BROCHURE # 108 CONSTRUCTION PLAN COMPONENTS

Similar documents
RESIDENTIAL NEW CONSTRUCTION PLAN REVIEW CHECKLIST

RESIDENTIAL BUILDING PLAN REQUIREMENTS

2003 International Residential Building Code

Administrative Changes

One and Two Family Additions

SCREEN PORCHES 101 DEVELOPMENT RESOURCES, INC Permit Requirements

Minimum Requirements For One & Two Family Structures FBC 6 th Edition (2017)

PENNSAFE BUILDING INSPECTION SERVICES LLC Deck and Roof Cross Section Submittal

ORDINANCE. APPROVED EMERGENCY: (Yes) (No) VETOED: Date

PENNSAFE BUILDING INSPECTION SERVICES LLC PERMIT APPLICATION

RESIDENTIAL CONSTRUCTION New Dwellings and Additions

CALIFORNIA COMMERCIAL BUILDING INSPECTOR CONTENT OUTLINE 01. GENERAL ADMINISTRATION 6% Project Administration 1%

Building Guide. Colorado Chapter of the International Code Council

Each proposed project will be reviewed for compliance with the following codes as applicable.

BASEMENT FINISH PERMIT AND BUILDING CODE REQUIREMENTS (REVISED 3/6/2018)

POST FRAME BUILDING STANDARDS

BUILDING CODES & DESIGN CRITERIA

General Residential Code Requirements

RESIDENTIAL BUILDING REQUIREMENTS

INTERIOR ENVIRONMENT

The Inspection Process. Waxhaw N.C.

Residential Accessory Structures & Room Additions

Applying for Permits to build a new house in Linn County

FACT SHEET #2 DECK INFORMATION

STRUCTURAL ISSUES IN RESIDENTIAL CONSTRUCTION. Presented by: Susan L. Lasecki P.E., S.E.

1 AND 2 FAMILY DWELLING REQUIREMENTS

City of Republic Community Development Girder and Header Spans for Exterior Walls

R vertical and horizontal.

CITY OF HAGERSTOWN PLANNING & CODE ADMINISTRATION DEPARTMENT. Submittal Requirements

R CODE CHANGE PROPOSAL FORM (See instructions on page 2)

ACCESSORY STRUCTURE Building permit information For 1 & 2-family dwellings

Table of Contents. Page Title

BASEMENT FINISH CONSTRUCTION PLANS REFERENCE: 2015 INTERNATIONAL RESIDENTIAL CODE. PERMITS

TOWN OF SOUTH KINGSTOWN REQUIREMENTS FOR BUILDING PERMITS RESIDENTIAL SINGLE FAMILY

CONSTRUCTION CODE PERMIT INFORMATION

130 MPH EXPOSURE B WFCM GUIDE. Guide to Wood Frame Construction in High Wind Areas for One- and Two-Family Dwellings 2015 EDITION

TOWN OF ROTTERDAM RESIDENTIAL BUILDING PERMIT APPLICATION Ext. 395 Needed to Obtain Permit:

Anchor bolts ASTM F1554, Gr. 36 Wide flange beams ASTM A992, Fy = 50 ksi Misc. structural steel ASTM A36, Fy = 36 ksi

Typical Finished Basement Details

R Code and Commentary for 2012 NC Residential Code final 03/06/13

HOUSE REPAIRS & RENOVATIONS BUILDING PERMIT REQUIREMENTS

City of Owatonna Residential Plan Submittal Checklist

The Homeowner s Building Application Checklist for Constructing a Residential Addition

HILLSBOROUGH TOWNSHIP CODE ENFORCEMENT

Residential Inspector s Guide: Building and Energy based on the 2009 International Residential Code Chapters 1-11

Residential Inspector s Guide: Building and Energy based on the 2009 International Residential Code Chapters 1-11

10/23/2011. Plan Examination. Plan ExaminationPurpose. Catch problems in advance of construction.

BUILDING PERMIT PROCEDURE PLEASE READ CAREFULLY AND FILL OUT COMPLETELY TO ASSURE QUICK AND ACCURATE SERVICE

Chapter ONE- AND TWO-FAMILY DWELLINGS*

Colorado Chapter of the International Conference of Building Officials. Building Guide. The Colorado Chapter of the International

City Planning & Development - Development Services (CPD-DS) 414 E. 12th Street 5 th Floor Kansas City, Missouri Telephone (816)

The following are details of the code requirements of the 2015 International Residential Code for single-story decks.

