Carbon / Hydrogen / Sulfur Analyzers

Similar documents
Carbon / Sulfur Analyzers

Combustion Master CS Carbon and Sulphur Analyser

Compact flue gas analyser: testo 300 M-I

Just a few clicks away from a heating system

Fine particle measuring system

SKALAR. your partner in chemistry automation. Formacs series Total Organic Carbon & Total Nitrogen Analyzers

New Measurement Engineering For Monitoring Emissions In Industry

Highly efficient flue gas analyzer

Sum Parameter Analysis AOX/TOX. AOX Analyzer multi X 2500

Biogas analysers. Product overview. MRU over 30 years of innovative gas analysis! Biogas, landfill gas, biomethane, coal mine gas, CHP exhaust gas

Differential Scanning Calorimetry DSC 200 F3

testo 330 Flue gas analysis with increased convenience and safety

Trust but verify: Ensure product quality at all stages of production

Perkin Elmer HGA-600/ HGA-700 Graphite Furnaces

Dumatherm. C. Gerhardt - Analytical Systems. Dumas analytical System

TARGAS-1. Portable Photosynthesis System. Photosynthesis Soil Respiration Canopy Assimilation Environmental Monitoring

Excellence in gas analyzers since Over 186 years of Jobin Yvon optical experience. The expertise of HORIBA combustion technology

The next generation FT-NIR spectrometer. Innovation with Integrity FT-NIR

SKALAR. your partner in chemistry automation. Primacs SNC-100 Carbon and Nitrogen Analyzer

ONH836 Series: Oxygen/Nitrogen/Hydrogen by Fusion

SCION GC Series. The Gas Chromatographers Choice for Separations

TANGO. ANALYSIS TO GO. Innovation with Integrity. The next generation FT-NIR spectrometer. FT-NIR

Online Gas Analyzer / Monitor

Low-mass PM analyzer MEXA-1370PM Improvement of the Performance for PM Composition Analysis

// XPLORER-NS. Total Nitrogen and Sulfur Analyzer

The Fast and Robust Flue Gas Measuring Instrument for All Important Parameters

// XPLORER-NS. Full range Total Nitrogen, Total Sulfur instrument for the modern Laboratory.

EUROλYZER STx. Flue Gas Analyzer. BlueLine

testo 350 M testo 350 XL

DuMaster D-480 Technical data sheet

COLow COHigh COLow/H comp NO NOx NO2 CO2 H2S SO2 CXHY LANCOM 4. Portable Flue Gas Monitoring.

QuickTOC condensate. Online TOC for steam and condensate circuits. Analysing hot samples accurately. Precise. Fast. Reliable.

SMS 100 MERCURY ANALYZER SMS 100. Mercury analysis directly on solid samples from the undisputed leader in Atomic Spectroscopy

THERMAL DIFFUSIVITY THERMAL CONDUCTIVITY

Product data sheet DUMATHERM N Pro. for the automatic serial determination of NITROGEN

Thermoforming packaging machine R 145 with MULTIVAC Clean Design. Maximum process reliability and cleanroom suitability

July Table 1. General influencing trends of carbon and sulfur on the physical properties ofmetals.

Fpollutant-free zero air for analytical

For highest levels of purity

Introduction. From the combination of TG and DTA or HDSC one receives a broad range of information, such as:

Biogas analysers. Product overview. MRU over 30 years of innovative gas analysis! Biogas, landfill gas, biomethane, coal mine gas, CHP exhaust gas

Online data sheet MCS100E HW-C CEMS SOLUTIONS

X-MET8000. Trust but verify: Ensure product quality with Oxford Instruments latest handheld XRF analyser

Prima PRO process mass spectrometer

Isco EZ TOC. TOC and TC Analysis Made Easy. Continuous on-line TOC/TC measurement using low-temperature oxidation

SCION GC Series. The Gas Chromatographers Choice for Separations

EuroFID Total Hydrocarbon Analyzer

Elemental Analysis (EA)

