CITY OF LOS ANGELES CALIFORNIA

Similar documents
CITY OF LOS ANGELES CALIFORNIA

CALIFORNIA ERIC GARCETTI MAYOR

CITY OF LOS ANGELES CALIFORNIA

SECTION STAY-IN-PLACE INSULATED CONCRETE FORMING SYSTEM

REPORT HOLDER: BLUE POINT FASTENING, INC YORBA COURT CHINO, CALIFORNIA EVALUATION SUBJECT:

SECTION PERMANENT FORMS Insulating Concrete Forms Rev

DIVISION: MASONRY SECTION: CONCRETE UNIT MASONRY REPORT HOLDER: 3B CONSTRUCTION SOLUTIONS, INC.

Supplemental Concrete Tilt Up Retrofit Plan Check Correction Sheet (2014 LABC)

STANDARD PLAN BULLETIN SP-2 (Structural)

DIVISION: CONCRETE SECTION: INSULATING CONCRETE FORMING REPORT HOLDER: AMVIC INCORPORATED

Originally Issued: 08/22/2014 Revised 03/10/2017 Valid Through: 08/31/2017

Originally Issued: 04/18/2014 Revised: 05/02/2018 Valid Through: 04/30/2019

Statement of Special Inspections Michigan Building Code 2012 (MBC 2012)

Plan Check No. Checked by: An Appointment Is Required for Verification

Structural Tests and Special Inspections Form. Inspection of Fabricators (1704.2)

Project Address: Name of Person Completing Form:

Originally Issued: 11/24/2010 Revised: 01/20/2017 Valid Through: 11/30/ Design

REPORT HOLDER: HILTI, INC DALLAS PARKWAY, SUITE 1000 PLANO, TEXAS EVALUATION SUBJECT: HILTI LOW-VELOCITY POWER-ACTUATED FASTENERS

RECONSTRUCTION AND REPLACEMENT OF EARTHQUAKE DAMAGED MASONRY CHIMNEYS

Sept 30, 2004 Page 1 PRODUCT DESCRIPTION PRODUCT FEATURES

A Guide for the Interpretation of Structural Design Options for Residential Concrete Structures

DIVISION: CONCRETE SECTION: SPECIALTY PLACED CONCRETE REPORT HOLDER: EMMEDUE S.P.A.

CITY OF LOS ANGELES CALIFORNIA

DIVISION: CONCRETE SECTION: CONCRETE ACCESSORIES REPORT HOLDER: NELSON STUD WELDING, INC WEST RIDGE ROAD ELYRIA, OHIO 44036

Lintel Tables Design Notes and Limitations

DIVISION: SPECIALTIES SECTION: MANUFACTURED FIREPLACES REPORT HOLDER: FIRE ROCK PRODUCTS LLC

PRECAST CONCRETE PRODUCTS

ACCEPTANCE CRITERIA FOR THREADED HIGH-STRENGTH STEEL BARS FOR CONCRETE REINFORCEMENT PREFACE

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: METAL ROOF PANELS SECTION: METAL WALL PANELS REPORT HOLDER:

RETAINING WALL LEVEL BACKFILL

See the IRC for additional information. See CPD-DS Information Bulletin 100 for Requirements for 1 & 2 Family Dwelling plan submittals.

SPECIAL INSPECTION AND OBSERVATION PROGRAM CITY OF CONCORD BUILDING DIVISION. Project Address:

Advantage ICF System Product Information Bulletin

REPORT HOLDER: FASTENING SPECIALISTS, INC. 726 CENTRAL FLORIDA PARKWAY ORLANDO, FLORIDA EVALUATION SUBJECT:

DIVISION: CONCRETE SECTION: REINFORCING STEEL REPORT HOLDER: DEXTRA MANUFACTURING CO., LTD.

1.02 STANDARD REFERENCES: The following standard specifications shall apply to the Work of this Section as indicated:

Trusted SECTION: 04 HILTI, INC. TULSA, Conformity! ICC-ES Evaluation. not specifically. Copyright 2015

REPORT HOLDER: MITEK USA, INC. (FORMERLY USP STRUCTURAL CONNECTORS) SOUTHCROSS DRIVE, SUITE 200 BURNSVILLE, MINNESOTA EVALUATION SUBJECT:

Anchor bolts ASTM F1554, Gr. 36 Wide flange beams ASTM A992, Fy = 50 ksi Misc. structural steel ASTM A36, Fy = 36 ksi

DIVISION: CONCRETE SECTION: CONCRETE ACCESSORIES SECTION: REINFORCING STEEL REPORT HOLDER: PEIKKO GROUP, INC.

