SECTION PRE-ENGINEERED WOOD POST FRAME BUILDING SYSTEM. B. Products Supplied But Not Installed Under This Section:

Similar documents
Specifications for FL-100 Soffit Panel

POST FRAME BUILDING STANDARDS

SECTION PRE-ENGINEERED BUILDING INSULATION

SECTION METAL BUILDING SYSTEMS

CS-100 Guide Specifications

PRE-ENGINEERED METAL BUILDING SYSTEM

A. The extent of extruded aluminum walkway covers is shown on the Drawings and as specified herein.

METAL BUILDING SYSTEM SPECIFICATIONS

FIXED SERIES 6200 AAMA/WDMA/CSA 101/I.S.2/A Structural Performance: Thermal Break: Main Frame Depth: 3 1/4. Glazing Thickness (Maximum): 1

SECTION STEEL DECKING

SECTION PLATE CONNECTED WOOD TRUSSES

SECTION RADIATION SHIELDING ENCLOSURE Low Intensity Radiation Protection

SECTION ACCORDION FOLDING PARTITIONS

Central Dartmouth Section Exterior Envelope Renovations METAL-CLAD WOOD DOORS Page 1 of 5 Dartmouth, NS

Signature Series 5 Lap SECTION ALUMINUM WINDOWS

SECTION MANUFACTURED ROOF EXPANSION JOINTS

SECTION SLOPED TRANSLUCENT METAL SKYLIGHT SYSTEM

Built to Last a Lifetime

SECTION A. ACSE 7 Minimum Loads for Buildings and other Structures.

SECTION METAL ROOF PANELS

A. Pre-engineered, pre-finished extruded aluminum Pavilions.

SECTION COMPOSITE METAL WALL PANEL SYSTEM (Accu-Trac Low Profile DS)

SECTION [ ] COILING COUNTER DOORS. Display hidden notes to specifier. (Don't know how? Click Here)

Architectural Single-Hung Aluminum Window Series L701T SH-AW130 GUIDE SPECIFICATION

Guide Specification SDP 200

DIVISION 10 SPECIALTIES SECTION OPERABLE PARTITIONS

SECTION SECTIONAL OVERHEAD DOORS 522 SERIES ALUMINUM SECTIONAL OVERHEAD DOORS. Display hidden notes to specifier. (Don't know how?

SECTION INSULATED METAL WALL PANELS. ATAS International, Inc. General Specification for Commercial/Industrial and Architectural Applications

The Olympia Difference

PRE-ENGINEERED METAL BUILDINGS

SECTION OVERHEAD COILING FIRE DOORS MODEL 662 OVERHEAD COILING COUNTER FIRE DOORS WITH INTEGRAL FRAME

Student Services & Classroom Addition

SECTION ALUMINUM STORM WINDOWS

BAND SHELLS Our versatile Band Shells perform in any community

SECTION DECORATIVE METAL FENCES AND GATES

INSULATION RETROFIT DESIGN ENERGY SOLUTIONS CENTRE YUKON GOVERNMENT

SECTION MODIFIED BITUMINOUS MEMBRANE ROOFING Peel & Roof

SECTION EXTERIOR GRILLS AND SCREENS

General Overview SECTION PBR & R PANEL - PREFORMED ROOF AND WALL PANELS

SECTION Structured Polycarbonate Panel Assemblies. Series 3500 BPC System with 40mm Tongue and Groove

Corium Brick Rainscreen System Specifications

EXCEL Medical Waste - Equipment Installation Section SECTION GYPSUM BOARD

The Contractor is responsible for quality control, including workmanship and materials furnished by his subcontractors and suppliers.

SPECIFICATIONS - DETAILED PROVISIONS Section Prefabricated Steel Building C O N T E N T S

CASEMENT PROJECT OUT SERIES 6400 AAMA/WDMA/CSA 101/I.S.2/A Structural Performance: Thermal Break: Main Frame Depth: 3 1/4

Series - 1

SECTION RESIDENTIAL OVERHEAD DOORS SIGNATURE COLLECTION WOOD GARAGE DOORS

HORIZONTAL SLIDER SERIES 910 ANSI/AAMA/NWWDA 101/I.S Structural Performance: Thermal Break: C.R.F.: 50. Thermal U Value:.66. Main Frame Depth: 4

HORIZONTAL SLIDER SERIES 900 ANSI/AAMA/NWWDA 101/I.S Structural Performance: Thermal Break: C.R.F.: 50. Thermal U Value:.66. Main Frame Depth: 4

