Inspection Xpress. Property Inspection Report

Similar documents
3D Home Improvement and Inspection Services, Inc

Watson Home Inspection Services, LLC.

Collier Home Inspections, LLC

Inspection Report. 1 of 8

Greater Dayton Home Inspections

Work Write Up / Specification of Repairs HUD DIVISION 1. MASONRY HUD DIVISION 2. SIDING. Toll Free

Inspection Report. Provided by: Cummins Services LLC. Inspector: Bill Cummins. Phone:

InterNACHI Home Inspection Report Checklist

TOWNSHIP OF LOGAN 125 MAIN STREET, PO BOX 314 BRIDGEPORT, NJ FAX

Property Inspection Report

Edouard AVANT GROVE U I C U I C. Modern Living Made Easy uichomes.com

Inspections Unlimited 12:38 August 20, 2013 Page 1 of 23 Sampleweb2013.pt6

How's My House Home Inspections LLC

FAIRA TRANSPARENCY REPORTS S 124th St, Seattle, WA May 16 th, 2017

Pacific Inspection Group Keaau-Pahaoa Rd Keaau, Hawaii Somewhere In Paradise Keaau, Hawaii 96749

Davis Frame Co., Inc. Construction Budget Considerations

Storm Damage Assessment Report For: 1234 Example Street., Houston, TX 77002

Qualifying Process for Handyman Online Qualifying Questions. Name: Street Address: City: State: Zip Code. Home Phone: Cell Phone: Address:

Highland Park. Exceptional Interiors (cont.) Green Technology. Designer Kitchen Features. Distinctive Exterior Features

Report exclusively for You!

New Homes Forestbrook Road. Yes, it s INCLUDED!

Feasibility Report. Property Inspection Engineers, Inc. (248) Property Address. 405 Fairgrove Royal Oak, MI.

By: Ricci Construction Group Cheshire, CT

New Homes Starting at $124,900

Home Inspection Report

Report. Inspection Date: 01/01/2000. Prepared For: John Q. Public. Prepared By: A1 Certified Home Inspections. Lake City, FL 32024

TEXAS DEPARTMENT OF HOUSING AND COMMUNITY AFFAIRS OFFICE OF COLONIA INITIATIVES TEXAS BOOTSTRAP LOAN PROGRAM. Form 15 Work Write-Up

Features & Amenities. EXTERIOR FINISHES COMMUNITY FEATURES

Continuing Certificate of Occupancy Pre-Inspection Checklist

Pembridge The Country Club Collection TOWNHOMES AT CRYSTAL SPRINGS

Sample Short Sale Condo.

SUMMARY. Appliance: Corrective Action(s)

Quality Inspection 8618 London Heights San Antonio, TX Phone: (210)

G. Warren, Inc. Metuchen, NJ Definitions

Atlantic Builders Saratoga Woods Included Features Classic Series Single Family Homes Included Features - Bridgewater II, Griffin, Ashland, Chelsey

Opening Soon! Ian Weber & Sam Melendez (239) Gopher Tortoise Trail Lehigh Acres, FL 33971

CONSTRUCTORA VARGAS NICARAGUA Building Inspection Las Delicias San Juan del Sur - Rivas Nicaragua

Home Inspection Report. LH Home Services Edgewater McCall, Idaho

FLOORPLAN /ELEVATION SQ.FT. BDRM BATHS GARAGE BASE PRICE

HOUSE REPAIRS & RENOVATIONS BUILDING PERMIT REQUIREMENTS

For Review Only, Sample Report. All About Homes, Inc. Residential Inspections

INSPECTION REPORT October 13, 2017

REPORT SUMMARY. June 15, Pat Jones 123 Washington Chicago, IL Forest Evanston, IL. Dear Pat Jones,


TML Home Inspectors, Inc.


CHARTRES COURT Washington Avenue Houston, Texas ChartresCourtHouston.com CHARTRES COURT LLC

Sample Home Inspection

Repair or replace section of driveway, approach, or sidewalk that are a trip hazard.

