Channel FlexTM P-BD Series

Similar documents
Recyclex TRM TURF REINFORCEMENT MAT SPECIFICATION

AEC Premier Straw Double Net Quick Mow EROSION CONTROL BLANKET SPECIFICATION

A.2.a Random Riprap... Table

SECTION REINFORCING STEEL

Curlex II EROSION CONTROL BLANKET SPECIFICATION

Curlex High Velocity EROSION CONTROL BLANKET SPECIFICATION

SECTION 1100 GRADING 1102 MATERIALS AND DEFINITIONS.

GABIONS AND REVET MATTRESSES

CW 3615 RIPRAP TABLE OF CONTENTS

Section ( ) SPECIFICATION FOR SEGMENTAL CONCRETE UNIT RETAINING WALL

Wall Modular Block Mechanically Stabilized Earth, Item S.

STANDARD SPECIFICATION FOR CRIBLOCK CONCRETE CRIBWALL

ENGINEERED SOLUTIONS. ArmorFlex Installation Guide

SECTION INTERLOCKING PRECAST CONCRETE UNIT PAVERS

Specifications for the Selection and Application of Erosion Control Blanket on Slopes or Channels

A. This Section includes subdrainage systems for foundations and underslab areas. A. Product Data: For each type of drainage panel indicated.

GEOSYTHETIC SLOPE SPEC-V0704rev.doc STANDARD SPECIAL PROVISION FOR GEOSYNTHETIC REINFORCED SLOPE CONSTRUCTION

FRP REBAR: MDOT APPROVED

SPECIAL SPECIFICATION 4900 Sacrificial Cathodic Protection Pile Jacket

MODULAR CONCRETE RETAINING WALL

PRODUCT SPECIFICATION CSI FORMAT Slope and Channel Grid Systems April 2009

SECTION 806 WATER COURSE AND SLOPE EROSION PROTECTION

A. Product Data: Submit manufacturer s product data, with complete general and specific installation instructions, recommendations, and limitations.

SPECIFICATION FOR REINFORCED SOIL WALL

CONCRETE SEGMENTAL RETAINING WALL SYSTEM

SPECIFICATIONS FOR PRECAST MODULAR BLOCK RETAINING WALL SYSTEM (revised 5/8/7)

MODEL SPECIFICATIONS: Hydraulically Driven Steel Underpinning Pile Specifications

CONCRETE STEPS, HANDRAILS, AND SAFETY RAIL

STANDARD SPECIFICATIONS SECTION BORING AND JACKING. A. Section includes requirements for boring and jacking casing pipe.

ARMORMAX ENGINEERED EARTH ARMORING SOLUTIONS

INDEX FOR SPECIFICATIONS FOR REMOVING CULVERTS AND PLACING CULVERTS SCOPE... 1

ITEM D-701 PIPE FOR STORM DRAINS AND CULVERTS

SECTION RIPRAP, BOULDERS, AND BEDDING

SECTION SPECIFICATION FOR STONEBRIDGE RETAINING WALL SYSTEM

SECTION UTILITY MANHOLES AND STRUCTURES

Section (02830) MODULAR CONCRETE RETAINING WALL

Description. This work shall consist of furnishing materials and placement of modular block wall constructed in accordance with

SPECIFICATION FOR PREFABRICATED VERTICAL DRAINS

SECTION CHAIN LINK FENCES AND GATES (PARK)

SECTION PERMEABLE INTERLOCKING CONCRETE UNIT PAVEMENT

Pulaski County, Virginia

EXPANDED POLYSTYRENE (EPS GEOFOAM) EMBANKMENT DIVISION 31 EARTHWORK

CONSTRUCTION STANDARDS SECTION CS 3 TRENCH FOUNDATION, BEDDING AND BACKFILL

Section 1I-3 - Bioswales

G. Shop drawing of wall with all dimensions, details, and finishes. Drawings must include post foundations.

02800 SHADE STRUCTURES

SPECIFICATIONS FOR BRIDGE CONSTRUCTION SECTION 5 REINFORCING STEEL. 5.1 General Certification Fabrication...

