Agilent OpenLAB CDS. Manage your chromatography better than ever before

LC/MS/MS Solutions for Biomarker Discovery QSTAR. Elite Hybrid LC/MS/MS System. More performance, more reliability, more answers

Pharmaceutical LC/MS Solutions from Agilent Technologies

MultiQuant Software Version 3.0

Agilent 1220 Infinity II LC GET ON THE FAST TRACK TO HIGHEST EFFICIENCY AT A PRICE YOU CAN AFFORD

The LC-MS/MS Workhorse. SCIEX 4500 Series Mass Spectrometers

Agilent 7693A Series Automatic Liquid Sampler INJECT NEW PERFORMANCE INTO YOUR GAS CHROMATOGRAPHY

PLRP-S Polymeric Reversed-Phase Column for LC/MS Separation of mabs and ADC

Puzzled About LCMS? Sample. Sensitivity in Mass Spec Analysis. Prep. Adapting LC-UV. Optimizing and Maintaining Your Mass Spec LCMS

Fast and High-Resolution Reversed-Phase Separation of Synthetic Oligonucleotides

MasterView Software. Turn data into answers reliable data processing made easy ONE TOUCH PRODUCTIVITY

Technical Overview. Author. Abstract. Edgar Naegele Agilent Technologies, Inc. Waldbronn, Germany

Antibody Analysis by ESI-TOF LC/MS

Agilent 8355 Sulfur Chemiluminescence Detector REIMAGINED. REDESIGNED.

Agilent 6400 Series. System. Concepts Guide. The Big Picture. Agilent Technologies

PESTICIDE SCREENING APPLICATION SOLUTION

TurboMass GC/MS Software

[ VION IMS QTOF ] BEYOND RESOLUTION

Peptide Mapping of Glycoprotein Erythropoietin by HILIC LC/MS and RP-LC/MS

Metabolic Changes in Lung Tissue of Tuberculosis-Infected Mice Using GC/Q-TOF with Low Energy EI

Liquid Chromatograph Liquid Chromatograph Mass Spectrometer. CL Series. for In Vitro Diagnostic Use

Thermo Scientific TSQ Quantiva Triple-Stage Quadrupole Mass Spectrometer. Extreme quantitative performance. with unprecedented ease

Thermo Scientific Peptide Mapping Workflows. Upgrade Your Maps. Fast, confident and more reliable peptide mapping.

The Use of High Resolution Accurate Mass GC/Q-TOF and Chemometrics in the Identification of Environmental Pollutants in Wastewater Effluents

Changing the Game in LC-MS/MS. New Tools for Unprecedented Performance in Residue Analysis. Dr. Thomas Glauner

Screening for Emerging Chemical Contaminants in Water Using LC/Q-TOF and Mass Profiler Professional Software

Method Translation in Liquid Chromatography

ADVANCE ACCURACY AND PRODUCTIVITY FOR FASTER ANALYSIS

QUANLYNX APPLICATION MANAGER

Agilent RapidFire 360 High-throughput Mass Spectrometry System. Innovative Integrated Technology

Analysis of Illegal Dyes in Food Matrices Using Automated Online Sample Preparation with Liquid Chromatography-Mass Spectrometry

Heart-cut 2D-LC/MS approach for pharmaceutical impurity identification using an Agilent 6540 Q-TOF LC/MS System

Exploring Extra Sensitivity Using ionkey/ms with the Xevo G2-XS Q-Tof HRMS for Small Molecule Pharmaceutical Analysis in Human Plasma

Agilent Resources for Workflow Compliance MEASURING ELEMENTAL IMPURITIES IN PHARMACEUTICAL MATERIALS

With the globalization of trade, food production

Designed for the Modern Chromatography Lab. Agilent OpenLab CDS

Automated Online SPE for LC/MS/MS Analysis of Trace Organic Contaminants in Water Using the Agilent 1290 Infinity Flexible Cube Module

Thermo Scientific Compound Discoverer Software. Integrated solutions. for small molecule research

Microflow Liquid Chromatography Mass Spectrometry System. Nexera Mikros C146-E350

Rapid Soft Spot Analysis using the SCIEX Routine Biotransform Solution

AMAZINGLY CAPABLE REMARKABLY AFFORDABLE. Avio 200 ICP Optical Emission Spectrometer. For research use only. Not for use in diagnostic procedures.

