ROCKWOOL FLEXI Insulation Application Guide

Similar documents
SOUND SOLUTIONS TO MEET THE APPROVED DOCUMENT E (2003 EDITION) August 2008

Loadbearing timber joist floors

June Residential Refurbishment Separating walls

Part E robustdetails. robustdetails. January 2017 Update Pack. Dear Colleague,

Garage Conversion - Between and Under Joist Applications

GypLyner UNIVERSAL Metal framed wall lining system

GypLyner. GypLyner. Metal framed wall lining system. All our systems are covered by SpecSure when using genuine Gyproc and Isover products.

E-Cousti Solutions Guide

Specialists in Acoustic Flooring and House to Flat Conversions

Ceiling Attenuation Class Systems SYSTEMS 280

The Passive Fire Protection Handbook

GypLyner UNIVERSAL Metal framed wall lining system

ACOUSTIC SUPPLIES. For Acoustic Solutions you can SHOUT about

Separating walls. Countryside Properties, Lock 38, Stoke-on-Trent

F L O O R S A N D C E I L I N G S

CasoLine MF Concealed grid MF suspended ceiling system

CasoLine MF Concealed grid MF suspended ceiling system

HP Partial Fill. Robust, long-lasting protection

Section 11 FIRE STOPPING

Product Application Guide

Typical detail: New roof with breathable underlay

SOUND INSULATION TESTING IN DWELLINGS

Thermal Laminate Board.

URSA MINERAL WOOL URSA Acoustic Roll

Day Night Day Night Day Night Residential site and amphitheatre Green Non residential site boundary Red

SECTION E Ceiling Systems. Contents. Introduction. Design Considerations. Installation. Components. System Specifications. Floor/Ceiling Systems

Multi-layer Insulation Blanket for Walls

Xtratherm Thin-R Thermal Liner (XT/TL Grade)

Product Information Sheet

Ductslab and Ductwrap

RAINSCREEN DUO SLAB. Non-combustible thermal insulation

SECTION D Masonry Wall Systems. Contents. Introduction. Design Considerations. Installation. Components. System Specifications.

FIRE PROTECTION. GTEC Shaftwall systems 244 GTEC Shaftwall Stairwell systems 248 GTEC Horizontal Shaftwall systems 249 GTEC Encasement systems 250


FIRE PROTECTION AND PERFORMANCE DRY LINING BOARD THE ULTIMATE IN FIRE PROTECTION! 91 mins fire integrity and 86 mins fire insulation on 9mm board

External Steel Stud and Top Hat Walls. Details SYSTEMS 176 NON-FIRE RATED SYSTEMS 176 FIRE RATED SYSTEMS 178 BRICK VENEER SYSTEMS 183 INSTALLATION 185

Building Design Data

TECHNICAL GUIDANCE XXXX 2015 EXXON QUESTION ANSWER. page 1 of 9

SINTEF Building and Infrastructure confirms that. Separating floors with Hunton Silencio 36 / Hunton Silencio Thermo


C04. S05. P02 P14 GypWall quiet sf

Tiling Tiling Finishes C08

EcoHome-Insulation.com. Aluminium Foil Bubble Insulation. General Purpose Insulation. Dry Lining. Cavity Wall. Insulation System.

SECTION B Steel Frame Wall Systems. Contents. Steel Stud Selection Tables. Introduction. Design Considerations. Installation.

C05. S03. P02 P08 FireWall

Multi-layer Insulation Blanket for Walls

URSA MINERAL WOOL URSA Cavity Batts

The extra strong, extra durable, sound resistant system that you can direct fix to

CI/SfB. November Design Guide Concrete block masonry

Staggered stud acoustic partition system

June Non - Residential Refurbishment Internal lining walls

Benefits.

Multi-layer Insulation Blanket for Walls

The Celotex Handy Guide

Staggered stud acoustic partition system

Builders Merchants Price List 2017

T-Barrier System. Masonry Applications. Satisfying Fire, Thermal and Acoustic Requirements at the Combined Party Wall and Pitched Roof Junction

Tiling Tiling

THERMAL LAMINATES. for roofs, walls, floors and soffits

Boards. Products - Boards.

