CORROSION BEHAVIOR OF SELECTED HVOF THERMALLY SPRAYED COATINGS IN AGGRESSIVE ENVIRONMENTS

Similar documents
POTENTIODYNAMIC EVALUATION OF CORROSION RESISTANT COATINGS

COMPARISON OF ABRASIVE WEAR RESISTANCE BETWEEN HVOF THERMALLY SPRAYED ALLOY-BASED AND CERMET COATINGS

LASER SUFRACE REMELTING OF HVOF SPRAYED Co-Cr-W COATING

INFLUENCE OF HVOF SPRAYED COATINGS ON FATIGUE PROPERTIES OF COATING- SUBSTRATE SYSTEM

CORROSION PROPERTIES OF CERMET COATINGS SPRAYED BY HIGH-VELOCITY OXYGEN-FUEL. Dragos UŢU, Iosif HULKA, Viorel-Aurel ŞERBAN, Hannelore FILIPESCU

Microstructural Studies of Thermal Spray Coating

Thermal Spray Coatings in Severe Service Elaine Motyka 3/2/2017

Effect of Feed Rate and Impact Angle on the Erosive Wear of High Velocity Oxy-fuel Sprayed Coating Under High Temperature Conditions

THERMALLY SPRAYED COATINGS FOR RAILWAY APPLICATIONS

Applications. - APS coatings -

Available online at Fatigue G.S.Junior, H.J.C. Voorwald, L. F. S. Vieira, M. O. H. Cioffi, R.G.Bonora

Available online at Fatigue Fatigue in AISI 4340 steel thermal spray coating by HVOF for aeronautic application

THE STRUCTURE AND MECHANICAL PROPERTIES OF NiCrBSi COATINGS PREPARED BY LASER BEAM CLADDING

POSSIBILITIES OF STAINLESS STEEL LASER MARKING. Michal ŠVANTNER, Martin KUČERA, Šárka HOUDKOVÁ

Research Article Hot Corrosion Behaviour of Detonation Gun Sprayed Stellite-6 and Stellite-21 Coating on Boiler Steel SAE 431 at 900 C

Available online at ScienceDirect. Procedia Engineering 114 (2015 )

AL 29-4C AL 29-4C. Technical Data Sheet. Stainless Steel: Superferritic INTRODUCTION (UNS S44735)

INFLUENCE OF HEAT TREATMENT PARAMETERS, TEMPERATURE AND TIME, ON WEAR AND MICROHARDNESS OF NICRBSI FLAME SPRAYED COATINGS APPLIED ON CK45 SUBSTRATES

Microstructure and properties of NiCrBSiC overlay coatings deposited by the plasma scanning process

POSSIBILITIES OF UTILIZATION HIGH VELOCITY OXYGEN FUEL (HVOF) COATINGS IN CONDITIONS OF THERMAL CYCLIC LOADING

Laser assisted Cold Spray

THE INFLUENCE OF ANODISING PARAMETERS ON THE CORROSION PERFORMANCE OF ANODISED COATINGS ON MAGNESIUM ALLOY AZ91D

Fine-Tune Your Knowledge On The Metallizing Process

HVOF spray solutions. Phone: Fax:

Impact Fatigue Failure Investigation of HVOF Coatings

ABRADABLE THERMAL SPRAY COATINGS

POWPOWEER GENR ERATION

Experimental O 3. Results and discussion

Estimation of Dilution and Carbon Content of Laser Cladding on Stellite 6 Coatings Deposited on an AISI 316L Stainless Steel Substrate

Examination of tribological properties of oxide-polymer and carbide-polymer coatings formed by flame, plasma and HVOF spray processes

The Many Facets and Complexities of 316L and the Effect on Properties

GTV SPRAY POWDER CATALOGUE. according to DIN EN 1274

Prevention Strategies Design and Coatings

Material Product Data Sheet Cobalt Chromium (Nickel) Tungsten Carbon Alloy Powders

Methods of Corrosion Control. Corrosion Control or Corrosion Management?