Minimize Method Development Time for Pesticide Screening Using LC/MS Application Kit

icap 7000 Plus Series ICP-OES Streamlined performance and ultra-low ICP-OES detection limits for routine laboratories

Characterize Fab and Fc Fragments by Cation-Exchange Chromatography

Infinitely better. Agilent 1200 Infinity Series. Infinity LC. Infinity LC. Infinity LC. products applications soft ware services

SCION GC Series. The Gas Chromatographers Choice for Separations

Laboratory Reagents. for life science research.

THE SOURCE OF NEW POSSIBILITIES

rapiflex Innovation with Integrity Designed for Molecules that Matter. MALDI TOF/TOF

Rapid Peptide Catabolite ID using the SCIEX Routine Biotransform Solution

THE TRIPLE QUAD THAT KNOWS THE VALUE OF TIME. QSight Triple Quadrupole LC/MS/MS

Thermo Scientific icap 7000 Plus Series ICP-OES. Gain more power. experience more performance

Advantages of Ion Mobility QTOF for Characterization of BioPharma Molecules

REGULATORY PESTICIDE ANALYSIS JUST GOT EASIER. QSight Pesticide Analyzer

Proteins. Patrick Boyce Biopharmaceutical Marketing Manager Waters Corporation 1

N-Glycan Profiling Analysis of a Monoclonal Antibody Using UHPLC/FLD/Q-TOF

Peptide Mapping: A Quality by Design (QbD) Approach

Thermo Scientific Solutions for Intact-Protein Analysis. Better, Faster Decisions for. Biotherapeutic Development

Highly Confident Peptide Mapping of Protein Digests Using Agilent LC/Q TOFs

Application of Agilent AdvanceBio Desalting-RP Cartridges for LC/MS Analysis of mabs A One- and Two-dimensional LC/MS Study

Thermo Scientific icap 7000 Series ICP-OES. Low cost ICP-OES analysis high quality data

A Complete Workflow Solution for Intact Monoclonal Antibody Characterization Using a New High-Performance Benchtop Quadrupole- Orbitrap LC-MS/MS

AGILENT S BIOINFORMATICS ANALYSIS SOFTWARE

Agilent University Course Catalog Edition Thailand

Agilent Sample Preparation Portfolio ACCURATE, REPRODUCIBLE RESULTS RIGHT FROM THE START

Transcription:

The Agilent 6545 Q-TOF LC/MS System The Answers You Need: Better, Faster, Easier

The Agilent 6545 Q-TOF LC/MS System Faster Answers Better Measurements Easier High Performance Results The new 6545 Q-TOF incorporates hardware and software innovations to enhance quality, significantly improve instrument robustness and increase overall performance. The result: a new standard for robust, high-productivity, high-sensitivity performance. New advances in the MassHunter software suite incorporate advanced data mining and processing tools that let you rapidly and accurately extract all available information from the compounds in your samples not just peaks and data points, but answers. The new 6545 Q-TOF is designed to make your MS analyses faster, easier, and more productive, whether you are doing pharmaceutical research, food safety analysis, forensics/toxicology, environmental analysis, metabolomics, or lipidomics. 2

Challenge The 6545 Q-TOF Solution The trace level compounds you seek are inaccurately quantified or missed altogether. The new Swarm autotune with improved optimization capabilities delivers more reliable answers, with dramatically improved sensitivity for small molecule compounds. Lower ion optics voltages help to preserve fragile compounds. Complex sample analyses require significant time and expertise. Easy instrument optimization puts precise results within reach of the non-expert. Enhanced analytical tools promote confidence and productivity delivering answers faster. You need to do more with less: develop more methods, handle increased workloads. Rugged reliability for routine screening with the sensitivity needed for compound identification. Agilent databases and PCDLs reduce the time needed to get answers. 3