GTEK TM SOUND GTEK TM IMPACT

June Residential New Build Render and cladding walls

SOUND SOLUTIONS FOR YOUR HOME. Controlling the volume of everyday living How to solve a problem you have with noise

Definition of Wall. A continuous, vertical structure Thin relatively to its length and height

HOW TO: BOARD BATHROOMS, WET ROOMS & SHOWERS

9/24/2015. Aalto! / ENG + ARC. Asuinrakennusten rakenneratkaisut. Requirements : Sound insulation requirements : Thermal insulation requirements :

Issue date: 1st May Key changes since original publication (July 2005):

Multi-layer Insulation Blanket for use in Walls

STEEL STUD, TRIMS AND ACCESSORIES FOR DRYWALL CONSTRUCTION MONTREAL TORONTO CALGARY EDMONTON VANCOUVER THE STRENGTH WITHIN

CI/Sfb (2 ) Rn7 M2 Fourth Issue June Product Selector INSULATION FOR ROOFS, WALLS & FLOORS. Low Energy Low Carbon Buildings

energy saving for the future

Floors Walls Roofs. Jablite Premium board Jablite board. APPLICATION: Internally Lined Pitched Roof PRODUCTS: Vencel Resil Limited

Acoustic Cradle Levelling System

Garage Conversions. Technical Issues

ARCHITECTURAL AND STRUCTURAL NOISE CONTROL SOLUTIONS

PITCHED ROOF SOLUTIONS

SEPTEMBER construction type cavity barriers. SP Firestop Systems. The purpose-made solution for cavity fire stopping

This page was. intentionally. left blank

Design. Boral CinemaZone Fact Sheet. Windows. Acoustic sealants. Sound absorptive panels. Ventilation. Floor coverings. The vision.

URSA MINERAL WOOL URSA 10 & URSA 20 DIVERSO Loft Roll

City of High Point Airport Overlay District Noise Level Reduction Design Standards

Part E robustdetails. robustdetails. April 2017 Update Pack. Dear Colleague,

June Residential Refurbishment Exposed soffit floors

For inhibiting the spread of fire and smoke in concealed spaces

3.1 Noise Overlay District

MATERIAL & COMPONENT SPECIFICATION DATE: 1 ST FEBRUARY 2015 ISSUE NO: 19

Aircrete blocks product guide

USGBORAL.COM SYSTEMS+ INTRODUCTION OUTRWALL BRICK VENEER WALLS EXTERNAL WALLS INNOVATIVE SYSTEMS SOLUTIONS

C06. S02. P02 P22 CasoLine mf

September Saddle Flooring Systems

Structural Products. Multideck 50-V3 Galvanised Steel Floor Decking System

Section Sound Control

Fire Barrier Systems. For inhibiting the spread of fire and smoke in concealed spaces

TW50. Insulation STANDARD DETAILS FOR 50 MM INSULATION BOARD IN A 100 MM CAVITY. Low Energy Low Carbon Buildings. Wall lining. Inner leaf blockwork

Jabfloor 70, 100, 150, 200, 250

Acoustic Detailing For Steel Construction

GENERAL INSTALLATION GUIDELINES

THERMAL MASS CHAPTER 6. Understanding thermal mass. Seasonal effects of thermal mass

BISON PRECAST FLOORING SPECIFICATION

SECTION NON-STRUCTURAL METAL FRAMING

Transcription:

ROCKWOOL FLEXI Insulation Application Guide

Pitched roof Rafters Intermediate Floors Internal Partitions Separating Floors Separating Walls ROCKWOOL FLEXI One product, many applications Choosing ROCKWOOL FLEXI is an easy decision as it can be used all over your home or building project, which is great value for money. External Framed Walls ROCKWOOL FLEXI can be used in: Pitched roof rafters Framed external walls Internal partitions and intermediate floors Separating walls and floors Timber suspended ground floors. The perfect fit for any framed construction ROCKWOOL s unique patented flexible edge along one side ensures the perfect fit is maintained when timber expands and contracts. ROCKWOOL FLEXI can be fitted between fresh timber and will expand into the wider space created when the timber has dried out and shrunk back. Other insulation may be displaced, resulting in cold spots or poor acoustics. ROCKWOOL FLEXI is the ideal multipurpose and multibenefit product for your home or building project 2 3

ROCKWOOL FLEXI Meeting the regulations Using ROCKWOOL FLEXI will assist you in achieving compliance to the relevant building regulations. ROCKWOOL FLEXI boasts an A1 European reaction to fire classification. Part L Thermal The perfect friction fit between frames and provides excellent insulation levels. ROCKWOOL FLEXI has a thermal conductivity of 0.038 W/mK at thicknesses between 50120mm and 0.035 W/mK for thicknesses of mm and above. Correct design and high performance insulation are key to meeting the requirements of Part L. Part B Fire Safety ROCKWOOL FLEXI boasts an A1 European reaction to fire classification, as defined in BS 135011. It is noncombustible and is fully tested in fire separation constructions. Part E Acoustics ROCKWOOL FLEXI works in two distinct ways to reduce noise; by impeding the transmission of sound through the structure, and through the absorption of sound at the surface. The structure of the fibres in ROCKWOOL FLEXI makes it ideal for use as a sound absorber. Details of acoustic performance are included in this guide. Fast and easy to install The unique flexible edge makes ROCKWOOL FLEXI easy to use and fast to install, ensuring you move on to your next job faster. ROCKWOOL FLEXI has been designed to fit all typical metal and timber frame spacing, without the need for cutting or waste. It is easy to install and does not slump. To install simply push in the specially designed flexible edge......and let go for the perfect fit. 4 5

