Attachment of Exterior Wall Coverings Through Polyiso to Wood or Steel Wall Framing

Similar documents
6300 Enterprise Ln Madison, WI

Guide to Attaching Exterior Wall Coverings through Foam Sheathing to Wood or Steel Wall Framing

TSX Insulation for Exposed Use ROOF WALL SPECIALTY

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: THERMAL INSULATION SECTION: WATER-RESISTIVE BARRIERS/WEATHER BARRIERS

Pella 250 Series. Wood Frame Construction with Vinyl Siding... V250-ID-888 Wood Frame Construction with Brick Veneer...

REPORT HOLDER: R.L. ADAMS PLASTICS, INC CROSSROADS COMMERCE PARKWAY WYOMING, MICHIGAN EVALUATION SUBJECT: POLYCORE BRAND INSULATION

REPORT HOLDER: THE DOW CHEMICAL COMPANY 1501 LARKIN CENTER DRIVE MIDLAND, MICHIGAN EVALUATION SUBJECT:

TER No Cultured Stone & ProStone Applications Over Continuous Insulation

DuPont RainVent Batten Installation Guidelines

INSTALLATION MANUAL. ZIP System R12 Sheathing. Contents. 07 ZIP System R12 Sheathing Window Installation 08 ZIP System R12 Sheathing Siding Guidelines

Thermasheath-XP. Insulation for Exposed Use

application instructions

Figures 1A-1C Light frame and mass wall systems with continuous insulation for codecompliant. commercial building construction.

ICC-ES Evaluation Report Reissued March 2014 This report is subject to renewal March 1, 2015

Gold Bond BRAND Gypsum Sheathing

KNIGHT WALL SYSTEMS GUIDE DETAILS:

NOVABRIK MORTARLESS CONCRETE BRICK VENEER SPECIFICATION. MASTERFORMAT SECTION (Mortarless Concrete Brick Veneer)

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: PLASTIC SIDING REPORT HOLDER: ASSOCIATED MATERIALS, INC.

(Project Location) (your firm's name)

for New Construction Applications

KNIGHT WALL SYSTEMS GUIDE DETAILS:

ESR-1365 Reissued March 2014 This report is subject to renewal April 1, 2015.

Joint Evaluation Report ICC-ES (800) (562)

ESR-2894 Reissued April 2014 This report is subject to renewal April 1, 2016.

LP SmartSide Perfection Shingle

Eclipse Energy Guard. Product Information & Installation Manual General Installation Requirements

Thermasheath -3. Insulation for the Building Envelope ROOF WALL SPECIALTY

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: WATER RESISTIVE BARRIERS/WEATHER BARRIERS SECTION: AIR BARRIERS

SECTION REFLECTIVE-FACED, MASONRY CAVITY WALL INSULATION

DIVISION: WOOD, PLASTICS AND COMPOSITES SECTION: SHOP-APPLIED WOOD COATINGS SECTION: SHEATHING REPORT HOLDER:

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: COMPOSITE WALL PANELS REPORT HOLDER: PARKLEX USA

General. Moisture. Secondary Water-Resistive Barrier. Storage. Gaps & Sealants. Stud Spacing. Flashing, Windows, Doors & Openings

REPORT HOLDER: OMEGA PRODUCTS INTERNATIONAL, INC CALIFORNIA AVENUE CORONA, CALIFORNIA EVALUATION SUBJECT:

SECTION PRE-ENGINEERED BUILDING INSULATION

Code Compliance Research Report CCRR-0228

Attachment of Windows with Integral Flanges through Foam Plastic Insulating Sheathing to Wood Framing. TER No

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: COMPOSITE WALL PANELS REPORT HOLDER: ARCONIC ARCHITECTURAL PRODUCTS, LLC

Proper Installation of Insulated Metal Wall Panels

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: WATER RESISTIVE BARRIERS/WEATHER BARRIERS SECTION: AIR BARRIERS

TER No Use of FastenMaster HeadLOK TM Fasteners to Attach Cladding and/or Furring to Wood Framing through Foam Sheathing

INSTALLING WATER-RESISTIVE BARRIERS & FLASHING

NEXT GENERATION HIGH PERFORMANCE WALLS

Originally Issued: 12/12/2014 Revised: 12/29/2017 Valid Through: 12/29/2018

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: METAL ROOF PANELS SECTION: METAL WALL PANELS REPORT HOLDER:

SECTION 07530CP EPDM MEMBRANE ROOFING

SECTION A. ACSE 7 Minimum Loads for Buildings and other Structures.

