POWERING. AN ALASKA VILLAGE Making the Shift from Fuel Oil to Clean Electricity

Similar documents
Commercial HVAC. Emerging Technologies

Energy Modeling of Dedicated Outdoor Air Systems for a Small Commercial Pilot Project

Air Source Heat Pumps in the Commercial Market. Thursday, February 5, :00-10:30 a.m.

Bullitt Center s Energy Performance

Sapporo Net-Zero Energy Home Hokkaido, Japan. Description. Setting. Super E Canadian Member. Super E Japanese Member. Super E Case Study

The Creative and Performing Arts High School (CAPA) Pittsburgh, PA 9/30/2002 Andrew Tech Mechanical Option Prof. S. A. Mumma

Implementing Low-Cost Energy Savings Projects & Conducting Energy Audits

EADQUARTERS. Thesis Revised Proposal. Stephanie Kunkel Mechanical Option

ENERGY EFFICIENT RETROFIT OF A HIGH-RISE MULTIFAMILY BUILDING

Building Energy Analysis for a Multi-Family Residential Building (Multi V III VRF Heat-Pump System)

ENGINEERING UPDATE WHITE PAPER: BUILDING PERFORMANCE METRICS. price-hvac.com. May 2013 Vol. 10

White Paper ENVELOPE-FIRST APPROACH TO NET-ZERO ENERGY BUILDINGS

Rhode Island Commercial Codes FAQs

Florida HERO Program Residential Eligible Product List All Products

California HERO Program Residential Eligible Product List All Products

UC Berkeley HVAC Systems

MEP's Letter of Assurance

FACILITY DESIGN PLAN FOR HARDING HALL RENOVATION AND ADDITION SOUTH DAKOTA STATE UNIVERSITY DATE: March 29, 2017

LEED Commissioning and Actual Energy Use. John Kokko, P.Eng. LEED A.P. Vice President Enermodal Engineering

Energy Reduction Strategy Through 2020

Testing different approaches to energy reduction in five 1½-storey post-war houses. n Roof constructed of 2 x 6 roof rafters and 1 x 8 roof

Energy Efficiency Programs

Energy Savers: Air-Source Heat Pumps

Energy demand analysis for small and medium scale heat users in Rotorua aiming at converting existing heating systems to bioenergy.

Ductless Heat Pump Program Guidelines

Performance Testing of Cold Climate Air Source Heat Pumps

HERO Program Residential Eligible Product List California Residential Eligible Products... 2

Presentation Overview: NC Energy Code RESNET Standards HERS Index HERS Verification Process

Energy modeling in IDA ICE according to ASHRAE , app. G

Sea Water Heat Pump Project

IECC 2015 with Hawaii Amendments COMMERCIAL DESIGN CHECKLIST

Retrofit of an historical building toward NZEB

Underf loor For Schools

Chilled Beams. The new system of choice?

Asset Energy Calculator Guidance

Comprehensive Energy Audit For Sleetmute Community Center

CHAPTER 3. BUILDING THERMAL LOAD ESTIMATION

Compliance to the IgCC. September 29, 2011

South Carolina Society for Hospital Engineers

Save with Business Programs and Services

The Sustainable Development Fund in 2011

Modeling the Brillhart House

Environmental Stewardship Conference October 05, 2013 Energy Water and Sustainability (EWaS) Program

Ground-Coupled Heat Pump And Energy Storage

45% 39% 17% 92% 100% All paints and adhesives are low VOC

Varennes Net-Zero Library City of Varennes

Chapel House- Design Process- Envelope and Energy savings

Planning for Biomed Facility Puts Energy Efficiency Under Microscope

Program Guide. NB Power Commercial Buildings Retrofit Program. Version 5.5 August 2016

Changes to the Minnesota Commercial Energy Code. Presented by: Andy Thielen, PE

MEP's Letter of Assurance

Zero Carbon Building Energy Modelling Guidelines. October 31, 2017

ENERGY AUDIT. 123 Main Street Mississauga, Ontario. January 1, Report To: Mr. John Smith Smith Printing Company.