Being there when it matters the most Octopole region MS1 quadrupole analyzer Lens 2 ion optic larger diameter provides greater robustness New Agilent High Voltage (HV) pulser and HV power supply design provides greater reliability and robustness 4 Higher robustness than previous generation instruments All the improvements incorporated into the Agilent 6545 Q-TOF have produced improved resolution, enhanced sensitivity and a third important outcome: higher robustness than the previous generation of instrument. In addition to the high-energy optics, the 6545 features additional improvements in two key areas that significantly enhance ruggedness and reliability: A new-generation detector that offers significantly improved longevity, while still delivering high sensitivity and wide dynamic range. Next-generation electronics subsystems that substantially increase the robustness of our high-speed TOF electronics.

Hexapole collision cell New Optics Ion beam shaping optics and wider slicer position for > 2 times reliability improvement more consistent results and longer usage between cleaning New Enhanced gain shifted detector, with 3X longer life, for greater reliability and lower cost of ownership Relentless attention to detail and technology development Ion beam compression and shaping Ion beam compression and shaping (IBCS) technology provides great sensitivity while maintaining over 45K mass resolution and sub 1 ppm mass accuracy. Enhanced electronics and software algorithms enable exceedingly high data acquisition rates up to 50 spectra/second. Agilent JetStream thermal gradient focusing A precisely micro-machined sprayer surrounds ESI droplets with a sheath of superheated gas to desolvate and concentrate ions near the MS inlet for more effective sampling. Automated slicer assembly Continuous refinement of the ion optics design combine to deliver robust performance for the most demanding combined qualitative and quantitative applications. Flight tube power supplies Each of the three main power supplies controlling the flight tube has been redesigned to deliver substantially better stability for mass accuracy and mass resolution. 5

Faster optimization: Swarm Autotune with Particle Swarm Optimization Now it s easier than ever for every user to get exceptional results What if tuning your instrument could be like autofocus on a camera? In developing the new 6545, Agilent s development team listened to customers who want ease of use together with automated optimization. The Agilent 6545 Q-TOF revolutionizes that process, with an innovative autotune that incorporates Particle Swarm Optimization (PSO). Swarm Autotune provides: Radically faster autotune speed 4x faster than previous generation Q-TOFs. Optimization options for small molecules automatically delivers enhanced sensitivity for the best small molecule peformance. Positive Negative Fast Polarity Switching Quadrupole TOF Both Mass Calibration/Check Standard Tune Set Detector Gain Initial Tune 50-1700m/z 50-750m/z 50-250m/z Fragile Ions Particle Swarm Optimization PSO is a flexible and robust multidimensional optimization algorithm that can optimize up to 21 parameters simultaneously even when no initial signal is present and can avoid getting trapped in local optima. It can optimize elements for a target resolution, level of fragmentation, or for maximum sensitivity with a simple start tune button. The new Swarm Autotune simplifies the optimization of multiple instrument parameters and is adjusted to allow for more ion transmission, more speed, and lower loss of fragile molecules. Course TOF Resolution-Puller Offset Optimization Charge Puller Offset from 32.0 to Optimum Value at 35.8 Peak Resolution Score Raw Data Average Data 0.14K 0.13K 0.12K 0.11K 0.10K 0.09K 0.08K 0.07K 0.06K Optimum Previous Optimum Previous 20 25 30 35 40 45 50 Value Transmission Optimization Signal Improved 7.5% Best Solution Particle 4 Particle 8 35000 Geometric MeanPeak Height 30000 25000 20000 15000 10000 Particle 1 Particle 5 Particle 9 Particle 2 Particle 6 Particle 10 Particle 3 Particle 7 Optimum Learning 5000 Exploring 0 0 5 1015202530354045505560 Iterations 6