Surface Coating of Tungsten Carbide by Electric Exploding of Contact

AN INVESTIGATION OF THE THERMAL SHOCK BEHAVIOR OF THERMAL BARRIER COATINGS

AUTOMOTIVE APPLICATIONS. Testing Instructions

To Study High Temperature Erosion-Corrosion of Detonation Gun Sprayed Al 2 O 3 Coated and Uncoated T-91 Boiler steel in Actual Environment of Boiler

MECHANICAL COMPATIBILITY OF TI COATINGS DEPOSITED BY HVOF THERMAL SPRAYING

IMPROVING WEAR BEHAVIOR OF GREY CAST IRON BY WC 12CO AND STELLITE-6 COATINGS

Cladding with High Power Diode Lasers

CHAPTER 2 - OBJECTIVES

COAXIAL LASER CLADDING OF STELLITE: ANYLYSIS OF PROCESS PARAMETERS. Marek VOSTŘÁK, Matěj HRUŠKA, Šárka HOUDKOVÁ, Eva SMAZALOVÁ

Hot Dip Galvanizing for Steel Corrosion Projection (fabricated steel items) By Mike Ainsley International Zinc Association (IZA)

DURABILITY OF BASALT FIBERS IN CONCRETE MEDIUM

CHARACTERIZATION OF WC-Co THERMAL SPRAY COATINGS BASED ON THE COMPOSITE POWDERS

Alternative Methods of Yttria Deposition For Semiconductor Applications. Rajan Bamola Paul Robinson

Thermal Surfacing Powder choice with ease

SEASTROM Manufacturing Co., Inc Seastrom Street Twin Falls, Idaho Fax (208)

SCREW & BARREL METALLURGY & SERVICE LIFE. Mrunal Sanghvi Regional Sales Manager Nordson Xaloy Asia (Thailand) Ltd.

A CORROSION MANAGEMENT AND APPLICATIONS ENGINEERING MAGAZINE FROM OUTOKUMPU 3-4/2013. The two phased optimization of duplex stainless steel

LONG TERM THERMAL EXPOSURE OF HAYNES 282 ALLOY

Extending Valve Life: The Art of Heat Treating and Ceramic Coatings

Cold Spray Coatings of Al Alloys for Corrosion Resistance

Ultra High Barrier Coatings by PECVD

Effect of Heat Treatment on the Corrosion Behaviour of GTM- SU-718 Superalloy in NaCl, HCl and H 2 SO 4 environments

REFINERY AND FCCU APPLICATIONS

voestalpine Additive Manufacturing Center Singapore Pte Ltd

High Temperature Oxidation Behaviour of Low Carbon Steel and Austenitic Stainless Steel

EXPERIMENTAL STUDIES ON CERMET COATING OF PISTON RING OF SINGLE CYLINDER DIESEL ENGINE

Characterization of Coatings on Grey Cast Iron Fabricated by Hot-dipping in Pure Al, AlSi11 and AlTi5 Alloys

This document is a preview generated by EVS

Thermal Spraying. OSAKA FUJI Corporation

High Temperature Corrosion Behavior of DS GTD-111 in Oxidizing and Sulfidizing Environments

Investigations on corrosion protective layers in waste incineration plants

Effects of the High Temperature Annealing on Structure of the High Velocity Oxygen Fuel Deposited WC-Co Coatings

Microstructure and Properties of MoB/CoCr Cermet Coatings Fabricated by LPPS

Materials Science and Engineering Department, University of Pittsburgh, Pittsburgh, PA, 15261

in Materials for High Performance Applications. The University of Birmingham, England, U.K., B15 2TT.

Heat treatment and effects of Cr and Ni in low alloy steel

United Surface Technologies

Solutions Flash Automotive applications benefit from cost-effective, high chromium Amdry Braze Alloys. SF October 2014

Electrodeposited Inconel and Stellite like Coatings for Improved Corrosion Resistance in Biocombustors

VDM Alloy 80 A Nicrofer 7520 Ti

Tubes Using Thermal Sprayed Coatings. Y. Sochi, M.Tanabe, A. Takeya, Surface Treatment Division, Dai-Ichi High Frequency Co. Ltd, Kawasaki, Japan

Galvanic corrosion evaluation of 6061 aluminum coupled to CVD coated stainless steel Elizabeth Sikora and Barbara Shaw 6/9/2016

