June Residential Refurbishment Basements

Similar documents
June Non - Residential Refurbishment Internal lining walls

June Residential Refurbishment Exposed soffit floors

June Residential Refurbishment Separating walls

June Residential New Build Render and cladding walls

August 2008: Issue 1. Non - Residential New Build Pitched Roofs - Ceiling Level

April Section 2.3. Flat Roofs

EcoHome-Insulation.com. Aluminium Foil Bubble Insulation. General Purpose Insulation. Dry Lining. Cavity Wall. Insulation System.

K5 External Wall Board

THERMAL LAMINATES. for roofs, walls, floors and soffits

K12 Framing Board. Insulation INSULATION FOR USE BEHIND WALL LINING AND FRAMED WALLS

GypLyner UNIVERSAL Metal framed wall lining system


VISQUEEN RADON MEMBRANE SYSTEM

Thermal Laminate Board.


Xtratherm Thin-R Thermal Liner (XT/TL Grade)

K12 Framing Board. Insulation

Jabfloor 70, 100, 150, 200, 250

TW50. Insulation STANDARD DETAILS FOR 50 MM INSULATION BOARD IN A 100 MM CAVITY. Low Energy Low Carbon Buildings. Wall lining. Inner leaf blockwork

K5 External Wall Board

CI/Sfb (2 ) Rn7 M2 Fourth Issue June Product Selector INSULATION FOR ROOFS, WALLS & FLOORS. Low Energy Low Carbon Buildings

Specification. Project Name: Project reference: Written: by: Cathal Quinn Tel:

10 EXTREME BASEMENT PANELS

Multi-layer Insulation Blanket for Walls

HP Partial Fill. Robust, long-lasting protection

URSA MINERAL WOOL URSA Cavity Batts

SLAB ON GRADE Insul-Joint or Expansion Joint Material as Required by A/E Specifications AquaCheck Liquid Coating 400 (Waterproofing Membrane) with Aqu

PRODUCT SHEET 1 KINGSPAN KOOLTHERM K3 FLOORBOARD

Gas barrier and damp proofing accessories

PowerDeck F. PIR insulation for Warm Flat Roofs. Product Guide

Platinum. I n s u l a t i o n INSULATION FOR FLOORS. Low Energy Low Carbon Buildings

GypLyner. GypLyner. Metal framed wall lining system. All our systems are covered by SpecSure when using genuine Gyproc and Isover products.

Your reference for Recticel PIR insulation.

Dow Building Solutions. Insulating floors with STYROFOAM Solutions: basic principles

Floors Walls Roofs. Jabfloor Premium board Jablite Premium board Jabfloor board Jablite board. APPLICATION: Basements PRODUCTS: Vencel Resil Limited

GypLyner UNIVERSAL Metal framed wall lining system

V1/0715/AI/TDO1. KORE Loft. Insulated Flooring System Design Guide

Multi-layer Insulation Blanket for Walls

Xtratherm Thin-R Partial Fill Cavity Wall Board (XT/CW Grade)

Thermablok Aerogel Insulation Blanket Thermablok Aerogel Blanket

Garage Conversions. Technical Issues

REFLECTIVE TECHNOLOGY CONSTRUCTION MEMBRANES

1 Firestone EPDM Roofing Systems

CERTIFICATE OF APPROVAL No CF 517 FSI LIMITED

SEPTEMBER construction type cavity barriers. SP Firestop Systems. The purpose-made solution for cavity fire stopping

RADBAR DAMP-PROOF COURSES RADBAR HIGH PERFORMANCE DAMP-PROOF COURSE

Floors Walls Roofs. Jabroll. APPLICATION: Flat and Curved Roofs PRODUCTS: Vencel Resil Limited

Basements. Insulation INSULATION FOR BASEMENTS. Low Energy Low Carbon Buildings. CI/SfB. (13.9) Rn7 M2 Fourth Issue April 2017

Multi-layer Insulation Blanket for use in Walls

K103 Floorboard. Insulation INSULATION FOR FLOORS. Low Energy Low Carbon Buildings. CI/SfB. (13.9) Rn7 M2 Second Issue August 2016

RIW SHEETSEAL GR BENEFITS APPLICATIONS APPLIED TO

energy saving for the future

Multi-layer Insulation Blanket for Walls

RAINSCREEN DUO SLAB. Non-combustible thermal insulation

Superior Performance PIR Insulation XO/FB. Insulaton for Steel & Timber Frame. Walls 12/4956