Application Focus: Food AND WATER Analysis Screen and identify pesticide residues with unsurpassed speed and sensitivity Unparalleled accuracy in mass measurements and isotope ratios make Q-TOF LC/MS systems the ideal choice for detection and identification of pesticides. Exceptional system sensitivity allows for the detection and quantitation of trace level compounds, enabling food testing labs to keep pace with evolving regulations and confidently identify new, emerging contaminants. Enhanced Sensitivity of 6545 Q-TOF for Pesticides in Black Tea at 2 ppb # of Compounds 140 120 100 80 60 40 20 0 82 85 24 13 11 2 1-2x 2-3x 3-4x 4-5x 5-6x >6x Increase in sensitivity A 4-5x increase in sensitivity was observed for more than 80% of compounds detected. Water Contaminants The consistently superior sensitivity of the 6545 Q-TOF LC/MS system makes it ideal for detection and quantitation of both targeted and non-targeted PPCP compounds. Surface Water Analysis: 6545 vs. 6540 40 35 30 25 20 15 10 5 0 Surface Water 1 Surface Water 2 # of Compounds Detected The 6545 detected a greater number of contaminants in surface water compared to the 6540 Q-TOF. 6540 6545 Identification of Dextrorphan in Contaminated Surface Water x10 5 3 2.5 2 1.5 1.0 0.5 0 12.137 x10 8 2 12 12.2 12.4 Counts vs. Aquisition 11.8 11.9 12 12.1 12.2 12.3 12.4 12.5 Countra vs. Acquisition Time (min) Dextrorphan can be detected in the presence of 1000x co-eluting ions by the Agilent formula-generating algorithm. 7

All Ions MS/MS Identify and quantitate with higher confidence All Ions MS/MS is a great solution for screening analytes in food, environmental, and forensic/toxicology applications. Agilent offers a fully developed All Ions MS/MS workflow for compound confirmation and quantitation, featuring: Easy acquisition method setup even for multi-compound screening. - Links to knowledge bank in PCDLs (extracts MS/MS fragmentation properties for all compounds in a screen). - Unique Co-elution score of diagnostic fragment ions used to verify hits. - Easily add new targets to the PCDL to continually expand the scope of screening over time. - A full spectrum of molecular ions plus their major fragments are always collected so data can be re-interrogated retrospectively when these new targets are added. Rapid quantitation method development that automatically selects two high-quality product ions for each compound. Overlaid Chromatogram Co-elution plot 8

Targeted MS/MS Quickly quantify, find and identify compounds with targeted MS/MS, databases, and PCDLs Targeted MS/MS and the pesticides PCDL together allow quick quantitation, identification and confirmation of unknown contaminants in a black tea sample. The 6545 Q-TOF combines quantitative requirements for screening applications with the qualitative requirements for compound identification based upon accurate mass and PCDL MS/MS library matching. Quantitation and structure confirmation of dimethoate in avocado matrix by targeted MS/MS Responses x10 8 4 3.5 3 2.5 2 1.5 1 0.5 0 R^2=0.99156207 New PCDLs Support Easier Accurate Results Agilent is committed to supporting easier, more accurate results in research and regulated labs by investing in the development of databases and personal compound database libraries (PCDLs). One example is the upcoming mycotoxins database, developed in collaboration with the University of Natural Resources and Life Sciences, Vienna (BOKU), Austria. Hundreds of mycotoxins were added to the database and high resolution MS/MS spectra were obtained for those fungal metabolites. The new mycotoxins library will help food scientists to find and confirm unambiguously the presence of hundreds of potentially harmful contaminants without needing to actually have the standard compounds. Armed with this data, researchers and government labs can make informed decisions about which analytical standards to purchase for quantitation. 0 10 20 30 40 50 60 70 80 90 100 Concentration (ng/ml) x10 3 1 0.75 0.5 0.25 0-0.25-0.5-0.75-1 -1.25 Counts Lib Match Score=59.3 135.0433 366.1433 422.2074 135.0437 366.1442 100 200 300 400 500 600 700 800 900 1000 Mass-to-Charge (m/z) Calibration curve represents 1 ng/g to 100 ng/g at 6 levels. Most of the pesticides can be detected at or below maximum residue limit (MRL) of 10 ng/g in complex matrices, matched with the Agilent Personal Compound Database and Library (PCDL). 9