S700 Modular Gas Analyzer. Measures more than 60 different gases

COATING THICKNESS MEASURING

icap 7000 Plus Series ICP-OES Streamlined performance and ultra-low ICP-OES detection limits for routine laboratories

NotaPack 10. Fully automatic banknote packaging

In Motion Checkweighers

NIRS DS2500 flour analyser

Diode laser analyser LS4000 Ammonia slip measurement for DeNOx process

Measurement & Analytics Measurement made easy. AlSCAN TM and AlSCAN TM Argon Hydrogen analysis in liquid aluminum

BioTector System-C. Online TOC Analyzer for Clean Water Applications

Laser measurement of KCl vapor in 4 MW CFB boiler during straw combustion and ferric sulfate injection

REPORT NUMBER REPORT DATE SEND TO ISSUE DATE Apr 18, Apr 18, 2017 RECEIVED DATE Apr 05, 2017

CEM500-L. Online Gas Analyser. Specialist Of UV Spectroscopy

LANCOM4 PORTABLE FLUE GAS MONITORING. NO NO2 NOx CO2 H2S SO2 CxHy. CO low CO high O 2 QUALITY CUSTOMER SOLUTIONS

Module 4 : Hydrogen gas. Lecture 29 : Hydrogen gas

HAG-HF. Fully Automatic Fusion Machine

Proudly serving laboratories worldwide since 1979 CALL for Refurbished & Certified Lab Equipment Parker N2-04

Method Development for Direct Analysis of Mercury by Thermal Decomposition. David L. Pfeil

REFERENCE MEASURING INSTRUMENT

PRODUCT INFORMATION MCS100E HW/PD/CD MULTICOMPONENT ANALYZER SYSTEMS EMISSION AND RAW GAS MONITORING WITH HOT MEASUREMENT.

Moisture Analyzers ISO 9000 CERTIFIED

Infrared Temperature Measurement Systems. Designed for the Aluminium Extrusion Industry

Loss On Ignition measurement for oxidizable iron ores with C / H analyzer

Stack Gas Analyzer ENDA-7000 ULTIMATE. Ultimate Reliability. Ultimate. Ultimate. Dependability. Accessibility

Torch Combustion TOC Analyzer

Melting Point M-565 Technical data sheet

PRODUCT CONFORMITY CERTIFICATE

TURBIDITY TB 300 IR TB 210 IR TB 250 WL. General Catalogue April 2015

testo 340 Speed, power & precision in industrial combustion analysis.

FGA 300 Panametrics Flue Gas Oxygen Analyzer. GE Sensing. Features. Applications

Thermo Scientific GENESYS 10S Bio spectrophotometer

1080 Total Organic Carbon Analyzer

Silica Analyzer. Automated Silica Measurement Dependable and Sensitive

MAX300-RTG PRODUCT NOTE. Real-Time Gas Analysis Process Automation and Control Product Quality Analysis. Industrial Process Mass Spectrometer

Technical article. Making reliable use of digester gas energy

HFM Heat Flow Meter Thermal Conductivity Analyzer

Automated Mercury/Non-mercury Intrusion Porosimeter AMP-60K-A-1

Guide. Moisture Determination in Test Laboratories. Moisture Determination in Test Laboratories

Heat Value Gas Chromatograph ISO standard version

Moisture Analyzers. Whenever Moisture Content Counts

PORTABLE FLUE GAS ANALYZER

INTRODUCES ITS SOLUTIONS FOR BIOGAS MEASUREMENT

8 stream capability with dual mode (H 2 S & total Sulphur)

THE USE OF MICROWAVE TECHNOLOGY FOR DRY ASHING PROCEDURES. by S. E. Carr and C. R. Moser. CEM Corporation, Matthews, North Carolina.