Garage Conversion - Between and Under Joist Applications

reflective technology

LIQUID RUBBER INDUSTRIES ENGINEERING SPECIFICATIONS FOR ENGINEERS AND ARCHITECTS. Diagram 1: Standard Membrane Continuation 150 mm Overlap

4 EXTREME FOUNDATION PANELS

VISQUEEN WATERPROOFING MEMBRANES VISQUEEN GAS RESISTANT SELF ADHESIVE MEMBRANE

K12 Framing Board INSULATION FOR TIMBER AND STEEL FRAMING SYSTEMS. P E R F O R M A N C E Manufactured to BS EN ISO 9002: 1994 Certificate No.

OS Thermal System Installation Guide

Thermal Laminate Board.

TR26 LPC/FM / TR27 LPC/FM

SIKALASTIC-152 EXTERIOR WATERPROOFING MEMBRANE. Product. Scope. Appraisal No. 811 [2013] Appraisal No. 811 (2013) Amended 28 August 2017

URSA MINERAL WOOL URSA 10 & URSA 20 DIVERSO Loft Roll

Floors Walls Roofs. Jablite Premium board Jablite board. APPLICATION: Internally Lined Pitched Roof PRODUCTS: Vencel Resil Limited

Engineered Timber Systems AN INTRODUCTION. Low Energy Low Carbon Buildings. CI/SfB (2-) Rj7 - Thirteenth Issue September 2017

K11 Roofboard. I n s u l a t i o n. Low Energy Low Carbon Buildings

Thermablok Aerogel Isolation Strips Thermablok Aerogel Isolation Strips

The better way to build TM. Installation Manual FOUNDATION SIPs & FROST WALLS SIPs

Construction details:

PITTSBURGH CORNING (UK) PERINSUL HL PERINSUL HL

BS 5250:2011+A1:2016 CONTROL OF CONDENSATION IN BUILDINGS. ROOF VENTILATION EXPLAINED

OLDROYD THE ULTIMATE WATERPROOF MEMBRANE SYSTEM. Cavity Drainage Membrane incorporating Aquadrain

Tiling Tiling Finishes C08

K12 Framing Board INSULATION FOR TIMBER AND STEEL FRAMING SYSTEMS P E R F O R M A N C E

GENERAL INSTALLATION GUIDELINES

Styrodur C, Environmentally friendly extruded polystyrene free of CFC, HCFC, and HFC filled with air.

Certificate of Assessment

External Steel Stud and Top Hat Walls. Details SYSTEMS 176 NON-FIRE RATED SYSTEMS 176 FIRE RATED SYSTEMS 178 BRICK VENEER SYSTEMS 183 INSTALLATION 185

Permicav XV TM NEXT GENERATION OF VAPOUR-PERMEABLE INSULATION FOR WALLS WITH CAVITIES

ALL-IN-ONE THERMAL FLOOR SYSTEM NON STRUCTURAL TOPPING (NST)

K8 Cavity Board. Insulation CAVITY WALL INSULATION

Closed cell expanded polystyrene (EPS) insulation with graphite.

URSA MINERAL WOOL URSA Acoustic Roll

Regulations Detail Sheet 1

BISON PRECAST FLOORING SPECIFICATION

AIR BARRIER DESIGN PRINCIPLES AN OVERVIEW.

EasylationWall. External Wall Insulation System. bringing european innovation

USGBORAL.COM SYSTEMS+ INTRODUCTION OUTRWALL BRICK VENEER WALLS EXTERNAL WALLS INNOVATIVE SYSTEMS SOLUTIONS

WARMFLOOR. Installation Guide.

Part E robustdetails. robustdetails. January 2017 Update Pack. Dear Colleague,

PassiveDesign.org. Passive Construction. Name:...

GypLyner (walls) Metal framed wall lining system. GypLyner.