WFCM 130 MPH GUIDE EXPOSURE B WOOD FRAME CONSTRUCTION MANUAL GUIDE TO WOOD CONSTRUCTION IN HIGH WIND AREAS FOR ONE- AND TWO-FAMILY DWELLINGS

Carroll County Bureau of Permits and Inspection Residential Code Compliance Guidelines

INTERIOR ENVIRONMENT

Inspection Checklist Residential Building Final July 2016

Date Rater Verified. Rater Verified. Slab / Pre-Drywall / Thermal Inspection

DETAIL DRAWINGS. RASTRA is a stay-in-place insulated concrete. form that is structurally strong, energy-efficient,

2014 Florida Residential Code Advanced 5th Edition: Overview Internet

Residential Plan Checklist

PRESENTATION OUTLINE MUBEC & IRC APPLICABILITY & ADMIN. 6/17/2015 RESIDENTIAL STRUCTURAL SYSTEMS. Carmen B. Bombeke, P.E.

Part III Building Planning and Construction

See the IRC for additional information. See CPD-DS Information Bulletin 100 for Requirements for 1 & 2 Family Dwelling plan submittals.

TYPICAL BEARING WALL FRAMING

CITY OF CALABASAS RESIDENTIAL PLAN REQUIREMENTS 1 OF 5 8/2017 PLAN INFORMATION

EMERGENCY MANAGEMENT PREPAREDNESS AND ASSISTANCE TRUST FUND ARC 4496 Evaluation Questionnaire

RESIDENTIAL BUILDING CODE HANDOUT REFERENCES: 2015 Michigan Residential Code

WINDOW AND DOOR REPLACEMENT SAMPLE PLAN

BUILDING CODES Presented by CORUM ENGINEERING

2014 Commercial Plan Submittal Checklist

Part III Building Planning and Construction

FIGURE R502.2 FLOOR CONSTRUCTION

CARROLL COUNTY BUREAU OF PERMITS AND INSPECTIONS RESIDENTIAL CODE COMPLIANCE GUIDELINES FOR DECKS

Advanced Ventilation for Residential applications FBC Res 2010.

A 16' x 28' Cottage with two lofts and a bedroom addition. Plans can be modified for simple or expanded layouts.

Residential Building Permit Application

This tip sheet may be used as a guide for single-family residential uncovered deck permits.

LINCOLN COUNTY REQUIRED INSPECTIONS (Last updated August 23, 2017)

GARAGES/ONE-STORY City of Grand Rapids Building Safety Division

CITY OF GLENDALE RESIDENTIAL PLAN SUBMITTAL CHECKLIST REQUIREMENTS FOR CUSTOM HOMES

CITY OF COEUR D'ALENE Residential Permit Application

Single Family Detached home submittal Workbook

Structural System. Design Criteria Fire Resistance Concrete designed for 2 HR rating (worst case) Geotechnical Report Allowable Bearing Capacity

City of Hughson Building Safety Division 7018 Pine Street Hughson, CA (209)

Residential Building Inspections

Building Design Data

Prescriptive Design for Pole Barns Using the Larimer County Prescriptive Handout

Residential Plan Checklist

Work Write Up / Specification of Repairs HUD DIVISION 1. MASONRY HUD DIVISION 2. SIDING. Toll Free

Basic Information for Obtaining Permits, Submitting Plans, Scheduling Inspections, etc.

The following preliminary issues may need to be addressed prior to an application for a building permit.

4. Number of drawings required: ( ) Locations of nearest streets

City of Bemidji Building Office City Hall 317 4th Street NW Bemidji, Minnesota Phone Fax emi mn s

Custom 24 x 26 Garage Plan Roy Hartmann Plan #g218 By SDS-CAD Specialized Design Systems CLIENT

The permit holder is ultimately responsible for compliance with all aspects of the building code.

2018 APPENDIX B BUILDING CODE SUMMARY FOR ALL COMMERCIAL PROJECTS (EXCEPT 1 AND 2-FAMILY DWELLINGS AND TOWNHOUSES)

HCM UNIVERSITY OF ALASKA FAIRBANKS Building Challenges in Alaska UNIVERSITY OF ALASKA FAIRBANKS

Fairfax County, Virginia

Formulating a Korea Industrial Standard for light-frame wood construction

FEMA P-593 STEP-BY STEP PRESCRIPTIVE RETROFIT FOR CRIPPLE WALL BRACING & ANCHORAGE TO FOUNDATION

Transcription:

BROCHURE # 108 CONSTRUCTION PLAN COMPONENTS Please note: This construction plan component list is to be used as a guide to assist you with your project. There may be elements unique to your project not shown on this plan that will be required on your submittal construction plans. Cover page- At a minimum, the cover page should be provided that includes: a. Table of contents- Identify page numbers included in building plan package and label what items are included on each page b. Name and contact information for the designer c. Site address or other identification for the location of the proposed structure d. Code references and design criteria used, i.e., snow load, roof live and dead loads, floor live and dead loads, wind speed, seismic zone, specific exposure. Ground Snow Load Wind 25 lbs. 110 mph Ult. Topo Effects Special Wind Region Wind- Borne Debris Seismic Design Category Weathering Frost Line Depth No No No D2 Moderate 12 Slight to Moderate Termite Decay Winter Design Temp Moderate to Severe Ice Shield Underlay Req d Flood Hazard 26 0 F No (a) 1980, (b) 1980) Air Freezin g Index Mean Annual Temp 148 51.4 0 F Other items may be included on the cover page that pertain to the project Foundation- **Plans shall be drawn to a standard scale, i.e. ¼ = 1 or 1/8 = 1. a. Scaled layout of the foundation, including exterior footing/ stem walls and interior footing/ stem walls, piers or strip footings. b. Details or reference to a details page showing the proposed width of the footing, height and thickness of the stem wall, reinforcement placement and spacing, pressure treated sill plate and size and spacing of anchor bolts. c. Location and type of hold-down devices, where applicable d. Point loads from framing above e. When constructing a masonry fireplace, foundation plan shall also include specific footing information for the fireplace. f. Crawl space ventilation calculations that specify how much ventilation is required and how it will be provided g. Location of crawl space access, if providing it through the foundation stem wall. h. Location of vents (number of vents determined by the vent calculations) i. For concrete walls enclosing habitable space, i.e. below grade basement, details shall include how damp-proofing will be accomplished and how drainage is being installed. Email: help@kitsap1.com Page 1 of 5

Floor framing- a. Location and size of floor beams b. Size and location of posts, post connections at beam and piers/ footings for beam support or detail of pony wall being constructed c. Type of material (TJI s/ doug fir/ hem fir) size and spacing of proposed floor joists d. If it is not the intent to install the floor joists on top of the foundation stem wall, provide information and details to show how the floor joist will be attached at the foundation walls. e. Indicate any cantilevered floor joists f. Show the location of the crawl space access, if providing through the floor framing g. Indicate double joists or other appropriate support for bearing walls above h. Blocking shall be provided at all intermediate supports and under braced wall panels i. Label location and size of all headers and beams. If manufactured type beams are used, i.e. Glulam, LVL, PSL, etc., calculations that show span information shall accompany construction plans. Other beams with large spans may also be subject to providing calculations. Decks- If a deck is being proposed off of an exterior door, details shall be provided for the following: a. If being supported off the house, indicate the ledger size and how it will be attached. For decks over 30 in height, lateral hold-down devices shall be provided in a minimum of two locations for each section of deck. b. Location, size, and spacing of deck joists. c. Location and size of supporting beams. d. Size of posts and connection to beam and footing e. Size of footings (pre-cast pier blocks are not permitted) f. Construction of stair details, to include handrail height, tread rise/ run g. Type, height and attachment of guardrail (required for all decks over 30 in height) Floor Plan- a. Show outline of house at exterior walls and indicate location of windows, doors. b. Indicate decks, patios, porches or landings being constructed outside exterior doors. c. Provide location of all interior walls and doors d. Label the use of each space. e. Label location of all appliances. This is to include the location of kitchen range, dishwasher, water heaters, fireplaces, furnaces, duct-less systems, heat pumps, washer, dryer, etc. For appliances that can be electric or gas, indicate fuel type. f. Show location of fixtures (sinks, water closets, showers, etc.) g. Label smoke and carbon monoxide alarms h. Label windows complying with the rescue opening (aka egress window) requirements; in every sleeping room i. Location of source specific exhaust fans and proposed CFM (shower, water closets and utility rooms require a minimum of 50 cfm and kitchen hood fans require a minimum of 100 cfm). j. If utilizing a whole house exhaust to meet the ventilation requirements, label the location and size of the whole house exhaust fan. k. Energy code compliance options (see worksheet included in the building permit application for description of options). Options selected shall be clearly identified on the plans. If utilizing an appliance, i.e. high efficiency water heater or furnace, minimum required efficiencies shall be included on the label. Email: help@kitsap1.com Page 2 of 5

