N-SERIES: NTH3500 SPECIFICATIONS Hollow Metal Sliding Door System

Similar documents
FOUR FOLD DOORS-WITH SINGLE OVERHEAD MTD OPERATOR

SECTION [ ] COILING COUNTER DOORS. Display hidden notes to specifier. (Don't know how? Click Here)

SECTION RADIO FREQUENCY SHIELDING ENCLOSURE RF Welded System

SECTION SECTIONAL OVERHEAD DOORS

SECTION OVERHEAD COILING FIRE DOORS MODEL 662 OVERHEAD COILING COUNTER FIRE DOORS WITH INTEGRAL FRAME

SST-II HYDRAULIC BI-FOLD SPECIFICATIONS

UFGS (April 2006) UNIFIED FACILITIES GUIDE SPECIFICATIONS

SECTION SECTIONAL OVERHEAD DOORS 522 SERIES ALUMINUM SECTIONAL OVERHEAD DOORS. Display hidden notes to specifier. (Don't know how?

A. Product Data shall be provided for each type of product indicated.

Westgate Entrematic, Parking Security Gates Section OVERHEAD SECURITY GATE Prepared by: Digicon Information Inc. Page 1

B. Polyethylene samples shall be submitted for Owner approval of color and quality.

SECTION ACCORDION FOLDING PARTITIONS

SINGLE SWING DOOR PAIRED SWING DOOR

MODERNFOLD GWS 100SR-G MOVEABLE GLASS WALLS

1. Vertical reciprocating conveyor, Hydraulic straddle VRC.

Series - 1

AJONES AIRWAYS, LLC CLEVELAND REGIONAL JETPORT Sliding Hangar Doors SBA SECTION SLIDING HANGAR DOORS

SECTION CHAIN LINK FENCES AND GATES (PARK)

Page 1 PRODUCT DESCRIPTION SECTION SECTIONAL OVERHEAD DOORS MODEL 900 PRODUCT FEATURES

COLLEGE CLASSROOM & DORMITORY SPECIFICATION SECTION 08100

NORTHWESTERN UNIVERSITY PROJECT NAME JOB # ISSUED: 03/29/2017

B. Shop Drawings: For metal lockers. Include plans, elevations, sections, details, and attachments to other work.

1. Section Steel Doors and Frames. 2. Section Flush Wood Doors 3. Section Aluminum Storefront Doors.

SECTION CLIMBING WALLS

AMBICO Limited Section and RFI\EMI SHEILDED STEEL DOOR AND FRAME ASSEMBLIES Page 1

SECTION CRL50 AND CRL51 HEAVY GLASS TOP HUNG SLIDING DOOR SYSTEMS

Therma Series Insulated Overhead Doors, by Northwest Door Section SECTIONAL DOORS Digicon Information Inc.

Central Dartmouth Section Exterior Envelope Renovations METAL-CLAD WOOD DOORS Page 1 of 5 Dartmouth, NS

ANSI/ ASME HST Performance Standard For Overhead Electric Wire Rope Hoists

800 Series Aluminum Overhead Doors, by Northwest Door Section ALUMINUM SECTIONAL DOORS Digicon Information Inc.

SECTION RADIATION SHIELDING ENCLOSURE Low Intensity Radiation Protection

This guide can be used to prepare a specification for incorporating free standing jib cranes into a competitively bid construction project.

DIVISION 10 SPECIALTIES SECTION OPERABLE PARTITIONS

EDGEWATER, FLORIDA JUNE 14, 2010

1. Hangers and supports for electrical equipment and systems. 2. Construction requirements for concrete bases.

Hardware. A. PRODUCT DATA: Submit manufacturer's technical information for each item of hardware.

