The Real Truth About R-value Innovative Insulation Solutions
Thermodynamics 101 * Warm air migrates to colder air * Warm air rises - cold air falls * Moisture goes from warm to cold * Moisture goes from more to less * Air goes from a higher pressure to a lower pressure * Gravity acts downward
I.R. Imaging Shows the temperature of a specific spot Blue coloring around studs and between fiberglass joints indicates air leakage Darker studs = energy loss Energy loss through and around framing is called Thermal Bridging
PROBLEMS with Insulation Thermal Bridging Air Leakage Moisture = PROBLEMS Infrared Imaging: Pictures worth a 1,000 words
Air Leakage = Moisture Dark coloring = AIR LEAKAGE & MOISTURE Green horizontal lines & dots = THERMAL BRIDGING Pink, blue, purple = WATER
NRC concludes air infiltration accounts for up to 40% of the energy lost in most buildings
Rim Joists & Electrical Air leakage is the major cause of moisture problems in walls and roofs - National Research Council Canada
Between 50 and 70% of the effective thermal resistance is lost if the system allows vapour transfer from one side of the cavity the other. National Research Council Canada
Frozen Moisture NO Cavity Insulation Batt Insulation & Vapour Barrier Batt Insulation - NO Vapour Barrier
Frozen to steel Batt insulation compressed against eave strut NO insulation value -3.7C. at eave strut INSIDE the building IMAGINE the energy bill for this building!
Joseph Lstiburek, Ph.D., P.Eng., ASHRAE Fellow, is a principal of Building Science Corporation. He is internationally recognized as a foremost authority on energy efficient construction techniques.
DRY-ROT
Batt Insulation & Basements Effective R-value REDUCED by 25% to 65% HIGH ENERGY COSTS & INFERIOR COMFORT ABSORBS MOISTURE - acts like a blotter PROMOTES & SUPPORTS MOLD GROWTH
MOLD IN BASEMENTS NASTY STUFF Flooding / moisture & batt insulation promote & support mold growth Sinus and digestive track infections are common Triggers Asthma Can cause DEATH
CMHC STUDY Presence of toxic molds in basement walls is common 27 tested, 16 had mold Toxigenic mold found in 15 of these houses Potential impacts beyond the scope of the study Requires attention by health and building science
National Energy Code for Buildings (NECB 2011) Mandates a 25% INCREASE in energy efficiency in 2014 Effective R-value / U- value REPLACES labelled R-value 50% INCREASE in building energy efficiency by 2016
What is Effective R-Value? Is the ability of REAL WALL assemblies containing wood, steel or concrete framing, drywall, OSB, metal sheathing(s)and insulation to resist the flow of heat in simulated REAL WORLD environments.
Oakridge National Laboratory / US Department of Energy states: R-19 batts have an R-value of 13.7 when installed as commonly found in actual walls.
ASHRAE (American Society of Heating, Refrigerating and Air-conditioning Engineers) claims the Effective R-Value of a Steel Frame Wall with R-19 Fiberglass Insulation is.only R-7.1
National Research Council "In recent years, the focus of building code and regulatory officials, professionals and researchers has shifted towards the performance of the entire wall system. Therefore, it is not sufficient to characterize the wall by its R-value alone, as was the case in the past."
"The use of effective R-values when evaluating the thermal resistance of an assembly is preferable to using the nominal/labelled R-value of the insulation alone. "The BEST method of testing is "Full- Scale thermal testing such as ASTM C1363 carried out at a certified laboratory
ADVANTAGES CONTINUOUS INSULATION SAVES energy $$$ s o Reduces Thermal Bridging through framing o Reduces air leakage o Increases the comfort of buildings o Reduces the dew point effect o Sustainable protects buildings infrastructure
Too BREATHE or NOT To BREATHE the DOUBLE VAPOUR BARRIER SYNDROME
NRC Study Double Vapour Barrier The study demonstrated that placing a material with low water-vapour permeance on the outside of an exterior wall does not necessarily increase the potential for condensation within the wall structure as long as sufficient thermal resistance is added outboard of the innermost plane
Change is the law of life those who look only to the past or present are certain to miss the future. - John F. Kennedy
Quik-Therm Innovation Insulation Solutions
Cold Climate Tested Full Scale REAL WORLD Testing - ASTM 1363 Includes building materials & insulation Temperature Range: +21C. to -18C. 22 KPH wind Simulates Canadian winters
Eco-friendly Contains up to 15% recycled Expanded Polystyrene (EPS) (Maximum allowed) NO off gassing = STABLE R-value Does not contribute to the green house gas effect Environmentally benign 30
It's Summer and it's HOT outside......which wall would YOU want in YOUR Building?
The tested thermal resistance of the assembly (referring to 1 Quik-Therm MPI in a steel stud concrete wall) actually EXCEEDS the calculated thermal resistance of a concrete wall insulated with R-20 batt insulation in a stud cavity.
33
Concrete Tilt Up??
Spray Foam & It's + 5C. Outside Thermal bridges can seriously interfere with the performance of buildings - National Research Council Canada
Quik-Therm Multi Purpose Insulation (MPI) 36
With Quik-Therm YOU feel SUPERIOR COMFORT at lower room temperatures
Sub-Grade Insulation (SGI) Flexibility, Durability and ADVANCED R-value Performance EASIER FASTER BETTER
FLEXIBLE & DURABLE Installs in about 1/2 the time of foam board insulation & poly
Ready for Concrete 42
Quik-Therm Concrete Insulation System (CIS)
Can YOUR Concrete Insulation DO THIS?
Tongue & Groove Connections
5 in 1 Concrete Insulation System
COMPARE Rim Joists & Electrical
2 Quik-Therm CIS R-20 Fiberglass COMPARE 2 CIS to R-20 fiberglass SAME basement wall side by side CIS wall is up to 6 degrees WARMER
COMPARE Insulation System Labelled R-value Effective R-value Healthy, Comfortable & Energy Efficient 3 Quik-Therm CIS 2 Quik-Therm CIS 5 Insulated Concrete Forms Wood Studs & R-20 Batt Steel Studs & R-20 Batt R-11.4 R-25.5 YES R-7.6 R-17.2 YES R-21 R-21.4 YES R-20 R-14 to R-16 NO R-20 R-5.2 to R-7.1 NO As reported by independent accredited testing laboratories
Connect Structure, Insulation, Air, Vapour and Radiant Barrier. ALL in ONE
Attaches Structurally to ANYTHING
AMAZING Structural Integrity 53
New Construction
Thank You INNOVATIVE INSULATION SOLUTIONS