RESILIENT ACCESSORIES

Similar documents
RESILIENT PHOTOLUMINESCENT STAIR TREADS

CONDUCTIVE RESILIENT FLOORING

RESILIENT CORK TILE 3 PART SPECIFICATION #Z 624

B. Store products in dry spaces protected from the weather, with ambient temperatures maintained between 50 and 90 deg F (10 and 32 deg C).

ARCHITECTURAL GUIDE SPECIFICATIONS - DESCRIPTIVE

RESILIENT FLOORING: Hot and Heavy - Secoya

RESILIENT FLOORING: Select Step Wood

GUIDE SPECIFICATION

A. Drawings and general provisions of the Contract apply to this Section including all documentation provided in RFP#

GUIDE SPECIFICATION

SECTION RESILIENT STAIR TREADS CSI 3-PART SHORT-FORM GUIDE SPECIFICATION USE FOR OUTLINE OR DD SPECIFICATION ISSUES. EDIT TO SUIT PROJECT

SECTION RESILIENT SHEET FLOORING

NORTHWESTERN UNIVERSITY PROJECT NAME JOB # ISSUED: 03/29/2017

SECTION TERRAZZO FLOOR TILE

ARDEX GUIDE SPECIFICATION ARDEX MC RAPID One-Coat Moisture Control System For Concrete to Receive ARDEX Products

SECTION R CARPET PART 1 - GENERAL 1.1 SUMMARY

A. Section includes hydraulic-cement-based, polymer-modified, self-leveling underlayment for application below interior floor coverings.

1. Division 09 Section "Rough Carpentry."

ComforTech Cushioned Rubber Sheet Flooring

Suggested Specification for Tri-Patch Versatile Concrete Patching Compound

A. This Section includes resinous flooring systems with epoxy body coat(s).

SECTION SPRAY APPLIED FLOOR ADHESIVE

SECTION PREFINISHED FSC MAPLE FLOORING. This is a template: edit this specification carefully to suit specific project requirements.

B. Related Sections: 1. Division 07 Section "Joint Sealants" for sealing of expansion, contraction, control, and isolation joints in tile surfaces.

Chapter 2. Basic practices. Topics. 7 Basic practices. Notes. 2.5 Existing flooring and adhesive residue Job site conditions 8

Installation Guide LVP Glue Down

RESILIENT FLOORING

SECTION RESILIENT SHEET FLOORING

Advance NG (6mm) Technical Specification Sheet

Ecore Athletic Elevate BOUNCE 2 GUIDE SPECIFICATIONS Ecore

SECTION EPOXY TERRAZZO

SECTION RESINOUS MATRIX TERRAZZO FLOORING PART 1 - GENERAL 1.1 RELATED DOCUMENTS

GUIDE SPECIFICATIONS IN CSI FORMAT: RESILIENT FLOORING

SECTION HYDRAULIC CEMENT UNDERLAYMENT

ARDEX GUIDE SPECIFICATION ARDEX MRF Moisture-Resistant, Rapid-Drying, Skimcoat Patching Underlayment

DIVISION 9 - SECTION QTscu Re-bonded Recycled Rubber Impact Sound Insulation Patent No. RE 41,945

09651 RESILIENT SHEET FLOORING

SECTION and/or Resilient Sheet Flooring and/or Resilient Tile Flooring

SECTION EPOXY TERRAZZO

CONTRACT PAGE 1 OF 5

Click Refresh with In*Step Locking System

ECOfit Rolls GUIDE SPECIFICATIONS Ecore Commercial Flooring

HAWORTH PORCELAIN FLOORING SYSTEM CSI Specifications 03/29/2017. A. Concrete work and concrete floor sealer is specified in Section

1.2 Reference Standard: NOFMA - National Oak Flooring Manufacturers Association Grading Standards.

Specification and Installation

Construction Specification

FlexLok Adhesive Tabs for Carpet Tile

KOSTER AMERICAN CORPORATION

(Specifier Note: Aristech Surfaces LLC is the manufacturer of the Avonite brand

Technical Service. INSTALLATION INSTRUCTIONS FOR TARAFLEX SPORT PRODUCTS over Gypsum base Products. This document refers to the following products:

Harmoni (3 mm) Technical Specification Sheet

May 8, 2017 ADDENDUM #1. IFB Resin Floor System For Highway Department Central District Building

SECTION and/or Resilient Sheet Flooring and/or Resilient Tile Flooring

Product Width Thickness Installation direction Seam treatment. Taraflex Sport M Comfort Approximately mm + 5mm Same Heat Welded

LUXURY VINYL GENERAL INSTALLATION INSTRUCTIONS FOR LOCKING FLOORING

Product Guide Specification

Resilient and Wood Floor Covering Flatness Requires High Performance, Cementitious Self-Leveling Underlayment

ENGINEERED WATERPROOF FLOORING GENERAL INSTALLATION INSTRUCTIONS FOR VÄLINGE 2G LOCKING FLOORING

Luxury Vinyl Plank Installation Manual 2017

SECTION RESINOUS FLOORING or SECTION QUARTZ FLOORING

Vinyl Rx GUIDE SPECIFICATIONS Ecore Commercial

SECTION ARCHITECTURAL SPECIFICATIONS FOR INDOOR WOOD ATHLETIC FLOORING

IVC US Residential Installation Guide - Sheet Vinyl. Leading the Way

Custom Polishing Systems

Everlast Basic Rolls and Tiles GUIDE SPECIFICATIONS Ecore

System Specifications

ENGINEERED LUXURY VINYL GENERAL INSTALLATION INSTRUCTIONS FOR ANGLE-TO-ANGLE FLOORING

Commercial Resilient Sheet Flooring

FiberFloor Glueless and Full Spread Installation Instructions

SECTION ORNAMENTAL ALUMINUM RAILING. ** NOTE TO SPECIFIER ** Superior Aluminum Products, Inc.; Ornamental aluminum railing products.

B. Samples for Initial Selection: For each type of impact-resistant wall protection unit indicated.

RESILIENT TILE FLOORING

Acceptable Floor Substrates: Concrete, cured mortar bed, plywood, and backer board.

BENTLEY ELEMENTS COLLECTION LVT

Ecore Athletic Stacked Performance Collection Rolls and Interlocking Tiles GUIDE SPECIFICATIONS Ecore

Medi-Flex TRUE TM SHEET RUBBER INSTALLATION INSTRUCTIONS

SECTION MOISTURE RESISTANT/WATER-PROOF FLOORING ADHESIVE FOR CONCRETE SLABS

LAMINATE GENERAL INSTALLATION INSTRUCTIONS FOR DROP LOCK FLOORING

Wallflowers RUBBER WALL BASE

Section Polished Concrete Finishing. Vexcon

NEW HARMONI (3mm) Technical Specification Sheet

TILE TILE

SECTION PREFINISHED ENGINEERED WIDE-PLANK FSC OAK FLOORING

***************************************************************************************************************

1.02 REFERENCED DOCUMENTS

STAIR TREAD INSTALLATION

CONNOR Control XT Page 1

Signature Sports Flooring Installation Instructions. For SignaDeck Premium Rubber Tiles

SECTION POLYACRYLATE MODIFIED CEMENTITIOUS TERRAZZO FLOORING

Access Luxury Vinyl Flooring Installation Guidelines

CSI GUIDE Countertops

1. CONCRETE SUBFLOORS.SECTION a. Slab Depression: Equal to thickness of selected flooring (6, 8,10,12,13 or 14mm).

DO-IT-YOURSELF SELF ADHESIVE PLANK INSTALLATION

ARDEX GUIDE SPECIFICATION ARDEX K 521 Self-Leveling Concrete Topping with Aggregate Surface

9 RUBBER TRACK SURFACING (INDOOR APPLICATIONS) (FOR ALL SPORTFLEX, SUPER X AND MONDOTRACK PRODUCTS)

Scuba Seal Installation / Floor Care Instructions With Video Link

Specification Data -- RESILIENT TILE FLOORING

INSTALLATION INSTRUCTIONS FOR GERFLOR TARASAFE ULTRA VINYL SHEETGOODS

SECTION ULTRACOMPACT WALL FINISHES - THIN SET

UNDERLAYMENT INSTALLATION INSTRUCTIONS

Transcription:

INCLUDING COVE CAP, CHAIR RAIL, CORNER GUARD, TUB MOULDING, COVE FILLER STRIP AND SUBFLOOR LEVELER SYSTEM THIS DOCUMENT IS INTENDED AS A SUGGESTED GUIDE FOR CREATING, MODIFYING, OR EDITING YOUR CSI FORMATTED 3-PART ARCHITECTURAL GUIDE SPECIFICATIONS. JOHNSONITE WILL NOT BE LIABLE FOR ANY DAMAGES ARISING OUT OF THE USE OF ANY INFORMATION OR SPECIFICATIONS FOUND IN THIS DOCUMENT. ENSURE THAT YOU HAVE THE LATEST PUBLICATION FOR THIS SPECIFICATION. THE SPECIFIER OR DESIGNER IS RESPONSIBLE FOR PRODUCT SELECTION AND ACCURACY OF ALL PROJECT SPECIFICATIONS, INCLUDING ANY JOHNSONITE INFORMATION OR SPECIFICATIONS USED. PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 01 Specification Sections, apply to this Section. 1.2 SUMMARY A. Section Includes: 1. Resilient flooring accessories. 1.3 SUBMITTALS A. Product Data: For each type of product indicated. B. LEED Submittals: 1. Product Data for Credit EQ 4.1: For adhesives, including printed statement of VOC content and chemical components. C. Samples for Initial Selection: For each type of product indicated. March 2013 Page 1 of 9 Resilient Accessories 09.65.13.33

D. Samples for Verification: For each type of product indicated, in manufacturer's standard-size samples of each resilient product color, texture, and pattern required. E. Product Schedule: For resilient products. Use same designations indicated on Drawings. 1.4 QUALITY ASSURANCE A. Mockups: Provide resilient products with mockups specified in other Sections. 1.5 DELIVERY, STORAGE, AND HANDLING A. Store resilient products and installation materials in dry spaces protected from the weather, with ambient temperatures maintained within range recommended by Johnsonite, but not less than 55 deg F (13 deg C) or more than 85 deg F (29 deg C). 1.6 PROJECT CONDITIONS A. Install resilient products after other finishing operations, including painting, have been completed. B. Maintain ambient temperatures within range recommended by Johnsonite, but not less than 65 deg F (18 deg C) or more than 85 deg F (29 deg C) in spaces to receive resilient products during the following time periods: 1. 48 hours before installation. 2. During installation. 3. 48 hours after installation. C. Maintain the ambient relative humidity between 40% and 60% during installation. D. Until Substantial Completion, maintain ambient temperatures within range recommended by Johnsonite, but not less than 55 deg F (13 deg C) or more than 85 deg F (29 deg C). March 2013 Page 2 of 9 Resilient Accessories 09.65.13.33

PART 2 - PRODUCTS 2.1 RESILIENT MOULDING ACCESSORIES Manufacturer: Johnsonite, Inc. Phone (800) 899-8916 16910 Munn Road (440) 543-8916 Chagrin Falls, Ohio 44023 Tech: Ext 9297 Web: www.tarkettna.com Samples: Ext 9299 E-mail: info@johnsonite.com Fax: (440) 543-8920 ENVIRONMENTAL SUSTAINABILITY NOTES: Johnsonite Resilient Accessories Johnsonite offers a RESTART reclamation program for returning jobsite scrap 100% Recyclable Phthalate-free Contains at least 14% pre-consumer recycled materials SCS FloorScore Certified and meets California Specifications Section 01350 Johnsonite facilities are ISO 9001 and ISO 14001 Certified Possible LEED contributions for Resilient Accessories include MR:2, MR:4, MR:5 For all environmental sustainability information visit ecoscorecard on Johnsonite home page at www.tarkettna.com A. Cove Cap [cap for cove resilient floor covering] JOHNSONITE COVE CAPS specify Resilient cove cap with the following physical characteristics: a. Manufactured from a homogeneous composition of polyvinyl chloride (PVC). c. Cove Caps are to be 12 foot lengths per piece. d. Johnsonite offers a RESTART reclamation program for returning jobsite scrap e. 100% Recyclable f. Phthalate-free g. Contains at least 14% pre-consumer recycled materials h. SCS FloorScore Certified and meets California Specifications Section 01350 i. Johnsonite facilities are ISO 9001 and ISO 14001 Certified March 2013 Page 3 of 9 Resilient Accessories 09.65.13.33

