Data Loggers for Routine Control. CSSD Medical Hygiene Control

Similar documents
ebro Validation-Set for large Steam Sterilizers SL 2100 The Set contains:

Professional Measurement Technology FOOD PHARMACEUTICAL LABORATORY MEDICAL INDUSTRIAL

Professional Measurement Technology FOOD PHARMACEUTICAL LABORATORY MEDICAL INDUSTRIAL

Professional Data Logger

EBI 10 High Precision Wireless Data Loggers

Professional thermometer and food oil monitor

PRODUCT CATALOGUE. for gke Steri-Record and gke Clean-Record Chemical indicators, PCDs and accessories for cleaning and sterilization

They can be used on washer-disinfectors, ultrasonic cleaners, surgical instruments and endoscopes. Page 5

Modularity systems. made of high performance synthetic material, silicone and metal. Sterisafe Toolsafe

PRODUCT CATALOGUE. for gke Steri-Record and gke Clean-Record Chemical indicators, PCDs and accessories for cleaning and sterilization

Food safety can be measured. Check limit values, ensure quality, comply with HACCP with measuring instruments from Testo.

Melting Point M-565 Technical data sheet

Steam Sterilizer. SA Series. for hospitals, CSSD and medical centers

COMBIMASS. Technical Data COMBIMASS GA-m / GA-e Version

DOCUMENTATION Logging Evaluation Release Archiving. MELAflash MELAnet Box MELAtrace MELAdoc MELAprint MELAcontrol MELAcontrol PRO

Endoscope Washer Disinfector Cleaning Process Challenge Devices Research & Validation

Implementation and application of EN ISO

Hollow, porous, solid,? Testing of Steam Sterilizers

Dental X has been synonymous with Italian excellence in sterilisation since Almost forty years side by side with dental professionals, who find

Partnership. Hospital Sterilizers. T-Max Line

Blackbox for sensitive freight.

Fast. Easy to use. Secure traceability.

Sirona competency in hygiene DAC PROFESSIONAL. Hygiene systems. Vacuum autoclave class B to satisfy the most demanding requirements

ISO INTERNATIONAL STANDARD

MEDICAL TRADING knows the meaning of sterilization very well: it can be

ULTRAHEAT/ ULTRACOLD T230. Ultrasonic Heating and Cooling Meter Residential. Ultrasonic Static Meter

CERTIFICATE OF CONFORMANCE Mesa Laboratories, Inc. 625 Zoot Way, Bozeman, MT Phone: (303)

Getinge da Vinci Solution

Instrument technology moves into process development laboratories

Analyzing & Testing. Guarded Hot Plate - GHP. Method, Instrumentation, Applications. GHP 456 Titan. Leading Thermal Analysis

Hygiene Monitoring. Chemical Indicators, BD-Test and Batch- Product Information. CI_01_Eng

Partnership. Hospital Sterilizers. T-Max Line

PORTABLE HARDNESS TESTING

ULTRAHEAT / ULTRACOLD T550 (UH50...) The Professional: High-precision, modularity, reliable technology for all applications

A UT OCL A VE VE OCLA UT A _AutoClave_D1102EN_1703.indd /03/01 13:45

ENDOSCOPIC REPROCESSING ETD DOUBLE Advancing the Efficiency of Reprocessing.

Trust but verify: Ensure product quality at all stages of production


XMP i. Precision Pressure Transmitter for the Process Industry with HART -Communication. Stainless Steel Sensor

XMP i. Precision Pressure Transmitter for the Process Industry with HART -Communication. Stainless Steel Sensor

It s simple. USB data logger testo 184. Easy temperature monitoring and uninterrupted quality documentation in the transportation of pharmaceuticals.

The Fast and Robust Flue Gas Measuring Instrument for All Important Parameters

PRODUCT CONFORMITY CERTIFICATE

RevospECT PRO AUTOMATED ANALYSIS SOFTWARE POWER YOU CONTROL.

Process monitoring. ToolScope

X-MET8000. Trust but verify: Ensure product quality with Oxford Instruments latest handheld XRF analyser

T230. Ultrasonic Static Meter. Ultrasonic Heating and Cooling Meter Residential

AlgaeTorch. The handy measurement instrument for rapid deployment. Fast and simple algae monitoring

Automatic Foam Hardness Tester. PC computer controlled. High specification

Model BF 720 Incubators Avantgarde.Line with forced convection

Automatic Tabletop Autoclaves

LARGE CAPACITY PHARMACEUTICAL AUTOCLAVES

AS/NZS 4187 RELEVANT STANDARDS. Robyn Williams NUM CSSD LBHHS & Standards Australia Chair HE-023

EUROλYZER STx. Flue Gas Analyzer. BlueLine

Comprehensive process documentation and sterile supply management. NetBox.2 and EuroSDS systems

COATING THICKNESS MEASURING

Just a few clicks away from a heating system

Temperature & Humidity Monitoring Solutions for Cold Chain

x act i Precision Pressure Transmitter for Food Industry, Pharmacy and Biotechnology Stainless Steel Sensor accuracy according to IEC 60770: 0.