Cubis High-Capacity Micro Balances: Weigh Minimum Amounts of Sample Directly into Heavy Flasks

HeatLine. Industrial heat processing systems

NovaWAVE. A new category of Automated Microwave Digestion

Differential Scanning Calorimetry DSC 404 F1

COMBIMASS Thermal Gas Flow

Moisture Analyzers ISO 9000 CERTIFIED.

Weighing Terminals. One Terminal. Many Solutions. Improved Processes. Greater Productivity.

ADI 7010 TOC Analyzer. Continuous monitoring of total organic carbon

Flue gas analyser. We measure it. testo 327 The special class entry instrument. Simple menu structure

Transcription:

CS-580 CHS 580 CS-580A CHS-580A Carbon / Hydrogen / Sulfur Analyzers CS-580 CHS-580 CS-580A CHS-580A ( Helios ) ELTRA Individual infrared cell configurations CHS Analyzers

Specialists for Elemental Analysis For more than 30 years ELTRA has been one of the leading manufacturers of elemental analyzers. Starting with combustion analyzers for carbon and sulfur determination ELTRA has extended its product range over the years with analyzers for oxygen, nitrogen and hydrogen as well as thermogravimetric analyzers. ELTRA instruments are used in industries such as steel, mining, automotive and aviation, construction materials and in universities for Research & Development. ELTRA is synonymous for high quality, customer-oriented solutions and efficient products. Thousands of satisfied customers worldwide are proof of the reliability of ELTRA analyzers. 2

Carbon, Hydrogen, Sulfur Analysis The determination of carbon, hydrogen and sulfur in organic solids and liquids is a routine application in laboratories and production. ELTRA employs the method of combustion analysis in a resistance furnace for element determination. With a high-capacity ceramic tube temperatures of up to 1,550 C can be applied, allowing for reliable, precise and reproducible determination even of sulfates in organic samples (such as coal or soil). The combustion gas is detected in element-specific infrared cells. As a special feature ELTRA offers simultaneous hydrogen analysis in addition to classical carbon and sulfur analysis providing the user with even more flexibility for a variety of laboratory applications. Carbon / Hydrogen / Sulfur Analysis For organic samples CS-580 CHS-580 04 In the CS-580 CHS-580 analyzers the sample is weighed in boats and then burnt in a horizontal resistance furnace at temperatures of up to 1,550 C. The sample is introduced manually into the furnace. CS-580A CHS-580A ( Helios ) 06 In the CS-580A CHS-580A analyzers the sample is weighed in crucibles and burnt in a vertical resistance furnace at temperatures of up to 1,550 C. An automatic sample loader feeds the sample to the furnace. Options 08 Technical Details 10 Software 12 Standard-Compliant Work 13 Applications 14 Technical Data 16 ELTRA also provides analyzers for: CS inorganic/organic samples ONH inorganic samples Thermogravimetry The CS-2000 is the only analyzer in the market which allows for C and S analysis in both inorganic and organic samples. This is made possible by ELTRA s Dual Furnace Technology (EDF) which combines induction and resistance furnace in one analyzer. The ONH-2000 is ideally suited for the quick simultaneous determination of oxygen, nitrogen and hydrogen in steel, cast iron, molybdenum, nickel, copper, zirconium, titan, ceramics and other inorganic samples. The Thermostep analyzer allows for determination of different sample parameters such as moisture, volatiles, and ash in one single analysis cycle. ELTRA Elemental Analyzers www.eltra.com 03