0331 Brick and block construction

Insulation. Second Issue November Quick Guide. Building a better Kingdom together. Low Energy Low Carbon Buildings

The Celotex Handy Guide

Typical detail: New roof with breathable underlay

TECHNICAL PRODUCT GUIDE

Transcription:

June 2010 Residential Refurbishment 3.5.1 Basements

Residential refurbishment 3.0 Residential Refurbishment Basements Contents Introduction find online page Solution optimiser and pathfinder 293 Design considerations 294 Design Details 644 find online page Wall insulated externally Ba01 644 Wall insulated internally Ba02 646

Residential refurbishment: Basements 3.5 Basements Solution optimiser and pathfinder Basements Construction compatibility with Part L1B Max U-value for replacement and upgraded thermal elements- England and Wales, Scotland and Northern Ireland Max U-value for new thermal elements England and Wales, Scotland** and Northern Ireland Elemental U-value requirement Knauf Insulation solution U-values 0.30 0.29 0.28 0.27 0.26 0.25 0.24 0.23 0.22 0.21 0.20 0.19 0.18 Wall insulated externally Product*: Extra or Standard Description: Ultra strong XPS insulation installed externally to the basement wall and below floor screed Page No: 644 Ba01 Wall insulated internally Product*: Description: Ultra strong XPS insulation installed internally to the basement wall and below floor screed Page No: 646 Ba02 Key U-values achievable by constructions within this document. * Recommended Knauf Insulation product(s). Other products may be applicable. Pb01 Find online. Visit www.knaufinsulation.co.uk and key in construction code to find the most up to date information on your chosen solution. ** Also max U-value for replacement and upgraded thermal elements Calculating U-values for Basements Heated basement The methods used to calculate U-values for basement floors are very similar to those used for a concrete ground bearing floor, with the addition of an allowance for the average depth of the basement. The perimeter and area of the basement floor need to be taken into consideration as does the type of ground upon which the basement bears and the thickness and thermal performance of the basement wall. When a basement floor is insulated it is possible that this will cause the U-value of the basement walls to increase. As heat flow through the insulated floor will decrease making the ground colder which results in an increase in the heat flow through the basement walls. It is therefore better to calculate the U-values for the basement floor and walls together and then assess the total heat loss from the basement. Unheated basement An unheated basement will usually have insulation installed within or above the floor deck which separates the heated areas from the basement. The basement U-value will depend on the average depth of the basement, the perimeter and area of the basement floor, the height of the floor above ground level, and an allowance for the ventilation of the basement based on the number of air changes per hour. The overall calculation of the heat loss from the basement includes the U-value for the floor and walls, and the U-values for the walls are calculated in the same way as for a heated basement. 293

3.5 Residential refurbishment: Basements Basements Basement design Waterproofing BS 8102: 1990 Code of practice for protection of structures against water from the ground, gives three categories of waterproofing for a basement: Tanking A continuous waterproof barrier is applied to the inside or outside of the basement structure. Structurally integral protection Usually water resistant concrete in combination with a waterproof membrane. Drained cavity Cavities are formed within the walls and floor to collect and drain away the ingress of water. Heat loss The pattern of heat loss from a basement wall is complex, with the rate of heat loss diminishing as the depth of the basement increases. This is due to the insulation value of the ground behind the basement wall. A method for calculating U-values for basements is given in BS EN ISO 13370 and also in BCA/ NHBC Approved Document Basements for Dwellings. Position of insulation External rigid insulation is the preferred method for insulating new basement walls. Externally insulated External insulation is the preferred option for new build basements as the whole structure is kept warm, with negligible risk of condensation. The insulation should be placed up against the waterproofing membrane. Polyfoam extruded polystyrene is recommended because it has negligible moisture absorption and high compression resistance. A drainage membrane or layer of washed no fines gravel should be placed adjacent to the insulation. This relieves hydrostatic pressure and channels water to the foundation drain. The membrane or gravel should be covered with a geotextile to prevent fines from blocking the drainage material. Externally insulated basement walls Ground to slope away from wall and have impermeable finish wherever possible Basement and wall insulation to overlap Concrete block retaining wall with reinforced poured concrete infill Waterproofing membrane Cavity drainage membrane or use free-draining backfill Floor insulation below screed Geotextile membrane Perforated pipe as foundation drain, 200mm below basement floor, with coarse gravel surround 294