E. Section Polymer Modified Cement Waterproofing. K. Section Sub drainage: Foundation perimeter drainage.

ADDENDUM No. 6. ITB No. 4424: W.R. Wheeler (Swift Run) Service Center PUD Non-motorized Improvements Phase 1

MANHOLES, VAULTS AND CATCH BASINS SECTION A. Section Soil and Aggregate Materials. C. Section Storm Drainage Systems

STATE OF OHIO DEPARTMENT OF TRANSPORTATION SUPPLEMENTAL SPECIFICATION 836 SEEDING AND EROSION CONTROL WITH TURF REINFORCING MAT January 18, 2013

SECTION 716 SIGN MATERIALS SCOPE

1 Exam Prep Placing Reinforcing Bars Tabs and Highlights

SECTION C1 DUCTILE IRON PIPE AND FITTINGS GENERAL

Hydrodynamic Separation Product Calculator

ITEM 460 REINFORCED CONCRETE PIPE Description. This Item shall govern for the furnishing of reinforced concrete pipe.

Section 906. STRUCTURAL STEEL

PERMEABLE ARTICULATING CONCRETE BLOCK (P-ACB) SPECIFICATION FOR PARKING LOTS, DRIVEWAYS, ALLEYS AND ROADWAYS

LANDSCAPE RETAINING WALLS

PAVING SLABS ON A CONCRETE BASE

SUGGESTED MANHOLE FRAME SEALING SPECIFICATION (Rehabilitation)

SECTION 19 - TRENCH EXCAVATION, BEDDING AND BACKFILL TABLE OF CONTENTS

Stream Channelization, Before and After ACB Installation

Section 2 Supplemental Specification 2.11 High Tension Cable Barrier

Recommended Specifications For Portland Cement Pervious Pavement

SECTION CHAIN LINK FENCES AND GATES (GALVANIZED) A. Fence framework, fabric, gates, and accessories.

SECTION BASIC ELECTRICAL MATERIALS AND METHODS

BMP 6.4.4: Infiltration Trench

1. Cast-in-place concrete is specified in Section

SECTION 19 - TRENCH EXCAVATION, BEDDING AND BACKFILL TABLE OF CONTENTS

Section 401. PIPE CULVERTS

STATE OF OHIO DEPARTMENT OF TRANSPORTATION SUPPLEMENTAL SPECIFICATION 863 REINFORCED SOIL SLOPES. October 19, 2012

REVISED SECTION REINFORCING STEEL FOR CONCRETE STRUCTURES. Approved:

1.02 STANDARD REFERENCES: The following standard specifications shall apply to the Work of this Section as indicated:

CONSTRUCTION SPECIFICATION FOR KEYHOLE EXCAVATION AND PERMANENT REINSTATEMENT OF KEYHOLE CORES TABLE OF CONTENTS

Bi-Directional Static Load Testing of Drilled Shafts

SLAB ON GRADE Insul-Joint or Expansion Joint Material as Required by A/E Specifications AquaCheck Liquid Coating 400 (Waterproofing Membrane) with Aqu

ACCEPTANCE CRITERIA FOR THREADED HIGH-STRENGTH STEEL BARS FOR CONCRETE REINFORCEMENT PREFACE

A. The extent of extruded aluminum walkway covers is shown on the Drawings and as specified herein.

SECTION CAST-IN-PLACE CONCRETE

Section [ ] Storm Water Treatment Device

SECTION 39 - MANHOLES TABLE OF CONTENTS 39-1 GENERAL PRECAST CONCRETE MANHOLES

SECTION 941 PRECAST REINFORCED CONCRETE BARRIERS

ENGINEERING SPECIFICATION. PULTRUDED PEDESTRIAN FIBERGLASS GRATING SAFE-T-SPAN T1210 VINYL ESTER and ISOPHTHALIC. October 25, 2004 Revision 1

SECTION STAY-IN-PLACE INSULATED CONCRETE FORMING SYSTEM

SAMPLE GUIDE SPECIFICATIONS FOR OSTERBERG CELL LOAD TESTING OF DRILLED SHAFTS

SECTION ROOF SPECIALTIES

SECTION INTERLOCKING CONCRETE PAVERS

Flotation Docking Systems, Inc.