INTRODUCTION TO THE HIGH-TEMPERATURE OXIDATION OF METALS

Microstructural Characterization of Aluminum Powder Liquid Coating on IN 738 Superalloy

Transactions on Engineering Sciences vol 8, 1995 WIT Press, ISSN

Functionally Graded Thermal Barrier Composite Coatings Formed by Gas Tunnel Type Plasma Spraying

Enhancing Wear Resistance of Grey Cast Iron Using Al 2 O 3-13TiO 2 and Ni20Cr Coatings

Coatings for exhaust heat recovery heat exchangers. N. Vourdas and V.N. Stathopoulos Technological Educational Institute of Sterea Ellada (TEISTE)

Application of Fly-ash Composite in Plasma Surface Engineering

Effect of thermal spray processes on microstructures and properties of Ni-20%Cr coatings

Product Test Report. PTR-3074 Swagelok Company. Rev. B Solon Road January 2015 Solon, Ohio U.S.A. Page 1 of 5

EFFECTS OF CURRENT DENSITY ON SIZE AND SURFACE MORPHOLOGY OF HIGH SPEED DIRECT NANO-CRYSTALLINE NICKEL PLATING ON TITANIUM SURFACE

Durability Testing of Ceramic Coatings for Indirect Resistance Heat Treating in Vehicle Lightweighting Applications

Powder Solutions Catalog

Heat and corrosion resistant alloys for chemical processing systems

Arch. Metall. Mater. 62 (2017), 1,

Study on HVOF spraying replacement of EHC repairing technique

Corrosion in biomass-fired installations

THE EFFECT OF SOL-GEL TECHNIQUE ON THE ALUMINIUM SiCp COMPOSITE

Effects of Seawater (Salt Water) to Aisi 304 Mechanical Properties

Anticorrosive Coatings

Direct nano-crystalline Ni plating on titanium surfaces

THERMAL FATIGUE RESISTANCE OF ALLOY 718 FOR ALUMINUM DIE CASTING DIES

Transcription:

CORROSION BEHAVIOR OF SELECTED HVOF THERMALLY SPRAYED COATINGS IN AGGRESSIVE ENVIRONMENTS Zdeněk ČESÁNEK, Eva SMAZALOVÁ, Jan SCHUBERT, Šárka HOUDKOVÁ, Michaela PRANTNEROVÁ VZÚ Plzeň s.r.o., Tylova 46, 301 00 Plzeň, Czech Republic, cesanek@vzuplzen.cz Abstract Corrosion resistant coatings must exhibit high density (low porosity), good adhesion to the substrate and of course low penetration of oxides. This paper deals with corrosion resistance comparison of six corrosion resistant coatings, which are frequently used in power plants. The comparison of following coatings is described: two cermet coatings Cr3C2-NiCr and Cr3C2-CoNiCrAlY, one experimental coating TiMoCN-Ni, and three alloy based coatings CoCrWC (Stellite 6), Hastelloy C-276 and NiCrBSi. Each of these six coatings was evaluated using immersion corrosion tests in two selected corrosive aggressive environments. Aqueous solution of 5% H2(SO)4 and artificial seawater were selected as corrosive aggressive environments. All coatings were deposited on W.Nr. 1.0553 carbon steel using thermal spraying technology HP/HVOF (High Pressure/High Velocity Oxygen Fuel). Carbon steel was used as the base material mainly to determine if the open porosity of evaluated coatings does not pose a problem in terms of components surface protection. Evaluation of coating corrosion attack was performed on the surface and in the cross-section of coatings. The evaluation was made before and after corrosion tests using optical and scanning electron microscopy. Furthermore, the amount of corrosion products was examined using mass weight loss/gain during the whole measurement. The corrosion behavior for all investigated coatings was very different. Cr3C2-NiCr cermet coating and alloy based Stellite 6 and Hastelloy C-276 exhibited the highest corrosion resistance in both selected aggressive environments. Keywords: HP / HVOF, corrosion, corrosion resistance, aggressive corrosive environments, porosity 1. INTRODUCTION The coatings formed by thermal spraying technology operate under different conditions (e.g. corrosive environments, different types of wear etc.) and also provide a wide range of functions (e.g. biocompatible coatings, thermal barriers etc.). Thermal spraying technology enables to create coatings based on metals, ceramics and polymers [1]. HP/HVOF belongs to the most effective thermal spraying technologies for deposition of coatings, and primarily also for deposition of cermets based coatings. This technology takes advantage of two factors. These factors are high-speed deposition and specific temperature for application of coatings with characteristic structure and properties [2]. Thermally sprayed coatings deposited by HP/HVOF have very low porosity and excellent adhesion to the substrate material, and therefore also good corrosion resistance. The thermal spraying technologies provide a great potential in terms of protection for devices and theirs components operating in aggressive environment [3]. However, open porosity can occurs by some coatings deposited using HP/HVOF, which poses a big problem for their subsequent use in aggressive corrosive environment. It is very important to create a coating that would not have open porosity and will be able to protect components in aggressive corrosive environments. To obtain such coating, the general knowledge about the thermal spraying technology, coating and application possibilities are necessary [4]. Corrosion resistance of Cr3C2-NiCr coating is highly dependent on the type of technology (HVOF vs. Plasma), construction of the spray equipment and on spraying parameters [5]. It is very important to be