Acoustic Partitions Lightweight Timber Stud STUDS: 38 x 63mm at 0mm centres FACINGS: Single layer of 12.5mm acoustic plasterboard (11kg/m 2 ) each side INFILL: Minimum 50mm ROCKWOOL FLEXI Lightweight Metal Stud STUDS: 50mm metal studs at 0mm centres FACINGS: One layer of 12.5mm standard plasterboard (8kg/m 2 ) each side INFILL: Minimum 50mm ROCKWOOL FLEXI Typical Office Partition STUDS: 38 x 75mm timber studs at 0mm centres FACINGS: Two layers of 12.5mm standard plasterboard (2 x 8kg/m 2 ) each side INFILL: Minimum 50mm ROCKWOOL FLEXI Enhanced Performance: Schools, Offices and Public Buildings STUDS: 70mm metal studs at 0mm centres FACINGS: Two layers of 15mm standard plasterboard (2 x 13kg/m 2 ) each side INFILL: Minimum 70mm ROCKWOOL FLEXI Acoustic Partitions Acoustic Partitions Lightweight Timber Stud 40 30 3.0 Lightweight Metal Stud 41 30 2.5 Typical Office Partition 46 3.0 Enhanced Performance: Schools, Offices and Public Buildings 57 90 4.6 6 7

Separating Floors Timber Platform Floor With Recessed Downlighters (new build) 18mm T&G flooring grade chipboard on 15mm acoustic plasterboard (13kg/m 2 ) on 50mm ROCKWOOL Rockfloor on 15mm OSB on 200 x 50mm timber joists at 400mm centres 100mm ROCKWOOL FLEXI between joists Resilient bars fixed at right angles to joists at 400mm centres Ceiling finish, two layers of 15mm acoustic plasterboard (2 x 13kg/m 2 ) Aspect lighting mm downlights (1 per 1.8m 2 ) with Tenmatt FF 109 downlighter covers. Separating Timber Platform Floor Construction (new build) 18mm T&G flooring grade chipboard spot bonded to 15mm plasterboard (total mass 28kg/m 2 ) 50mm (min) ROCKWOOL Rockfloor resilient layer Min 15mm OSB floor deck on timber floor joists (200 x 50mm @ 400 ctrs.) 100mm ROCKWOOL FLEXI between joists Resilient bars fixed at right angles to joists at 400mm centres Ceiling finish 2 layers 15mm plasterboard 26kg/m 2. Separating Timber Floor Treatment: Platform Floor with Absorbent Material (material change of use) Min two layers of board material to provide min total mass 25kg/m 2 spot bonded together with joints staggered (e.g. 18mm T&G flooring grade chipboard and 19mm plasterboard plank) Floating layer loose laid over Rockfloor 25mm (min) ROCKWOOL Rockfloor resilient layer laid on existing floor deck on existing timber floor joists 100mm ROCKWOOL FLEXI between joists Existing ceiling upgraded to 20kg/m 2. If existing ceiling is of lath and plaster it should be retained providing it satisfies Part B Fire Safety (if in doubt, underdraw with an additional layer of 12.5mm fire resistant plasterboard and screw into joists). Separating Floors Separating Timber Platform Floor Construction (new build) Upgraded Fire Floor (existing) Upgraded Fire Floor (existing) 19mm T&G floor boarding 195 x 47mm GS grade softwood joists at 400 mm centres 100mm ROCKWOOL FLEXI supported by continuous run of 25mm wire mesh stapled to sides of joists and laid over ceiling 9.5mm plasterboard (or good condition lath and plaster). Reduction Benefits (db) 53 40 Impact Noise Reduction Benefits (db) 54 Separating Floors Reduction Benefits (db) Impact Noise Reduction Benefits (db) Timber Platform Floor with Recessed Downlighters (new build) 53 54 Separating Timber Floor Treatment: Platform Floor with Absorbent Material (material change of use 43 64 8 9