HOME INSPECTION REPORT

Page 3 of 12. Inspected Describe. Explained. Health & Safety. Maj. Def. Examiner Notes STRUCTURE N/A. Financial Impact. Impact.

This report is general in nature and not technically exhaustive.

EDISON. One Story, 3 Bedrooms, 2 Baths, Den & 2 Car Garage ELEVATION C ELEVATION D DRHORTON.COM. artist s concept.

Home Inspection Report

Property Condition Assessment

Choice Home Inspection Services, Inc.

CERTIFICATE of OCCUPANCY APPLICATION RESIDENTIAL

My Home Was Built In What Can I Expect To See On My Report?

Home Inspection Report Report Number: For The Property Located On:

Toronto Community Housing Executive Summary 2016/2017. BCA Report. Sample House High FCI

Project #1139 Budget #82. $ Budgeted $ Billed to Date $ Paid to Date $ Due 210, , , ,158.50

Integrity Home Inspection & Testing, LLC

Property Inspection Report

Your Company Name Goes Here. Your Company Name Goes Here

Standard Home Inspection Report

Premium Home Inspections. Inspection Report. Please read your report thoroughly!

Close-Up Home Inspection Home Inspection Report

Seal Harbor Development 1 Nagog Park Acton, MA 01720

Homes at Pine Ridge - NEW CONSTRUCTION SPECS

Missouri Housing Development Commission HeRO Inspection Form Revised 07/01/2015

Client: Address: Property Description: (3) story townhouse Property age/ size: 2,781 s.f., built 2007 per listing Occupancy Status: Vacant

Checklist #1 Questions to Ask Real Estate Agents

PROPERTY INSPECTION REPORT - Example

THE RESTORE LOUISIANA REIMBURSEMENT ESTIMATE

House2 Home Economy Inspection

Highland Grove. Westfield Collection Everything s Included Standard Features ( STARTS)

A1-Inspections. Building Inspection Report. (Div of Canada Inc.) Inspection Date: Prepared For: Report Sample

Legacy Home Inspections

Inspection Report. Sample House. Property Address: 310 Inspection Road Hometown FL. HousePro Inspection Services

PROPERTY INSPECTION REPORT

Building Inspection Report

Clients Name 123 Pleasant Valley Drive Any Town, OH 00000

INSPECTION CONNECTION, INC.

First Choice Inspections

BASEMENT FINISH CONSTRUCTION PLANS REFERENCE: 2015 INTERNATIONAL RESIDENTIAL CODE. PERMITS

Homeowner electrical wiring guide. Including the 2015 Canadian Electrical Code amendments

Atlas Property Inspections, LLC

BASEMENT FINISH PERMIT AND BUILDING CODE REQUIREMENTS (REVISED 3/6/2018)

SANDTOWN CROSSING PROFESSIONAL OFFICE PARK Atlanta, GA

Throughout this report where the age of roofs or other items are stated the age shown is approximate.

Property Inspection Report

HOME INSPECTION REPORT

The Oaks at Powers Ferry. A Townhome Community

Timber Trail Plan LOT BEDROOMS 4.5 BATHROOMS 2,974 FT 2 Land/Home Package OFFERED BY: SUNRIVER REALTY LINDA DORR, BROKER

The Inspection Process. Waxhaw N.C.

Woodshire Village Estates

Beneficial. Home Inspections. Your Home Inspection Report. John Doe. Customer Name - 02/30/2002. Inspection Date Sample Drive Inspection TX

Phone: Fax: Inspection Report

RISK Assessment Report. Office Building. Burbank, CA 91506

Healthy Homes Provisions of Lansing, Michigan Ordinances Extracted from by National Center for Healthy Housing

Transcription:

Cover Page Inspection press Property Inspection Report 33333 Inspection prepared for: Alejandro and Alejandra Perez Date of Inspection: 10/14/2015 Time: 2PM Age of Home: 2006 Size: 6,994 SF Weather: Hot! Inspection performed by: Chet Peterman HI-8110 Inspector: Andy Mazo License # HI2325 2005 Vista Parkway Suite 22, West Palm Beach, FL 33411 Phone: 561-742-7222 Email: Andy@Inspectionpress www.inspectionpress.com Inspectionpress Home Inspection Report

