Full scale experimental performance assessment of a prefabricated timber panel for the energy retrofitting of multi-rise buildings

Similar documents
Arcisstrasse München. GERMANY

Available online at ScienceDirect. Energy Procedia 78 (2015 )

Thermal insulation performance of reflective foils in floor cavities - Hot box measurements and calculations

Design, Fabrication and Experimental Study of a Novel Loopheat-pipe based Solar Thermal Facade Water Heating System

7. MATERIALS AND TECHNICAL INVESTIGATION

DEVELOMENT AND EVALUATION OF ENVIRONMENTALLY FRIENDLY FAÇADE ELEMENTS FOR DEEP RETROFITTING OF BUILDINGS

IMPACT OF COLUMNS AND BEAMS ON THE THERMAL RESISTANCE OF THE BUILDING ENVELOPE

Retrofit of an historical building toward NZEB

ASM MARKET RESEARCH AND ANALYSIS CENTRE

Thermal Performance of Retrofitted Envelopes with Internal Insulation: A Comparative Analysis

Xtratherm Thin-R Partial Fill Cavity Wall Board (XT/CW Grade)

Available online at ScienceDirect. Energy Procedia 91 (2016 )

Available online at ScienceDirect. Energy Procedia 91 (2016 ) 20 26

Development for Sustainable Construction System (Rapid Walls) in Egypt Using Nanotechnology

Available online at ScienceDirect. Energy Procedia 78 (2015 )

Observation of Liquid-filled Window without Presence of Liquid in Test Chamber

EasylationWall. External Wall Insulation System. bringing european innovation

Available online at ScienceDirect. Energy Procedia 48 (2014 )

Passive Houses Worlswide: International Developments

Benefits from energy related building renovation beyond costs, energy and emissions

SUMMER THERMAL COMFORT IN TYPICAL FRENCH RESIDENTIAL BUILDINGS: IMPACT ASSESSMENT OF BUILDING ENVELOPE INSULATION ENHANCEMENT

CHAPTER 3: Modern Methods of Construction (MMC)

THERMAL MASS IMPACT ON ENERGY PERFORMANCE OF A LOW, MEDIUM AND HEAVY MASS BUILDING IN BELGRADE

Building Design Data

Available online at ScienceDirect. Energy Procedia 78 (2015 ) th International Building Physics Conference, IBPC 2015

IEA Annex 58: Full-scale Empirical Validation of Detailed Thermal Simulation Programs

Computational and the real energy performance of a single-family residential building in Poland an attempt to compare: a case study

ScienceDirect. Appraising the effect of the primary systems on the cost optimal design of nzeb: A case study in two different climates

HP Partial Fill. Robust, long-lasting protection

Glazed photovoltaic-thermal component for building envelope structures

Available online at ScienceDirect. Energy Procedia 78 (2015 )

Energy consumption and thermal comfort in a passive house built in Romania

Memo. ArcelorMittal Liège Research and Development. Mrs. Baddoo. GIORGIA CAROLI - Marie Descamps. Date 16/10/2007 Pages 1 of 12 Subject ROBUST wp1,2

Available online at ScienceDirect. Energy Procedia 78 (2015 ) th International Building Physics Conference, IBPC 2015

Multi-layer Insulation Blanket for Walls

ScienceDirect. Influence of the balcony glazing construction on thermal comfort of apartments in retrofitted large panel buildings

Module Approved construction details

Impact of Insulated Concrete Curb on Concrete Balcony Slab

Available online at ScienceDirect. Procedia Engineering 146 (2016 ) 60 68

PassiveDesign.org. Passive Construction. Name:...

Zero Carbon Building Energy Modelling Guidelines. October 31, 2017

ENERGY EFFICIENT BUILDING STRUCTURE. ...more than brick.

Insulation options. Calculating U-Values

Thermal Laminate Board.

Project Description. Projected build start date 01 Mar 2010 Projected date of occupation 31 May Aberdare, Rhondda Cynon Taff, Wales

THERMAL MASS IMPACT ON ENERGY PERFORMANCE OF A LOW, MEDIUM, AND HEAVY MASS BUILDING IN BELGRADE

HOW CURRENT TRENDS IN THE DESIGN OF FACADES INFLUENCE THE FUNCTIONAL QUALITY OF INTERIOR SPACES

Nearly zero energy building renovation, the EU-GUGLE project Javier Llorente Yoldi

External Wall Insulation Systems GUARANTEED TO PERFORM!

