Effect of Temperature on IC Signal Noise

Similar documents
Practical guidance for switching between anion and cation analysis systems

Determination of Oxalate and Other Anions in Bayer Liquor Using Ion Chromatography

Configuring the Dionex Modular HPIC system with an inline water purifier and inline calibration for trace anion determinations in ultrapure water

Next generation suppressor for ion chromatography. Thermo Scientific Dionex ERS 500 Electrolytically Regenerated Suppressor

Determination of Total Nitrogen and Phosphorus in Environmental Waters

Dionex Eluent Generator Cartridges

Determination of Cations in Hydraulic Fracturing Flowback Water from the Marcellus Shale

Determination of halogens in coal using combustion ion chromatography

PRODUCT MANUAL FOR THE. ELECTROLYTIC ph MODIFIER (EPM) EPM, P/N

Thermo Scientific. Dionex IonPac AS9-HC. Column Product Manual. P/N: May Part of Thermo Fisher Scientific

Determination of Trace Copper, Nickel, and Zinc in Boiling Water Reactors Using Nonsuppressed Conductivity Detection

Analysis of Glyphosate and AMPA in Environmental Water Samples by Ion Chromatography and On-Line Mass Spectrometry with Minimal Sample Preparation

Determination of Perchlorate in Drinking Water by Ion Chromatography

Dionex IonPac CS16-4µm and Dionex IonPac CS16-Fast-4µm

HIGH QUALITY, RELIABLE ION ANALYSIS SOLUTIONS FOR EVERY IC CHALLENGE THERMO SCIENTIFIC DIONEX PRODUCT PORTFOLIO

Sensitive Determination of Hexavalent. Brian De Borba, Lipika Basumallick, Jeffrey Rohrer

Monosaccharide and Sialic Acid Determinations in Biosimilars Using HPAE-PAD

The Effect of Working Electrode Gasket Thickness on the Sensitivity and Linearity of Carbohydrate Response by Pulsed Amperometric Detection

Determination of Sulfite in Food and Beverages by Ion Exclusion Chromatography with Pulsed Amperometric Detection

Determination of trace anions in ultrapure water using capillary ion chromatography

Errata. Product Manual for Dionex IonPac Cryptand Columns

Ion Chromatography Coupled to MS, a Powerful Approach for Polar Pesticides Determination

Development of Ultra-fast ph-gradient Ion Exchange Chromatography for the Separation of Monoclonal Antibody Charge Variants

HIC as a Complementary, Confirmatory Tool to SEC for the Analysis of mab Aggregates

Determination of Metal Cyanide Complexes in Solid Wastes by Anion-Exchange Chromatography with UV Absorbance Detection

Technical Guide. Thermo Scientific. Capillary High-Pressure Ion Chromatography. simplifying IC while increasing resolution and speed

A highly sensitive and robust 150 µm column to enable high-throughput proteomics

Determination of N-Methylpyrrolidine in Cefepime Using a Reagent-Free Ion Chromatography System

The analysis of polar ionic pesticides using ion-exchange chromatography coupled to mass spectrometry: turning negatives into positives

Leading the way innovative chromatography

EASY-Spray Columns. Guidance for column set up and installation Tips to maximize column lifetime

Chem 321 Lecture 23 - Liquid Chromatography 11/19/13

Concentration of Human Hormones in Drinking Water Using Solid Phase Extraction and Analysis by High Performance Liquid Chromatography

columns IonPac ICE-AS1 Ion-Exclusion Column Superior Chromatographic Performance Separates weakly ionized acids by differences in pk a

Methods for Determining Sugars and Hydroxymethylfurfural in Biomass

Blank Optimization Using Ultrapure Water Suitable for Trace Ion Analysis.