Inspection press Report Summary Report Summary The summary below consists of potentially significant findings. These findings can be a safety hazard, a deficiency requiring a major expenses to correct or items I would like to draw extra attention to. The summary is not a complete listing of all the findings in the report, and reflects the opinion of the inspector. Please review all of the pages of the report as the summary alone does not explain all the issues. All repairs must be done by a licensed &bonded trade or profession. I recommend obtaining a copy of all receipts, warranties and permits for the work done. Interior Areas Page 6 Item: 16 Window Condition One or more windows did not open/close/lock/latch properly, recommend repairs for enhanced security/safety to occupants. A spring kit is needed at the dining room window for proper operation. Bathroom Page 10 Item: 13 Showers Missing grout noted at the tile near the drain in the master bath. Recommend maintenance of grout and caulking to prevent water seepage. Page 11 Item: 17 Sinks Slow drain at sink. Recommend clearing. Some of the stoppers need to be adjusted for proper operation. Page 11 Item: 18 Toilets Tank base in the 1/2 bath is cracked/broken. This does not affect operation of the fixture. Kitchen Page 13 Item: 6 Microwave Inoperable at the time of inspection, Heat/AC Page 18 Item: 6 Refrigerant Lines Missing insulation at A/C unit. Garage Page 24 Item: 5 Rafters & Ceiling Garage drywall ceiling has minor cracking from drywall tape shrinkage and only needs to be monitored. Page 25 Item: 14 Garage Door's Reverse Status The 1 car door requires a great deal of resistance to trigger the auto-reverse mechanism. We recommend adjusting the opener for proper reverse tension. Roof Page 28 Item: 1 Roof Condition Some shingles / tiles damaged and/or loose. Recommend roofing contractor to evaluate. Page 32 Item: 7 Gutter One of the gutters needs to be inserted into the carry extension. Attic Page 32 Item: 2 Structure Evidence of past or present leaks, dry at time of the inspection. Monitor for leaks &/or have roofing contractor evaluate. Exterior Areas Page 37 Item: 2 Window Condition Some window screens damaged. 2. Some of the window areas need to be cleaned due to moisture based growth. Page 38 Item: 4 Eaves & Facia There are areas where the facia needs to be painted due to peeling or missing paint. Some of the areas appear to be stained from previous rains etc. There are also other areas that appear to have been repaired which most likely dates back to the builder. Grounds Page 1 of 46

Inspection press Page 39 Item: 1 Driveway and Potential Trip Hazard(s) at sidewalk; monitor / repair as Walkway Condition necessary. 2. There is a low area of pavers at the front entry. Page 40 Item: 3 Vegetation Observations Prune or remove any plants that are in contact or proximity to home to eliminate pathways of wood destroying insects. 2. The sod at the front yard needs to be replaced. Page 40 Item: 4 Gate Condition Gate is sagging - hinges appear to be corroded. 2. Some of the fence hardware is missing for appearance. Pool Page 43 Item: 4 Filter Recommend pool contractor to evaluate. There is an accumulation of water at the filter on the pad possibly meaning there is a slight leak. Page 44 Item: 6 Pool Heater Condition There is a pool heater that needs to be evaluated by a qualified tech during the pool service. Page 45 Item: 13 Timer The salt system is not operating properly as stated and needs further evaluation / repair. Page 46 Item: 16 Electrical There are wires loose / pulled at the conduit connection. This is a potential shock hazard. Page 2 of 46