Construction Inspection Checklists

SECTION STRUCTURAL PRECAST HOLLOW CORE SLABS

SECTION FLEXIBLE PAVING


***************************************************************************************************************

INDEX FOR SPECIFICATIONS FOR JACKING CULVERTS THROUGH EMBANKMENTS SCOPE... 2

STANDARD SPECIFICATIONS SECTION TUNNELING. A. Section includes requirements for constructing tunnels 48-inch and larger diameter.

ICC-ES Evaluation Report Issued July 1, 2011 This report is subject to renewal in one year.

DESIGN CONSIDERATIONS FOR NSWS NATURAL STONE RETAINING AND FREE-STANDING WALL SYSTEMS

SECTION 1043 FENCE MATERIAL

Transcription:

Channel FlexTM P-BD Series Class 475 Closed Cell 4.75 Cellular Concrete Block Mat System

TABLE OF CONTENTS FOR ARTICULATED CONCRETE BLOCK REVETMENT PARAGRAPH PARAGRAPH TITLE PAGE PART 1 - GENERAL 1.1 DEFINITIONS 01 1.2 REFERENCES 01 1.3 DELIVERY, STORAGE AND HANDLING 01 1.4 MEASUREMENT 01 2.1 ARTICULATED CONCRETE BLOCKS 02 2.2 CABLE 02 2.3 FILTER FABRIC 03 2.4 FOUNDATION PREPARATION 03 2.5 INSTALLATION OF CELLULAR CONCRETE MATS 04 2.6 FINSHING 05 2.7 CONTRACTOR QUALITY CONTROL 05

1.1 DEFINITIONS: This work shall consist of furnishing and installing Channel Flex R Class 475 Cellular Concrete Mat System in accordance with lines, grades design and dimensions shown on the drawings. The Cellular Concrete Blocks shall be interlocking and have penetrations in the blocks for revetment cables as necessary to bind the individual blocks into mattresses in both the longitudinal and lateral directions. Cable penetrations shall prevent any exposure to potential UV degradation within the dimensions of the individual blocks. The mat system shall be in accordance with the lines, grades, design and dimensions shown on the plans and be able to articulate when formed into mattresses. 1.2 REFERENCES: Channel Flex meets or exceeds specifications with regards to the publications listed below. The publications are referred to in the text by the basic designations only. American Society for Testing and Materials (ASTM) Publications. ASTM C 33-97 ASTM C 140-91 ASTM A 153/A 153M ASTM A 36/A 36/M ASTM C 42/C 42M Concrete Aggregates Sampling and Testing Concrete Masonry Units Standard Specification for Zinc Coating (Hot Dip) on Iron and Steel Hardware Standard Specification for Carbon Structural Steel Standard Test Method for Obtaining and Testing Drilled Cores and Sawed Beams of Concrete US Federal Highway Administration (FHWA) and US Bureau of Reclamation (USBR) FHWA RD-89-199 Hydraulic Stability of Articulated Concrete Block Revetment Systems During Overtopping Flow. 1.3 DELIVERY, STORAGE AND HANDLING OF MATERIALS: Materials delivered to the site will be inspected for damage, unloaded and stored with a minimum of handling. Contractor may designate a storage site at the project for materials to be delivered and stored prior to placement if needed. Storage site to be approved by the Contracting Officer, if necessary. Materials shall not be stored directly on the ground and shall be kept free of dirt and debris. Materials shall be so handled as to ensure delivery to the site in sound undamaged condition. Synthetic geotextiles that are not to be installed immediately shall be protected from the direct sunlight in accordance with the SECTION entitled GEOTEXTILES. 1.4 MEASUREMENT: Unit of measurement and payment for the Articulated Cellular Concrete Mats will be by the square foot or as per the specifications.