Carbon / Hydrogen / Sulfur Analyzers CS-580 CHS-580 For organic samples! Carbon Hydrogen Sulfur Resistance furnace Fast and precise element analysis in organic sample materials Benefits n Fast simultaneous determination of CHS n Powerful horizontal resistance furnace up to 1,550 C, adjustable in steps of 1 C n High sample weights of 500 mg and more possible n Customizable measuring range n Individual infrared cell configurations available ELTRA s CHS-580 is the ideal analyzer for the simultaneous determination of carbon, hydrogen and sulfur in organic samples. Thanks to sample weights of 500 mg and more, even inhomogeneous materials can be reliably analyzed. The temperature of the powerful horizontal resistance furnace with ceramic tube can be set in steps from 1 C to a maximum of 1,550 C. The analyzer can be equipped with up to four independent infrared cells according to the user s requirements, allowing for a great variety of applications. Typical sample materials Coal, coke, oil, soil, waste etc. The ELTRA 580 series features the following models: Analyzers for C, S, CS, CH, HS, CHS ELTRA Simultaneous CHS Determination CHS analyzers ELTRA CHS-580 analyzer 04

Simple and safe operation After weighing the sample in a ceramic boat, the weight is transferred from the interfaced balance to the PC. If required, sample weights can also be entered manually. Then the ceramic boat is introduced into the furnace for combustion. The average analysis time is 60 to 180 seconds. The detector signals and instrument parameters are displayed during analysis. Evaluation of the signals and display of the results are done automatically; the data can be transferred to a laboratory information management system (LIMS). The CHS-580 requires minimum maintenance. The particle filters and chemicals which need to be maintained are easily accessible. Weighing in the sample Manual introduction of the sample into the furnace Display of analysis results Robust measuring system easily adaptable to customer requirements In the CHS-580 the sample is burnt in an oxygen atmosphere at temperatures up to 1,550 C. The furnace temperature can be freely selected in steps of 1 C. The combustion gasses (CO 2, O, SO 2 ) coming from the furnace first pass through a dust filter and then into the heated O infrared cell. After the water vapor is chemically absorbed, the dried CO 2 and SO 2 gas is detected in the additional infrared cells. Depending on the configuration, it is possible to combine up to four (for CS analyzers) or up to three (for CHS analyzers) infrared cells with different sensitivities. O 2 SO 2 CO 2 O CO 2 trap O trap Particle filter O-Detektor O trap CO 2 detector SO 2 detector Horizontal resistance furnace ELTRA Elemental Analyzers www.eltra.com 05

Carbon / Hydrogen / Sulfur Analyzers CS-580A CHS-580A ( Helios ) For organic samples! Carbon Hydrogen Sulfur Resistance furnace Fully automatic, user-friendly sample analysis with CS-580A CHS-580A Benefits n Fully automatic, precise CHS determination with optional sample loader for 36 or 130 crucibles n Powerful vertical resistance furnace up to 1,550 C, adjustable in steps of 1 C n High sample weights of 500 mg and more possible n Customer-specific measuring range ELTRA s 580A analyzers (A = Autoloader) are equipped with an automatic sample loader, allowing for analysis of large numbers of samples without operator intervention. The sample loader is available in two versions to accommodate 36 or 130 crucibles. The 580A series is based on the technology of the CS-580 CHS-580 analyzers and features a vertical resistance furnace with ceramic tube. The temperature can be set in steps of 1 C to a maximum of 1,550 C. Thanks to sample weights of up to 500 mg and more even inhomogeneous materials can be reliably analyzed. The analyzer can be equipped with up to four independent infrared cells according to the user s requirements, allowing for a great variety of applications. Typical sample materials Coal, coke, oil, soil, waste etc. Reliable, reproducible analyses In the CS-580A CHS-580A the samples are weighed into crucibles. Then a gripper places the samples from the Autoloader on the pedestal. The samples are loaded consecutively into the furnace for combustion. The average analysis time is 60 to 180 seconds. Detector signals and instrument parameters are displayed during analysis. Evaluation of the signals and display of the results are done automatically; the data can be transferred to a laboratory information management system (LIMS). The analyzers require minimum maintenance. The particle filters and chemicals which need to be maintained are easily accessible. Weighing in the sample Sample feeding with the Autoloader Clearly structured measuring protocols 06