COMMERCIAL LOAD ESTIMATING. Load Estimating Level 3: Block and Zone Loads. Technical Development Program

SUSTAINABILITY An Energy & Emissions Case Study

Energy Savings at Military Installations: A Case Study

Presenters: Dominick Balletta Managing Director Jacob Burns Film Center

THERMAL MASS IMPACT ON ENERGY PERFORMANCE OF A LOW, MEDIUM, AND HEAVY MASS BUILDING IN BELGRADE

A Homeowner s Guide to Energy Efficiency

ARPAN JOHARI. Architect. 13/08/10 AW Design. Ahmedabad

Home Energy Assessment Rebate Guide

Building Energy Code:

LIBRARY ENERGY WALK- THROUGH. Andy Robinson, Training and Education, SEDAC

THERMAL MASS IMPACT ON ENERGY PERFORMANCE OF A LOW, MEDIUM AND HEAVY MASS BUILDING IN BELGRADE

AVOIDING 2015 MINNESOTA ENERGY CODE VIOLATIONS

Carbon Neutral 60% 70% 80% 90% Today

MEP Engineer's Letter of Assurance

NEW HOMES PROGRAM 2017 PROGRAM GUIDE

Energy Savers PROGRAM BACKGROUND. Process

Demonstration of modeling of radiant cooling system in design builder. Prashant Bhanware & Bharath Reddy

Pearl River Tower. Guangzhou, China. AEI Professional Project Awards January 2014 PHOTO CREDIT: TIM GRIFFITH

Evaluation of Energy Savings of the New Chinese Commercial Building Energy Standard

COOLIDGE SENIOR HIGH SCHOOL

Assessment of the energy demand in energy-saving office buildings from the viewpoint of variations of internal heat gains

LEED Commissioning and Actual Energy Use

RESEARCH HIGHLIGHT. Design and Construction of the Northern Sustainable House Arviat, Nunavut

CHAPTER 1: OVERVIEW OF ENERGY EFFICIENT CONSTRUCTION

Less energy, more savings and comfort year-round

RESEARCH HIGHLIGHT. Documentation of Super-Insulated Housing in Yukon

Hotels: Water and Energy

NEWMOA June 30, Fran Boucher LEED AP, Certified Energy Manager Senior Energy Engineer

Theory versus practice of energy and comfort in 4 low energy houses in Belgium

Matt Gudorf UCI Energy Manager

Least Cost Path to Achieving 50% Reduction in Residential Energy Use (in Heating Climates)

Italcementi Center for Research and Innovation

Example LEED-NC v2.1 Energy & Atmosphere Credit 1 Submittal

NEW FOUR STORY MIXED USE RESTAURANT, RETAIL, LODGING, AND OFFICE BUILDING OWNER S PROJECT REQUIREMENTS

IECC Commercial Significant Changes Summary Tier I

Green Building. Metrics. May 7, Mark Frankel

Optimisation of an HVAC system for energy saving and thermal comfort in a university classroom

SUPPORTING CARBON NEUTRALITY IN URBAN ENVIRONMENTS USING POSITIVE ENERGY BUILDINGS

Energy Modeling Applications for Existing Buildings

Results and Recommendations from Energy Audit of Shageluk. For VEEP Grants Village of Shageluk, Alaska

Senior Design Project for UNO. Design of the International Studies Building: An Environmental Analysis

LEED BD+C Integrative Process. Lori A. Brown, LEED AP BD+C Power Jam Study! Lorisweb.com 1

Establishing a Baseline, Energy Audits and Energy Star s Portfolio Manager

NEW FOUR STORY MEDICAL CENTER OWNER S PROJECT REQUIREMENTS

Complying with the Minimum Energy Efficiency Standards (MEES)

Kalispell School District Energy Savings Performance Project Review

Passive House retrofit study for Carnegie Mellon 1950's dormitory in Pittsburgh

Transcription:

POWERING AN ALASKA VILLAGE Making the Shift from Fuel Oil to Clean Electricity BY JONATHAN HELLER, P.E., MEMBER ASHRAE A SMALL ISLAND VILLAGE in Alaska wanted to reduce its reliance on expensive imported fuel oil, but simply switching to all oil use electricity would tax the electrical grid. The energy-efficiency approach taken at three major renovations in Sitka, Alaska, completely eliminated the use of fuel oil and demonstrates how current building stock can continue to move toward a carbon-neutral, energy-efficient future. 20 This article was published in High Performing Buildings, Summer 2018. Copyright 2018 ASHRAE. Posted at www.hpbmagazine.org. This article may not be copied and/or distributed electronically or in paper form without permission of ASHRAE. For more information about High Performing Buildings, visit www.hpbmagazine.org.