Inspection press We appreciate the opportunity to conduct this inspection for you! Please carefully read your entire Inspection Report. Call us after you have reviewed your report, so we can go over any questions you may have. Remember, when the inspection is completed and the report is delivered, we are still available to you for any questions you may have, throughout the entire closing process. Properties being inspected do not "Pass" or "Fail. - The following report is based on an inspection of the visible portion of the structure; inspection may be limited by vegetation and possessions. Depending upon the age of the property, some items like GFI outlets may not be installed; this report will focus on safety and function, not current code. This report identifies specific noncode, non-cosmetic concerns that the inspector feels may need further investigation or repair. For your safety and liability purposes, we recommend that licensed contractors evaluate and repair any critical concerns and defects. Note that this report is a snapshot in time. We recommend that you or your representative carry out a final walk-through inspection immediately before closing to check the condition of the property, using this report as a guide. 1. Attendance 2. Home Type 3. Occupancy Inspection Details In Attendance: Client present Home Type: Single Family Home Occupancy: Occupied - Furnished: Heavy volume of personal and household items observed. The utilities were on at the time of inspection. Access to some items such as: electrical outlets/receptacles, windows, wall/floor surfaces, and cabinet interiors may be restricted by furniture or personal belongings. Any such items are excluded from this inspection report. Interior Areas The Interior section covers areas of the house that are not considered part of the Bathrooms, Bedrooms, Kitchen or areas covered elsewhere in the report. Interior areas usually consist of hallways, foyer, and other open areas. Within these areas the inspector is performing a visual inspection and will report visible damage, wear and tear, and moisture problems if seen. Personal items in the structure may prevent the inspector from viewing all areas on the interior. The inspector does not usually test for mold or other hazardous materials. A qualified expert should be consulted if you would like further testing. 1. Bar 2. Cabinets Page 3 of 46

Inspection press 3. Ceiling Fans 4. Closets 5. Door Bell 6. Doors 7. Electrical 8. Smoke Detectors 9. Stairs & Handrail Operated normally when tested, at time of inspection. The closet is in serviceable condition. Operated normally when tested. Double door entryway. Some outlets not accessible due to furniture and or stored personal items. Testing of smoke detectors is not included in this inspection. Pushing the "Test" button only verifies that there is power at the detector--either a battery or hard wired to the house power--and not the operational workings of the detector. The operational check is done by filling the sensor with smoke and is beyond the scope of this inspection. Battery operated smoke alarms should be checked routinely and the batteries changed frequently. Page 4 of 46

Inspection press 10. Window-Wall AC or Heat 11. Ceiling Condition 12. Patio Doors Materials: There are drywall ceilings noted. The hinged patio door was functional during the inspection. 13. Screen Doors 14. Wall Condition 15. Fireplace Materials: Drywall walls noted. Some areas not accessible due to stored personal items. Materials: Living Room Have a gas fireplace professional service/evaluate fireplace before operating. Page 5 of 46

Inspection press 16. Window Condition Materials: Aluminum framed single hung window noted. Insulated glass noted. One or more windows did not open/close/lock/latch properly, recommend repairs for enhanced security/safety to occupants. A spring kit is needed at the dining room window for proper operation. Bedrooms The main area of inspection in the bedrooms is the structural system. This means that all walls, ceilings and floors will be inspected. Doors and windows will also be investigated for damage and normal operation. Personal items in the bedroom may prevent all areas to be inspected as the inspector will not move personal items. 1. Locations 2. Cabinets Page 6 of 46

Inspection press 3. Ceiling Fans 4. Closets 5. Doors 6. Electrical Operated normally when tested, at time of inspection. The closet is in serviceable condition. Double door entryway. Some outlets not accessible due to furniture and or stored personal items. 7. Fireplace 8. Floor Condition 9. Smoke Detectors 10. Wall Condition 11. Window-Wall AC or Heat 12. Window Condition Materials: Drywall walls noted. Some areas not accessible due to stored personal items. Materials: Aluminum framed single hung window noted. Insulated glass noted. 13. Ceiling Condition 14. Patio Doors Materials: There are drywall ceilings noted. The hinged patio door was functional during the inspection. Page 7 of 46