DIVISION: CONCRETE SECTION: REINFORCING STEEL REPORT HOLDER: BARSPLICE PRODUCTS INC WEBSTER STREET DAYTON, OHIO

DIVISION: CONCRETE SECTION: CONCRETE ACCESSORIES SECTION: REINFORCING STEEL REPORT HOLDER: PJ S REBAR INC.

Legacy report on the 1997 Uniform Building Code, the 2000 International Building Code and the 2000 International Residential Code.

Joint Evaluation Report

DIVISION: CONCRETE SECTION: CAST IN CONCRETE ANCHORS DIVISION: CONCRETE ANCHORS REPORT HOLDER: DEWALT

Quality Control And Fabrication Manual Metal Stud Crete Metal Stud Crete Metal Stud Crete

October 12, Yours very truly, Gary G. Nichols, P.E., SECB Vice President. GGN/md Enclosure Evaluation Committee

REINFORCING TABLES INSTALLATION MANUAL

DIVISION: MASONRY SECTION: MASONRY ANCHORS REPORT HOLDER: DEWALT 701 EAST JOPPA TOWSON, MARYLAND EVALUATION SUBJECT:

DIVISION: MASONRY SECTION: MASONRY ANCHORS REPORT HOLDER: DEWALT 701 EAST JOPPA ROAD TOWSON, MARYLAND EVALUATION SUBJECT:

ESR-2894 Reissued April 2014 This report is subject to renewal April 1, 2016.

Structural System. Design Criteria Fire Resistance Concrete designed for 2 HR rating (worst case) Geotechnical Report Allowable Bearing Capacity

Proposed Modification to the Florida Building Code

ESR-2269 Reissued November 1, 2008 This report is subject to re-examination in one year.

DIVISION: MASONRY SECTION: MASONRY ANCHORS REPORT HOLDER: DEWALT 701 EAST JOPPA ROAD TOWSON, MARYLAND EVALUATION SUBJECT:

REPORT HOLDER: HILTI, INC DALLAS PARKWAY, SUITE 1000 PLANO, TEXAS EVALUATION SUBJECT:

REPORT HOLDER: HILTI, INC DALLAS PARKWAY, SUITE 1000 PLANO, TEXAS EVALUATION SUBJECT:

Originally Issued: 02/11/2011 Revised: 02/23/2018 Valid Through: 02/28/2019

DIVISION: MASONRY SECTION: MASONRY ANCHORS REPORT HOLDER: DEWALT 701 EAST JOPPA ROAD TOWSON, MARYLAND EVALUATION SUBJECT:

DIVISION: WOOD, PLASTICS AND COMPOSITES SECTION: STRUCTURAL PANELS REPORT HOLDER: ENERCEPT, INC.

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: METAL WALL PANELS REPORT HOLDER: FCP, INC.

REPORT HOLDER: HILTI, INC DALLAS PARKWAY, SUITE 1000 PLANO, TEXAS EVALUATION SUBJECT: HILTI LOW-VELOCITY POWER-ACTUATED FASTENERS

ACCEPTANCE CRITERIA FOR METAL PLASTER BASES (LATH) PREFACE

DIVISION: MASONRY SECTION: MASONRY ANCHORS REPORT HOLDER: DEWALT 701 EAST JOPPA ROAD TOWSON, MARYLAND EVALUATION SUBJECT:

CSU GUIDELINES. April 27, 2018 FOR POST-TENSIONED CONCRETE STRUCTURES.

STRUCTURAL MASONRY SPECIAL INSPECTOR. Study Guide

POST FRAME BUILDING STANDARDS

DIVISION: METALS SECTION: METAL FABRICATIONS REPORT HOLDER: QUALITY WAY PRODUCTS, LLC 407 HADLEY STREET HOLLY, MICHIGAN 48442

Pulaski County, Virginia

DRAFT - MOCA STANDARD for Fiber-Reinforced Magnesium Cement Board

ESR ICC Evaluation Service, Inc. Reissued January 1, 2008 This report is subject to re-examination in one year.