ENERGY EFFICIENCY OF RESIDENTIAL BUILDINGS IN SERBIA

RAINSCREEN DUO SLAB. Non-combustible thermal insulation

Superior Performance PIR Insulation XO/FB. Insulaton for Steel & Timber Frame. Walls 12/4956

Xtratherm Thin-R Thermal Liner (XT/TL Grade)

Available online at ScienceDirect. Energy Procedia 78 (2015 )

CEN/TC 89 - Thermal performance of buildings and building components

ZEMedS: Case studies

PASSIVE HOUSE OBJECT DOCUMENTATION

This document is a preview generated by EVS

EcoHome-Insulation.com. Aluminium Foil Bubble Insulation. General Purpose Insulation. Dry Lining. Cavity Wall. Insulation System.

In general, passive-solar components can be described by the U-value (heat loss coefficient) and

FEDERATION TOWER MOSCOW DIFFERENT ROOM CLIMATES UNDER ONE ROOF

Available online at ScienceDirect. Procedia Engineering 117 (2015 )

Impacts of energy retrofits on hygrothermal behavior of Finnish multi-family buildings

Energy Audit of two Apartment Buildings in Cagliari using Energy Simulation

EFFESUS SYMPOSIUM ENERGY EFFICIENCY FOR EU HISTORIC DISTRICTS SUSTAINABILITY

Bruck an der Mur. Project summary. Energy concept: Background for the renovation reasons

THERMAL MASS CHAPTER 6. Understanding thermal mass. Seasonal effects of thermal mass

MASTER THESIS FACULTY OF INDUSTRIAL ENGINEERING CAMPUS GENT

A Quality Assurance System for Improvement of Indoor Environment and Energy Use when Retrofitting Residential Houses

A Protocol to Determine the Performance of South Facing Double Glass Façade System


EFFESUS SYMPOSIUM ENERGY EFFICIENCY FOR EU HISTORIC DISTRICTS SUSTAINABILITY

Thermablok Aerogel Insulation Blanket Thermablok Aerogel Blanket

INVESTIGATION OF UNSTEADY THERMAL RESPONSE CHARACTERISTICS OF HOLLOW BRICKS EXPOSED TO SINUSOIDAL SOLAR THERMAL EXCITATION

SOLAR PHOTOVOLTAIC ASI GLASS E. ASI Glass. Integrated Architecture Powered by the Sun

Available online at ScienceDirect. Energy Procedia 111 (2017 )

Apartment building Sodastraße 40 in Ludwigshafen, DE

DICTATOR Lift Shaft System

Envelope Optimization

BUILDING DESIGN AND THERMAL INERTIA: WHEN, WHY, WHERE

Flexibility in typology, technology, construction and performances: an innovative approach for an open construction kit

GypLyner UNIVERSAL Metal framed wall lining system

BULGARIAN LEGISLATION IN THE FIELD OF ENERGY EFFICIENCY HEAT RETENTION AND ENERGY CERTIFICATION OF NEW AND EXISTING BUILDINGS


A STUDY ON DESIGN OPTIMIZATION OF A NEAR NET-ZERO ENERGY HOUSE

Best Practice Recommendations for Wall Retrofit on the Two-Story Flexible Research Platform (FRP) at Oak Ridge National Laboratory (ORNL).

SCHWAN & SPEHR energy management

Energy Efficient Buildings in Germany An Introduction

Available online at ScienceDirect. Energy Procedia 78 (2015 ) th International Building Physics Conference, IBPC 2015

Engineered Timber Systems AN INTRODUCTION. Low Energy Low Carbon Buildings. CI/SfB (2-) Rj7 - Thirteenth Issue September 2017

Energy performance analysis of residential buildings in Bari, in the South of Italy

IBP FRAUNHOFER INSTITUTE FOR BUILDING PHYSICS IBP ENERGY SYSTEMS

Data Sheet 3611 Englisch

Available online at ScienceDirect. Energy Procedia 48 (2014 )

Available online at ScienceDirect. Energy Procedia 78 (2015 ) th International Building Physics Conference, IBPC 2015

Local Temperature Measurements on Full-Size Systems in the Laboratory: Insight into the Extent of Thermal Bridges in Building Envelope Components

STEADY STATE AND DYNAMIC THERMOPHYSICAL PARAMETERS OF TRANSPARENT BUILDING COMPONENTS

The impact of different insulation options on the life cycle energy demands of a hypothetical residential building.