Residential refurbishment: Basements 3.5 design detail finder Knauf Insulation solutions for these types of construction can be found ±on pages 642-647. Internally insulated Internal insulation of basement walls is recommended for existing basements where it is not possible to insulate the basement externally. Any insulation system applied to the interior of the basement should have the following properties: It must allow the basement wall to dry out to the inside, for example by means of a cavity drainage system It must prevent warm moist air reaching the cold basement wall and condensing. A vapour control layer should always be installed on the warm side of the insulation, all joints and perforations should be well sealed Materials in contact with the basement wall and floor must be moisture tolerant The detail below shows a solution for an existing basement with solid brick walls. There is a drained cavity system directly behind the brickwork which drains to a sump. The insulation should ideally be closed cell, such as Polyfoam. A vapour control layer should be provided to the face of the insulation to prevent moisture vapour from the basement rooms condensing on the cold cavity drainage system. Other considerations The land around the building should slope away from the basement walls. Ideally the area adjacent to the building should have an impermeable finish, such as paving. For new basements, a drain should be located around the perimeter of the basement and positioned at least 200mm below the finished level of the basement floor. It should be bedded and surrounded in free draining aggregate and wrapped in a geotextile before backfilling, to prevent fines from blocking the drain. Internally insulated basement walls Continuity insulation with joints taped and sealant applied to junctions with surrounding structure Top of cavity drainage membrane sealed to prevent moisture escaping Plasterboard on timber or steel frame allows services to be installed Ground to slope away from wall and have impermeable finish wherever possible Existing basement wall Vapour control layer on the face of the insulation Cavity drainage membrane directs water from basement wall to sump in floor 295

6.4.1 Design details: Basements Basements Wall insulated externally Advantages 3 Long term exposure to water has negligible impact on the thermal performance of Polyfoam 3 Polyfoam is a very robust product, able to withstand the pressure exerted by backfill without compromising integrity or thermal performance Ba01 3 The insulation layer separates and protects the waterproofing layer from the backfill 3 Keeps the structure warm and creates a thermal store in the walls Geotextile membrane around drainage at base of wall Drainage channel membrane Basement wall Waterproof membrane Products is 100% ozone friendly, extruded polystyrene, rigid board insulation. It is lightweight, yet has excellent structural strength and long term effectiveness. It is available in two grades that are suitable for this application: Standard domestic and light commercial loading Extra commercial, industrial flooring and cold storage Standard and Extra are square edged boards. Typical construction Masonry or in-situ concrete basement walls with Standard placed against the tanking membrane. For basements between 2.5m and 5m deep, Extra is recommended for its greater compressive strength. The basement wall insulation is protected by a drainage cavity membrane which also reduces hydrostatic pressure and directs water to the foundation drain. Installation is placed against the tanking membrane and is protected by a drainage cavity membrane. Carefully backfill with free-draining granular material to hold the drainage cavity membrane and insulation in place. Polyfoam boards projecting above the ground should be covered by a reflective or light coloured flashing, board or similar to prevent long term exposure of the insulation to UV light. 644

Design details: Basements 6.4.1 Junction of basement and external wall Cavity wall insulation Cavity tray Minimum 150mm overlap between wall and basement insulation to minimise thermal bridging Typical specification Place Standard*/ Extra*,...mm thick, against the tanking membrane. Cover with a drainage cavity membrane, manufactured by... and carefully backfill to hold the insulation in place. (*delete as appropriate) Alternatively, refer to NBS clause: M10/40 or M10/290 Drainage channel membrane Reinforced concrete infill to engineer s design Waterproof membrane Performance Thermal insulation The thermal conductivities of Polyfoam Floorboard products are as follows:- Standard: 0.029 W/mK Extra: 0.029-0.034 W/mK Table 82 shows the U-values for a typical basement wall insulated with Polyfoam Floorboard. Compression resistance is highly resistant to compression and withstands both occasional and long term static loads. Moisture resistance has negligible water absorption and is unaffected by standing in ground water. Fire performance In the construction shown above, Polyfoam Floorboard is completely enclosed by other materials and will not contribute to the development stages of a fire or present a smoke or toxic hazard. Table 82: Typical U-values for basement walls insulated externally U-values (W/m 2 K) for basement depth (m) of: Thickness (mm) 2.0 2.5 3.0 3.5 Standard 85 0.20 0.19 n/a n/a 75 0.22 0.20 n/a n/a 65 0.24 0.22 n/a n/a 50 0.28 0.26 n/a n/a 35 0.34 0.31 n/a n/a Extra 75 n/a n/a 0.20 0.19 65 n/a n/a 0.22 0.20 50 n/a n/a 0.24 0.23 35 n/a n/a 0.29 0.27 25 n/a n/a 0.33 0.31 Notes: The U-values have been derived from BS EN ISO 13370 and BCA/NHBC Approved Document Basement for Dwellings. The calculations assume that the basement floor has a U-value of 0.25 W/m 2 K. 645