The exterior of the Sitka Forest Service Offices highlights local stone and wood. The interior is a modern office with high-efficiency lighting and controls. Sitka is located in Southeast Alaska with no road access to the mainland. Towns in this part of the state must carefully manage their energy supplies. ALASKA CANADA SITKA, ALASKA istock.com/jprescott The city of Sitka planned to renovate two high profile public buildings: the library and convention center. Both were uncomfortable, declining and expensive to operate, and both relied on oil boilers. The city wanted to improve and expand the buildings while using the clean electric power already owned by the city rather than send municipal money out of the community to pay for imported oil (See Sitka's Energy Challenges, Page 22). At about the same time, the U.S. Forest Service wanted to convert an older facility into new offices in Sitka. They also wanted to eliminate their use of fuel oil and to convert to carbon-neutral biomass to align their energy use with their core mission. The three retrofits discussed in this article focus on key design features that must accompany renovations of this sort: reduce the load, decouple the ventilation using heat recovery ventilators, right-size zonal heating and cooling equipment, and use highefficiency heat pumps or biomass (See Five Key Design Concepts for the Sitka Renovations on Page 24). Summer 2018 HIGH PERFORMING BUILDINGS 21

Sitka s Energy Challenges Sitka, Alaska, population roughly 9,000, has historically relied on oil for heating, like much of the state. In recent years oil burned in Sitka has been mined in Alaska, shipped to Washington for refining, and barged back up to Sitka. Sitka s electricity comes from a municipally owned hydroelectric dam and backup diesel generators. Several years ago, the city found that they were beginning to run out of electrical capacity. They were using their backup diesel generators frequently, and municipal electric utility was beginning to discourage growth. Fish processors wanted to expand refrigerated processing facilities, and the utility did not have adequate capacity to fully serve them. With oil prices rising, people began shifting from oil to electric heat, which further taxed the system. Furthermore, air quality was suffering as more people began relying on wood stoves. In reaction to the energy and air quality challenges and with an eye to making space for future growth, the city spent $145 million to raise the level of the Blue Lake Dam to expand their hydropower resources. Sitka Public Library From Oil Boiler to Heat Pump System The Sitka Public Library underwent a 4,800 ft 2 expansion in 2016, increasing the total heated floor area by 63%. Early on in design, the team set an ambitious energy target for the project: completely eliminate dependence on oil and maintain the same electrical use. Several energy saving measures were selected to accomplish this goal, with a focus on reducing the heating load while managing the existing electric load. After the first year of full occupancy the energy use and savings were evaluated. Energy bills were collected from before construction (2011-2013) and after construction (2016 to 2017). Annualized results for overall energy use is shown in Figure 1. Table 2 SITKA PUBLIC LIBRARY ENERGY USE Area (ft 2 ) Main takeaways include: Oil, 60% of the preliminary energy use, has been eliminated. Despite the team s goal to maintain the same electrical use, it increased by 32%, because of adding space heat to the electric load and increasing the heated floor area by 63%. Utility costs nearly cut in half, with money staying in the community rather than paying for imported fuel. Carbon emissions eliminated from a previous 72,377 lb/yr of CO 2. Annual energy use normalized by total square footage (EUI) cut by factor of three, from 99 to 32 kbtu/ft 2 yr. This puts it at one-third the national average for libraries. Figure 2 illustrates the building s energy use at varying outdoor temperatures. This type of analysis is useful when examining the heating requirements of a building and Table 1 SITKA PUBLIC LIBRARY ENERGY-EFFICIENCY MEASURES Measure Envelope Space Heating Ventilation Lighting Water Heating Water Fixtures As-Designed Super Insulation: R-30 walls, R-50 roof, R-20 slab, triple-glazed windows Variable refrigerant flow (VRF) heat pumps with radiant floor distribution in large open space and wall cassettes in smaller rooms Dedicated outdoor air system (DOAS) with 80+% sensible energy recovery from the exhausted indoor air 100% LED fixtures with dimming Heat pump water heater for domestic hot water production Low-flow plumbing fixtures Oil Use (Gallon/yr) Electrical Use (kwh/yr) Actual EUI Pre-Retrofit 7,567 3,234 87,689 99.1 Post-Retrofit 12,366 0 115,909 32.0 22