Greater Efficiency and Confidence: A TEAM EFFORT Agilent 1290 Infinity II LC The Agilent 1290 Infinity II LC includes a novel multisampler, alternative pump configurations, and faster injection cycles to help you achieve unmatched separation and detection performance for data of the highest quality. Learn more at www.agilent.com/chem/1290. Agilent Poroshell 120 and ZORBAX RRHD columns The Poroshell 120 family provides consistent, reliable performance for U/HPLC applications. Start with EC-C18 chemistry for the best all-around performance. With 13 chemistries including Poroshell HPH, designed for robust performance in high ph conditions, you can refine your methods to support the highest LC/MS sensitivity and compound identification. Learn more at www.agilent.com/chem/poroshell120. The Q-TOF provides datarich files, with the accurate mass allowing very narrow extracted ion ranges to reduce noise to near-zero values, as well as the determination of chemical formulae of unknowns. I can quantitate in either MS or MS/MS mode with good linearity and dynamic range, and software tools make database and library searching very easy. I can also do retrospective searches on old data for new compounds reported in the literature or media, just by adding them to my searchable database. 10 Ralph Hindle, Vogon Laboratory Services, Ltd.

Software and services supporting your work Agilent MassHunter Workstation software Agilent MassHunter Workstation software was designed to make your MS analyses faster, easier, and more productive. In addition to data acquisition, and instrument control for your Agilent LC/MS, GC/MS, and ICP-MS instruments, the software incorporates advanced data mining and processing tools. MassHunter Workstation software data mining capabilities integrate with Agilent s Personal Compound Database & Library (PCDL), offering the ability to use accurate mass MS/MS libraries for screening and confident identification of compounds of interest, as well as the flexibility to create customized PCDLs. Pesticide analysis PCDL PCDL for Metabolomics (METLIN) PCDL for compounds of forensics/toxicology concern (Broecker, Herre & Pragst) PCDL for mycotoxins/fungal metabolites PCDL for veterinary drugs MassHunter Software MassHunter software provides comprehensive tools to help you address all the requirements of GLP/GMP and 21 CFR Part 11 compliance. Agilent also offers a complete suite of Installation and Operation Qualification services to shorten the time between installation and running critical samples. OpenLAB CDS OpenLAB CDS software increases the efficiency of your lab by reducing the time you spend on data processing, review, and reporting. With OpenLAB CDS, you can easily create reports using powerful and intuitive drag-and-drop capabilities, and process large datasets up to 40 times faster. Scale from a single instrument to a lab-wide network, with centralized system administration and the ability to work from anywhere you choose, in an environment that enables 21 CFR Part 11 and EU Annex 11 compliance. 11

The Agilent Value Promise: 10 years of Guaranteed Performance In addition to our continually evolving products, Agilent offers the industry s only 10-year value guarantee. Agilent guarantees you at least 10 years of instrument use from your date of purchase, or we will credit you with the residual value of that system toward an upgraded model. It s our way of assuring you of a safe purchase now, and protecting your investment into the future. Learn more www.agilent.com/chem/6545_qtof Buy online www.agilent.com/chem/store Find a local Agilent customer center in your country www.agilent.com/chem/contactus USA and Canada 1-800-227-9770 agilent_inquiries@agilent.com Europe info_agilent@agilent.com Asia Pacific inquiry_lsca@agilent.com Research Use Only. Information, descriptions, and specifications in this publication are subject to change without notice. Agilent Technologies shall not be liable for errors contained herein or for incidental or consequential damages in connection with the furnishing, performance, or use of this material. Agilent Technologies, Inc., 2015 Printed in the USA, February 13, 2015 5991-5468EN