REPORT HOLDER: AEROSMITH FASTENING SYSTEMS 5621 DIVIDEND ROAD INDIANAPOLIS, INDIANA EVALUATION SUBJECT: AEROSMITH BRAND FASTENERS

California Building Envelope Solutions

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: PLASTIC SIDING REPORT HOLDER: GENTEK BUILDING PRODUCTS, INC.

Details for Exterior Brick Masonry Veneer Supported by Metal Plate Connected Wood Trusses

EXCEL Medical Waste - Equipment Installation Section SECTION GYPSUM BOARD

The better way to build TM. Installation Manual FOUNDATION SIPs & FROST WALLS SIPs

A Simple Solution for Meeting

Exterior Stucco and Siding Installation

ELEVATION FOR DETAIL REFERENCE ONLY

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: COMPOSITE WALL PANELS REPORT HOLDER: FUNDERMAX GMBH

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: FIBER CEMENT SIDING REPORT HOLDER: RIEDER FASERBETON ELEMENTE GmbH

LUX Specifications. Section S - Preformed Steel Siding

INSULATION RETROFIT DESIGN ENERGY SOLUTIONS CENTRE YUKON GOVERNMENT

PER See all Pei ES Listings at:

WEB BASED APPLICATION SPECIFIC INSTALLATION INSTRUCTIONS

Trusted ICC ES DIVISION: ATLANTA, CGF PRO, ENERGYS. Look. Conformity! Evaluation. ICC-ES Evaluation

WEB BASED APPLICATION SPECIFIC INSTALLATION INSTRUCTIONS

SECTION GYPSUM BOARD ASSEMBLIES

Incorporating Insulating Sheathing into the Design of the Thermal and Moisture Management System of the Building Enclosure

Container Installation Guide

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: COMPOSITE WALL PANELS REPORT HOLDER: CITADEL ARCHITECTURAL PRODUCTS, INC.

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: FIBER-CEMENT SIDING REPORT HOLDER: EQUITONE

ACCEPTANCE CRITERIA FOR METAL PLASTER BASES (LATH) PREFACE

DIVISION: FINISHES SECTION: PORTLAND CEMENT PLASTERING REPORT HOLDER: PROWALL BUILDING PRODUCTS, INC.

FMA_AAMA_WDMA Installation Committee Update FMA Conference May 8, Naples, FL. Jim Katsaros FMA_AAMA_WDMA Installation Committee

REPORT HOLDER: JAMES HARDIE BUILDING PRODUCTS, INC ELM AVENUE FONTANA, CALIFORNIA EVALUATION SUBJECT:

2006 INTERNATIONAL ENERGY CONSERVATION CODE

MCCARTY ARCHITECTS, P.A. POST OFFICE BOX 440 / 533 WEST MAIN STREET TUPELO, MS / FOR ANSWERS TO QUESTIONS CONTACT: JUSTIN HARRINGTON

REPORT HOLDER: JAMES HARDIE BUILDING PRODUCTS INC ELM AVENUE FONTANA, CALIFORNIA EVALUATION SUBJECT:

REPORT HOLDER: LOUISIANA-PACIFIC CORPORATION 414 UNION STREET, SUITE 2000 NASHVILLE, TENNESSEE EVALUATION SUBJECT:

Integrated Air & Water Barrier Systems

Perimeter Relief and Control Joints in Fire-Rated Gypsum Board

4 EXTREME FOUNDATION PANELS

Wall bracing panel requirements

RAY-CORE Structural Insulated Roof and Wall Panels

Container Installation Guide

REPORT HOLDER: PAREX USA, INC EAST LA PALMA AVENUE, SUITE 250 ANAHEIM, CALIFORNIA EVALUATION SUBJECT:

REPORT HOLDER: GEORGIA PACIFIC GYPSUM LLC 2861 MILLER ROAD DECATUR, GEORGIA EVALUATION SUBJECT: DENSELEMENT BARRIER SYSTEM

Thermal Bridging in Residential Construction

STATE OF NEW HAMPSHIRE DEPARTMENT OF NATURAL AND CULTURAL RESOURCES DIVISION OF PARKS AND RECREATION SKI PATROL HUT PROJECT #: CAP 1804

HPW Protocol Reference Manual

CHAPTER 6 TYPES OF CONSTRUCTION

INSULATION OWENS CORNING INSULATION PRODUCTS IN THIS SECTION:

ESR ICC Evaluation Service, Inc. Issued November 1, 2003 This report is subject to re-examination in one year.