2.1 ARTICULATING CONCRETE BLOCKS: Page 1 Hydraulic Test Data and block performance according to FHWA-RD-89-199 shall be provided to the Engineer. The cellular concrete block system must have been tested under controlled flow conditions for hydraulic performance utilizing a 2:1 slope in the direction of flow. Channel Flex Class 475according to FHWA RD-89-199 meets the following minimum requirements: Closed Cell Block Without Cables as Tested on Soil Embankment with Geotextile Filter Fabric. (No Drainage Layer Utilized During Testing - 4 Gravel or Synthetic Matting). Surface Void Ratio 8% Critical Velocity FPS 22.2 ft/sec Critical Shear Stress Lbs/Ft 2 15.6 Lbs. Block Weight per Unit, Minimum 78 Lbs Block Thickness: 4.75 2.1.1 Matrix Assembly Cabled Systems The Channel Flex System shall be pre-assembled into mattresses as an assembly of concrete blocks when connected into mattresses by the use of revetment cables. Individual blocks may be installed at the site in the dry and the revetment cables threaded through the blocks to bind the entire system by the use of revetment cables. Two (2) integral longitudinal cables per block are required as well as one (1) lateral transverse cable. The pre-assembled mats revetment system must be tied continuously throughout with cables in both the llongitudinal and lateral directions. 2.1.2 Structural Requirements: The compressive strength of the concrete blocks will be a minimum of 4000 PSI at 28 days. The core compressive strength shall not be less than the minimum and test cores shall be tested at the engineer s option. Test procedures shall be in accordance with ASTM C 140-91. Cores failing to meet the minimum compressive strength requirements shall be cause for rejection of the represented lot by the engineer. The maximum water absorption will be 10 pcf for an average of 3 units, and 12 pcf for an individual unit. Water absorption will be determined according to ASTM C 140. The minimum saturated surface-dry density will be 130 pcf for an average of 3 units. 2.1.3 Aggregate: The aggregate shall meet the requirements of ASTM C 33-97, except for grading. Aggregate grading shall be reasonably consistent and shall be well-graded from the maximum size which can be conveniently handled with available equipment 2.2 CABLE: Cable shall be constructed of high tenacity, low elongation and continuous filament polyester fibers. Cables shall consist of a core construction comprised of parallel fibers contained within an outer jacket or cover. The weight of the parallel core shall be between 65 to 70 percent of the total weight of the cable. The revetment cable shall have the following minimum physical properties: Page 2

Nominal Longitudinal Cable Diameter: 20 mm Approximate Strength Lbs. 3,700 Weight Yield 2.5/100 ft. 2.41 The revetment cable shall exhibit good to excellent resistance to most concentrated acids, alkalis and solvents. Cable shall be impervious to rot, mildew and degradation associated with marine organisms. The materials used in the construction shall not be affected by continuous immersion in fresh or salt water. 2.42 Selection of cable and fittings shall ensure a safe design factor for mattresses being lifted from both ends, thereby forming a catenary. Consideration shall be taken for the bending of the cables around hooks or pins during lifting. Revetment cable splicing fittings shall be selected so that the result splice shall provide a minimum of 75 percent of the minimum rated cable strength. Fittings such as sleeves, stops and washers shall be in accordance with manufacturer s recommendations unless otherwise shown. 2.43 Elongation Requirements: Requirements listed below are based upon stabilized new and dry cable. The tolerance of these values is plus or minus 5 percent. % Breaking Strength 10% 20% 30% Permanent Elongation 0.7 1.8 2.6 (While Working) Elastic Elongation 0.6 1.4 2.2 Total Stretch 1.3 3.2 4.8 2.3 FILTER FABRIC: The filter fabric used for cellular concrete blocks shall be in accordance with the SECTION entitled GEOTEXTILES. 2.4 FOUNDATION PREPARATION: Areas on which filter fabric and cellular concrete blocks are to be placed shall be constructed to the lines and grades shown on the plans and in accordance with the specifications. 2.4.1 Perimeter: Excavation and preparation for anchor trenches, side trenches, toe trenches and aprons shall be done in accordance to the lines, grades and dimensions shown on the plans. 2.4.2 Inspection: Immediately prior to placing the filter fabric and cellular concrete blocks, the prepared area shall be inspected by the Contractor and approved before the fabric or blocks are placed thereon. Page 3