MassPREP On-Line Desalting Cartridge

Lifetime stability of size exclusion chromatography columns for protein aggregate analysis

A Fast and Robust Linear ph Gradient Separation Platform for Monoclonal Antibody (MAb) Charge Variant Analysis

Measurement of Bromate and Haloacetic Acids In Drinking Water by IC-MS/MS

Determination of Oversulfated Chondroitin Sulfate and Dermatan Sulfate in Heparin Sodium Using Anion-Exchange Chromatography with UV Detection

Application of Agilent AdvanceBio Desalting-RP Cartridges for LC/MS Analysis of mabs A One- and Two-dimensional LC/MS Study

Separation of Intact Monoclonal Antibody Sialylation Isoforms by ph Gradient Ion-Exchange Chromatography

A universal chromatography method for aggregate analysis of monoclonal antibodies

A Novel ph Gradient Separation Platform for Monoclonal Antibody (MAb) Charge-Variant Analysis

An Automated System for At-Line Process Analysis of Biopharmaceutical Fermentation Reactions

Econo-Pac High Capacity Ion Exchange Cartridges, 5 ml Instruction Manual. Catalog Numbers , ,

Sprint analysis of lubricating oils using the Thermo Scientific icap 7600 ICP-OES

Direct Determination of Cyanide in Drinking Water by Ion Chromatography with Pulsed Amperometric Detection

Microflow Liquid Chromatography Mass Spectrometry System. Nexera Mikros C146-E350

Electrochemical Detection

PURELAB CHORUS SYSTEMS

Quality-by-Design-Based Method Development Using an Agilent 1290 Infinity II LC

Preparative HPLC: Factors and Parameters that Directly Affect Recovery of Collected Fractions

Agilent AdvanceBio SEC Columns for Aggregate Analysis: Instrument Compatibility

Molecular Characterization of Biotherapeutics The Agilent 1260 Infi nity Multi-Detector Bio-SEC Solution with Advanced Light Scattering Detection

Automated Real-Time Determination of Bromate in Drinking Water Using LC-ICP-MS and EPA Method Application

Flexibility with. Preparative HPLC

Lenntech. Tel Fax

Analytical Instrument Qualification According to USP <1058>: Requirements and Examples for the Agilent 1290 Infinity LC System

Application Note. Author. Abstract. Biopharmaceuticals. Verified for Agilent 1260 Infinity II LC Bio-inert System. Sonja Schneider

Enhanced biodegradation of carbamazepine after UV/H 2 O 2 advanced. oxidation

LIFluor EnhanCE. for use with dsdna 1000 and dsdna 20,000 Kits

Improving Sensitivity in Bioanalysis using Trap-and-Elute MicroLC-MS

Maximizing Chromatographic Resolution of Peptide Maps using UPLC with Tandem Columns

Measurement and Control of Copper Additives in Electroplating Baths by High-Performance Liquid Chromatography

Fast Online Desalting of mabs Using a Reversed-Phase Desalting Cartridge for LC-MS Analysis

SCIEX Anion Analysis Kit For P/ACE MDQ and P/ACE MDQ plus Capillary Electrophoresis Systems. Instruction Guide

Technical Overview. Author. Abstract. Edgar Naegele Agilent Technologies, Inc. Waldbronn, Germany

A Modular Preparative HPLC System for the Isolation of Puerarin from Kudzu Root Extracts

Exploring Extra Sensitivity Using ionkey/ms with the Xevo G2-XS Q-Tof HRMS for Small Molecule Pharmaceutical Analysis in Human Plasma

Dionex OnGuard II Cartridges

Quantification of Drug Metabolites in Early-Stage Drug Discovery Testing

HEPARIN CALCIUM. Heparinum calcicum

Preparative HPLC is still the

Fast mass transfer Fast separations High throughput and improved productivity Long column lifetime Outstanding reproducibility Low carryover

Glyphosate and AMPA in drinking water

Characterization of mab aggregation using a Cary 60 UV-Vis Spectrophotometer and the Agilent 1260 Infinity LC system

ANALYSIS OF PESTICIDE RESIDUES IN DRINKING WATER AS PER BUREAU OF INDIAN STANDARDS USING THE AGILENT 7000 GC/MS/MS WITH PESTICIDES ANALYZER