ELTRA Fully automatic sample analysis 580A series ELTRA CHS-580A analyzer with sample loader ELTRA s 580A series includes the following models: Analyzers for C, S, CS, CH, HS, CHS Precise and robust measuring system In the CS-580A CHS-580A analyzers the sample is burnt in an oxygen atmosphere at temperatures of up to 1,550 C. The furnace temperature can be freely selected in steps of 1 C. The combustion gasses (CO 2, O, SO 2 ) coming from the furnace first pass through a dust filter and then into the heated O infrared cell. After the water vapor is chemically absorbed, the dried CO 2 and SO 2 gas is detected in the additional infrared cells. Depending on the configuration, it is possible to combine up to four (for CS analyzers) or up to three (for CHS analyzers) infrared cells with different sensitivities. O 2 SO 2 CO 2 O CO 2 trap O trap Particle filter O detector O trap CO 2 detector SO 2 detector Vertical resistance furnace ELTRA Elemental Analyzers www.eltra.com 07

Options CS-580 CHS-580 CS-580A CHS-580A High-performance accessories for ELTRA analyzers A comprehensive range of instrument add-ons allows for adapting ELTRA analyzers to a variety of laboratory applications. The CS-580A CHS-580A can be equipped with two different sample loaders for high sample throughput. For the measurement of carbon and sulfur concentrations in the sensitive ppm range ELTRA offers a preheating furnace for boats and crucibles. Another option is the furnace extension for the CHS-580 which is used to reduce CO 2 contamination through ambient atmosphere. A TIC module is available for the determination of total inorganic carbon. Autoloader for CS-580A CHS-580A Benefits n Perfectly reliable in continuous operation n Simple assembly of crucibles n Robust technology ELTRA s CS-580A CHS-580A analyzers are designed for operation with an automatic sample loader. It is available with 36 or 130 crucible positions and allows for hours of unsupervised automatic operation. The Autoloader is ergonomically designed and very compact. The combination of a vertical resistance furnace with crucibles provides a robust and fail-safe sample feeding system for automated analyses. The sample loading system to the vertical furnace is particularly reliable and safe. Damages to the furnace, for example by incorrectly adjusted grippers, are virtually impossible. Sample loader for 36 samples Sample loader for 130 samples 08

Solutions for low element concentrations Graphic: Preheating furnace Preheating furnace HTF-540 For reliable determination of element concentrations in the sensitive ppm range it is necessary to reduce the blank values of crucibles and boats. For this purpose, the external preheating furnace HTF-540 is available in which the blank values of the sample containers are reduced at a temperature of approximately 1,350 C. Furnace extension for CHS-580 The CHS-580 can be equipped with a furnace extension which reduces the intrusion of atmospheric carbon dioxide due to a reduced tube diameter. As a consequence the blank values are significantly lower. Preheating furnace HTF-540 TIC module for carbonate analysis The modular design of ELTRA s analyzers allows for installation of an additional module for the determination of total inorganic carbon. The TIC module can be placed next to the analyzer; modifications of the gas flow system are not required. For TIC analysis the sample is treated with acid in an Erlenmeyer flask inside the TIC module. The infrared cells detect the carbon dioxide released during analysis. The results are displayed by the connected PC. Modular system 1 TIC module 2 CHS-580A 3 Sample loader 4 Balance 5 PC/Software The TIC module is available for the following models: CS-580 CHS-580 and CS-580A CHS-580A ELTRA Elemental Analyzers www.eltra.com 09