The new testo 330 LL visualizes measurement data graphically

ULTRAHEAT T350 (2WR6...) Ultrasonic Heat Meter. Residential. Residential

Highly efficient flue gas analyzer

Temperature mapping and autoclave validation specialists

SENTRON Powermanager. SENTRON Powermanager. Identifying hidden potential for energy optimization and savings. Answers for industry.

TRACECARE Monitoring, Reporting & Traceability Solutions

Sterilization. Euronda Spa t (+39) m euronda.com

Instruments for Food Technology QUALITY ASSURANCE TRANSPORT STORAGE

The Bowie & Dick test is used by manufacturers

ISO INTERNATIONAL STANDARD

Guideline will serve as an orientational guide to those centres entrusted with validation, certification

Vacuum pumps for table top steam autoclaves

PRODUCT CONFORMITY CERTIFICATE

Stericool H 2 O 2. plasma sterilizers Affordable low temperature solution

SoftMax Pro 5 Software

ISO INTERNATIONAL STANDARD

Plasma Low Temperature Sterilization. With vaporized hydrogen peroxide. PlazMax Line

Laboklav. Type 55 to 195 Liter. Technical Datasheet. Dampfsterilisatoren Steam sterilizers

Instruments for Food Technology. Quality Assurance TransporT Storage

Vortex Flowmeter FV4000 (TRIO-WIRL V) Swirl Flowmeter FS4000 (TRIO-WIRL S)

OPUS20 LAN-Datalogger Future Inside

Technology_ KUKA.Sim EN

HND-F. Hand-held Humidity Precision Measuring Unit % weight moisture % relative humidity. starting with ± 0.1%

x act i Precision Pressure Transmitter for Food Industry, Pharmacy and Biotechnology Stainless Steel Sensor accuracy according to IEC 60770: 0.

SIMPLIFY YOUR MAILING SYSTEMS WITH A POWERFUL MAIL SOFTWARE SOLUTION. Managing Your Mailing And Shipping Is Easier Than Ever!

ph & TDS instrumentation 2017 specialists in temperature measuring equipment for over 30 years

???? Spot Check Measurement Simple, accurate, reliable

PMA 31-G. English. Printed: Doc-Nr: PUB / / 000 / 00

Pressure transducers DMU 02 Vario (flush)

Agilent Technologies U7238A MIPI D-PHY Compliance Test Software for Infiniium Oscilloscopes

Partnership. HSG Pre & Post Vacuum - Medium Size Mobile Autoclave. Economic Line

PORTABLE ULTRASONIC HARDNESS TESTER

Improve Visibility and Control of Your Siemens Point-of-Care Testing

Do you need specific data for efficiently managing your trucks? We can supply you with ISM Online. The information system for truck management.

Model BF 260 Incubators Avantgarde.Line with forced convection

Loesche Automation Technology

MEASURING RAILWAY VEHICLES AND COMPONENTS

Energie meets Quality.

FUNCTION MODULES ANALYSIS CONTROL MODULE ARCHITECTURE MODULE DESCRIPTION PROCESS LEVEL

Transcription:

Data Loggers for Routine Control Washer-Disinfectors / Washer-Disinfectors for Endoscopes / Steam Sterilizers / Bedpan Washers CSSD Medical Hygiene Control

Routine control made easy with ebro data loggers EBI 100 data loggers With the EBI 100 data loggers, ebro offers reliable measurement devices for routine control of steam sterilizers, washer-disinfectors and washer-disinfectors for endoscopes according to German guidelines and ISO 15883. The data loggers are available in different versions including temperature or temperature / pressure loggers with and without external probes. They record the temperature and pressure variation over time during the washer-disinfector or sterilizer process and can easily be read out on a computer with the help of Winlog. med software. This software will make the test evaluation easy, and automatically calculates the A 0 value. Starter sets Starter set SL 1010 EBI 100 With the EBI 100 starter sets you can start your routine control process immediately according to the German guideline. In addition: Extend your sets with an EBI 15 data logger, and you will be able to perform daily electronic Bowie Dick Tests. Starter set SL 1110 For temperature monitoring and A 0 value calculation in bed pan washers. EBI 100-T100 temperature data logger ph tester Conductivity tester For temperature and pressure monitoring as well as for A 0 value calculation in washer-disinfectors, washerdisinfectors for endoscopes and steam sterilizers. EBI 100-TP231 pressure / temperature data logger with Luer-Lock connection ph tester Conductivity tester Silicone protection box for logger