Following CEN Mandate M/480 [1] a comprehensive

Transcription:

Available online at www.sciencedirect.com ScienceDirect Energy Procedia 122 (2017) 3 8 www.elsevier.com/locate/procedia CISBAT 2017 International Conference Future Buildings & Districts Energy Efficiency from Nano to Urban Scale, CISBAT 2017 6-8 September 2017, Lausanne, Switzerland Full scale experimental performance assessment of a prefabricated timber panel for the energy retrofitting of multi-rise buildings Roberto Garay Martinez a *, Josu Benito Ayucar a, Beñat Arregi Goikolea a a Tecnalia, Sustainable Construction Division Parque Tecnológico de Bizkaia, C/Geldo s/n, Edificio 700, E-48160 Derio Bizkaia Spain +34 667 178 958 roberto.garay@tecnalia.com Abstract A prefabricated timber façade system is presented for the energy retrofitting of buildings. Large panel dimensions facilitate the installation of this system, with reduced disturbance to building users and increased overall quality in terms of thermal bridge mitigation and air tightness of architectural junctions. A full scale proof of concept test is performed, where several prefabricated timber panels were installed over a pre-existing brick façade, their junctions tested, and the differential thermal performance of the system is evaluated. It is concluded that the overall thermal performance of the system is satisfactory in terms of overall U- value, thermal bridge coefficient and, temperature factor. Furthermore, and based on experimentally obtained data, a dynamic characterization of the harmonic thermal response of the system is performed. 2017 The Authors. Published by Elsevier Ltd. Peer-review under responsibility of the scientific committee of the CISBAT 2017 International Conference Future Buildings & Districts Energy Efficiency from Nano to Urban Scale Keywords: Thermal Performance; Timber; Building Envelope; Retrofitting; Experimental Assessment; Prefabrication; * Corresponding author. Tel.: +34 946 430 069; fax: +34 946 460 900. E-mail address: roberto.garay@tecnalia.com 1876-6102 2017 The Authors. Published by Elsevier Ltd. Peer-review under responsibility of the scientific committee of the CISBAT 2017 International Conference Future Buildings & Districts Energy Efficiency from Nano to Urban Scale 10.1016/j.egypro.2017.07.288

4 Roberto Garay Martinez et al. / Energy Procedia 122 (2017) 3 8 1. Introduction Building envelopes are the physical interface between indoor and outdoor conditions, and their response to variations on these conditions such as temperature oscillations and incidence of solar radiation, substantially defines the heat dynamics of buildings. Roofs, façades, and glazed areas are responsible for over 60% of heat losses in conventional buildings. Considering the large building stock and demographic projections in Europe, the quest in energy performance improvement is related to the already existing and ageing building stock. With modern building energy codes in Europe dating back to the 1970s, there has been a steady development and deployment of a variety of thermal insulation systems, such as external thermal insulation systems (ETICs) and ventilated façade systems. With similar approaches to many other construction processes, building energy retrofits are personnel intensive processes, where raw materials such as insulation, reinforcement meshes, plasters, etc. are delivered on site, and manually installed by crafts. Although increasing care is paid to details in the construction process, large discrepancies are found between design and as-built performance of buildings, and its thermal insulation systems. Many sources are identified for the gap in energy performance, one of the main being poor workmanship. In this paper an industrialized timber panel is proposed for the energy retrofitting of building envelopes. This panelized system is manufactured in a factory and delivered on-site. Factory production controls minimize performance loss due to poor workmanship. Once delivered on-site, panels are anchored to structural elements in the façade, and junctions are executed in a standardized way. Within the development of the BERTIM timber façade, a full scale test was constructed comprising a 2-store-high setup, in order to ensure constructability of the system, test the production-transport-installation sequence, and onsite assess the thermal performance of the system. This setup was constructed in the KUBIK by Tecnalia test facility, over a pre-existing brick façade. Brick façades comprise the majority of the building stock in many countries such as Spain, and this particular façade was originally constructed according to thermal performance levels in the 1970s. The building envelope retrofit was sized in order to guarantee a large reduction of the thermal transmittance of the wall, ensuring compatibility of the wall with current energy performance standards. The presented study shows the thermal performance of this system by means of numerical and experimental thermal assessments, and its differential thermal performance assessment when compared to the existing brick façade. 2. The BERTIM timber panel system and industrialized approach to building energy retrofits BERTIM [1] proposes a building energy retrofit process focused on the deployment of high performance, minimally intrusive industrialized envelope systems. The Timber-based system is manufactured in large prefabricated envelope sections which are then delivered and installed with minimal on-site works. In its conception, industrialized Timber-based panels with variable dimensions are allowed. This allows adaptation to variable floor heights, modulation of windows, etc. In some cases, panels spanning over several floor are possible. With this approach specific panel costs per surface are reduced, and on-site installation works facilitated. The BERTIM system comprises not only envelope insulation elements, but also allows integrating ducts and pipes within the system to allow for the retrofitting of building HVAC systems with minimal intrusion. In the following figures, the composition of BERTIM panels for insulation and HVAC integration are presented.