Technical Details CS-580 CHS-580 CS-580A CHS-580A ELTRA Robust analysis technology for organic samples CHS analyzers To ensure the complete combustion of organic samples, ELTRA analyzers are equipped with a resistance furnace with ceramic tube. The temperature Resistance furnace can be set in steps of 1 C to a maximum of 1,550 C which ensures reliable and reproducible determination also of sulfates. ELTRA analyzers are available as C, S, CS, CH, HS or CHS analyzers with individual measuring ranges according to the customer s requirements. Up to four independent infrared cells The infrared cells used in Benefits ELTRA analyzers combine precision with a long service n Long-term stability n Low maintenance n Long service life life. The use of a constant radiant IR source combined with a chopper blade is historically proven to be extremely reliable, offering a significantly longer operating time when compared to the chopper-less flashing IR source. The stability of the baseline, as well as the thermo control of the IR cells is monitored by the software. The analyzers can be supplied with up to four independent IR cells. The length of each cell can be manufactured to give the optimum measuring ranges. Graphic: Infrared cells with flexible measuring range Solid state detector with interference filter Chopper blade Cuvette Easily accessible particle filters and chemicals Gas inlet Window Infrared source Preamplifier Gas outlet All particle filters and chemicals which need to be changed on a regular basis are clearly assembled, easily accessible from outside and quickly exchangeable. The open assembly also allows for convenient visual control. 10

Horizontal resistance furnace The horizontal resistance furnace of the CS-580 CHS-580 is equipped with a ceramic combustion tube and silicon carbide heating elements. Full electronic control of the furnace ensures maximum service life of the components, including current limitation during heating-up. A sensor monitors ambient temperature and provides data for automatic reference point compensation of the thermo control, ensuring that the furnace temperature remains unaffected by fluctuations of the ambient temperature. The design of the resistance furnace boat stop forces the oxygen carrier gas to penetrate into the boat, ensuring efficient combustion of the sample. This design eliminates the need to employ fragile lances or honeycomb boat stops which tend to block with dust. Vertical resistance furnace in the 580A analyzers The CS-580A CHS-580A analyzers also employ a ceramic combustion tube and silicon carbide heating elements for temperatures up to 1,550 C. Graphic: Vertical resistance furnace Oxygen supply Gas outlet The robust design with automated sample loading and vertical furnace tube ensures particularly effective operation. Due to the vertical design of the resistance furnace sufficient oxygen is blown into the crucible, leading to efficient combustion of the sample. Oxygen enters the furnace via three inlets, one of which is a lance located directly above the crucible. This assembly guarantees a long service life of the ceramic tube. Benefits n Efficient O 2 supply to sample n Safe, convenient sample loading n Long service life of ceramic tube Oxygen supply ELTRA Elemental Analyzers www.eltra.com 11

Software CS-580 CHS-580 CS-580A CHS-580A PC control with Windows -based software ELTRA s instrument software ensures convenient control and operation of the analyzers. It is multilingual, easy to understand and provides the following features: n Custom layouts: user-defined display of windows and storage of different layouts n User profiles with multi-level access: creation of different hierarchy levels with different authorizations n Sample ID memory and serial numbering of samples n Storage of analysis results in data base: the data of each analysis is stored and can be called up later for reviews, reports, statistical calculations or recalculation of results with modified parameters n Programmable data base filter: user-defined selection of existing analysis data by sample name, date, ID or other parameters n Peak separation calculation for fractional analysis n LIMS communication and data export n One point or multi point calibration n Barometric pressure compensation n Simultaneous calibration of more than one measuring range n Automatic linearity correction n Applications memory and display of maintenance intervals: individual configuration of maintenance intervals n Hardware diagnostics display and print-outs of technical reports n Visualization of statistical data and results consistency ELTRA s Uni software provides clearly structured analysis protocols 12