Internal Floors Separating Walls Conversion Work Timber Joist Internal Floor Within the Same Dwelling JOISTS: Timber joists at 400mm centres FACINGS: Standard 18mm T&G flooring grade chipboard, mass per unit area 12.4kg/m 2. Single layer of standard 12.5mm plasterboard, ceiling mass per unit area 8kg/m 2 INFILL: Minimum 100mm ROCKWOOL FLEXI between joists Separating New Build Metal Frame Wall Construction STUDS: 70mm metal C studs at 0mm centres FACINGS: Two layers of 15mm plasterboard (13kg/m 2 ) one side. Other side: Two layers of 15mm plasterboard (2 x 13kg/m 2 ) fixed to resilient bars (spaced at 0mm centres) INFILL: Minimum 70mm ROCKWOOL FLEXI between joists Internal Metal Joisted Floors Within the Same Dwelling JOISTS: Metal floor joists at 400mm centres FACINGS: Timber floor minimum mass per unit area 15kg/m 2 (e.g. 22mm chipboard). Single layer plasterboard, minimum mass per unit area 10kg/m 2 (e.g. 15mm standard plasterboard) INFILL: Minimum 100mm ROCKWOOL FLEXI between joists Separating Wall Existing Solid Masonry Wall STUDS: Independent timber or steel studs, minimum 10mm gap to be maintained between frame and existing wall FACINGS: 100mm minimum existing solid masonry wall plastered on both faces. Two layers of 15mm standard plasterboard (2 x 10kg/m 2 ) INFILL: 50mm ROCKWOOL FLEXI between studs avoiding flanking transmission: seal perimeter edges of new plasterboard with tape or ROCKWOOL Acoustic Sealant. If existing masonry wall is not plastered or less than 100mm thick then independent panels should be applied to both sides Internal Floors Separating Walls Conversion Work Timber Joist Internal Floor Within the same dwelling 40 30 Separating New Build Metal Frame Wall Construction 57 90 4.6 Internal Metal Joisted Floors Within the same dwelling 40 30 Separating Wall Existing Solid Masonry Wall 10 11

Separating Walls New Build Exterior Walls Separating Wall Timber Frame Twin Timber Frames (new build) Conforms with Robust Detail EWT 1. For use with timber framed dwellings and apartments. FACINGS: 240mm minimum between inner faces of wall linings. 50mm minimum gap between studs. Two or more layers of gypsum based board (total nominal mass per unit area 22kg/m 2 ) both sides INFILL: Minimum mm ROCKWOOL FLEXI both sides Timber Frame Wall With Tile Hanging STUDS: Studs to suit 0mm centres with 50mm. ROCKWOOL FLEXI between battens FACINGS: External tile hanging or weatherboard. 12.5mm standard plasterboard with VCL INFILL: ROCKWOOL FLEXI between the studs Separating Wall Steel Frame Twin Metal Frames (new build) Conforms with Robust Detail EWS 1. For use with lightweight steel framed dwellings and apartments. FACINGS: 200mm minimum between inner faces of wall linings. Two or more layers or gypsum based board (total nominal mass per unit area 2 x 11kg/m 2 ) both sides INFILL: Minimum 50mm ROCKWOOL FLEXI Timber Frame Cavity Wall STUDS: Studs at 400mm/0mm centres FACINGS: Outer brick or block with 50mm clear cavity. High performance breather membrane on OSB 12.5mm plasterboard with VCL INFILL: ROCKWOOL FLEXI between the studs Separating Wall New Build Exterior Walls Uvalue W/m 2 K FLEXI Thickness (mm) Separating Wall Timber Frame Twin Timber Frames (new build) Separating Wall Steel Frame Twin Metal Frames (new build) 50 50 3.0 3.0 Timber Frame Wall With Tile Hanging 0.27 0.22 0.18 100 180 Timber Frame Cavity Wall 0.23 0.19 180 12 13

Roofs Insulation at Rafter Level RAFTERS: 47mm timber rafters at 0mm centres FACINGS: Breather membrane and tiles outer. 25 mm service zone with high performance VCL and plasterboard inner INFILL: ROCKWOOL FLEXI between rafters Roofs Uvalue W/m 2 K Insulation at Rafter Level 0.24 0.19 0.18 FLEXI Thickness (mm) 180 200 The Ideal Choice For homes and commercial buildings alike ROCKWOOL FLEXI provides home owners with thermal and acoustic comfort. As well as providing a fire safe and environmentally sustainable solution to home insulation. Installation of ROCKWOOL FLEXI can also help reduce energy consumption, lowering the cost of heating your home. The ease of installation makes it the right choice for home owners. Schools, factories, offices, hospitals and industrial buildings all benefit from the use of ROCKWOOL FLEXI. It has been chosen in these projects to maximise energy efficiency and minimise CO 2 emissions, as well as provide acoustic comfort and a fire safe environment for people to work and learn in. Size and Usage Information Length and Width 1200mm x 0mm Thickness (mm) Coverage/Pack (m 2 ) 50 8.64 8.64 70 5.76 90 4.32 100 4.32 120 4.32 2.88 180 2.16 200 2.16 Length and Width 1200mm x 400mm Thickness (mm) Coverage/Pack (m 2 ) 50 5.76 100 2.88 1.92 14 15

Pencoed Bridgend CF35 6NY 01656 862 621 info@rockwool.co.uk RW17 106 01.07.17