2.5 INSTALLATION OF CELLULAR CONCRETE MATTRESSES: 2.5.1 Filter Fabric: Placement of filter fabric shall be installed in accordance with the SECTION entitled GEOTEXTILES or as stated herein. 2.5.2 Placement of Cellular Concrete Mats: Cellular concrete mats shall be placed within the limits shown. The cellular concrete mats shall be placed on the filter fabric in such a manner as to produce a level surface. Cable used for preassembled mattresses shall be sufficiently sized and fastened for the size/weight of the assembled mattresses such that the assembled mattresses can be placed in compliance with OSHA standards. The mattresses will be placed with a maximum space or gap of 2 inches in excess of the nominal joint spacing of the blocks within the mattress. No overlapping of mats will occur and blocks will not protrude more than.50 inches beyond the adjacent blocks for installations in the dry. As adjacent mats are placed, each row of blocks within the mats hall they will be secured by fastening the protruding horizontal cable connections together along each side of the mats. Individual blocks which are hand placed shall be subject to the spacing and level parameters as stated in Placement of Cellular Concrete Mats. Revetment cables shall be threaded into the blocks as the placement proceeds and fastened with approved sleeves, fittings or fasteners. Extended lengths or runs of cable threaded into the blocks will be permitted provided the connections of cables are fastened with approved sleeves, fittings, or fasteners. Individual blocks hand placed must have two (2) longitudinal cables and one (1) transverse cable per each block per the SPECIFICATIONS. The Contracting Officer will require uncovered fabric to be lifted after heavy rainfall to inspect for slope damage. The Contractor and Owner shall discuss subgrade preparation, geotextile and cellular block placement at the pre-construction meeting to ensure that all parties are aware of the issues regarding installation. The Contractor shall furnish a certificate from the manufacturer or an authorized representative thereof stating that the blocks were installed correctly. Final acceptance and approval of the installation will be made by the Contracting Officer. 2.5.3 Quality Control: Equipment shall be minimized on the installed concrete blocks until backfill or topsoil is placed over the revetment system to refrain from breaking or damaging any blocks. Any blocks broken or damaged shall be repaired prior to final inspections. 2.5.4 Grouting: Any areas where there are partial blocks (to avoid small blocks with reduced hydraulic stability) shall be grouted. Joints where block interlock is discontinuous shall be grouted. Joints between cabled tied mattresses where the joint exceeds 2 inches shall be required to be grouted. Field placed grout shall be non-shrink and have a compressive strength of 4,000 psi, the durability properties of the ACBM concrete, and shall meet the ACBM manufacturer s requirements. All cable ties and anchoring shall be completed prior to placing the grout. 2.6 FINISHING: 2.6.1 The voids of the cellular concrete blocks for the limits shown shall be filled with topsoil and seeded for revegetation or gravel per the specifications. Prior to backfill, the blocks surface shall be inspected for damage. Individual blocks which are cracked and do not meet the specifications shall be replaced prior to the placement of backfill.

Page 4 2.7 CONTRACTOR QUALITY CONTROL: 2.7.1 The Contractor shall inspect for compliance with contract requirements and record the inspection of operations including but not limited to the following as applicable: (1) Preparation of surface to receive cellular concrete blocks or mattresses. (2) Individual concrete blocks and filter fabric soundness and free of defects. (3) Cables and fittings - breaking strength. (4) Assembly of cellular concrete blocks bound by cables to form cellular concrete mattresses. (5) Placement of blocks or mattresses and filter fabric on the prepared subgrade. (6) Individual blocks hand placed and cables hand threaded. (7) Embedment of cables in the anchor trenches, side trenches and toe trenches. (8) Tie-in to existing structures such as concrete, pipes, etc.

Page 5