Elevations- l. Label windows requiring safety glazing. a. Scaled elevations of all four sides. b. Window, door and skylight locations. c. Roof overhangs. d. Roof slopes. e. Roof & wall coverings. f. Fireplace and other appliance vent terminations. g. Accurate finished grade showing the slope extending 10 feet away from the structure. Wall construction- a. Sectional drawing or similar detail shall be provided to show stud size and spacing. If utilizing a full wall (foundation to roof) sectional drawing, this same detail can show foundation sizing and reinforcement, sill, anchor bolt spacing, stud size and spacing, wall insulation, interior, exterior finishes, roof attachment, attic insulation, etc. b. Structures provided with engineering shall provide details for shear wall requirements. c. Prescriptive designed structures shall include braced wall method chosen and construction details, calculations to show how much bracing is required (per the tables included in section 602.10 of the International Residential Code) and how much is being provided for interior and exterior wall lines. d. If fire walls are required for your project, approved fire wall assembly details shall be provided. Roof construction a. If using pre-manufactured trusses, the proposed roof layout shall be provided; this shall include location of girder trusses, etc. b. For areas requiring over-framing, rafter size and spacing, ridge board and roof attachment shall be provided. c. If stick framing roof; provide type of wood being used, size and spacing of roof rafters, size and spacing of ceiling joist, size and spacing of collar ties, size of ridge board or ridge beam (whichever is applicable) d. Indicate size and location of attic access e. Indicate how attic ventilation will be provided and include ventilation calculations used. If roof overhang extends into a 5 setback (to property line), bird block vents, soffit vents or gable vents are not allowed. If this is applicable, alternative ventilation needs to be provided. f. If mechanical equipment is being installed in the attic, required platforms shall be shown on the plans. If manufactured trusses are used, engineering shall include the installation of the equipment. If stick building a roof system with mechanical equipment, design shall indicate that the additional loads are accounted for. g. Show interior and exterior roof finishes (where applicable) h. Show attic insulation Architectural Construction drawings If a licensed Architect is obtained to develop construction plans, the Architect is required to provide his/her wetstamp and signature on the plans. Plans will not be accepted for permit review if the wet-stamp and signature is not provided. Email: help@kitsap1.com Page 3 of 5

When plans are revised or modified to accommodate a design change, the original Architect is responsible for providing new plans that reflect the revisions/ modifications. New plans shall bear the wet-stamp and signature. Engineered Plans If your project exceeds the parameters for prescriptive design, engineered plans and calculations shall be provided with the construction plans. Plans that include engineering shall be wet-stamped and signed by the designing engineer. Plans will not be accepted for permit review if the wet-stamp and signature is not provided. When plans are revised or modified to accommodate a design change, the original Engineer is responsible for providing new plans that reflect the revisions/ modifications. New plans and calculations shall bear the wetstamp and sign. Construction Plan Submittal Definitions: 1. Foundation: Foundation walls are usually designed and constructed in accordance with accepted engineering practices to carry vertical loads from the structure above, resist wind and any lateral forces transmitted to the foundations and sustain earth pressures exerted against the walls, including any forces that may be imposed by frost action. a. Footing: The bottommost part of a foundation wall, with a course of concrete wider than the base of the wall, designed to support the foundation and prevent settling. Properly designed and constructed footings provide the necessary counter balance forces that enable a house or a building to withstand the forces of nature. b. Stem Walls: Structures used to connect the foundation of a building to its walls. c. Pier: A collection of individual posts dug into the ground, sometimes called a post foundation. Only permitted to support structures of light frame construction not more than two stories in height. d. Strip Footing: Another name for continuous footing, a continuous strip of concrete on either side of a foundation wall that serves to spread the weight of the loading bearing wall across an area of soil. e. Sill Plate: A horizontal structure located at the bottom of the studs used to hold a wall together, provides a surface for attaching the wall to the supporting structure. f. Damp-Proofing: Section 1805 of the IBC, generally refers to the application of one or more coatings of a compound or other materials that are impervious to water, which are used to prevent the passage of water vapor through walls or other building components, and which restrict the flow of water under slight hydrostatic pressure. 2. Floor Framing a. Pony Wall: A wall that only extends partway from floor to ceiling. b. Floor Joists: Length of timber or steel supporting part of the structure of a building, typically arranged in parallel series to support the floor. c. Cantilevered Floor Joists: A joist that projects over a beam. d. Bearing Walls: A wall that bears the weight of the house above. 3. Decks a. Ledger Size: Horizontal beam attached to an existing wall and used to tie in construction elements such as porch roofs and decks. Installed as part of the deck frame construction. b. Deck Joists: Length of horizontal timber used to support the deck floor. 4. Floor Plan a. CFM (Cubic Feet Per Minute): A measurement of the velocity at which air flows into or out of a space. Email: help@kitsap1.com Page 4 of 5

b. Safety Glazing: Reduces the possibility of injury caused by broken glass. The most common type of safety glazing in residential applications is tempered glass. 5. Wall Construction a. Shear Wall: A wall designed of braced panels to resist lateral forces, generally wind or seismic loads, parallel to the plane of a wall. 6. Roof Construction a. Pre-Manufactured Trusses: The structural framework which supports the roof. b. Girder Trusses: Long straight trusses utilized for large buildings primarily used to support other structural elements in the frame, such as traditional trusses, rafters, or purlins. c. Over Framing: When a roof section is framed on top of another roof section, such as when constructing an L shaped roof. d. Stick Framing Roof: Utilized to construct houses with cathedral ceilings, attic rooms, or attic storage areas by creating a triangle between the rafters and ceiling joists. Email: help@kitsap1.com Page 5 of 5