Added envelope insulation at the Sitka Public Library greatly reduces the library's heating energy requirement. Dan Evans analyzing how buildings react to colder (and warmer) temperatures. In Sitka s heating-dominated climate, all efforts must be made to reduce the heating signature if significant energy reductions are to be achieved. Figure 1 SITKA PUBLIC LIBRARY BILLED ENERGY USE 800,000 700,000 600,000 500,000 450,791 Annualized EUI (kbtu/sq ft/year) Figure 2 SITKA PUBLIC LIBRARY ENERGY USE BY OUTDOOR TEMPERATURE 120 110 100 90 80 70 60 50 40 30 [Pre-] Steep slope shows drastic increase in heating energy as temperature drops [Pre-] Electric baseline use unaffected by outdoor temp (lights, plugs, etc.) kbtu/yr 400,000 300,000 200,000 100,000 299,196 395,482 20 10 0 [Post-] Heating signature greatly reduced (means less energy used for space heat) [Post-] Reduced baseline due to low lighting power and better controls 30 35 40 45 50 55 60 Billing Interval Average Outdoor Temp ( F) 0 Pre-Retrofit Post-Retrofit Oil Electricity Consumption Type Electric Post-Retrofit Oil Pre-Retrofit Electric Pre-Retrofit Electric Post-Retrofit Baseline Summer 2018 HIGH PERFORMING BUILDINGS 23

Joe McCabe Before the retrofit, all heating was done with an oil boiler at 80% efficiency (blue line). Electricity covered the remaining end-uses (green line). In looking at Figure 2, the heating signature is quite pronounced (blue line steeply increases as the average outdoor temperature drops). This is related to a poor envelope and inefficient heating system. Post-retrofit, added envelope insulation and heat recovery ventilation greatly reduces the heating energy requirement, while the high-efficiency variable refrigerant flow (VRF) heat pump system provides hydronic-radiant and airside space heat and cooling as needed (sloped red line). Efficient fans, which are turned off when there is no call for heat/cool, and LED lights further reduce the daily electrical use. ABOVE The renovation of Sitka s public library added 60% to the floor area to better serve the community. LEFT The sitting area in the library looks out over the harbor. The building seen through the window is neighboring Harrigan Centennial Hall. Five Key Design Concepts for the Sitka Renovations Heating Load Reduction. Through investing in the building envelope and heat recovery ventilation, the heating load was reduced by approximately 50% for these three buildings. This was done with high performance glazing, extra insulation in the walls and roof and heat recovery ventilation for tempering all the ventilation air. This shifts money from the mechanical system to the building envelope since the mechanical system can be significantly smaller. These envelope investments last 30 to 50 years or more and can be most costeffectively implemented during major renovations. Dedicated Outdoor Air System (DOAS). The heat recovery ventilators were configured as DOAS with the ventilation ducted separately from the heating and cooling systems. This design approach significantly reduces duct sizing and fan energy since only the ventilation fans need to run for most hours of the day. Typical designs coupling ventilation with heating and cooling equipment must rely on the much larger HVAC fans to run continuously to deliver the ventilation air. Zonal Heating Systems. With ventilation separated from the heating and cooling delivery, systems were designed to allow for maximum zoning control to turn off equipment in areas where and when it is not needed instead of large central fan systems, which must run during all occupied hours. Right-Sized Equipment. Careful sizing calculations instead of rules of thumb allow for smaller systems with cost and energy savings and better comfort and acoustics. Decarbonization. Elimination of fossil fuels through use of biomass or heat pump technology for space heating and domestic water heating dramatically reduces carbon emissions without adding electric resistance, which could over-tax the electrical grid. 24