Electronic Bowie Dick Test with the EBI 15 data logger With the EBI 15 data logger, ebro has developed an easy to use and very reliable measurement system for comprehensive routine control of steam sterilizers as well as for the execution of the Bowie Dick Test according to EN ISO 11140-4 and ISO 17665. In addition, the system can check relevant sterilization parameters such as vacuum, compensation time, hold time and sterilization temperature as well as steam penetration. After completing the test, data read-out and graphic test evaluation is done with ebro s Winlog.med software. EBI 15 Bowie Dick Test With the EBI 15 starter sets you can start your Bowie Dick Test immediately according to the norms EN 285 / ISO 17665. SL 1610 set For performing the daily Bowie Dick Test and for routine control of steam sterilizers, washerdisinfectors and washer-disinfectors for endoscopes. Bowie Dick Test EBI 15 EBI 100-T100 temperature data logger SL 1500 set For performing the daily Bowie Dick Test in steam sterilizers. Bowie Dick Test EBI 15

What does the EBI 15 accomplish? Bowie Dick Test: The EBI 15 delivers clear results during daily checks of the air evacuation test and steam penetration test according to ISO 17665, EN ISO 11140-4 and DIN EN 285. Early warning system: The EBI 15 provides early identification of possible failures in steam-sterilizers. Even the smallest quantities of residual air that doesn`t lead to a failed Bowie Dick Test yet are detected. Vacuum check: The EBI 15 allows a reasonable vacuum check also for sterilizers without pressure display according to DIN EN 285. Benefits Easy use, evaluation and documentation of the Bowie Dick Test Clear, automatic passed / fail evaluation Reusable after 500 cycles with service and calibration by ebro Conforms with ISO 17665, EN ISO 11140-4 and EN 285 Certified by TÜV Industrial Services and SMP Verification of sterilization parameters: The EBI 15 checks the sterilization temperature and the sterilization time at +134 C (+273 F) for 3 minutes according to DIN EN 285. Calculation of lethality (F 0 ): The EBI 15 monitors deviations between cycles by calculating total quantity of energy expended during sterilization process which is displayed by the F 0 value.

www.ebro.com 2011 2011 ebro ebro Electronic Electronic GmbH GmbH Peringerstraße 10 D-85055 Ingolstadt Ingolstadt Easy data read-out with Winlog.med software During the routine monitoring of washer-disinfectors, washer-disinfectors for endoscopes and steam sterilizers the pressure and temperature variation in time is documented with the help of the data loggers. During the evaluation, the software recognizes and checks all relevant phases of the sterilization. In addition, all of the required parameters are calculated and graphically displayed with the help of the software. Winlog.med software allows the simultaneous start or readout of multiple data loggers. After the routine monitoring process is concluded, Winlog.med delivers a clear and error-free pass/fail evaluation. The evaluation is fully automated by Winlog.med, which facilitates the daily work of the user. Benefits Only one software is required: Winlog.med software can be used for the evaluation of EBI 100 data loggers as well as for the EBI 15 Bowie Dick Test. Only one interface is required, which can be applied for EBI 100 data loggers and for the EBI 15 Bowie Dick Test. System requirements For the software to operate smoothly on your computer, your computer must meet the following requirements: Processor speed with at least 1 GHz At least 1 GB working storage At least 1 GB free hard disc storage USB 2.0 (Universal Serial BUS) Microsoft Windows XP or Windows 7

Technical Data EBI 100-T100 Temperature data logger EBI 100-TP231 Pressure / temperature data logger EBI 15 Bowie Dick Test Temperature measurement -40 C +150 C 0 C +150 C 0 C +150 C range Temperature accuracy ±0.3 C ±0.3 C ±0.1 C Pressure measurement range 1 mbar... 4000 mbar 1 mbar 4000 mbar Pressure accuracy ± 20 mbar ± 15 mbar Protection class IP 68 IP 68 IP 68 Battery 3.6 V, user replaceable 3.6 V, user replaceable 3.6 V, user replaceable Factory calibration certificate According to ISO 9001/2000 According to ISO 9001/2000 According to ISO 9001/2000 ebro Electronic GmbH Peringerstr. 10 85055 Ingolstadt, Germany Tel +49 841 95478-0 Fax +49 841 95478-80 Internet: www.ebro.com E-Mail: ebro@xyleminc.com All names are registered tradenames or trademarks of ebro Electronic GmbH. Technical changes reserved. 2013 ebro Electronic GmbH. February 2013