Series - 1

Alply CLASSIC WALL Architectural Insulated Panel Wall System

DOUBLE HUNG SERIES 860 AAMA/WDMA/CSA 101/I.S.2/A Structural Performance: Thermal Break: C.R.F. 50. Thermal U Value:.61. Main Frame Depth: 4

Section PANEL SIGNAGE

Wall Louvers (10200)

COLLEGE CLASSROOM & DORMITORY SPECIFICATION SECTION 08100

RAY-CORE Structural Insulated Roof and Wall Panels

FL200 13/4 x41/2 GUIDE SPECIFICATION. Non-Thermal Storefront

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: ROOFING AND SIDING PANELS REPORT HOLDER: KINGSPAN INSULATED PANELS, INC.

Specifiers: Click on the icon in the WORD toolbar to reveal detailed instructions

DUGOUT MODEL (4 POST) 10 x 24 SPECIFICATIONS

SINGLE HUNG SERIES 810 AAMA/WDMA/CSA 101/I.S.2/A Structural Performance: Thermal Break: C.R.F.: 50. Thermal U Value:.61. Main Frame Depth: 4

Code Compliance Research Report CCRR-0228

SECTION COPPER WALL PANELS. ***This section has been updated to IBC. Verify for specific project conditions.***

The following preliminary issues may need to be addressed prior to an application for a building permit.

SECTION METAL FLOOR PLATE STAIRS

SECTION SECTIONAL OVERHEAD DOORS

HORIZONTAL SLIDER SERIES 600 AAMA/WDMA/CSA 101/I.S.2/A Structural Performance: Thermal Break: C.R.F.: 50. Thermal U Value:.

Aluminum Flush Doors and Frames SPECIFICATIONS. Section [8120] PART 1 GENERAL

Guide Specifications. Metl-Span Architectural Insulated Metal Panel For Commercial & Industrial Buildings PART 1 GENERAL

LINEAR METAL CEILINGS Section

FIGURE R502.2 FLOOR CONSTRUCTION

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: METAL ROOF PANELS SECTION: METAL WALL PANELS REPORT HOLDER:

PROJECT LOCATION SECTION COPPER METAL PLATE WALL PANELS

MultiLok-24 Guide Specifications conforming to C.S.I. standards. A Division of ASC Profiles

SECTION HANGERS AND SUPPORTS FOR PLUMBING

1.2 Reference Standard: NOFMA - National Oak Flooring Manufacturers Association Grading Standards.

SECTION 1043 FENCE MATERIAL

SECTION TURBINE VENTILATORS

SECTION STAY-IN-PLACE INSULATED CONCRETE FORMING SYSTEM

CASEMENT PROJECT OUT SERIES 4400 AAMA/WDMA/CSA 101/I.S.2/A Structural Performance: Thermal Break: Main Frame Depth: 4

GENERAL SPECIFICATIONS

SECTION FIBERGLASS REINFORCED POLYMER (FRP) PANELS

Light-Metal Roof Edge, Raised

KS SERIES - VERTICAL INSTALLATION

Hansen Pole Buildings Planning Guide. Toll Free / Toll Free FAX

SECTION ALUMINUM WINDOWS

PRESTON HEALTH SERVICES ARCHITECT'S NO. 2700

Floor Insulation Underlayment Section Sound Control Matting

Daytona Beach Pier Building Renovation Jun 2010

MASTERSPEC TECHNICAL SPECIFICATIONS DIVISION 08 - OPENINGS. A. This Section includes fixed and operable aluminum-framed windows.

1.1 SECTION INCLUDES A. Insulated Metal and FRP Wall and Ceiling Panels and Related Accessories.

BEARING METAL STUD FRAMING

Louis Armstrong New Orleans International Airport NOAB Project # North Terminal Development Program Phase 1

by Rollfab Metal Products

DIVISION XIII - SPECIAL CONSTRUCTION

SECTION ROOF SPECIALTIES

ALL-ALUMINUM DOOR & WINDOW FRAMING

A. Product Data: For each type of deck, accessory, and product indicated.

SECTION NON-STRUCTURAL METAL FRAMING

AMBICO Limited Section and RFI\EMI SHEILDED STEEL DOOR AND FRAME ASSEMBLIES Page 1

Transcription:

SECTION 13125 FRAME BUILDING SYSTEM PART 1 GENERAL 1.01 SUMMARY A. Section Includes: Primary and secondary wood structural framing systems, roofing and wall covering systems, roof and wall insulation, personnel doors, windows, and accessories. B. Products Supplied But Not Installed Under This Section: 1. Bent reinforcing bar column anchors. C. Related Sections: 1.02 DEFINITIONS 1. Section 03300, Cast-in-Place Concrete 2. Section 08100, Metal Door and Frames 3. Section 08200, Interior Wood Doors 4. Section 08360, Sectional Overhead Door 5. Section 08700, Hardware A. Drawings: Contract documents prepared by the Engineer. B. Erection Drawings: Detailed project drawings prepared by the building manufacturer. C. Primary Framing: Pre-fabricated wood columns and pre-fabricated wood trusses including corner and endwall columns and trusses with required fasteners. D. Secondary Framing: Wood purlins, girts, splashplank, and bracing. 1.03 SYSTEM DESCRIPTION A. Design Requirements: 1. Building Code: ICBO, Uniform Building Code, 2006 Edition. FRAME BUILDING SYSTEM 13125-1

1.04 SUBMITTALS 2. Design Loads: a. Roof Load: Snow load: 30 psf b. Dead Loads: Truss top chord: 5 psf Truss bottom chord: 10 psf c. Wind Load: Wind speed: 80 mph Exposure factor: C d. Seismic Load: Seismic zone: II e. Collateral Loads: Additional loads imposed by contract documents other than weight of building systems specified in this section. f. Combination Loads: Comply with Building Code. 3. Structural Design: a. Perform calculations using diaphragm design analysis. Incorporate bracing as required if building exceeds diaphragm requirements. b. Comply with AF&PA National Design Specification for Wood Construction (NDS). c. Trusses: 1) Limit deflection for live or snow loads to L/360 for trusses supporting future ceilings. 2) Comply with appropriate NDS and Truss Plate Institute (TPI) standards. d. Metal Roof and Wall Panels: 1) Design in accordance with AISI Specifications for the Design of Light-Gauge, Cold-Formed Steel Structural Members and in accordance with sound engineering methods and practices. 2) Design to support a 200 pound load evenly distributed over a 2 foot square area centered between purlins; limit deflection to L/180 in a two-span condition. A. Reference Section 01300 Submittal Procedures. B. Submit following items: 1. Product Data: Include manufacturer s specifications and installation instructions for building components and accessories. 2. Shop Drawings: Erection Drawings showing roof framing, cross sections, roof and wall covering and trim details and accessory and component details clearly indicating proper assembly. 3. Samples: Standard color range for materials requiring color selection. 4. Quality Assurance/Control Submittals: a. Certificates: 1) Structural Engineer Certification of compliance with Design Requirements. 2) Manufacturer qualification. FRAME BUILDING SYSTEM 13125-2

1.05 QUALITY ASSURANCE 3) Dealer qualification. 4) Installer qualification. A. Qualifications: 1. Manufacturer Qualifications: Minimum five years experience in producing pre-engineered wood buildings of the type specified. 2. Dealer Qualifications: Must be manufacturer authorized dealer; state date authorization granted and expiration if any. 3. Installer Qualifications: Minimum one year experience in erection of preengineered wood buildings of the type specified. B. Structural Engineer Certification: Letter signed by a Professional/Structural Engineer, registered to practice in the state of Colorado verifying compliance with specified Design Requirements. Letter must reference specific dead loads, live loads, wind loads, tributary area load reductions (if applicable) collateral loads, seismic loads, end use categories, and governing building code including edition and load applications. C. Trusses: 1. Comply with TPI Design Specification for Metal Plate Connected Wood Trusses and Quality Standard for Metal Plate Connected Wood Trusses. 2. Manufacturer shall have a third party inspection program to verify compliance with requirements of TPI. 3. Stamp trusses with inspection agency identification. 1.06 DELIVERY STORAGE AND HANDLING A. Follow manufacturer s instructions. 1.07 WARRANTY A. Special Warranty: 1. Treated Wood Columns: Minimum 40 years against decay and insect damage when in contact with soil. 2. Steel Panels with painted finish: 20 years under normal weather and atmospheric conditions against: a. Crack, check, peel, flake, blister, or loss of adhesion of paint coating. b. Chalk of paint coating in excess of an 8 rating per ASTM D 4214. c. Fade of paint coating in excess of 5 units of color per ASTM D 2244. FRAME BUILDING SYSTEM 13125-3