Inspection press 15. Screen Doors Bathroom Bathrooms can consist of many features from jacuzzi tubs and showers to toilets and bidets. Because of all the plumbing involved it is an important area of the house to look over. Moisture in the air and leaks can cause mildew, wallpaper and paint to peel, and other problems. The home inspector will identify as many issues as possible but some problems may be undetectable due to problems within the walls or under the flooring.. 1. Locations 2. Cabinets 3. Ceiling Condition 4. Counters Materials: There are drywall ceilings noted. Granite tops noted. 5. Doors 6. Electrical 7. GFCI 8. Exhaust Fan 9. Floor Condition GFCI tested and functioned properly. The bath fan was operated and no issues were found. Materials: Ceramic tile is noted. Page 8 of 46

Inspection press 10. Heating 11. Mirrors Central heating and cooling noted in this room. At the time of the inspection, all appeared to be functioning and in serviceable condition. 12. Plumbing Page 9 of 46

Inspection press 13. Showers Missing grout noted at the tile near the drain in the master bath. Recommend maintenance of grout and caulking to prevent water seepage. 14. Shower Walls 15. Bath Tubs 16. Enclosure Ceramic tile noted. Whirlpool tub observed and stated to be in working condition. The shower enclosure was functional at the time of the inspection. Page 10 of 46

Inspection press 17. Sinks Slow drain at sink. Recommend clearing. Some of the stoppers need to be adjusted for proper operation. 18. Toilets Tank base in the 1/2 bath is cracked/broken. This does not affect operation of the fixture. 19. Window Condition Materials: Aluminum framed fixed window noted. Insulated glass noted. Kitchen The kitchen is used for food preparation and often for entertainment. Kitchens typically include a stove, dishwasher, sink and other appliances. Page 11 of 46

Inspection press 1. Cabinets No deficiencies observed. 2. Counters 3. Dishwasher Granite tops noted. Operated. 4. Doors 5. Garbage Disposal Operated - appeared functional at time of inspection. Page 12 of 46

Inspection press 6. Microwave 7. Cook top condition Built-in microwave ovens are tested using normal operating controls. Unit was tested and appeared to be serviceable at time of inspection. Leak and/or efficiency testing is beyond the scope of this inspection. Inoperable at the time of inspection, Gas cook top noted. 8. Oven & Range Oven: gas burners 9. Sinks 10. Drinking Fountain 11. Spray Wand 12. Hot Water Dispenser 13. Soap Dispenser Page 13 of 46

Inspection press 14. Trash Compactor 15. Vent Condition Materials: Exterior Vented 16. Window Condition 17. Floor Condition 18. Plumbing 19. Ceiling Condition Materials: There are drywall ceilings noted. 20. Patio Doors 21. Screen Doors Page 14 of 46

Inspection press 22. Electrical 23. GFCI 24. Wall Condition GFCI tested and functioned properly. Materials: Drywall walls noted. 1. Locations Laundry 2. Cabinets No deficiencies observed. 3. Counters 4. Dryer Vent Page 15 of 46

Inspection press 5. Electrical 6. GFCI 7. Exhaust Fan 8. Gas Valves 9. Wash Basin Page 16 of 46

Inspection press 10. Floor Condition 11. Plumbing Some not accessible. 12. Wall Condition 13. Ceiling Condition Materials: Drywall walls noted. Some areas not accessible due to stored personal items. Materials: There are drywall ceilings noted. 14. Doors 15. Window Condition Heat/AC The heating, ventilation, and air conditioning and cooling system (often referred to as HVAC) is the climate control system for the structure. The goal of these systems is to keep the occupants at a comfortable level while maintaining indoor air quality, ventilation while keeping maintenance costs at a minimum. The HVAC system is usually powered by electricity and natural gas, but can also be powered by other sources such as butane, oil, propane, solar panels, or wood. The inspector will usually test the heating and air conditioner using the thermostat or other controls. For a more thorough investigation of the system please contact a licensed HVAC service person. Page 17 of 46