UHPLC Separation of Triazine Herbicides at Elevated Temperature

Developing Robust and Efficient IEX Methods for Charge Variant Analysis of Biotherapeutics Using ACQUITY UPLC H-Class System and Auto Blend Plus

HPLC/FLASH Purification ADVANCE THE PACE OF YOUR DISCOVERY TO ACHIEVE THE RESULTS OF TOMORROW

On-line SPE-LC/MS/MS to Detect Organonitrogen and Triazine Pesticides at 10ng/L in Drinking Water

Size Exclusion Chromatography of Biosimilar and Innovator Insulin Using the Agilent AdvanceBio SEC column

ACETALDEHYDE. The procedure is applicable to corn syrups including those containing fructose, and to most other starch hydrolyzates (Note 1).

APPLICATION NOTE. UOP : Analysis of Trace CO and CO 2 in bulk H 2 and Light Gaseous Hydrocarbons by GC

REACTION TANKS WATER PURIFICATION THROUGH SERVICE DEIONIZATION

Automated in-line buffer preparation from readymade stock solutions in a mab process step

Controlling Agilent 1200 Series Rapid Resolution LC systems through Waters Empower chromatography data software. Technical Overview.

Optimization of Volatile Petroleum Hydrocarbons Analysis by Automated Headspace Using Method Development Tools

Streamlined Purification of Assay-Ready Oligonucleotides by Automated HPLC

Analysis of Suspected Flavor and Fragrance Allergens in Cosmetics Using the 7890A GC and Capillary Column Backflush Application

// XPLORER-NS. Full range Total Nitrogen, Total Sulfur instrument for the modern Laboratory.

Agilent MetaCarb Ca PLUS Carbohydrate Column Ca ++ Form User Manual Part No. A5205

Protein-Pak Hi Res HIC Column and HIC Protein Standard

Separation of Recombinant Human Erythropoietin (rhepo) using the European Pharmacopoeia Method on the PA 800 plus Pharmaceutical Analysis System

EPA Method 543: Selected Organic Contaminants by Online SPE LC/MS/MS Using the Agilent Flexible Cube

Flame Atomic Absorption Spectrometer (FAAS) Brand : PERKINALMER Model : PinAAcle 900T Custodian : PRADUP MESAWAT SOOKRUTHAI WONGSUBIN

Fraction Analysis of Cysteine Linked Antibody-Drug Conjugates Using Hydrophobic Interaction. chromatography. Agilent 1260 Infinity II Bio-Inert System

METHOD 25D - DETERMINATION OF THE VOLATILE ORGANIC CONCENTRATION OF WASTE SAMPLES. NOTE: Performance of this method should not be

Transcription:

TECHNICAL NOTE 179 Effect of Temperature on IC Signal Noise John E. Madden, Linda Lopez, Hua Yang, David G. Moore, Thermo Fisher Scientific, Sunnyvale, CA Keywords Conductivity detection, electrolytic suppression, Integrion, signal-to-noise, thermostatted compartment Introduction Noise is an important parameter of any analytical instrument and is defined as an unwanted modification of the signal from known or unknown sources. Ultimately the sensitivity of any chromatography detector is defined by its signal-to-noise ratio. The aim of this sensitivity optimization experiment is to increase signal, decrease noise, or some combination of the two. Equipment The results shown in this technical note were gathered on the equipment listed below. However, the principles of electrolytic suppression and conductivity detection are conserved no matter which IC system is used, so results should be similar across a wide range of IC instruments, including the Thermo Scientific Dionex ICS-5000 + system and Thermo Scientific Dionex Integrion HPIC system. Dionex Integrion HPIC system with the following features: Analytical pump Eluent degas Eluent generation (EG) 6-port injection valve Column oven Conductivity detector Thermostatted compartment Thermo Scientific Dionex Chromeleon Chromatography Data System (CDS) software, version 7.2 SR4