Standard-Compliant Work CS-580 CHS-580 CS-580A CHS-580A ELTRA s CHS analyzers fulfill the requirements of all relevant standards ASTM standard compliance with regards to sulfur determination Standard Material to be analyzed Standard title D-1552 Oil and petroleum Standard Test Method for Sulfur in Petroleum Products (High-Temperature Method) D-4239 Coal and coke D-5016 Coal and coke combustion residues Standard Test Method for Sulfur in the Analysis Sample of Coal and Coke Using High-Temperature Tube Furnace Combustion Standard Test Method for Total Sulfur in Coal and Coke Combustion Residues Using a High-Temperature Tube Furnace Combustion Method with Infrared Absorption D-1619 Carbon black Standard Test Methods for Carbon Black Sulfur Content ISO and DIN standard compliance with regards to carbon determination Standard Material to be analyzed Standard title 10694 Soil Soil quality determination of organic and total carbon after dry combustion (elementary analysis) DIN EN 13137 Soil Characterization of waste Determination of total organic carbon (TOC) in waste, sludge and sediments ISO 15178 Soil Determination of total sulfur by dry combustion ELTRA Elemental Analyzers www.eltra.com 13

Organic Applications CS-580 CHS-580 With the resistance furnace of the CS-580 CHS-580 series the carbon, hydrogen and sulfur concentrations in organic samples can be determined quickly and precisely. The maximum temperature of 1,550 C allows for reliable analysis also of sulfates. Typical sample materials Coal/coke, oil, wood, biomass/refuse-derived fuels, rubber, lime/gypsum, soil, waste Example: Carbon, hydrogen and sulfur in lignite-coke For optimum control of flue gas desulfurization the exact determination of the sulfur concentration is essential. The CS-580 CHS-580 are able to analyze high sample weights (e. g. 200 mg) to compensate for the inhomogeneity of the sample. Thus, even low concentrations (such as in biomass) can be determined precisely and correctly. This method complies with the standards ASTM D1552 and ASTM D4239. Typical results for lignite-coke (CHS-580) Coke 222.5 mg 87.54 % C 0.60 % H 0.37 % S Coke 209.9 mg 87.20 % C 0.61 % H 0.37 % S Coke 205.6 mg 87.19 % C 0.59 % H 0.37 % S Coke 203.1 mg 87.53 % C 0.59 % H 0.36 % S Coke 206.5 mg 87. 43 % C 0.58 % H 0.36 % S Mean value: 87.38 % C 0.594 % H 0.366 % S Standard deviation: ± 0.17 ± 0.01 ± 0.005 Example: Carbon, hydrogen and sulfur in rubber Small volumes of rubber samples can also be analyzed easily and reproducibly with the CHS-580 for their carbon, hydrogen and sulfur concentrations. For sample preparation, the samples are homogenized to a fineness of 300 microns. Typical results for rubber (CHS-580) Rubber 40.0 mg 84.16 % C 5.88 %.15 % S Rubber 44.3 mg 84.02 % C 5.76 %.12 % S Rubber 43.5 mg 83.40 % C 5.77 %.14 % S Mean value: 83.86 % C 5.80 %.13 % S Standard deviation: ± 0.40 ± 0.07 ± 0.015 14

Organic Applications CS-580A CHS-580A Example: Carbon and sulfur in biomass Biomass is usually characterized by low sulfur concentrations. Biomass samples of approx. 200 mg can be analyzed quickly and reproducibly with the CS-580A CHS-580A analyzers. Excellent reproducibility! Typical results biomass (CS-580A) Biomass 214.0 mg 46.85 % C 0.018 % S Biomass 210.3 mg 46.99 % C 0.017 % S Biomass 214.5 mg 46.95 % C 0.017 % S Mean value: 46.93 % C 0.0173 % S Standard deviation: ± 0.07 ± 0.0006 Example: Carbon and sulfur in coal In the vertical furnace of the CS-580A CHS-580A analyzers, carbon and sulfur concentrations are analyzed quickly and reproducibly. Typical results coal (CS-580A) Coal 210.3 mg 55.99 % C 0.48 % S Coal 203.5 mg 55.99 % C 0.49 % S Coal 214.3 mg 55.83 % C 0.49 % S Coal 190.2 mg 55.78 % C 0.48 % S Coal 186.1 mg 55.67 % C 0.49 % S Mean value: 55.85 % C 0.486 % S Standard deviation: ± 0.14 ± 0.005 ELTRA Elemental Analyzers www.eltra.com 15