6.4.1 Design details: Basements Basements Wall insulated internally Advantages 3 The high compressive strength of Polyfoam makes it the ideal product for insulating under the floor screed 3 Polyfoam is robust and lightweight, making it easy to handle on site and highly resistant to mechanical damage Ba02 Vapour control layer Plasterboard Independent frame Existing basement wall 3 is a strong and moisture resistant insulation board, its compressive strength accommodates the loads associated with the fit out of the basement Screed Slip layer Cavity drainage membrane Products is 100% ozone friendly extruded polystyrene rigid board insulation it is lightweight yet has excellent structural strength and long term effectiveness It is available in two grades suitable for this application: Standard domestic and light commercial loading Extra commercial, industrial flooring and cold storage Typical Construction Existing solid brick basement wall with new cavity drainage membrane, Polyfoam Floorboard insulation and Knauf I stud independent lining. This system is most applicable for existing basement walls. The cavity drainage membrane collects any water that passes through the basement wall and drains it to a sump, from where it is pumped to a drain. Polyfoam Floorboard is fixed to the cavity drainage membrane using a non-solvent based adhesive. The internal lining allows services to be accommodated. Installation Insulate the basement walls by fixing Polyfoam Floorboard to the cavity drainage membrane using plaster adhesive dabs. Ensure the floor and wall insulation are closely butt jointed. It is best practice to include a vapour control layer on the warm side of the insulation. All joints to be adequately sealed. The wall vapour control layer should be sealed to the slip layer placed below the screed. After the floor slab or screed has been laid, construct the Knauf I stud lining and line the steel studwork with plasterboard. 646

Design details: Basements 6.4.1 Sump in basement floor Vapour control layer Discharge pipe to outside Inspection cover Typical specification Standard*/Extra*... mm thick, to be fixed directly against the drainage cavity membrane, by dabs of plaster adhesive. Cavity drainage membrane drains into sump Tape all joints with an aluminium faced self-adhesive tape. Seal the junction between the and the surrounding construction with a water resistant, solventfree silicone sealant. Alternatively, refer to NBS clause: M10/40 or M10/290 Sump pump Performance Thermal insulation The thermal conductivities of Polyfoam Floorboard products are as follows:- Standard: 0.029 W/mK Extra: 0.029-0.034 W/mK Table 83 shows the U-values for a typical basement wall insulated with Polyfoam Floorboard. Compression resistance is highly resistant to compression and withstands both occasional and long term static loads. Moisture resistance has negligible water absorption and is unaffected by standing in ground water. Fire performance is completely enclosed by other materials and will not contribute to the development stages of a fire. Table 83: Typical U-values for basement walls insulated internally U-values (W/m 2 K) for basement depth (m) of: Thickness (mm) 2.0 2.5 3.0 3.5 Standard 85 0.19 0.18 0.17 0.16 75 0.21 0.20 0.18 0.17 65 0.23 0.21 0.20 0.19 50 0.27 0.25 0.23 0.22 35 0.33 0.30 0.28 0.26 Notes: The U-values have been derived from BS EN ISO 13370 and BCA/NHBC Approved Document Basement for Dwellings. The calculations assume that the basement floor has a U-value of 0.25 W/m 2 K. Compressive creep results for Polyfoam Floorboards Product Polyfoam Standard Polyfoam Extra Load applied (kpa) Initial compression (%) Further compression after 50 years (%) 60 2 1.5 120 2 1.5 Polyfoam Super 175 2 1.5 647

Knauf Insulation Ltd PO Box 10 Stafford Road St Helens Merseyside WA10 3NS UK Tel: 01744 766 600 Fax: 01744 766 750 www.knaufinsulation.co.uk Ref: KB142610 June 2010 Knauf Insulation Ltd Customer Service (Sales) Technical Advisory Centre Literature PO Box 10 Tel: 0844 800 0135 Tel: 01744 766 666 Tel: 08700 668 660 Stafford Road Fax: 01744 612007 Fax: 01744 766 667 Fax: 0870 400 5797 St Helens Email: sales@knaufinsulation.com Email: tech@knaufinsulation.com Email: info@knaufinsulation.com Merseyside www.knaufinsulation.co.uk WA10 3NS