PART 2 PRODUCTS 2.01 STRUCTURAL FRAMING A. Primary Framing: 1. Columns: a. Treated Lumber Section: 1) Lumber: No. 1 or Better Southern Yellow Pine, pressure treated with Chromated Copper Arsenate, Type III, to a retention of 0.6 pcf and kiln dried after treating to 19 percent maximum moisture content. 2) Fabrication: Laminate individual pieces using treated lumber ring shank or wire feed nails per manufacturer s engineered nailing pattern. b. Untreated Lumber Section: 1) Lumber: Lumber: No. 1 or Better Southern Yellow Pine or Douglas Fir-Larch kiln dried to 19 percent maximum moisture content. 2) Fabrication: Laminate individual pieces using ring shank or wire feed nails per manufacturer s engineered nailing pattern. c. Connection of Treated and Untreated Sections: Factory fabricated finger joint. d. Configuration: 1) Sidewall and Endwall Columns: 3 ply or 4 ply combining 2x6, 2x8, or 2x10 dimension lumber as required by Structural Design requirements specified herein and configured to accept interlocking girts and splashplank. 2) Corner Columns: 2 ply or 3 ply 2x6 or 2x8 dimension lumber as required by Structural Design requirements specified herein and configured to accept interlocking girts and splashplank from side and endwall directions. e. Column Anchor Reinforcing Bars: ASTM A 615, deformed, U- shaped bars, size as required by Structural Design requirements as specified herein. 2. Trusses: Comply with Structural Design and Quality Assurance requirements as specified herein. B. Secondary Framing: 1. Purlins and Girts: a. Lumber: No. 2 or Better dimension lumber kiln dried to 19 percent maximum moisture content. b. Configuration: 2x4 or 2x6 as required by Structural Design requirements specified herein. 1) Girts: Precision cut to fit. 2) Purlins: Precision cut to fit between trusses flush with top FRAME BUILDING SYSTEM 13125-4

of top chord. Provide 20 gauge galvanized purlin saddle hangers. c. Spacing: As required by Structural Design requirements specified herein. 2. Splashplank: a. Lumber: No. 2 or Better Southern Yellow Pine, pressure treated with Chromated Copper Arsenate, Type III, to a retention of 0.6 pcf and kiln dried after treating to 19 percent maximum moisture content. b. Configuration: 2x8 tongue and groove dimension lumber precision cut to fit between and interlock with columns. 3. Bracing, Wall and Lateral Truss Type (where required by Structural Design ): a. Lumber: No. 2 or Better dimension lumber. b. Configuration: 2x4 or 2x6 as required by Structural Design requirements specified herein. 2.02 STEEL ROOF PANELS A. Panel Description: 1. Material and Finish: a. 29 gauge ASTM A 792, Structural Quality, Grade 80 (550) (formerly Grade E), GALVALUME steel with AZ55 (AZ165) aluminum-zinc coating both sides, Triple-Spot Test. 2. Configuration: a. Roll-formed; 36 inch coverage width. Provide panels covering up to 38 foot-9 inch lengths in single pieces. b. Four major corrugations, 1-1/2 inches high, spaced 12 inches on center with 2 minor vee corrugations, 1/8 inch high, spaced 4 inches on center between each major corrugation. c. Form one outboard corrugation as overlapping corrugation. d. Form opposite outboard corrugation as underneath corrugation with continuous sealant groove. e. Factory cut to required length. B. Fasteners: Color coated No. 10 drill screws with 1/4 inch (6 mm) hex head preassembled to 1/2 inch o.d. dome seal or bond seal galvanized steel and EPDM washers. C. Accessories: 1. Provide manufacturer s standard pre-engineered ridgecap, flashings and eave and gable trim. Field fabricate minor flashings as shown on Erection Drawings. 2. Provide manufacturer s gutters and downspouts as shown on Drawings. 3. Closure Strips: Closed cell, 2 pcf density polyethylene foam, premolded to match configuration of panels. FRAME BUILDING SYSTEM 13125-5

