European Timber Windows & Doors

Similar documents
ENERGY EFFICIENT GLASS LESS ENERGY, MORE SAVINGS, BETTER FUTURE

SageGlass. SageGlass Product Guide. Dynamic glass for a changing world

NEED FOR A CORRECT GLASS DESCRIPTIVE CODE: ENERGY-CODING

Armorcoat 2 Mil Clear

Selecting Energy Efficient New Windows in Illinois

Selecting Energy Efficient Replacement Windows in Arizona

Introduction to basics of energy efficient building design

Product information Vertical window element VFE

VANTAGE ENERGY HIGH PERFORMANCE WINDOWS AND DOORS FOR EFFICIENCY & COMFORT

SGG PLANITHERM TOTAL New generation advanced performance low-e glass

Selecting Energy Efficient New Windows in Tennessee

Product information Centre-pivot white-painted roof window GGL

Selecting Energy Efficient New Windows in Nevada

WEEDOO - SA CONSTRUCTION TECHNOLOGY

Product information Roof balcony CABRIO GDL

Multi-Cavity Insulating Glass Units

How can we improve the performance of mid-century office buildings while preserving our architectural heritage?

Product information Additional window element GIU

Windows. inspired by you.

Windows. inspired by you.

Product information Roof terrace GEL + VEA/VEB/VEC

Attached Solar Greenhouse Plans for a solar heated greenhouse attached to your home

EXPERIENCE INOVO IN ACTION

Embrace the long shadows of the late afternoon. Embrace your sense of style. Embrace the compliments with just a touch of humility.

3 PRINCIPLES ARCHITECTS NEGLECT

OPTIWIN MOTURA. Technical Description. Synopsis:

Energy-efficient weatherization

Energy Efficient Glazing Design. John Ridealgh Off-Line Coatings Technology Group Pilkington European Technology Centre

Smart. Easy. Profitable.

Modelling Analysis of Thermal Performance of Internal Shading Devices for a Commercial Atrium Building in Tropical Climates

Double Glazed Windows & Doors

World s best-performing glass curtain wall

Insulated double and triple glass units, custom-built to specification and manufactured to the highest standards. Insulated glass units

SECTION SPECIAL FUNCTION GLAZING

SCHOTT UK Ltd Sales Office Drummond Road Stafford ST16 3EL Phone: Fax:

CATALINA-QT QUADRATHERM ULTIMATE DUAL PANE INSULATION SYSTEM PREMIUM SERIES VINYL WINDOWS FEATURING ANLIN S EXCLUSIVE

APR TECHNICAL note. Six-Star Concrete Housing. Six-Star Concrete

MorrisonWindows. Features and BenefIts. Insulated Glass Units. Options. ProfIle Colour Options. 500/508 Series Window

Designing windows that deliver both structural strength and thermal protection is our job. Doing it with style is our pleasure.

Comparative Analysis of Retrofit Window Film to Replacement with High Performance Windows

Maximize your security, protection and energy efficiency

144 Solstice Series. Give Your Home A Unique Appearance

THERMAL MASS CHAPTER 6. Understanding thermal mass. Seasonal effects of thermal mass

Passive House Object Documentation

Martin Ratcliffe Visiting Research Fellow, Centre for Energy Studies at LSBU Head of Roger Preston Environmental

Triple glazing. Choosing the ultimate energy efficiency for your home. A homeowner s guide

Topics. Glazing Materials. Glass. Hail damage. Light transmittance through glazing material. Glass Rigid panels Film plastic.