DIVISION: CONCRETE SECTION: CONCRETE ANCHORS SECTION: PRECAST STRUCTURAL CONCRETE SECTION: SITE CAST CONCRETE

REPORT HOLDER: AEROSMITH FASTENING SYSTEMS 5621 DIVIDEND ROAD INDIANAPOLIS, INDIANA EVALUATION SUBJECT: AEROSMITH 5000 SERIES FASTENERS

Originally Issued: 09/16/2010 Revised: 09/15/2017 Valid Through: 09/30/ Design:

DIVISION: CONCRETE SECTION: CAST IN CONCRETE ANCHORS SECTION: CONCRETE ANCHORS REPORT HOLDER: MASON WEST, INC.

INSULATED CONCRETE MASONRY UNITS Section 04220

Details for Exterior Brick Masonry Veneer Supported by Metal Plate Connected Wood Trusses

PRECAST CONCRETE CONNECTIONS - US PRACTICE

DIVISION: CONCRETE SECTION: CONCRETE ACCESSORIES SECTION: REINFORCING STEEL REPORT HOLDER: TENDON SYSTEMS, LLC

Originally Issued: 12/12/2014 Revised: 12/29/2017 Valid Through: 12/29/2018

DIVISION: MASONRY SECTION: MASONRY ANCHORS REPORT HOLDER: POWERS FASTENERS, INC. 701 EAST JOPPA ROAD TOWSON, MARYLAND 21286

RESIDENTIAL CONSTRUCTION New Dwellings and Additions

DIVISION: CONCRETE SECTION: CONCRETE ANCHORS DIVISION: METALS SECTION: POST INSTALLED CONCRETE ANCHORS

SECTION CAST-IN-PLACE CONCRETE

ANSI/APA PRS Standard for Performance-Rated Structural Insulated Panels in Wall Applications

Originally Issued: 05/20/2013 Revised: 07/07/2017 Valid Through: 05/31/ Design

DIVISION: MASONRY SECTION: MASONRY ANCHORS REPORT HOLDER: HILTI, INC DALLAS PARKWAY, SUITE 1000 PLANO, TEXAS 75024

DIVISION: MASONRY SECTION: MASONRY ANCHORS REPORT HOLDER: HILTI, INC DALLAS PARKWAY, SUITE 1000 PLANO, TEXAS 75024

Special Reinforced Concrete Structural Walls

TITEN HD Heavy Duty Screw Anchor for Concrete & Masonry

DIVISION: CONCRETE SECTION: CAST-IN CONCRETE ANCHORS SECTION: CONCRETE ANCHORS REPORT HOLDER: HILTI, INC.

Wall bracing panel requirements

ALLOWABLE STRESS DESIGN OF CONCRETE MASONRY LINTELS. TEK 17-1C Structural (2009) Related TEK: Uniform load. Triangular load. Concentrated loads

Concrete Masonry. Weights and Process. Grades & Types

CHAPTER 21 MASONRY SECTION

2016 Port of San Francisco Building Code

4.1 General. 4.2 Materials

DIVISION: MASONRY SECTION: MASONRY ANCHORS REPORT HOLDER: ITW RED HEAD 700 HIGH GROVE BOULEVARD GLENDALE HEIGHTS, ILLINOIS 60139

City of Republic Community Development Girder and Header Spans for Exterior Walls

REINFORCED CONCRETE WALL BOUNDARY ELEMENT LONGITUDINAL REINFORCING TERMINATION

Transcription:

BOARD OF BUILDING AND SAFETY COMMISSIONERS MARSHA L. BROWN PRESIDENT VAN AMBATIELOS VICE-PRESIDENT VICTOR H. CUEVAS HELENA JUBANY ELENORE A. WILLIAMS CITY OF LOS ANGELES CALIFORNIA ANTONIO R. VILLARAIGOSA MAYOR DEPARTMENT OF BUILDING AND SAFETY 201 NORTH FIGUEROA STREET LOS ANGELES, CA 90012 ANDREW A. ADELMAN, P.E. GENERAL MANAGER RAYMOND CHAN EXECUTIVE OFFICER ARXX Corporation RESEARCH REPORT: 13535 SW 72 nd Ave, Ste 100 (CSI #03135) Portland, OR 97223 Expires: November 1, 2010 Attn: Rita Hansen, Director Issued: November 1, 2008 (971) 222-0006 Ext 110 Code: 2008 LABC GENERAL APPROVAL Revision - DETAILS General: The consists of individual blocks that form a permanent formwork system for reinforced concrete beams, lintels, walls, foundation walls and retaining walls. Walls constructed as described in this report are permitted to be used as loadbearing and non-load bearing walls resisting axial, racking and transverse loads in Type II, III and Type V construction in accordance with 2008 LABC. The APEX Block TM Interlocking System is also classified as 3-hour fire-resistance rated, limited load-bearing wall when constructed in accordance with this report. See Figures 1, 2 and 3 for details of the system. Materials: The consists of APEX blocks, concrete and reinforcement. APEX Blocks: APEX blocks are manufactured from a mixture of recycled expanded polystyrene (EPS) aggregate, Type I or II Portland cement, a proprietary accelerant solution and water. A standard block is 10 inches high, 16 inches high and 48 inches long. Each block is molded with 6 inch vertical and horizontal cores. When stacked, the blocks form vertical and horizontal cavities where concrete and reinforcement are placed. Concrete: Block cores shall be filled at the jobsite with normal-weight concrete having carbonate or siliceous aggregate with a 3/8 inch maximum aggregate size and an 8-inch slump. The concrete shall have 3000 psi minimum compressive strength. Reinforcement: ASTM A 615 Grade 60 deformed steel reinforcing bars shall have minimum yield strength of 60 ksi. Page 1 of 8 LADBS G-5 (Rev.6/08) AN EQUAL EMPLOYMENT OPPORTUNITY - AFFIRMATIVE ACTION EMPLOYER

Design: The design of cast-in-place, reinforced concrete structural members formed by APEX Block TM Interlocking System blocks must conform to Chapters 16 and 19 of the 2008 LABC with the following requirements: 1. Minimum vertical and horizontal reinforcement shall be No. 4 for all Seismic Design Categories (2008 LABC) spaced a maximum of 16 inches on center. The reinforced bar sizes may need to be increased, depending upon demand loads, as a result of the structure being designed under Chapters 16 and 19 of 2008 LABC. 2. Development and splices of reinforcement shall be in accordance with Chapter 12 of ACI 318-05. 3. Calculations shall be based on the assumption that the APEX Block TM Interlocking System Wall behaves as a solid-concrete wall having an equivalent thickness, b eq, equal to 4.5 inches for walls with 6-inch-diameter horizontal and vertical cores. 4. The strength reduction factor, φ, with a value of 0.85 shall be used. 5. A shape reduction factor,ψ, with a value of 0.85 shall be used. 6. For members subject to shear and flexure only, the nominal shear strength provided by the concrete is determined as follows: V c = 2 φ ψ sqrt(f c ) b eq d where: b eq = Width of an equivalent rectangular section equal to 4.5 inches for 6 inch cores d = Distance from extreme compression fiber to centroid of tension reinforcement (inches) f c = Specified compressive strength of concrete (psi) φ = Strength reduction factor equal to 0.85 ψ = Shape-reduction factor equal to 0.85 7. In-plane shear strength of shear walls is determined as follows: F v = φ ψ sqrt(f c )L u b eq where: b eq = Width of an equivalent rectangular section equal to 4.5 inches for 6 inch cores L u = Total length of shear wall panel (inches) f c = Specified compressive strength of concrete (psi) φ = Strength reduction factor equal to 0.85 ψ = Shape-reduction factor equal to 0.85 Page 2 of 8