j. Possible LEED contributions for Resilient Accessories include MR:2, MR:4, MR:5 Cove Cap, for 1/8" thick material, round top specify (SCC [specify color by number and name]-a) Cove Cap, for 1/8" thick material, square top specify (SCC [specify color by number and name]-b) Cove Cap, for 1/4" or 5/16" thick material, rounded top specify (CCC [specify color by number and name]-a) Cove Cap, for 9/32 thick material, "L" shaped top specify (CCC [specify color by number and name]-b) Cove Cap, for 1/4" materials, square top specify (CCC [specify color by number and name]-c) Cove Cap, for 3/16" thick material, round top specify (CCC [specify color by number and name]-d) Cove Cap for 1/4" or 5/16" thick material "L" shape top specify (RCC [specify color by number and name]) Cove Cap Self Stick, for.080" thick material, rounded top, specify (SCC [specify color by number and name]-d) B. Chair Rail JOHNSONITE MILLWORK RESILIENT CHAIR RAIL Wood look resilient wall base with the following characteristics: a. Manufactured from a homogeneous composition of polyvinyl chloride (PVC). c. Abrasion Resistance: ASTM D 3389 0.22 mg/cycle. d. Millwork Chair Rails are to be 8 foot lengths per piece. e. Johnsonite offers a RESTART reclamation program for returning jobsite scrap f. 100% Recyclable g. Phthalate-free h. SCS FloorScore Certified and meets California Specifications Section 01350 i. Johnsonite facilities are ISO 9001 and ISO 14001 Certified j. Contains at least 14% pre-consumer recycled materials k. Possible LEED contributions for Resilient Accessories include MR:2, MR:4, MR:5 For Fortis, thickness 3/16" (.1875") (4.76mm), width 3" (7.62cm) specify (CHR [specify color by number and name]) For Bastion, thickness 5/16"(.3125") (7.94mm), width 4" (10.16cm) specify (CHR [specify color by number and name]-b) For Rampart, thickness 3/8" (.375") (9.53mm), width 4" (10.16cm) specify (CHR [specify color by number and name]-c) March 2013 Page 4 of 9 Resilient Accessories 09.65.13.33

C. Flexible Corner Guard JOHNSONITE FLEXIBLE CORNER GUARD with the following characteristics: a. Manufactured from a homogeneous composition of polyvinyl chloride (PVC). c. ASTM E 84, Standard Test Method for Surface Burning Characteristics of Building Materials, Class B, Smoke less than 450. d. Abrasion Resistance: ASTM D 3389 0.22 mg/cycle. e. Flexible Corner Guards are to be either 4 foot lengths or 8 foot lengths per piece, except, VGB-C (1-1/4 " x 1-1/4" return) is available in 8 foot lengths only. f. Johnsonite offers a RESTART reclamation program for returning jobsite scrap g. 100% Recyclable h. Phthalate-free i. SCS FloorScore Certified and meets California Specifications Section 01350 j. Johnsonite facilities are ISO 9001 and ISO 14001 Certified k. Contains at least 14% pre-consumer recycled materials l. Possible LEED contributions for Resilient Accessories include MR:2, MR:4, MR:5 For Corner Wall Guard 3/4" x 3/4" return, Thickness 1/8" (3.18mm) specify (VBG [specify color by number and name]-b [specify length] 4' or 9' length) For Corner Wall Guard 1-1/2" x 1-1/2" return, Thickness 1/8" (3.18mm) specify (VBG [specify color by number and name]-a [specify length] 4' or 8' length) For Corner Wall Guard 2-3/8" x 2-3/8" return, Thickness 1/8 " (3.18mm) specify (VBG [specify color by number and name] [specify length] 4' or 8' length) For Corner Wall Guard 1-1/4 " x 1-1/4" return, Thickness 1/8 " (3.18mm) specify (VBG [specify color by number and name]-c [specify length] 8' length) D. Tub Mouldings JOHNSONITE TUB MOULDINGS with the following characteristics: a. Manufactured from a homogeneous composition of polyvinyl chloride (PVC) for Bathtub, Counter, and Shelves with a luster finish. c. ASTM E 84, Standard Test Method for Surface Burning Characteristics of Building Materials, Class B, Smoke less than 450. d. Abrasion Resistance: ASTM D 3389 0.22 mg/cycle. e. Tub Mouldings are to be 5 foot lengths per piece. f. Tub Mouldings are to be white and with self-stick tape for installation. g. Johnsonite offers a RESTART reclamation program for returning jobsite scrap h. 100% Recyclable i. Phthalate free j. Contains at least 14% pre-consumer recycled materials k. SCS FloorScore Certified and meets California Specifications Section 01350 l. Johnsonite facilities are ISO 9001 and ISO 14001 Certified m. Possible LEED contributions for Resilient Accessories include MR:2, MR:4, MR:5 March 2013 Page 5 of 9 Resilient Accessories 09.65.13.33