U.S. Forest Service Office From Oil Boiler to Wood Pellet Boiler The U.S. Forest Service project converted an old run-down facility on the edge of town that used an oil boiler and radiators for heating into a beautiful new super-efficient office facility. The envelope was upgraded with high levels of envelope insulation and triple-paned windows, and ventilation is accomplished with a The wood pellet boiler, manufactured in Europe, uses untreated wood pellets made from compressed waste sawdust. The automatic feed mechanism delivers only a few pellets at a time into the burn chamber. high-efficiency heat recovery ventilator to dramatically reduce heating energy demand to about 50% of a typical code-compliant design. Then, heating was provided with radiant floors supplied from a wood pellet boiler. There was a strong desire among some within the Forest Service to use forest biomass for heating, but there has been mixed experience in Alaska with biomass boilers as the market for these products is still relatively immature. The distribution infrastructure for pellets is weak and maintenance know-how is lacking. To alleviate these concerns, the pellet boiler was backed up with an airto-water heat pump system so in the event of a fuel shortage or boiler failure the building can be heated with highly efficient use of hydropower. To date the pellet boiler has functioned as expected and they have not needed to rely on the backup heat pumps. Pellets for the pellet boiler are manually loaded into the storage hopper (shown here) and transported by an auger mechanism into the pellet boiler s burn chamber. Sitka has mild maritime weather, with long cool winters (about 7,400 heating degree-days) and average daily highs in the low 60s in the summer (zero cooling degree-days). Therefore, ceiling fans and operable windows are provided for comfort cooling. Table 3 U.S. FOREST SERVICE OFFICE ENERGY-EFFICIENCY MEASURES Measure Envelope Space Heating Ventilation Lighting Water Heating Water Fixtures As-Designed Super insulation: R-15+2 in. rigid insulation walls, R-50 roof, R-20 slab, tripleglazed windows Hydronic distribution from wood pellet boiler with air-to-water heat pump backup Dedicated outdoor air system with 80% sensible energy recovery from the exhausted indoor air 100% LED fixtures with dimming Heat pump water heater for domestic hot water production Low-flow plumbing fixtures Table 4 U.S. FOREST SERVICE ENERGY USE U.S. Forest Service Office Area (ft 2 ) Pellet Use (tons/yr) EUI from Pellets Electrical Use (kwh/yr) EUI from Electricity Actual Total EUI Post-Retrofit 11,115 8 11.5 87,760 26.9 38.5 Note: The Forest Service building was partially empty and a lot of it was used as a warehouse prior to the retrofit, so pre-retrofit numbers are not relevant. 26

Harrigan Centennial Hall From Coupled To Decoupled Ventilation Don Kluting chiller. Since the fan coils provided ventilation air as well as heating and cooling, the large central fans would have to run during all occupied hours to provide ventilation even when no heating or cooling was required. The Harrigan Centennial Hall with its new museum addition is the welcoming point for summer tourists and a gathering place for community events throughout the year. Next door to the Sitka Public Library is Harrigan Centennial Hall. It provides public gathering space and is the first public building to welcome the thousands of cruise ship tourists who visit Sitka every summer. Like the library project, the convention center was worn down and expensive to operate. The city wanted to increase the size of the building to allow for expanded space for a heritage museum as well as increase their offerings to the public. They wanted to accomplish this while eliminating their use of imported oil and cutting their energy use. As with the library project, the design approach was to first focus investment on the building envelope with new windows and insulation. The original building was based on large 4-pipe fan coil air handlers with fixed outdoor air supply provided with hot water from an oil boiler and chilled water from an air-cooled Table 5 HARRIGAN CENTENNIAL HALL ENERGY-EFFICIENCY MEASURES Measure Envelope Space Heating Ventilation Lighting Water Heating Water Fixtures As-Designed R-21+1.5 in. rigid insulation walls, R-38 roof, high performance double-glazed windows Variable refrigerant flow (VRF) heat pump system. Mostly ductless ceiling cassettes with some ducted units for larger spaces. Dedicated outdoor air system with 70% to 80% sensible energy recovery from the exhausted indoor air 100% LED fixtures with dimming Heat pump water heater for domestic hot water production Low-flow plumbing fixtures Table 6 HARRIGAN CENTENNIAL HALL ENERGY USE Area (ft 2 ) Oil Use (Gallon/yr) Electrical Use (kwh/yr) Actual EUI Pre-Retrofit 20,124 7,405 197,920 84.2 Post-Retrofit 32,500 0 384,600 40.4 Summer 2018 HIGH PERFORMING BUILDINGS 27