aware of all factors that need to be considered to choose the coating properly. The basic factors are coating material, deposition technology and spray parameters. This paper evaluates six selected coatings that are being used in aggressive environments. The selected coatings are two cermet coatings Cr3C2-NiCr and Cr3C2-CoNiCrAlY, one experimental coating TiMoCN-Ni a three alloy based coatings CoCrWC (Stellite 6), NiCoCrMoWFe (Hastelloy C-276) and NiCrBSi. Cr3C2-NiCr cermet coating deposited by HP/HVOF is used in a wide range of industrial applications such are gas turbines, automotive industry, manufacturing techniques and many others. The coating should exhibit less than 1.5 % porosity. This very low porosity is crucial property in terms of corrosion protection of components. Furthermore, this coating is characterized by high resistance against high temperature corrosion due to the formation of nickel and chromium oxides, and nickel-chromium spinel [6]. In comparison with Cr3C2-NiCr, there are not so many technical publications of Cr3C2-CoNiCrAlY, but it has been proven that this coating provides excellent erosion and wears protection, even at temperatures approaching 1000 C. Furthermore, it was found out that the coating has better oxidation resistance than the Cr3C2-NiCr. It is used nowadays for furnaces and turbines components operating at high temperatures [7]. Experimental TiMoCN-Ni coating seems to be promising for the use in certain parts of devices operating under aggressive conditions. This coating is supplied by the Japanese company Fujimi, and due to the high content of Ti, it could be expected to be resistant in corrosive environment. Stellite 6 (CoCrWC) was chosen as an example of alloy based coatings. Stellite alloys are characterized by high hardness, toughness and typically exhibit excellent anti-corrosion properties. Due to the content of Co and Cr, the coating can be used for devices operating at high temperatures. These alloys behave at high temperatures as a diffusion barrier for the degradation media. This behavior is caused by the formation of chromium oxide on the borders of splats rich in Co, and by the formation of surface oxides, particularly cobalt and chromium together with cobalt-chromium and nickel-chromium spinels [8]. NiCrMo (Hastelloy) based coatings exhibit excellent corrosion protection. It is very important to consider that the corrosion resistance of coatings is connected with spaying parameters. It was found out that corrosion resistance is increasing with reduction if unmelted particles proportion in the coating. The boundaries between splats, which create the coating, are especially susceptible to the corrosion due to the presence of oxides [9]. NiCrBSi coating exhibits excellent corrosion resistance due to the selective oxidation occurring along splats boundaries rich in nickel and cobalt which form chromium and silicon oxides (Cr2O3 and SiO2). These oxides block passages in the pores, and thereby allow the coating to improve resistance to penetration and diffusion of corrosive media. Moreover, very low porosity and structure of flat splats in the coating also contributes to the development of resistance to high temperature corrosion at elevated temperatures [8]. In all these six described coatings were tested by immersion corrosion tests in two suitably selected corrosive aggressive environments. 2. EXPERIMENTAL PROCEDURE As it was already mentioned, five commercially available powders were used for sample preparation. These powders were Amperit 588.074 (Cr3C2-NiCr) with a particle size distribution suitable for HVOF (-45+15 mm), Amperit 594.074 (Cr3C2-25%CoNiCrAlY) with a particle size distribution suitable for HVOF (-45+15 mm), M- 484.33 (CoCrWC) with a particle size distribution suitable for HVOF (-53+20 mm), M-341.33 (Alloy-276) with a particle size distribution suitable for HVOF (-53+20 mm), M-771.33 (NiCrBSi) with a particle size distribution suitable for HVOF (-53+20 mm) and one experimental powder labeled T10 (TiMoCN-Ni). All coatings were deposited by HP/HVOF (High Pressure/High Velocity Oxygen Fuel) technology with JP- 5000 torch from the company TAFA Incorporated. Already optimized spray parameters were used for each