Reagents and Standards 18 MΩ-cm deionized (DI) water Fisher Scientific reagents, ACS Grade Standard Preparation A 10 g/l sulfate stock solution was prepared by dissolving 14.79 g of sodium sulfate in 1 L DI water. A 10 mg/l sulfate standard solution was prepared by diluting the stock solution. Dilutions were made with DI water without any pretreatment prior to injection. System Configuration The Dionex Integrion HPIC System with reagent-free ion chromatography (RFIC ) capabilities was configured according to standard RFIC system operating conditions as outlined in the Dionex Integrion HPIC system Operator s Manual. The suppressor was mounted in the thermostatted compartment; thus the temperature of the suppressor could be controlled by setting the thermostatted compartment temperature. An extended length of 0.007 i.d. tubing (25 cm) was used to connect the outlet of the column to the inlet of suppressor; this ensured thorough stabilization of the eluent temperature to the temperature in the thermostatted compartment before entering the suppressor. To ensure changes in detector compartment directly affect suppressor temperature, an extended length of 0.020 i.d. tubing (50 cm) was used to connect the outlet of the conductivity detector (CD) cell and the inlet of the suppressor regen. These extra lengths of tubing were used to isolate the impact of temperature on the various components in the system. Under normal operating conditions the tubing lengths should be minimized to optimize dead volume. The CD cell is installed inside the thermostatted compartment and has only heating ability. For stable operation, it must be kept at a temperature at least 7 C higher than the thermostatted compartment. Experimental Design In each experiment, data was collected over a 1 h period at each temperature after a 3 h equilibration period. Each data point represents an average of 60 one-minute noise readings. Error bars represent the standard deviation of these noise values. Conditions Columns: Eluent Source: Thermo Scientific Dionex IonPac AG11 (4 x 50 mm) Thermo Scientific Dionex IonPac AS11 (4 x 250 mm) Thermo Scientific Dionex EGC 500 KOH Eluent Generator Cartridge Thermo Scientific Dionex CR-ATC 600 Continuously Regenerated Anion Trap Column Eluent: 38 mm KOH, unless otherwise stated Flow Rate: 1.2 ml/min Column Temp: 33 C Inj. Volume: 15 µl Detection: System Backpressure: Suppressed Conductivity, Thermo Scientific Dionex ERS 500 (4 mm) Electrolytically Regenerated Suppressor, recycled eluent mode 113 ma, unless otherwise stated 2600 2800 psi Standards of 10 mg/l sulfate solution were infused into the injection loop from a 1 L polypropylene container. The standard was delivered via a gravity siphon feed. Results and Discussion It is important to isolate the effect of temperature on the conductivity cell from the effect of temperature on the suppressor. Thus, the Dionex Integrion HPIC system, with thermostatted compartment, is an ideal platform for studying these effects as the temperature of the suppressor and the cell can be controlled independently with the ability to cool in the thermostatted compartment. The first two experiments were designed to isolate the effect of temperature on the CD cell and suppressor respectively. The later experiments were designed to test the system under conditions where the CD cell and thermostatted compartment are maintained at a constant 7 C difference, but are varied together.

Effect of Variation of CD Cell Temperature Figure 1 shows the effect of varying the CD cell temperature on total conductivity signal noise while holding the suppressor temperature constant at 20 C. The results show that increasing the temperature of the CD cell results in a decrease in recorded noise on the signal. Effect of Variation of Table 1 and Figure 2 show the effect of varying the suppressor temperature on total conductivity signal noise while holding the conductivity cell constant at 47 C. This temperature was chosen to ensure the CD cell remained at least 7 C above the highest detector compartment temperature in the data set. 0.7000 0.6000 Noise as a Function of CD Cell Temperature The results show that increasing suppressor temperature results in an increase in recorded noise on the signal. Table 1 reveals that raising the suppressor temperature in the 15 25 C range has a moderate impact on noise, effectively adding 49% more noise to the signal. Raising the temperature above 25 C has an even greater effect on noise, increasing the noise nearly four fold at 40 C. Supp. Temp ( C) Signal Noise (µs) % Increase 15 0.328 20 0.402 23% 25 0.490 49% 30 0.726 121% 35 0.847 158% 40 1.228 275% 0.5000 0.4000 0.3000 0.2000 Table 1. Conductivity signal noise as a function of suppressor temperature. CD cell temperature was kept constant at 47 C. % Increase values are based on the 15 C baseline. 0.1000 25 30 35 40 45 50 CD Cell Temperature Figure 1. Suppressor temperature was kept constant at 20 C. Error bars show a single standard deviation of recorded noise values over a period of one hour. 1.6000 Noise as a Function of 1.4000 1.2000 1.0000 0.8000 0.6000 0.4000 0.2000 12 17 22 27 32 37 42 Figure 2. CD cell temperature was kept constant at 47 C. Error bars show a single standard deviation of recorded noise values over a period of one hour.