Technical Data Carbon / Hydrogen / Sulfur analyzers CS-580 CHS-580 CS-580A CHS-580A ( Helios ) C, S measurement up to 100%! * Measuring ranges 1) 500 mg sample 500 mg sample Low carbon measuring range 0.005 % 5 % C (25 mg C abs.) 0.005 % 5 % C (25 mg C abs.) High carbon measuring range 5 % 100 % C ( 500 mg C abs.) 5 % 100 % C ( 500 mg C abs.) Low sulfur measuring range 0.005 % 2 % S (10 mg S abs.) 0.005 % 2 % S (10 mg S abs.) High sulfur measuring range 2 % 20 % S (100 mg S abs.) 2 % 20 % S (100 mg S abs.) Hydrogen measuring range 2) 0.01 % 15 % H (75 mg H abs.) 0.01 % 15 % H (75 mg H abs.) Sensitivity 500 mg sample 500 mg sample Carbon measuring range 10 ppm C (5 µg C) 10 ppm C (5 µg C) Sulfur measuring range 2 ppm S (1 µg S) 2 ppm S (1 µg S) Hydrogen measuring range 2) 100 ppm H (50 µg H) 100 ppm H (50 µg H) Accuracy 1) 1 g sample 1 g sample Low carbon measuring range High carbon measuring range Low sulfur measuring range High sulfur measuring range Hydrogen measuring range 2) *) Depending on sample weight ±20 ppm C; resp. ±10 µg C or ±1 % of carbon content ±100 ppm C; resp. ±50 µg C or ±1 % of carbon content ±4 ppm S; resp. ±2 µg S or ±1 % of sulfur content ±100 ppm S; resp. ±50 µg S or ±1 % of sulfur content ±200 ppm H; resp. ±100 µg H or ±1 % of hydrogen content ±20 ppm C; resp. ±10 µg C or ±1 % of carbon content ±100 ppm C; resp. ±50 µg C or ±1 % of carbon content ±4 ppm S; resp. ±2 µg S or ±1 % of sulfur content ±100 ppm S; resp. ±50 µg S or ±1 % of sulfur content ±200 ppm H; resp. ±100 µg H or ±1 % of hydrogen content 1) CS-580: up to 4 infrared cells individually selectable / CHS-580: up to 3 infrared cells 2) Applies only to analyzers with hydrogen cell General data Material of IR path Gold 3) Gold 3) Standard sample weight 500 mg 500 mg Analysis time 60 180 seconds 60 180 seconds Furnace Resistance furnace (horizontal) with ceramic tube; adjustable up to 1,550 C in steps of 1 C Resistance furnace (vertical) with ceramic tube; adjustable up to 1,550 C in steps of 1 C Power supply 230 V AC ±10 %; 50/60 Hz; 2,000 W maximum heating capacity 230 V AC ±10 %; 50/60 Hz; 2,000 W maximum heating capacity Compressed air 4 6 bar Weight 70 kg Analyzer: 90 kg Sample loader: 10 resp. 15 kg Dimensions (W x H x D) 55 x 80 x 60 cm Analyzer: 55 x 100 x 60 cm Sample loader: 20 resp. 85 x 35 x 45 cm Chemicals CO 2 trap sodium hydroxide, O trap magnesium perchlorate Measuring principle Carrier gas Interfaces Accessories 3) for path length 10 mm, otherwise Aluminum Infrared absorption for carbon and sulfur Oxygen 99.5 %, 2 4 bar serial and USB Balance ±0.1 mg resolution / computer, monitor, printer (specifications on request) Eltra GmbH Retsch-Allee 1-5 42781 Haan, Germany Phone +49 21 04/ 23 33-400 Fax +49 21 04/ 23 33-499 E-Mail info@eltra.com Internet www.eltra.com Subject to technical modifications and errors 99000-0003/E-04-2017