coating. Structural steel W.Nr. 1.0533 (DIN 11 523) of Ø25x5mm dimension was used as substrate material for proper verification of protective properties (the existence of open porosity) in corrosive aggressive environments. It was used as substrate material for all evaluated coatings. These samples were cold mounted using the EpoFix Struers set. Mounted samples were metallographically polished. Subsequently, the photos of microstructures on surface and in cross section of all evaluated coating were made before corrosion tests using optical and scanning electron microscopy. Capillary test was performed and showed the necessity to use sealing protection around the samples circumference and on their surfaces. Silicone sealant Lukopren S 8280th was used as suitable alternative for sealing treatment. Surface measurement (using light microscopy) of the area exposed to corrosive attack was made after the vulcanization (3mm/24h) of the sealant. All samples were afterwards three times measured on the scale with accuracy of 0.0001g. Reference sample was added to the evaluated samples into the corrosive environment to verify the accuracy of sample mass measurements after the first and the subsequent weighing during the corrosion testing. The first weighing of samples was performed after 24h. Samples were first washed in deionized water bath and subsequently by washing bottle before every weighing. After this procedure, the samples were placed in the box dryer to dry at 100 C for 3h. After 3 hours necessary for adequate drying, the samples were removed from the kiln and placed for 1h into Schleibler exicator. Finally, it was followed by weighing to determine weight loss or gain for each evaluated coating. The reference sample was always measured as first. The reference sample changed its weight with an acceptable tolerance of ±0.0005 g. All evaluated samples were measured three times. After the measurements, the samples were immersed back into the corrosive environment. Resulting microstructure evaluation using optical and scanning electron microscopy was performed on all samples after the corrosion testing was completed. Aqueous solution of 5% H2(SO)4 with 150ml volume was selected as aggressive corrosive environment. The second environment was artificial seawater of the same volume and with chemical composition summarized in Tab. 1. First corrosion tests were conducted at room temperature. Table 1 Chemical composition of artificial seawater Artificial seawater Salt Concentration [g/l] Salt Concentration [g/l] NaCl 24,54 NaHCO 3 0,2 MgCl 2x 6H 2O 11,1 KBr 0,1 Na 2SO 4 4,09 H 3BO 3 0,03 CaCl 2 1,16 SrCl 2 x H 2O 0,04 KCl 0,69 NaF 0,003 3. RESULTS AND DISCUSSION 3.1 Microstructure of coatings a) b) c) d) e) f) Fig. 1 SEM pictures of coatings in cross sections, from the left is Cr3C2-CoNiCrAlY, Cr3C2-NiCr, TiMoCN-Ti, Stellite 6, Hastelloy C-276, NiCrBSi before corrosion tests at 3000x magnification.