Clear float glass. Pilkington OptiView. Anti-reflective Glass

Stadtwerke Konstanz Customer Centre, Constance

Veka Evolutions Commercial Window Program

Solar-Control Glazing. Visionary Façade Concepts

HomeMaker3 Windows and Doors

Available online at ScienceDirect. Procedia Engineering 146 (2016 ) 60 68

warm, secure and beautiful Aluminium WINDOWS

The Technical Merit of Double Facades for Office Buildings in Cool Humid Climates

Convection Conduction

INTELLIGENT GLASS SYSTEMS

Triple glazing. Choosing the ultimate energy efficiency for your home. A homeowner s guide

Encompass by PELLA COMPETITIVELY PRICED VINYL WINDOWS AND PATIO DOORS

Building Code requirements for house insulation

Infosheet. Planibel Coloured. the range of AGC tinted float glasses. You have printed. Green, PrivaBlue, Dark Blue, Grey, Bronze, Azur, Dark Grey

ENERGY STAR Qualifying Criteria for Residential Windows, Doors, and Skylights Sold in Canada Version 3.0 October 1, 2010

THE INFLUENCE OF ENVELOPING ON ENERGETIC AND ECOLOGICAL EFFICIENCY OF PASSIVE HOUSES

BI-FOLD WINDOWS. Nothing between you and a view. McDonald Jones Homes

Observation of Liquid-filled Window without Presence of Liquid in Test Chamber

Windows & Doors Bushfire & Energy Efficient Solutions Tony Paarhammer Paarhammer Pty. Ltd

High Performance Window Film Imagine the possibilities. Decorative & Privacy Collection

BS 6206 KM BS EN KM 51961

Domes Pyramids Opening Rooflights Flatglass Rooflights

HRT 221 Greenhouse Structures and Management. John Biernbaum Department of Horticulture

PRACTICAL GUIDE MULTIVER RESIDENTIAL GLASS. Quebec. Version 2.0

VINYL SINGLE HUNG WINDOW

Chapter 5 Glazing Properties

Vinyl Replacement Windows and Doors

SILVERSTAR-Solar control glass

Vinyl Windows and Doors

Thermal Characteristics and Energy Performance of Double Skin. Façade System in the Hot Summer and Cold Winter Zone

Residential Glass Technical Guide

Convection. L 18 Thermodynamics [3] Conduction. heat conduction. radiation

Energy-Efficient Windows for Residential Windows

wood EUROPEAN ARCHITECTURAL SUPPLY FINE WINDOWS FOR ALL SEASONS products Makrowin MW88 G2 21 Makrowin MW88 23 Makrowin MW78 25 Makrowin MW AluClad 27

The effect of shading design and control on building cooling demand

SLIDING PATIO DOOR DESIGNS REHAU SYSTEM Construction Automotive Industry

Report for the U-value of a Door System in Accordance with BS EN ISO :2006. Product description:

VELUX America Inc. SPECIFICATION FOR MODEL QPF SELF-FLASHED FIXED SKYLIGHT SECTION UNIT SKYLIGHTS

Columbia Skylights may qualify your project for LEED points in the following categories: Columbia Skylights - Potential Contribution to LEED projects

Spandrel Glass Types and Recommendations

upvc ENERGY EFFICIENT WINDOWS AND DOORS

MikronWood Thermal Advantage Composite Window System Ideal for new construction and replacement applications in colder temperature climates

A High-Performance Window Series Exclusively From Vytex Windows

CI/Sf/B. (31) Ro5 (M5) April The width of single glazing. The warmth of double glazing. Pilkington Spacia Revolutionary vacuum glazing.

Solar control. Applications. solutions meet functional and styling demands (second part) Automotive glass

Analysis 2: Alternative Thermal Window Design

Vinyl Window Designs Ltd. 550 Oakdale Road Toronto, ON M3N 1W6 SPECIFICATIONS

PRODUCT SPECIFICATION SERIES 9000 WINDOW WALL THERMALLY BROKEN ALUMINUM CASEMENT / AWNING / FIXED WINDOW

Great Ocean Rd Ice Creamery

ELECTRONICALLY TINTABLE GLASS: THE FUTURE OF HIGH PERFORMANCE FACADES IS HERE

ADJUSTABLE SOLAR SHADING AND HEAT CONSERVATION LOUVRES FOR TRANSPARENT, MULTI-LAYERED GLASS FACADES

aluplast - Specialist for window and door systems IDEAL MORE LIGHT - MORE LIVING COMFORT

BUILT AROUND YOU ENERGY-EFFICIENT SOLUTIONS

Transcription:

European Timber Windows & Doors Providers of Passivhaus building performance solutions Passive House Pty Ltd 7-9 Raglan St North Melbourne VIC p 03 9329 3693 e info@passivehouse.com.au