Roberto Garay Martinez et al. / Energy Procedia 122 (2017) 3 8 5 (a) (b) Fig. 1. Composition of the BERTIM timber-based panels. (a) Thermal insulation panels and (b) panels with HVAC systems embedded. 3. Experimental setup The test was carried out over a portion of the west-facing façade of the KUBIK test facility in Derio, Spain (43 17 N 2 52'W). KUBIK by Tecnalia [2] is a full scale experimental infrastructure focused on research and development of new energy efficient products and systems. It has a total floor area of 500 m² distributed over basement, ground floor and two upper levels. The main distinctive feature of KUBIK is its capacity to create realistic scenarios for the quantitative determination of energy efficiency and energy savings resulting from the interplay of construction solutions, intelligent management of HVAC and lighting systems, and non-renewable and renewable energy sources. The experimental setup was constructed over a pre-existing brick façade which was thermally characterized within [3]. This façade has already been use in the past to test two thermal insulation systems [3, 4], with various approaches. In [3] stochastic methodologies were used to assess the dynamic thermal performance of the existing wall, and an external thermal insulation system. In [4], steady state methods [5] were used to obtain the differential thermal performance of the wall due to the addition of a prefabricated, lightweight concrete insulation system. In the particular case of the BERTIM panel system, the setup was designed to cover most of the complexities of a real-case installation of the BERTIM system. Two main areas were differentiated in the test, where different types of panels were installed: (1) Envelope insulation panels and (2) HVAC ducting panels. The architectural definition ensured that all types of junctions (vertical, horizontal, between different panel types ), and panel sizes (one floor or two floor modules) were prescribed, in order to identify any possible failure in the design of the system. Due to the limited extension of this paper, the thermal performance of HVAC ducting panels is not performed. The assessment is focused in Envelope insulation panels.

6 Roberto Garay Martinez et al. / Energy Procedia 122 (2017) 3 8 (a) (b) Fig. 2. Test area at first floor of west-facing façade in KUBIK facility: (a) original brick wall before installation; (b) BERTIM prototype installed. 4. Pre- and Post-retrofit configuration and thermal performance of the wall The pre-retrofit configuration of the wall consisted on a cavity wall consisting of two ceramic brick masonry layers, with an internal plaster render. Table 1 defines the characteristics of each of the layers in this wall, along with its total U-value according to numerical assessment methods [6] and experimentation carried out in [3]. Table 1: Characteristics of the pre-retrofit status of the façade Thickness Thermal resistance Internal thermal resistance Thermal transmittance [m] r [m2k/w] r ss [m2k/w] U [W/m2K] Outside 0.04 Brick wall 0.11 0.21 0.21 Air gap 0.18 0.18 Brick wall 0.70 0.16 0.16 Internal render 0.015 0.019 0.019 Inside 0.13 0.74 0.57 1.35 The dimensions of each of the layers in the timber insulation system were particularized for the test in order to achieve a threshold energy performance. Table 2 presents these characteristics, and its expected thermal performance. Table 2: Characteristics of the post-retrofit status of the façade Thermal Thermal Thickness Thermal conductivity resistance transmittance [m] [W/mK] r [m2k/w] U [W/m2K] Outside 0.04 Rockwool 0.14 0.035 4.00 OSB 0.012 0.20 0.06 Compressible Rockwool 0.02 0.035 0.57 Original wall 0.295 0.53 Inside 0.13 5.33 0.19