Different structures of all evaluated HVOF sprayed coatings can be seen in the photos in Fig. 1. Cr3C2- CoNiCrAlY and TiMoCN-Ni coatings have the highest porosity according to SEM photos. These coatings contain networks of pores and unmelted particles having influence on the corrosion protection properties of individual coatings. 3.2 Corrosion protection and durability of thermally sprayed coatings Corrosion resistance of coatings and surface protection using HP/HVOF sprayed coatings is strongly dependent on the appropriate spraying parameters for individual coating and on corrosive environment in which the coating works. For better clarity, the results of mass loss in 5% H2(SO)4 environment are divided into two graphs. Fig. 2b shows that NiCrBSi and TiMoCN-Ni coatings exhibited the lowest protection to the substrate and the lowest corrosion resistance in 5% H2(SO)4. On the contrary, Cr3C2-NiCr coating exhibited the smallest corrosion attack and the highest protection to the substrate in 5% H2(SO)44. The results in the graphs are with accuracy ±0.001g. Coatings corrosion behavior was different in artificial seawater in comparison with 5% H2(SO)4. TiMoCN-Ni exhibited the biggest corrosive attack and the lowest protection to the substrate in artificial seawater. Other coatings exhibited very similar behavior; see the diagram in Fig. 3. Based on the results below, the corrosion of all evaluated coatings was stronger in H2(SO)4 aggressive environment compared with artificial seawater. This difference in corrosion behavior increased with increasing time of exposure. However, if we consider only the aspect of the protection to the substrate material, the lowest protection in both aggressive environments exhibited Cr3C2-CoNiCrAlY due to very high porosity, see Fig. 1a. a) b) Fig. 2 Mass gains of coatings after immersion corrosion testing in 5% H2(SO)4 at room temperature Fig. 3 Mass gains of coatings after immersion corrosion testing in artificial seawater at room temperature The best corrosion protection to the substrate in 5% solution of H2(SO)4 out of the cermet coatings exhibited Cr3C2-NiCr. Fig. 4a shows the cross section of the coating before the test in 5% solution of H2(SO)4, and Fig. 4b shows the cross section of this coating after the immersion corrosion test. Cr3C2-CoNiCrAlY showed the worst corrosion protection out of all three evaluated cermet coatings. Fig. 4c shows the cross section of the coating before the test in 5% solution of H2(SO)4 and Fig. 4d shows the cross section of Cr3C2-CoNiCrAlY after the immersion corrosion test. The pictures show that the penetration of corrosive media to the substrate and the damaged adhesion between the coating and the substrate material were most likely caused by high open porosity of Cr3C2-CoNiCrAlY. Stellite 6 coating exhibited the best corrosion protection to the substrate in 5% solution of H2(SO)4 out of alloy coatings. Fig. 4e shows cross section of Stellite 6 before the test in a 5% solution of H2(SO)4, and Fig. 4f shows the cross section of Stellite 6 coating after immersion corrosion

testing. NiCrBSi exhibited the worst corrosion protection out of three evaluated alloy based coatings. Fig. 4g presents cross section of the coating prior to the test in 5% solution of H2(SO)4 and Fig. 4h shows cross section of NiCrBSi coating after immersion corrosion testing. The pictures indicate that there probably occurred reaction between NiCrBSi a 5% solution of H2(SO)4 and gradual dissolution of the coating without any attack on the substrate material. This statement is supported by the results of the weight gain measurement, see Fig. 2b. a) b) c) d) e) f) g) h) Fig. 4 Photos of evaluated coatings in cross section before and after corrosion testing in aqueous solution of 5 % H2(SO)4, where a) Cr3C2-NiCr coating before testing, b ) is Cr3C2-NiCr coating after corrosion testing, c ) Cr3C2-CoNiCrAlY coating before testing, d ) Cr3C2-CoNiCrAlY coating after corrosion tests, e ) Stellite 6 coating before testing, f ) Stellite 6 coating after corrosion tests, g ) NiCrBSi coating before testing, h ) NiCrBSi coating after corrosion tests. The best corrosion protection to the substrate in artificial seawater out of cermet coatings showed again Cr3C2-NiCr. Fig. 5a shows cross section of the coating before the test in artificial seawater and Fig. 5b shows the cross section after the immersion corrosion test. Cr3C2-CoNiCrAlY coating exhibited again the worst corrosion protection out of three evaluated cermet coatings. Fig. 5c shows cross section of the coating before the corrosion test in artificial seawater and in Fig. 5d shows cross section of Cr3C2-CoNiCrAlY coating after immersion corrosion test. The pictures apparently show that the penetration of corrosive media to the substrate and the damaged adhesion between the coating and the substrate material were most likely caused by high open porosity of Cr3C2-CoNiCrAlY. Fig. 5e also shows selective corrosion of this coating, but it could be just corrosion products of the substrate material washed up through the open porosity. a) b) c) d) e) f) g) h) i) j) Fig. 5 Photos of evaluated coatings in cross section before and after corrosion testing in artificial seawater, where a) Cr3C2-NiCr coating before testing, b ) is Cr3C2-NiCr coating after corrosion testing, c ) Cr3C2- CoNiCrAlY coating before testing, d ) Cr3C2-CoNiCrAlY coating after corrosion tests, e ) Stellite 6 coating before testing, f ) Stellite 6 coating after corrosion tests, g ) NiCrBSi coating before testing, h ) NiCrBSi coating after corrosion tests. The best corrosion protection to the substrate in artificial seawater out of alloy based coatings exhibited Hastelloy C-276. Fig. 5f shows cross section of Hastelloy C-276 coating before the test in artificial seawater