For Tub Moulding for Bathtub, Counter and Shelves, height 1-1/2" specify (TM-50) For Tub Moulding for Bathtub, Counter and Shelves, height 1" specify (TM-50-A). E. Cove Filler Strip JOHNSONITE COVE FILLER STRIPS with the following characteristics: a. Manufactured from a homogeneous composition of polyvinyl chloride (PVC) for coved sheet goods and tread/riser combinations. c. ASTM E 84, Standard Test Method for Surface Burning Characteristics of Building Materials, Class B, Smoke less than 450. d. Abrasion Resistance: ASTM D 3389 0.22 mg/cycle. e. Johnsonite offers a RESTART reclamation program for returning jobsite scrap f. 100% Recyclable g. Phthalate-free h. SCS FloorScore Certified and meets California Specifications Section 01350 i. Johnsonite facilities are ISO 9001 and ISO 14001 Certified j. Contains at least 14% pre-consumer recycled materials k. Possible LEED contributions for Resilient Accessories include MR:2, MR:4, MR:5 For Cove Filler Strip, 1-3/4 " radius filler strip, specify (CFS-00) 12' lengths For Cove Filler Strip, 1-1/4 " radius filler strip, specify (CFS-00-A) 12' lengths For Cove Filler Strip, 1/2" radius filler strip for, specify (CFS-00-M) 5' lengths F. Subfloor Levelers JOHNSONITE SUBFLOOR LEVELER SYSTEM with the following characteristics: a. Manufactured from a homogeneous composition of polyvinyl chloride (PVC). b. Complies with A.D.A. requirements for Change of Level and meets the requirements for slope to rise ratio for Ramps. c. ASTM E 648, Standard Test Method for Critical Radiant Flux of 0.45 watts/cm 2 or d. Subfloor Levelers are to be 4 foot lengths per piece. e. Johnsonite offers a RESTART reclamation program for returning jobsite scrap f. Contains 14% pre consumer recycled content g. 100% Recyclable h. Phthalate-free i. SCS FloorScore Certified and meets California Specifications Section 01350 j. Johnsonite facilities are ISO 9001 and ISO 14001 Certified k. Possible LEED contributions for Resilient Accessories include MR:2, MR:4, MR:5 For Floor Level System taper 0"- 1/4" specify (LS-40) For Floor Level System taper 1/4"-3/8" specify (LS-40-B) For Floor Level System taper 3/8"-1/2" specify (LS-40-C) For Floor Level System taper 0"-3/8" specify (LS-40-D) March 2013 Page 6 of 9 Resilient Accessories 09.65.13.33