Specifiers: Click on the icon in the WORD toolbar to reveal detailed instructions

Series 3000 Pocket Doors

SECTION MODULAR GALVANIZED RF SHIELDING SYSTEM SPECIFICATIONS

SECTION SECTIONAL OVERHEAD DOORS

SECTION ALUMINUM WINDOWS

SECTION PRE-ENGINEERED MEMBRANE STRUCTURE

PASSAIC COUNTY TECHNICAL INSTITUTE CCA 1422 NEW S.T.E.M. BUILDING 2017

SECTION LAGUNA SERIES TOP HUNG SLIDING DOOR SYSTEM

SECTION ALUMINUM STORM WINDOWS

SECTION PERSONNEL DUTY LOCKERS. 1. FPPL Series Police Personnel Duty Lockers, including the following:

GUIDE SPECIFICATION EXETER VERSA SHIELD SECURITY SCREEN SYSTEM

SECTION HANGERS AND SUPPORTS FOR ELECTRICAL SYSTEMS

SECTION METAL FLOOR PLATE STAIRS

HIGH MAST CAMERA POLE ASSEMBLY GENERAL

UNIFIED FACILITIES GUIDE SPECIFICATION

Acousti-Seal Encore Paired Panel (10650) Operable Partitions

Union County Vocational - Technical Schools Scotch Plains, New Jersey

SECTION Summit Phenolic Lockers (Solid Phenolic Lockers)

NORTHWESTERN UNIVERSITY PROJECT NAME JOB #

SECTION MECHANICAL SPECIFICATION GRIT COLLECTION EQUIPMENT

A. Submit the following in addition to the standard requirements.

SECTION ROOF ACCESSORIES

SECTION CHAIN-LINK FENCES AND GATES 02821/1

Section SECTIONAL INSULATED STEEL DOORS

A. Access doors and frames are part of an access door and frame allowance.

Division MEDICAL EQUIPMENT SUPPORT SYSTEMS PART 1 GENERAL

Façade Architectural Wall Panel System - Guide Specification 3/11/2017 SECTION FRAMED DECORATIVE PANEL SYSTEMS PART 1 - GENERAL 1.

Aluminum-Framed Entrances and Storefronts

The Contractor is responsible for quality control, including workmanship and materials furnished by his subcontractors and suppliers.

This guide can be used to prepare a specification for incorporating free standing jib cranes into a competitively bid construction project.

SECTION ALUMINUM-FRAMED STOREFRONTS

Specifications for FL-100 Soffit Panel

SECTION BASIC ELECTRICAL MATERIALS AND METHODS

SECTION NON-STRUCTURAL METAL FRAMING

Series - 1

SECTION U.S. ALUMINUM SERIES BAL-350 HURRICANE RESISTANT BALCONY/TERRACE DOOR

SECTION TURBINE VENTILATORS

SECTION 1043 FENCE MATERIAL

Northpointe Renovation EPN #1701 F/A Project #17027 September 8, 2017

SECTION STEEL DECKING

Architectural Single-Hung Aluminum Window Series L701T SH-AW130 GUIDE SPECIFICATION

SECTION PLATE CONNECTED WOOD TRUSSES

SECTION METAL BUILDING SYSTEMS

GLASS WALL SPECIFICATIONS

WALL MOUNTED ARTICULATING JIB CRANE

Student Services & Classroom Addition

SECTION (Master Template Final-05) ELECTRICAL BOXES. A. Provide boxes for electrical equipment and wiring devices as follows:

SIERRA MODEL 12 X 24 SPECIFICATIONS

C. Section Metal Fabrications: Steel frame and supports.

SECTION ACOUSTICAL PANEL CEILINGS

A. This Section includes automatic entrance door systems operating as follows: 1. Swinging operation.

PF-Series Gantry Crane

PIPE AND TUBE RAILINGS

Daytona Beach Pier Building Renovation Jun 2010

VPL-3200B Residential Vertical Platform Lift Technical Specifications

PRESTON HEALTH SERVICES ARCHITECT'S NO. 2700

SECTION VINYL ACRYLIC CLAD WOOD DOORS PART 1 GENERAL 1.1 RELATED DOCUMENTS

GLASSWALL SPECIFICATIONS

HANGERS AND SUPPORTS FOR HVAC PIPING AND EQUIPMENT SECTION HANGERS AND SUPPORTS FOR HVAC PIPING AND EQUIPMENT

SECTION METAL FABRICATIONS

UNIFIED FACILITIES GUIDE SPECIFICATIONS

SECTION DECORATIVE METAL FENCES AND GATES

SECTION HEAVY GLASS TOP HUNG SLIDING BI-FOLD DOOR SYSTEMS

FRP Baffle Wall Standard Specification-Section 11350

Transcription:

Version 5.22.13 N-SERIES: NTH3500 SPECIFICATIONS Hollow Metal Sliding Door System OPTIONS ARE LISTED IN BOLD, PLEASE MODIFY THESE AREAS AS NEEDED BASED ON YOUR PROJECT CONSULT MANUFACTURER FOR ADDITONAL OPTIONS OR MODIFICATIONS PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 1 Specifications, apply to this section. 1.2 SUMMARY A. This section includes horizontal sliding door systems. B. Operation of horizontal sliding door systems includes the option of belt driven or chain driven operator as appropriate for the door size and weight. 1.3 SUBMITTALS A. General: Submit each item in this Article according to the Conditions of the Contract and Division 1 Specification Sections. B. Product Data for each type of product specified consisting of manufacturer s technical Product Data and installation instructions for each type of door required, including data substantiating that products comply with requirements. C. Submittal Drawings showing fabrication and installation of top hung, sliding doors including plans, elevations, sections, details of components, hardware, operating mechanism and attachments to the other units of Work. Include wiring diagrams for coordination with electrical trade. 1.4 QUALITY ASSURANCE A. Doors shall be designed to withstand external or internal horizontal wind loads of 20 pounds minimum per square foot. The maximum allowable deflection shall not exceed 1/120 of the spam. Fiber stresses in main members shall be limited to 27,000 pounds per square inch. Steel frames shall be designed in accordance with the AISC Steel Construction Manual. NTH3500 SERIES, SLIDING DOORS 1

1.5 DELIVERY, STORAGE AND HANDLING A. Store delivered materials and equipment in dry locations with adequate ventilation, free from dust and water, and so as to permit access for inspection and handling. B. Handle materials carefully to prevent damage. 1.6 WARRANTY A. The door manufacturer shall provide a written standard limited warranty for material and workmanship. PART 2 - PRODUCTS 2.1 MANUFACTURERS A. Manufacturer: Single, bi-parting and tele-slide sliding doors shall be the NTH3500 Series Hollow Metal Sliding door manufactured by Door Engineering and Manufacturing, LLC, 400 Cherry St, Kasota, MN. 56050, (800) 959-1352. Equal products by other manufacturers approved in advance. 2.2 MATERIALS A. Steel Tube: ASTM A513 and ASTM A500/A500M B. Steel Sheets: Steel sheets of commercial quality, complying with ASTM A1011/A1011M hot-rolled steel sheet. C. Hardware: Manufacturer s standard components, galvanized or zinc plated. 2.3 DOOR PANEL CONSTRUCTION A. Door thickness: Doors shall have a minimum nominal thickness of 1-3/4. B. Core: Structural core of resin impregnated Kraft honeycomb bonded under pressure to both face sheets. C. Face Sheets: Steel sheet shall be a minimum of 18 or 16 gauge A-60 galvannealed steel. D. Interior Framing: Interior framing channel shall be a minimum of 14 gauge galvannealed steel. E. The flush pulls, 14 gauge armor edge, trail door interlock, and bottom guide channel shall be factory welded or screwed to the panels. F. Factory Finish: NTH3500 SERIES, SLIDING DOORS 2