and Fig. 5g shows the cross section of Hastelloy C-276 coating after immersion corrosion testing. NiCrBSi coating exhibited the worst corrosion protection out of all three evaluated alloy based coatings. Fig. 5h shows cross section of the coating before the test in artificial seawater and Fig. 5i shows cross section of NiCrBSi coating after immersion corrosion testing. The photo Fig. 5j shows that selective corrosion probably occurred by this coating, but it could be just corrosion products of the substrate material washed up through the open porosity. 4. CONCLUSION 1. Based on the expectations, it was confirmed that alloy coatings generally exhibit better corrosion protection to the substrate than cermet coatings. This fact is probably connected with lower porosity in comparison with cermet coatings. 2. Cr3C2-NiCr coating showed the best behavior of all evaluated cermet coatings in aggressive environment of 5% H2(SO)4 solution, both in terms of corrosion protection to the substrate material and of coating resistance against corrosion attack. This coating exhibited the same results in corrosive environment of artificial seawater. Cr3C2-CoNiCrAlY showed the worst behavior in terms of substrate material corrosion protection in both corrosive environments. It was caused by high porosity of this coating. In my opinion, it is possible to reduce this high porosity by the choice of another spraying parameters 3. Stellite 6 exhibited the highest resistance in 5% solution of H2(SO)4 out of all alloy based coatings and Hastelloy C- 276 in artificial seawater. NiCrBSi exhibited the worst behavior in both environments. ACKNOWLEDGEMENTS This paper was prepared with support from grant No. TA02010486. LITERATURE [1] ENŽL, R. Vysokorychlostní nástřik povlaků na bázi karbidu wolframu, [Disertační práce], Plzeň ZČU, FAV, KFY, 2001. [2] DAVIS, J.R. Handbook of Thermal Spray Technology, ASM International, 2004. [3] DUCHEK, P., BLÁHOVÁ, O., DVOŘÁK, M., HOUDKOVÁ Š., KASLl, J., ENŽL, R. Korozní odolnost žárových nástřiků, Metal 2002. [4] FAUCHALS, P., VARDELLE, A., DUSSOUBS, B. Quo Vadis Thermal Spraying?, Journal of Thermal Spray Technology, 2001, 10,(1), s. 44-46. [5] GUILEMANY, J.M., FERNANDÉZ, J., DELGADO, J., BENEDETTI, A.V. Influence of Thermal Treatments in the Corrosion Behavior of HVOF Cr3C2-NiCr Coatings. Proceedings of the International Thermal Spray Conference, Thermal Spray 2001: New Surfaces for a new Millennium, Singapore (2001), s. 1165-1169. [6] SIDHU, T.S., PRAKASH, S., AGRAWAL R.D., Characterizations and Hot Corrosion Resistance of Cr3C2-NiCr Coating on Ni-base Super alloys in an Aggressive Environment, Journal of Thermal Spray Technology, vol. 15, (2006), PP 811-816. [7] Flame spray technologies BV, www.fst.nl, http://www.fst.nl/products/materials-and-supplies/powders, [ source obtained 24.2.2014] [8] SIDHU, T.S., PRAKASH, S., AGRAWAL R.D. A Comparative Study of Hot Corrosion Resistance of HVOF Sprayed NiCrBSi and Stellite-6 Coated Ni-Base Super alloy at 900 C, Materials Science & Engineering A, (2007), Elsevier, s. 210-218. [9] MOSKOWITZ, L.N. Applicationof HVOF Spraying to Solve Corrosion Problems in the Petroleum Industry, Journal of Thermal Spray Technlogy, (1993), Vol. 2,s. 21-29.