4. Material and Finish: As shown on Erection Drawings. 2.03 STEEL WALL PANELS A. Panel Description: 1. Material and Finish: a. 29 gauge, ASTM A 653, Structural Quality, Grade 33 (230), galvanized steel with G90 (Z275) zinc coating. b. Exterior Surface Finish: Bonderize and provide on primer and (fluoropolymer) finish coat, 0.9 mil (0.023 mm) minimum dry film thickness. 1) Color: As selected by Owner from Manufacturer s standard color range. c. Interior Surface Finish: Manufacturer s standard polyester color coat. 2. Configuration: a. Roll-formed; 36 inch coverage width. Provide panels covering up to 38 foot-9 inch lengths in single pieces. b. Four major corrugations, 1-1/2 inches high, spaced 12 inches on center with 2 minor vee corrugations, 1/8 inch high, spaced 4 inches on center between each major corrugation. c. Factory cut to required length. B. Fasteners: Color coated No.10 drill screws with 1/4 inch hex head pre-assembled to 1/2 inch o.d. dome seal or bond seal galvanized steel and EPDM washers. C. Accessories: 1. Provide manufacturer s standard pre-engineered wall trim and flashings. Field fabricate minor flashings as shown on Erection Drawings. 2. Closure Strips: Closed cell, 2 pcf density polyethylene foam, premolded to match configuration of panels. 3. Material and Finish: As shown on Erection Drawings, except as specified herein. 2.04 INSULATION A. Tempshield Single Bubble, Double Foil Insulation: 1. Thermal Resistance: R-4.19. 2. Physical Properties: a. One layer of 5/32" barrier bubble film laminated between two layers of foil B. ASTM C 665, Type II, Class C, Kraft Faced Fiberglass Blanket: 1. Thermal Resistance: R-11. 2. Physical Properties: a. Water Vapor Transmission, ASTM E 96: FRAME BUILDING SYSTEM 13125-6

2.05 PERSONNEL DOORS 1.00 Perm (57.45 ng/(pa s m²) or less. A. Series 20 pre-hung and pre-finished door and frame system as manufactured by Plyco Corporation (or equal) including 16 gauge steel jambs, aluminum header and threshold, 1-1/2 inch thick door with 24 gauge steel faces, polyurethane foam core and full perimeter adjustable weatherstrips. 1. Door Style: a. Full Flush Panel. B. Finish: Bronze baked enamel. C. Hardware: Commercial grade cylindrical lock and hinges w/ Bronze finish.. 2.06 JOINT SEALANT MATERIALS A. Sealant: ASTM C 920, Type S, Class 25, Grade NS. 1. Color: Clear. PART 3 EXECUTION 3.01 EXAMINATION A. Verify that site conditions are acceptable for erection/installation of preengineered wood building system. B. Coordinate with responsible entity to perform corrective work on unsatisfactory conditions. C. Commencement of work by erector/installer is acceptance of site conditions. 3.02 ERECTION STRUCTURAL FRAMING A. Erect in accordance with manufacturer s instructions and approved shop drawings. B. Provide temporary erection and wind load bracing to maintain structure plumb and in alignment until installation of permanent bracing and/or roofing and wall coverings are completed. C. Do not field cut or alter structural members without approval of manufacturer. FRAME BUILDING SYSTEM 13125-7

3.03 INSTALLATION A. Metal Roofing: 1. General: Install in accordance with manufacturer s instructions. Secure to structural framing aligned, level and plumb. Space fasteners as shown on manfactures erection drawings. 2. Sidelap: Minimum one full corrugation. 3. Endlap: 12 inches for slopes less than 4 in 12. Secure together over and to structural members. 4. Accessories: Install as shown on manfactures erection drawings. B. Metal Siding: 1. General: Install in accordance with manufacturer s instructions. Secure to structural framing aligned, level and plumb. Space fasteners as shown on manfactures erection drawings. 2. Sidelap: Minimum one full corrugation. 3. Field cut endwall panels to match roof slope. 4. Accessories: Install as shown on manfactures erection drawings. C. Insulation: Follow manufacturer s instructions for the type(s) of insulation specified. 1. Insulation with tabs: Overlap tabs and secure to provide continuous vapor barrier. 2. Fill miscellaneous voids and cavity spaces to ensure continuously insulated envelope. D. Personnel Doors: Follow manufacturer s instructions. E. Windows: Follow manufacturer s instructions. F. Joint Sealant Materials: 1. Preparation: Clean joints and surfaces to receive sealants of foreign materials. 2. Apply sealant with caulking gun using sufficient pressure to completely fill joints and ensure full contact of sealant to joint sides. 3. Toll surface smooth and uniform, free of ridges, sags and air pockets. 4. Clean sealant from adjacent surfaces. 3.04 CLEANING A. Clean surfaces soiled by work as recommended by manufacturer. B. Touch up abrasions and other defects on pre-painted metal panel surfaces with same type of primer and paint as original finish. C. Remove surplus material and debris from site. FRAME BUILDING SYSTEM 13125-8

END OF SECTION FRAME BUILDING SYSTEM 13125-9