Building Thermal Performance Background The Australian context: Figure 1 Winter Heat Losses & Summer Heat Gains in a typical uninsulated Australian home The climatic conditions in Australia are such that to effectively improve the thermal performance of a home, a multi front approach is required by improving insulation (reflective for summer and bulk for winter performance), sealing air leakage points to minimise air infiltration, and significantly improve window (including glazing) performance. Given the significant amounts of glazing in a typical Australian home, the performance of windows has a major impact on daylighting and thermal comfort. The following section describes in detail our unique and technically robust, responses to significantly improving the window thermal performance and comfort of a building.

European Timber Windows Windows are are often under specified in terms of thermal performance. In Australian homes they make up a significant portion of the building. Whilst the benefits of insulating a home are generally well understood, the requirements of a high performing window are very much less known. The optimal thermal performance and daylighting design of windows requires the careful consideration of their design, including frame material, weatherstrip sealing, glazing unit configuration, glass coatings, glass tinting, integration of blinds, etc. The heat loss and gain mechanisms involved in window thermal performance are complex: Figure 2 Heat transfer mechanisms of windows

Table 1 below compares the thermal conductivity of several window materials. Material k-value (W/mK) Aluminum 250 Steel 50 Glass 0.96 PVC 0.19 Hardwood 0.17 Softwood 0.12 Air (still layer) 0.024 Table 1 Thermal Conductivity of some window materials (Handbook of Chemical Engineering, Engineering Toolbox)) Aluminium is clearly a very poor insulator, being approximately 2000 times more thermally conductive than timber! On thermal performance alone, why would you choose an Aluminum window? Even amongst timber, the softwoods such as Western Red Cedar and European Redwoods are 40% better thermally performing than the hardwoods such as Vic Ash. The performance gap widens even more when you consider that the sash of a standard Australian window is made of 40 mm thick hardwood and has less than half the insulative performance of a standard European window made of 68 mm thick European Redwood. That s even before you get to consider the glass! Nowadays PVC windows with their European profiles are often considered a high performance alternative. However, PVC as a polymer is more conductive than hardwood and even more than softwood. OK the air gaps within the profiles help, but rarely mentioned is the fact that PVC windows and door sections are steel reinforced to provide rigidity, and as steel is a conductor, the thermal performance drops dramatically. PVC is never used alone. It is always mixed with heat stabilizers, lubricants, plasticizers, fillers, and other additives to make processing possible. PVC requires UV stabilisers for Sun protection. PVC material loses these stabilisers from the surface, so eventually loses protection. The innovation in windows in Europe is all in timber, because it s so great in performance, and adaptable in manufacturing. Typical window sash depths have increased from 56 mm to 68 mm and 78 mm (triple glazed) and are now headed beyond.

Obviously the glazing design and specification is also a very important consideration as detailed in Table 2 below (note R-value is the inverse of the U-value): Glazing U-value (W/m²K) R-value (m²k/w) Single Glazed 6 0.17 Double Glazed (std) 3 0.33 Double Glazed (improved) 2-3 0.33-0.5 Triple Glazed (std) 2 0.5 Double Glazed (high performance) Triple Glazed (high performance) < 1.5 > 0.67 < 1 > 1 Table 2 Heat Transfer Coefficient and Thermal Resistance of Glazing systems Figure 3 U-value of double glazed unit vs air gap width

With improved double glazing, the spacer gap of the double glazed unit is increased (16 mm is optimal) as it has a significant impact on the thermal performance of the glazing. The addition of inert gas such as Argon (Ar) also improves the thermal performance of the double glazing unit. However, the Argon dissipates over the lifetime of the glazing unit. Figure 4 Specification of double glazing Figure 5 Insulating spacer of a double glazed unit With performance double glazing, the addition of a metal oxide (clear) layer on the inner side(s) of the glass also has a significant impact, particularly in summer with east and west facing windows and unshaded northern windows. The E in low-e refers to emissivity. Emissivity is a measure of a material s ability to radiate energy. A material with low emissivity absorbs and radiates infrared energy poorly which is the key factor in reducing heat transfer. The lower the emissivity of a coating the better the glass performs in reducing heat transfer. A basic understanding of how low-e glass works, involves a closer look at the sun s energy and the solar spectrum: The sun s energy can be divided into different components such as (1) ultraviolet light; (2) visible light; (3) infrared energy. High levels of ULTRAVIOLET LIGHT can be harmful to humans and damage and fade furnishings. The desire is to exclude all of this component.