For Floor Level System taper 0"-1/2" specify (LS-40-E) For Floor Level System taper 0"-1/8" specify (LS-40-F) For Floor Level System taper 0"- 3/4" specify (LS-40-G) For Floor Level System taper 0"-1/4" with Track-Strip Platform specify (LS-40-K) 2.2 INSTALLATION MATERIALS A. Trowelable Leveling and Patching Compounds: Latex-modified, Portland cement based or blended hydraulic-cement-based formulation. B. Adhesives: Water-resistant type recommended by Johnsonite to suit resilient products and substrate conditions. 1. Johnsonite 965 Flooring and Tread Adhesive (use with Subfloor Levelers) 2. Johnsonite 946 Premium Contact Bond Adhesive (use with cove caps, chair rails, corner guards, and cove filler strips) 3. Johnsonite 975 Two-Part Urethane Adhesive (use with Subfloor Leveler) 4. Johnsonite 996 Two-Part Epoxy (use with Subfloor Leveler) PART 3 - EXECUTION 3.1 EXAMINATION A. Examine substrates, with Installer present, for compliance with requirements for maximum moisture content and other conditions affecting performance of the work. B. Verify that finishes of substrates comply with tolerances and other requirements specified in other Sections and that substrates are free of cracks, ridges, depressions, scale, and foreign deposits that might interfere with adhesion of resilient products. C. Proceed with installation only after unsatisfactory conditions have been corrected. 3.2 PREPARATION A. Prepare substrates according to manufacturer's written instructions to ensure adhesion of resilient products. 1. Verify that substrates are dry and free of curing compounds, sealers, and hardeners. 2. Remove substrate coatings and other substances that are incompatible with adhesives and that contain soap, wax, oil, or silicone, using mechanical methods recommended by manufacturer. Do not use solvents. 3. Mechanically remove contamination on the substrate that may cause damage to the resilient flooring material. Permanent and non-permanent markers, pens, crayons, paint, etc., must not be used to write on the back of the flooring material or used to mark the substrate as they could bleed through and stain the flooring material. 4. Prepare Substrates according to ASTM F 710 including the following: March 2013 Page 7 of 9 Resilient Accessories 09.65.13.33

a. Moisture Testing: Perform tests recommended by manufacturer. Proceed with installation only after substrates pass testing. 1) Perform anhydrous calcium chloride test, ASTM F 1869. Results must not exceed 5 lbs. Moisture Vapor Emission Rate per 1,000 sq. ft. in 24 hours. or 2) Perform relative humidity test using in situ probes, ASTM F 2170. Must not exceed 80%. b. A ph test for alkalinity must be conducted. Results should range between 7 and 9. If the test results are not within the acceptable range of 7 to 9, the installation must not proceed until the problem has been corrected. c. Alkalinity and Adhesion Testing: Perform tests recommended by manufacturer. 5. Wood subfloors: a. The floor must be rigid, free of movement. b. Single wood and tongue and groove subfloors should be covered with ¼" (6.4 mm) or ½" (12.7 mm) APA approved underlayment plywood. 1) Use ¼" (6.4 mm) thick underlayment panels for boards with a face width of 3" (76 mm) or less. 2) Use ½" (12.7 mm) thick underlayment panels for boards with a face width wider than 3" (76 mm). c. Do not install over OSB (Oriented Strand Board), particle board, chipboard, lauan or composite type underlayments. B. Fill cracks, holes, depressions and irregularities in the substrate with good quality Portland cement based underlayment leveling and patching compound and remove bumps and ridges to produce a uniform and smooth substrate. C. Floor covering shall not be installed over expansion joints. D. Do not install resilient products until they are same temperature as the space where they are to be installed. 1. Move resilient products and installation materials into spaces where they will be installed at least 48 hours in advance of installation. E. Sweep and vacuum clean substrates to be covered by resilient products immediately before installation. 3.3 RESILIENT ACCESSORY INSTALLATION A. Comply with manufacturer's written instructions for installing resilient accessories. B. Install with Johnsonite adhesive specified for the site conditions and follow adhesive label for proper use. March 2013 Page 8 of 9 Resilient Accessories 09.65.13.33

3.4 CLEANING AND PROTECTION Section 09.65.13.33 A. Comply with manufacturer's written instructions for cleaning and protection of resilient products. B. Perform the following operations immediately after completing resilient product installation: 1. Remove adhesive and other blemishes from exposed surfaces. 2. Sweep and vacuum surfaces thoroughly. 3. Damp-mop surfaces to remove marks and soil. C. Protect resilient products from mars, marks, indentations, and other damage from construction operations and placement of equipment and fixtures during remainder of construction period. 1. No traffic for 24 hours after installation. 2. No heavy traffic, rolling loads, or furniture placement for 72 hours after installation. D. Wait 72 hours after installation before performing initial cleaning. E. A regular maintenance program must be started after the initial cleaning. END OF SECTION 09.65.13.33 March 2013 Page 9 of 9 Resilient Accessories 09.65.13.33