Lessons Learned At the Sitka Public Library, the original intent was to have a robust and detailed M&V system with submetering of individual electrical loads, with real-time feedback and continuous datalogging of energy used for lighting, fans, heating, cooling, hot water, and miscellaneous plug loads. This would allow detailed energy management and tracking of performance of individual building systems. However, this level of submetering and tracking requires somewhat complex submetering and programming of datalogging functions and a data management plan and city staff interested in managing and analyzing the data flow. The controls contractor and city settled on a simpler submetering plan that only allows for tracking total energy use and submetering of the heat pump system. The lesson learned is more communication with all parties early in the project is always better and local conditions and politics are often difficult to negotiate from outside Alaska. Furthermore, it is important to know when to step back, as the client ultimately must make the decisions regarding final design and contracting issues. The biomass boiler for the U.S. Forest Service building was new to us, the HVAC contractors and the local forest service management and maintenance personnel. There was some trepidation to use a biomass boiler due to a recent injury from a wood boiler explosion in another part of Alaska. Furthermore, a well-established distribution network for the pellets does not exist, so loading the hopper is done a bag at a time by hand from a pickup truck. This resulted in push and pull between local forest service workers and the regional officials regarding selection of the heating system. To overcome the local office s reluctance, we designed the air-to-water backup heat pump system to provide system redundancy so the building can switch back and forth from pellets to highly efficient electricity depending on pellet availability and price. After the first year of operation, the pellet boiler has performed without incident. One primary lesson learned at Harrigan Centennial Hall is that VRF equipment vibrations must be adequately isolated from the building structure to eliminate noise complaints. Originally, the heat pumps were not mounted with the manufacturer s recommended clamping system, and it took months to get correct products and sizes shipped to Sitka. And, the refrigerant piping was rigidly attached to the building s wall, so equipment vibration was being transferred to the wall diaphragm and creating interior noise complaints. Eventually these items were corrected. Harrigan Centennial Hall's heating and cooling is provided with a zonal air-to-air VRF heat pump with ductless ceiling cassettes in most zones. new system decoupled the ventilation from the heating and cooling using high-efficiency heat recovery ventilators with 70% to 80% thermal effectiveness so no additional tempering of the ventilation air is required. These much smaller ventilation fans are all that needs to run for much of the year. The heating and cooling is provided with a zonal airto-air VRF heat pump with ductless ceiling cassettes in most zones. The ductless cassettes have extremely low fan energy requirements and can cycle off when there is no call for heating or cooling. Low velocity high volume (LVHV) ceiling fans aid air distribution. Along with a lighting retrofit this approach led to an EUI reduction of more than a factor of two compared to the original building systems. Fossil fuel use was eliminated, and electrical energy use also dropped even for the enlarged building. Future Work Sitka continues to promote a shift away from fuel oil to clean electricity. The city utility has been providing incentives to shift homes from electric resistance heat to ductless heat pumps. The Alaska Housing Finance Corporation also has a generous rebate program for insulation and transitioning from electric resistance, oil and propane to ductless heat pumps. The city has seen a surge of demand for ductless heat pumps and has seen an improvement in local air quality from using less oil and wood heat. ACKNOWLEDGMENTS The author thanks the City and Borough of Sitka, Alaska, and the architects of the three buildings featured for their assistance: Rice Fergus Miller (U.S. Forest Service); MRV Architects (Sitka Public Library); and McCool Carlson Green (Harrigan Centennial Hall). ABOUT THE AUTHOR Jonathan Heller, P.E., is president at Ecotope, Inc., in Seattle. 28