Figure 6 Solar Radiation Spectrum VISIBLE LIGHT is the desirable component giving us natural daylight, the cheapest source of lighting available (of course we may want to control glare). The INFRARED ENERGY component may be both desirable and undesirable. It is desirable when we seek sunshine and warmth for personal comfort and to naturally heat a room s interior (passive solar heat gain/heating). It is undesirable when it becomes discomforting, where the room becomes hot and strains are placed on people and air-conditioning systems. The infrared part of the spectrum (or what we feel as heat) consists of varying wavelengths. Short wave infrared heat energy is absorbed in the interior of the building by carpets, curtains, furniture, walls etc., and is changed into long wave infrared heat. Objects outside the building also absorb short wave energy and are changed into long wave heat energy. Low-E glass selectively allows specific portions of the sun s energy or the desirable wavelength components to be transmitted. When combined with spectrally selective tinted glass, low-e glass offers the ideal glazing solutions of low ultraviolet and high visible light transmittance, low shading co-efficient or solar gain and high insulation or U - values. This translates to a greater control of the internal environment, greater occupant comfort and lower heating and cooling costs.

Ideally for warm climates where summer heat reduction is a priority, a low emissivity coating should be on surface (2) for maximum performance. The coating on surface (2) minimises heat gain because it reduces heat build up in the air gap and heat transfer to the interior. This coating should always be directly applied to a tinted glass as a soft coat application. The coating in this situation works in conjunction with the tinted glass to reduce heat gain. In these situations the substrate glass should be heat strengthened or toughened to avoid thermal breakage. In cold climates where retention of heat is a priority, the low-e coating of panel clear glazed surface (3) is recommended. In these situations we are relying on the effects of passive solar heat gain to naturally heat the building s interior and the low-e coating to reflect any of the re-radiated heat back into the room. The shading coefficient can also be improved by up to 25% with the coating on surfaces (2), (3). For the combination of high performance low-e glass can be specified on either outboard or inboard glass with coatings on both surface(2) or (3), with a tinted glass as the outer pane. Another variation, spectrally selective low-e glass also block long wave radiation, but they have another important function. The multiple layers of silver in the coating allow the glass to selectively transmit and reject certain wavelengths of solar radiation. Spectrally selective low-e coatings are designed to maximize the transmission of visible light and to reduce transmission of longer wavelength heat in the near-infrared spectrum. In summary, low-e glass reduces heat loss, and spectrally selective low-e glass reduces heat loss and heat gain. In an insulated glass unit (IGU) or double glazed unit, various grades of laminated glass can be used to improve acoustic performance. Specifying window glazing is very important, quite complex and must be fully considered for optimal thermal performance. The orientation of the window, it s external shading or screening have significant impact on the thermal performance of the building. Preferably modeled with thermal computer software programs such as AccuRate or the Lawerence Berkley Laboratory Window 6.3, to enable the most favourable specification for the desired building performance. Figures 7, 8 & 9 below depict insulated double glazed units, and highlight at least one surface of low emissivity coating or tinted glass for improved thermal performance. In addition, tinting of the outer-pane is also very effective in reducing summer heat gain:

Figure 7 Double glazing configured for summer performance, solar passive winter Figure 8 Double glazing configured for summer performance Figure 9 Double glazing configured for winter performance

Also important is the full perimeter sealing of the window sash: Full perimeter seals (outer & inner possible) Figure 10 Full perimeter seals Plus the use of a (European standard) and a multipoint locking system to ensure that the seal is fully activated for closure: Figure 11 European standard multipoint active locking systems

Figure12 European Timber Windows, Doors & Façades manufactured in Australia by Passive House Pty Ltd