Roberto Garay Martinez et al. / Energy Procedia 122 (2017) 3 8 7 5. Methodology The experimental set-up and the data analysis were designed to obtain the thermal resistance of (a) the whole wall integrating the BERTIM solution and (b) the BERTIM component in itself. 5.1. Measurement method and materials Pt100 temperature sensors by Thermo Sensor GmbH (precision ± 0.1 C) and Phymeas heat flux sensors (precision ± 0.1 % of FSV) were used in the experiment, connected to a Beckhoff Automation PLC system, where data from measurements was recorded at 1 minute intervals. In order to gather the data required for obtaining thermal resistance values for the different layers of the component, the sensors were placed over relevant points of the assembly: Layer 1, internal surface of existing brick wall: temperature and heat flux sensors Layer 2, external surface of existing brick wall: temperature and heat flux sensors Layer 3, external surface of BERTIM panel: temperature sensor only These sensors give sufficient information for obtaining the following thermal resistance values: R 3-1, thermal resistance of the retrofitted wall R 3-2, thermal resistance of BERTIM panel R 2-1, thermal resistance of the original wall This arrangement was replicated along 3 measurement axes in different locations over the two-floor-high setup, in order to assess the variability of the thermal resistance due to installation defects and thermal stratification conditions. So as to exclude the effect of thermal bridges, these measurement axes were deliberately placed in an intermediate zone between floors. 5.2. Calculation of thermal resistance For one-dimensional heat transfer, thermal resistance is defined as the ratio of temperature difference and the heat flux between opposite faces of a material. The input variables (temperature and heat flux) vary over the course of the experiment. Despite a dominant daily cycle, changing weather conditions result in a high variability among different days. Therefore a normalised average method has been used to filter out heat storage effects, where the obtained data is aggregated in order to reduce dynamic oscillations. When carried over a long enough period of time, there is a convergence to an asymptotical value that is close to the steady-state value. 6. Results of the experimental campaign Minutely recorded data in the period from November 2016 to April 2017 was processed for this assessment. Results were obtained for each of the 3 measurement axes. In order to achieve a robust and stable surface-surface conductance value, the signals were processed by generated cumulated mean values of each of the signals. Quantitative results are portrayed in Table 3.

8 Roberto Garay Martinez et al. / Energy Procedia 122 (2017) 3 8 Table 3. Statistical distribution of experimental readings for temperature and heat flux density. Temperature [ C] Heat flux density [W/m²] T 1 T 2 T 3 q Maximum 28.94 26.1 48.95 7.96 Third quartile 26.09 25.24 16.51 3.42 Average 25.57 24.48 14.42 1.98 First quartile 25.06 23.81 10.54 1.56 Minimum 24.27 21.51 1.746 0.35 7. Conclusions and further work From the temperature and heat flux density values measured, thermal resistance values have been obtained for both the original wall and the BERTIM panel show an overall thermal resistance of the insulated assembly has been measured at 5.07 m²k/w. This resistance is a significant improvement from the value measured before insulation (0.53 m²k/w). The thermal resistance of the BERTIM panel has been measured at 2.47-4.08 m²k/w. Overall; the BRESAER system provides a 7x increase in the thermal resistance of the wall. The experiment presented in this paper has served as a proof of concept where thermal performance and construction process have been proven satisfactorily. Within the expected development of the BERTIM project, and considering its success in delivering a prefabricated system with thermal insulation properties, BERTIM will be scaled up and a full scale execution over a residential building in Charité-Sur-Loire, in France. Considering its approach to construction product development through phases (design, full scale proof-of-concept and final deployment in a demonstration building), BERTIM will substantially reduce risks of reduced performance by means of a stepwise mapping of design, with real-life performance. Thus it delivers a guaranteed performance to final users of the system. Acknowledgements This paper has been drafted thanks to the funding from the European Union s Horizon 2020 research and innovation programme under grant agreement No 636984. The content of this paper does not reflect the opinion of the European Union. References [1] BERTIM, Building energy renovation through timber prefabricated modules, EU h2020 GA nº636984, http://www.bertim.eu/ (2017/04/07) [2] Garay, R et Al, Energy efficiency achievements in 5 years through experimental research in KUBIK, 6th International Building Physics Conference, IBPC 2015, Torino, 2015 [3] Estudio de investigación sobre eficiencia energética y viabilidad de la aplicación de fachadas ventiladas en soluciones de rehabilitación, TECNALIA, ERAIKAL-12. [4] Garay, R. et Al. Experimental Thermal performance Assessment of a Prefabricated External Insulation System for Buildings Retrofitting, International Conference on Sustainable Synergies from Buildings to the Urban Scale, SBE16, Thessaloniki, 2016 [5] EN ISO 9869-1:2014 thermal insulation Building elements- In-situ measurements of thermal resistance and thermal transmittance Part 1: Heat Flow Meter Method [6] EN ISO 6946: 2007, Building Components And Building Elements - Thermal Resistance And Thermal Transmittance - Calculation Method