DIVISION: FINISHES SECTION: PORTLAND CEMENT PLASTERING REPORT HOLDER: ULTRAKOTE PRODUCTS, LLC

Quality Inspection 8618 London Heights San Antonio, TX Phone: (210)

DIVISION: FINISHES SECTION: PORTLAND CEMENT PLASTERING REPORT HOLDER: SOMAR INDUSTRIES LTD LUCKETT COURT EL PASO, TEXAS 79932

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: PLASTIC SIDING REPORT HOLDER: DERBY BUILDING PRODUCTS INCORPORATED

REPORT HOLDER: JOHNS MANVILLE TH STREET DENVER, COLORADO EVALUATION SUBJECT:

Shaftwall and Area Separation Wall Systems.

How do you install yours?

Sept 30, 2004 Page 1

Colorado Chapter of the International Conference of Building Officials. Building Guide. The Colorado Chapter of the International

MID-RISE DESIGN & CONSTRUCTION

Transcription:

Attachment of Exterior Wall Coverings Through Polyiso to Wood or Steel Wall Framing Installation Instructions Revised 10/25/2016

Scope For the 2015 IBC (cold-formed Steel) and IRC see ABTG Report No. 1503-02 For the 2015 IBC (wood framing) see DRR No. 1303-04 A proposal has been made in the 2018 code cycle. For the 2012 and earlier versions of the IBC and IRC see DRR No. 1303-04

Scope This presentation is based on the code language introduced in the 2015 IRC and IBC which is based on two key references available at the ABTG website: NYSERDA Fastening Systems for Continuous Insulation (2010) Baker/DOE Cladding Attachment Over Thick Exterior Insulating Sheathing (2014)

Polyiso Products Shall conform to ASTM C1289 Come in many thicknesses to accommodate almost any end use In this situation limited to 4 thickness Highest R-value per inch of any foam plastic insulating sheathing. Lightweight, easy to install. Easily cut to fit with a utility knife. Polyiso as continuous exterior insulation is seeing increased recognition in the market for compliance with the energy codes.

Attachment Methods Exterior wall coverings are attached directly through the Polyiso into the framing or to furring attached through the Polyiso to framing Polyiso installed in accordance with: DRR No. 1410-08 Manufacturer s installation instructions The following general installation guidelines

Step 1: Verify Polyiso and Framing Polyiso must have min. compressive strength of 15 psi Must comply with ANSI/SBCA FS100 where wind pressure resistance is required ASTM D 1621 Note: Wind speeds shown in Table 1 are V ASD. Where V ULT is used, multiply wind speeds by a factor of 1.26 _ + _

Step 1: Verify Polyiso and Framing Wood framing may be any softwood species with specific gravity 0.42 or higher Steel framing must be: Thickness Minimum F b 33 mil, 43 mil 33 ksi 54 mil 50 ksi F b

Step 2: Verify Fasteners Exterior coverings may be attached through Polyiso directly to structural members or through furring: (a) Cladding (b) Fasteners (c) Furring (d) Polyiso (e) Framing (f) Cavity Insulation (g) Interior wall finish (a) (d) (a) (c) (d) Direct Attachment Attachment through Furring (b) (b) (e) (f) (g) (e) (f) (g)

Step 2: Verify Fasteners Fasteners must meet penetration requirements per IRC 2015 Table R703.3(1) into: Framing Sheathing Where penetration into framing is not required, fasteners must extend ¼" beyond the opposite face of the sheathing per IRC 2015 R703.3.2 & Table R703.3.2 1¼ min or per manuf. instructions 1/4 min

Step 3: Place Insulation Boards Ensure wall is square and true Align boards with bottom edge of wall

Step 3: Place Insulation Boards Verify stud spacing, blocking, and bracing requirements with manufacturer Provide framing or blocking for attachment of siding and trim at transitions Seams should not be visible from interior unless allowed by manufacturer 16 o.c. (or per manuf.)

Step 4: Attach Insulation Boards Space fasteners per manufacturer s instructions Around edges of panel Through panels and into interior members Interior Spacing Edge Spacing

Step 4: Attach Insulation Boards Drive nails flush and snug Do not overdrive nails Do not underdrive nails Exception: Leave 1/32" gap (or as required by manufacturer) to allow for lengthwise thermal expansion of vinyl or aluminum siding

Step 5: Trim Boards at Openings Trim boards at all window and door openings Cover all framing with Polyiso Fit joints tightly Polyiso Continuous Insulation

Step 6: WRB and Flashing Ensure that a code compliant water-resistive barrier (WRB) and required flashing is provided If using Polyiso as a WRB: Seal all joints and openings and penetrations per manufacturer s installation instructions

Step 6: WRB and Flashing At pipe and other small penetrations, seal gaps with silicone or expanding spray foam sealant Seal joints and openings with joint tape per manufacturer s instructions Source: DOE Building America

Step 6: WRB and Flashing Repair damaged areas per manufacturer s instructions