8. The length of the wall considered the effective length for concentrated vertical loads shall be based on the design of a concrete bond beam at the top of the wall engineered to distribute vertical loads to vertical concrete cores. 9. Wall subject to axial loading or combined flexural and axial loading shall be designed as compression members in accordance with requirements of ACI 318-05. 10. Anchorage to foundations shall comply with requirements of ACI 318-05. 11. The used as a foundation stem wall shall be designed in accordance with Section 1805.5 of 2008 LABC. 12. The used as a retaining wall shall be designed in accordance with this report and accepted engineering principles. The approval is subject to the following conditions: 1. Complete design and calculation shall be prepared by an engineer licensed in the State of California and approved by the structural plan check. 2. The maximum allowable pour rate of the forms shall be 4 feet per hour. 3. Continous inspection by Deputy Inspectors shall be provided for placement of reinforcing steel and concrete. Any exception shall be approved by structural plan check supervisors. 4. The Wall Forms units are limited to use in buildings that are combustible construction. 5. The Wall system shall be supported on concrete footings complying with Chapter 18 of 2008 LABC. Vertical rebar, embedded in the footing, shall extend into panel wall system a minimum of 24 inches, or a length complying with requirements of ACI 318-05, whichever is greater. 6. The blocks may be laid horizontally or vertically provided horizontal and vertical reinforcement is placed in accordance with approved building plans. 7. Horizontal reinforcement is permitted to rest directly on blocks. 8. Concrete must fill all voids of the wall blocks. Concrete can be placed in lifts in compliance with manufacturer s installation instructions. Field verification of a proper pour can be accomplished by pushing a 1/4 inch diameter steel rod through the face shell of the blocks into concrete core and noting upon its withdrawal the presence of wet concrete on the rod. Page 3 of 8

9. Wood ledgers shall be attached to the wall. The face shell of the panel may remain in place. Wood ledgers are attached by cutting 6-inch diameter holes into the face shell of the panel before placement of concrete at the location of a horizontal or vertical core at spacing required by design. A dam shall be used to hold the J-bolt centered in the hole. When concrete is poured into the wall system, the holes provided for the J-bolts form a solid concrete connection from the ledger board to the horizontal bond beam. 10. Wood plates must be anchored to the top of the wall. Anchor bolts used to connect the wood ledgers or the plates to the concrete shall be cast-in-place, with the bolts sized and spaced as required design. 11. wall blocks are permitted to be exposed to the interior where allowed by the code. The flame spread index is 25 or less and smoke developed index is 50 or less. 12. Exterior walls shall be covered with approved wall covering in accordance with requirements of Chapter 14 of 2008 LABC. 13. For below grade applications, wall surfaces shall be damp-proofed and water proofed in accordance with requirements of Section 1807 of 2008 LABC. 14. Wood members in contact with concrete for plates of window and door framing shall be treated with an approved wood preservative in accordance with the applicable code. 15. Structures in all seismic zones are limited to two stories with basement and maximum 10- foot unsupported wall heights. Any exception shall be approved by structural plan check supervisors. 16. The is limited to use as a structural concrete wall lateral-force resisting system in Seismic Design Categories A and B under the 2008 LABC. Page 4 of 8

(a) (b) Figure 1 (a) APEX Block TM Plan View (b) Isometric View Page 5 of 8

Figure 2 Lintel and APEX Block TM Layout Page 6 of 8

Figure 3 Reinforcement Placement Page 7 of 8

DISCUSSION The revision is to add the condition that the APEX Block Interlocking System is limited to use as a structural concrete wall lateral-force resisting system in Seismic Design Categories A and B under the 2008 LABC. The report is in compliance with 2008 Los Angeles Building Code. The approval is based on tests in accordance with ICC ES Acceptance Criteria (AC 15). This general approval will remain effective provided the Evaluation Report is maintained valid and unrevised with the issuing organization. Any revision to the report must be submitted to this Department for review with appropriate fee to continue the approval of the revised report. Addressee to whom this Research Report is issued is responsible for providing copies of it, complete with any attachments indicated, to architects, engineers and builders using items approved herein in design or construction which must be approved by Department of Building and Safety Engineers and Inspectors. This general approval of an equivalent alternate to the Code is only valid where an engineer and/or inspector of this Department has determined that all conditions of this Approval have been met in the project in which it is to be used. YEUAN CHOU, Chief Engineering Research Section 201 N. Figueroa St., Room 880 Los Angeles, CA 90012 Phone - 213-202-9812 Fax - 213-202-9942 TV:tvo RR/MSWord2003 R12/01/09 2C/ACI318-05 Page 8 of 8