Inspection press 1. Heater Condition 2. Heater Base Materials: The furnace is located in the hall closet The furnace is located in the attic Materials: The home has a split system. 3. Enclosure 4. Venting 5. Gas Valves 6. Refrigerant Lines Missing insulation at A/C unit. 7. AC Compress Condition Compressor Type: Electric Location: The compressor is located on the exterior north. The compressor is located on the exterior south. Appeared functional at the time of inspection. The typical temperature differential split between supply and return air in an air conditioner of this type is 15-20 degrees F. This system responded and achieved an average acceptable differential temperature of 16-18 degrees F between the four systems. Annual HVAC service contract is recommended. Page 18 of 46

Inspection press 8. Air Supply The return air supply system appears to be functional. Page 19 of 46

Inspection press 9. Registers Page 20 of 46

Inspection press 10. Filters 11. Thermostats MAINTENANCE: The air filter(s) should be inspected at least monthly and cleaned or replaced as required. There are two types of filters commonly used: (1) Washable filters, (constructed of aluminum mesh, foam, or reinforced fibers) these may be cleaned by soaking in mild detergent and rising with water. Or (2) Fiberglass disposable filters that must be REPLACED before they become clogged. Remember that dirty filters are the most common cause of inadequate heating or cooling performance. Functional at the time of inspection. Thermostats are not checked for calibration or timed functions. 1. Base Water Heater 2. Heater Enclosure 3. Combusion 4. Venting Page 21 of 46

Inspection press 5. Water Heater Condition Heater Type: Electric Location: The heater is located in the garage. Tank appears to be in satisfactory condition -- no concerns. 6. TPRV Appears to be in satisfactory condition -- no concerns. 7. Number Of Gallons 119 gallons 8. Gas Valve Page 22 of 46

Inspection press 9. Plumbing Materials: Copper No deficiencies observed at the visible portions of the supply piping. 10. Overflow Condition 11. Strapping 1. Roof Condition 2. Walls 3. Anchor Bolts 4. Floor Condition Garage Materials: Roofing is the same as main structure. Materials: Concrete tiles noted. No major system safety or function concerns noted at time of inspection. The anchor bolts were not visible. Materials: Bare concrete floors noted. Page 23 of 46

Inspection press 5. Rafters & Ceiling Garage drywall ceiling has minor cracking from drywall tape shrinkage and only needs to be monitored. 6. Electrical 7. GFCI 8. 240 Volt 9. Exterior Door 10. Fire Door 11. Garage Door Condition No deficiencies observed. Page 24 of 46

Inspection press 12. Garage Door Parts The garage door appeared functional during the inspection. 13. Garage Opener Status Chain drive opener noted. 14. Garage Door's Reverse Status The 1 car door requires a great deal of resistance to trigger the autoreverse mechanism. We recommend adjusting the opener for proper reverse tension. 15. Ventilation Under eave soffit inlet vents noted. Page 25 of 46

Inspection press 16. Vent Screens Vent screens noted as functional. 17. Cabinets 18. Counters 19. Wash Basin 1. Electrical Panel Electrical Location: Panel box located in garage. No major system safety or function concerns noted at time of inspection at main panel box. Page 26 of 46

Inspection press 2. Main Amp Breaker 150 amp 3. Breakers in off position 0 4. Cable Feeds 5. Breakers 6. Fuses There is an underground service lateral noted. Materials: Copper armor sheathed cable noted. All of the circuit breakers appeared serviceable. Page 27 of 46

Inspection press 1. Roof Condition Roof Materials: Inspected from ladder. Roof was visually inspected from accessible points on the interior and/or exterior. If a roof is too high, is too steep, is wet, or is composed of materials which can be damaged if walked upon, the roof is not mounted. Therefore, client is advised that this is a limited review and a licensed roofer should be contacted if a more detailed report is desired. Materials: Concrete tiles noted. Rolled roofing noted. Some shingles / tiles damaged and/or loose. Recommend roofing contractor to evaluate. Page 28 of 46

Inspection press Page 29 of 46

Inspection press Page 30 of 46

Inspection press 2. Flashing 3. Chimney No major system safety or function concerns noted at time of inspection. 4. Sky Lights 5. Spark Arrestor 6. Vent Caps Page 31 of 46