Option 1: Manufacturer s standard structural primer, field painting specified in section XXXXX. Option 2: All exposed steel shall be finished with manufacturer s standard epoxy primer and polyurethane top coat. Customer to select from Manufacturer s standard color chart. G. Multiple Panels: Shall be field assembled using an "H" channel splice column, top armour edge and bottom stay roller assembly to lock one panel into the other to form a solid one piece unit. Splice column shall have no exposed fasteners. 2.4 HARDWARE A. All hardware for the door shall have a primer, galvanized, or zinc plated finish. The hardware shall include box track, adjustable track brackets, adjustable wall brackets, adjustable concealed stay rollers, 6" x 6" wall washers and wall bolts. The box track shall be a minimum of 14 gauge steel. Also included is (1) pair of four-wheel ball bearing hangers per panel. B. Mounting Hardware: Shall include all necessary wall washers and through wall bolts with nuts and washers. 2.6 OPTIONS A. (Option) Gasketing: Provide brush-type seals at head, jambs and sill. B. (Option) Pass Doors: Shall be 1 ¾" x 3'-0" x 7'-0" and have 1 ½ pair heavy duty hinges, track bar closer and a mortised latch set or panic device. C. (Option) Vision Panels: Provide vision panels of the type, size, shape and location as noted on the drawings. D. (Option) Track Hoods: Provide track weather-hood formed from galvannealed steel sheet. E. (Option) Locking: Provide cane bolts or mortised sliding door lock as required. F. (Option) Monorail Notch: Provide monorail notch as required. Include weatherseals to be trimmed in the field to seal around the monorail beam. G. (Option) Crush Plates: Recommended when wall material is not solid concrete. 2.7 OPERATOR SYSTEM A. Operator System, choose from the following: Option 1: Provide Leopard 2 sliding door operating system. Designed for high cycle, high capacity and custom/specialty applications. Please consult factory. NTH3500 SERIES, SLIDING DOORS 3

Option 2: LiftMaster SD or GSD series sliding door operator for low to medium cycle applications. Please consult factory. A. Electric motor shall be of sufficient size to operate doors under normal operating conditions at no more than 75 percent of rated capacity. B. Electric Controls: Controls shall be furnished by the door manufacturer and shall be complete for each door, and built in accordance with the latest NEMA standards. Incoming electrical shall be (Choose One): 120VAC single phase, 208VAC single phase, 208/230VAC 3-phase, 480VAC 3-phase. 1. Controls shall include a variable frequency drive, along with a self diagnostic logic controller with digital message display or LED indicators. Controller shall include programmable close time delays and maximum open and close runtime timers. 2. Motor starters shall be magnetic reversing, factory wired with overload and under voltage protection, and equipped with mechanical interlocks. All control components shall be enclosed in one enclosure with a wiring diagram placed on the inside of the cover. 3. Enclosures shall be NEMA 4 with disconnect switch. 4. Pushbuttons for each door shall include one (1) momentary pressure threebutton push-button station marked OPEN, CLOSE and STOP. Push button enclosure shall be NEMA 4. 5. Proximity switches and/or digital encoder shall stop the door in the full open and close positions 6. Safety Edges: Provide electric safety edges on leading edge of all doors to reverse door upon contact with obstruction. 7. Photo Eyes: Provide one interior and one exterior mounted photo eye (sender/receiver type) with mounting brackets. Photo eyes shall be NEMA 4X. 8. (Option) Loop Detectors: Provide open and/or safety loop detectors as required. Control panel shall have an Auto/Manual switch for activating and deactivating the open loop function. 9. (Option) Radio Controls: Where required, provide (1) radio receiver and (xx) single button remote controls. 10. Wiring: Door manufacturer shall supply controls only. Electrical contractor shall install controls and furnish and install conduits and wiring for jobsite power and control wiring. NTH3500 SERIES, SLIDING DOORS 4

PART 3 - EXECUTION 3.1 INSTALLATION A. Install sliding doors in strict accordance with the approved drawings by qualified door erection crews. All door openings shall be completely prepared by the general contractor prior to the installation of the doors. Permanent or temporary electric wiring shall be brought to the door opening before installation is started and shall be completed so as not to delay the inspection test. B. Door shall be set plumb, level and square, and with all parts properly fastened and mounted. All moving parts shall be tested, adjusted and left in good operating condition. 3.2 ADJUSTING AND CLEANING A. Inspection of the doors and a complete operating test will be made by the installer in the presence of the general contractor or architect as soon as the erection is complete. Any defects noted shall be corrected. After door approval in the above test, the general contractor must assume the responsibility for any damage or rough handling of the door during construction until the building is turned over to the owner and final inspection is made. B. Clean surfaces and repaint abraded or damaged finished surfaces to match factory-applied finish. END OF SECTION NTH3500 SERIES, SLIDING DOORS 5