Effect of Variation of CD Cell and Suppressor Temperature Table 2 and Figure 3 show the effect on total conductivity signal noise of varying both the CD cell and suppressor temperature simultaneously. The CD cell was kept a constant +7 C warmer than the suppressor during the course of this experiment. As expected, changes in the suppressor temperature overwhelmed the positive impact of varying the CD cell temperature, thus an increase in suppressor and CD cell temperature led to an increase in recorded noise on the signal. The data in Table 2 reveal that raising the suppressor temperature in the 15 25 C range has a modest impact on noise, effectively adding 39% more noise to the signal; less than the impact of raising the temperature on the suppressor alone. However, raising the temperature above 25 C has a deleterious effect on noise, effectively adding 204% at 35 C and 393% at 40 C. Supp. Temp ( C) Signal Noise (µs) % Increase 15 0.363 20 0.427 18% 25 0.504 39% 30 0.615 70% 35 1.102 204% 40 1.789 393% Table 2. Conductivity signal noise as a function of suppressor temperature. CD cell temperature was varied with a constant +7 C difference to the suppressor temperature. % Increase values are based on the 15 C baseline. 2.5000 2.0000 Noise as a function of CD Cell and 1.5000 1.0000 0.5000 10 15 20 25 30 35 40 45 Figure 3. CD cell temperature was varied with a constant +7 C difference to the suppressor temperature. Error bars show a single standard deviation of recorded noise values over a period of one hour.

Table 3 and Figure 4 show the effect of varying both the CD cell and suppressor temperature simultaneously on peak height and calculated signal to noise ratio. At each temperature, 15 µl injections of 10 ppm sulfate were made and the height of the peak was taken as the signal strength. As the temperature was lowered on the detector compartment and the detector cell, the peak height (signal) simultaneously increased while the noise on the signal decreased. Thus the overall signal-to-noise ratio is improved by a factor of 4.5 over the temperature range of 40 C to 20 C. Conclusion This work conclusively demonstrates the benefits of active cooling of an electrolytic suppressor. Minimizing the operating temperature of the suppressor maximizes the sensitivity of the system while simultaneously reducing the variability in noise, leading to a more stable response. Ideally, temperatures of 15 C should be employed for maximum performance. Thus, an actively cooled, thermostatted compartment is critical for maximizing signal sensitivity. Supp. Temp ( C) Peak Height S/N 8000 7000 6000 5000 4000 3000 2000 20 2.9900 6997 22 2.9867 6710 25 2.9333 5821 30 2.8567 4643 35 2.8533 2590 40 2.8100 1571 Table 3. Sulfate standard peak height and calculated signal-to-noise ratio as a function of suppressor temperature. CD cell temperature was varied with a constant +7 C difference to the suppressor temperature. To determine peak height, a 15 µl injection of 10 ppm sulfate standard was injected. S/N as a Function of CD Cell and 1000 0 15 20 25 30 35 40 45 Figure 4. CD cell temperature was varied with a constant +7 C difference to the suppressor temperature. To determine signal strength, a 15 µl injection of 10 ppm sulfate standard was injected. Find out more at thermofisher.com/chromatography For Research Use Only. Not for use in diagnostic procedures. 2016 Thermo Fisher Scientific Inc. All rights reserved. All trademarks are the property of Thermo Fisher Scientific and its subsidiaries unless otherwise specified. TN72105-EN 0716S