Inspection press 7. Gutter One of the gutters needs to be inserted into the carry extension. 1. Access 2. Structure Bedroom Closet. Garage ceiling. Attic Evidence of past or present leaks, dry at time of the inspection. Monitor for leaks &/or have roofing contractor evaluate. Page 32 of 46

Inspection press 3. Ventilation 4. Vent Screens 5. Duct Work Under eave soffit inlet vents noted. Vent screens noted as functional. See HVAC page. Page 33 of 46

Inspection press 6. Electrical Most areas not accessible due to insulation. Page 34 of 46

Inspection press 7. Attic Plumbing 8. Insulation Condition Materials: Fiberglass batts with kraft paper facing noted. Depth: Insulation averages about 8-10 inches in depth Page 35 of 46

Inspection press 9. Chimney 10. Exhaust Vent Functional. Page 36 of 46

Inspection press 1. Doors 2. Window Condition Exterior Areas Appeared in functional and in satisfactory condition, at time of inspection. Some window screens damaged. 2. Some of the window areas need to be cleaned due to moisture based growth. Page 37 of 46

Inspection press 3. Siding Condition 4. Eaves & Facia Materials: Stucco noted. There are areas where the facia needs to be painted due to peeling or missing paint. Some of the areas appear to be stained from previous rains etc. There are also other areas that appear to have been repaired which most likely dates back to the builder. Page 38 of 46

Inspection press 5. Exterior Paint Suggest caulking around doors and windows as necessary. 6. Stucco Grounds 1. Driveway and Walkway Condition Materials: Block / Brick sidewalk noted. Potential Trip Hazard(s) at sidewalk; monitor / repair as necessary. 2. There is a low area of pavers at the front entry. 2. Grading Page 39 of 46

Inspection press 3. Vegetation Observations Prune or remove any plants that are in contact or proximity to home to eliminate pathways of wood destroying insects. 2. The sod at the front yard needs to be replaced. 4. Gate Condition Materials: Plastic Fences and gates are NOT INCLUDED as part of a home inspection. Recommend confirming that all fences and gates are in serviceable condition before the close of escrow. Gate is sagging - hinges appear to be corroded. 2. Some of the fence hardware is missing for appearance. 5. Patio and Porch Deck Page 40 of 46

Inspection press 6. Stairs & Handrail 7. Grounds Electrical 8. GFCI GFCI: Ground Fault Circuit interrupter. 9. Main Gas Valve Condition Materials: East side. Meter located at exterior. All gas appliances have cut-off valves in line at each unit. No gas odors detected. Page 41 of 46

Inspection press 10. Plumbing Materials: Copper piping noted. PVC piping noted. 11. Exterior Faucet Condition Location: East side of house. 12. Balcony 13. Patio Enclosure Appears in satisfactory and functional condition with normal wear for its age. Appears to be sound structure. 14. Patio and Porch Condition Materials: The patio/porch roof is the same as main structure. 15. Fence Condition 16. Sprinklers The inspector could not locate the zone valve box. Consult with the seller for its location. Pool Page 42 of 46

Inspection press 1. Air Booster Pump 2. Deck Condition Materials: n/a see grounds page for material type. Appears in satisfactory and functional condition with normal wear for its age. Appears to be sound structure. 3. Gate & Fence Condition Materials: See grounds page. Gate did not self latch. 4. Filter Recommend pool contractor to evaluate. There is an accumulation of water at the filter on the pad possibly meaning there is a slight leak. Page 43 of 46

Inspection press 5. Skimmer and Basket Functional. 6. Pool Heater Condition Materials: Gas. There is a pool heater that needs to be evaluated by a qualified tech during the pool service. 7. Lights 8. Pressure Gauge Present on filter housing. Page 44 of 46

Inspection press 9. Pumps 10. Jets 11. Structure Condition 12. Tile 13. Timer The salt system is not operating properly as stated and needs further evaluation / repair. Page 45 of 46

Inspection press 14. Water Condition 15. Water Fill Unit 16. Electrical There are wires loose / pulled at the conduit connection. This is a potential shock hazard. 17. GFCI GFCI tested and functioned properly. Page 46 of 46