DISTRIBUTION TRANSFORMER SPECIFICATION #

Similar documents
CLARK PUBLIC UTILITIES TECHNICAL SPECIFICATIONS SINGLE-PHASE PADMOUNTED TRANSFORMERS

S. C. Electric Cooperative s Specification for a Single-Phase, Two Bushing Overhead Distribution Transformer (Revised 10/2013)

CONSOLIDATED EDISON COMPANY OF NEW YORK, INC. 4 IRVING PLACE NEW YORK, NY ORANGE & ROCKLAND UTILITIES 390 WEST ROUTE 59 SPRING VALLEY, NY 10977

B. Provide liquid-filled secondary substation transformers as indicated on drawings.

BUSWAY LOW VOLTAGE (POW-R-WAY III) SECTION SECTION 16466

Title: YALE OFFICE OF FACILITIES PROCEDURE MANUAL Chapter: 01 - Yale Design Standard Division: Electrical Standards

SECTION 16496A MTS MANUAL TRANSFER SWITCH (MANUAL CONTROL ONLY) Note to Spec Writer: { } Denotes EATON Feature reference number

Welcome to Douglas County PUD

UFGS (August 2010) UNIFIED FACILITIES GUIDE SPECIFICATIONS

Underground Residential Distribution (Specifications for Installation) PES March 2008 Spec 11

Diffused Aeration Piping Equipment

SECTION GROUNDING AND BONDING FOR ELECTRONIC SAFETY AND SECURITY

Standard of Practice - Campus Electrical Distribution System

15 kv EPR Insulated, Jacketed, URD Cable

SECTION MEDIUM VOLTAGE TRANSFORMERS

NEUTRAL GROUNDING TRANSFORMERS INSTALLATION AND MAINTENANCE INSTRUCTIONS

The following document can be provided to an Engineer, Contractor, or Owner to allow them to

OPERATING PROCEDURE NO. 310

SECTION SUBSTATION BUS ASSEMBLIES ERGLE SUBSTATION

SECTION PACKAGE BOOSTER PUMP STATIONS

SUGGESTED SPECIFICATIONS Pump Frames through 64132

DOWNTOWN UNDERGROUND NETWORK SECONDARY SERVICES GUIDELINES

NEC 2017 Code Changes Chapter 1 - General

2003 International Residential Code ELECTRICAL PROVISIONS ONLY October 2005 EDITORIAL CHANGES SEVENTH PRINTING

SECTION SLUDGE HOLDING TANK DECANTER PUMP

INVITATION TO BID B I D F O R M. Please submit bid on or before 2:15 pm 101 North Halagueno Street June 6, 2013, at the office of the

Customer Owned Meter Enclosures for Self-Contained Watthour Meters

A. This Section includes the following types of dry-type transformers rated 600 V and less, with capacities up to 1000 kva:

SECTION (Master Template Final-05) ELECTRICAL BOXES. A. Provide boxes for electrical equipment and wiring devices as follows:

*** Supercedes: BECO E and COM , , & ***

SECTION HIGH EFFICIENCY DISTRIBUTION TRANSFORMERS

SST-II HYDRAULIC BI-FOLD SPECIFICATIONS

SECTION HEAT TRACING FOR PLUMBING PIPING

DESIGN GUIDELINES WIRING AND CONDUITS PAGE 1 of 7

6. SECONDARY SERVICES (under 600 volts) 6.1 AVAILABILITY For the electrical characteristics of available secondary services see Section 3.4.

NORTHWESTERN UNIVERSITY PROJECT NAME JOB # ISSUED: 03/29/2017

HUP. Performance Data. Wholesale Products Page: Section: Performance Data Dated: January RPM: 1550 Discharge: 1" Solids: 1/8" GPM: TDH:

SECTION AUTOMATIC TRANSFER SWITCH

660 Volts 630 & 800AMP

SK75/100. Performance Data TOTAL HEAD IN FEET HEAD-METERS 6 SK100 SK Liters/Second Capacity-U.S. G.P.M.

SECTION 1101 TRAFFIC SIGNALS AND APPURTENANCES END OF SECTION

SECTION INFLUENT EQUALIZATION TANK PUMPS

4CS12 4CS-1/2 4X1-7/8D Handybox. Features. Dimensions and Weight. Long Description. Catalog Number

OVERHEAD SERVICES - RESIDENTIAL & GENERAL SERVICE. See Chapter 3, Section 3.01 for more information about point of entrance (POE).

SECTION 07 TECHNICAL SPECIFICATIONS 11KV OUTDOOR TYPE SINGLE PHASE METAL OXIDE (ZNO) GAPLESS LIGHTNING ARRESTER (LA)

B. Polyethylene samples shall be submitted for Owner approval of color and quality.

ITEM L-119 AIRPORT OBSTRUCTION LIGHTS DESCRIPTION

G2D Series Performance Data Discharge: 1-1/4 Solids: 1/4. Wholesale Products Page: JP10075SSD-1 Section: Performance Data Dated: January, 2011

HYDROMATIC W/D/V-A1 SUBMERSIBLE SUMP/EFFLUENT

SECTION MECHANICAL EQUIPMENT - GENERAL REQUIREMENTS

SECTION ALUMINUM GATES

SERVICE ENTRANCES. OPPD S Electrical Service Designer (ESD) shall designate the Point Of Entrance.

(Condensed from National Electric Code)

UNIVERSITY OF WASHINGTON Facilities Services Design Guide. Electrical. Medium Voltage Switchgear. Basis of Design.

SECTION ROLLER GATES

SECTION ROOF SPECIALTIES

UNDERGROUND SERVICES SECONDARY

A. All materials shall be tested and listed by an OSHA approved Nationally Recognized Testing Laboratory (NRTL).

MIL-L-26764B 4 March 1970 SUPERSEDING MIL-L-26764(ASG) 12 December 1963 MILITARY SPECIFICATION

This section includes materials and installation of ductile-iron pipe and fittings for potable and recycled water systems.

HIGH MAST CAMERA POLE ASSEMBLY GENERAL

5. AMCA 301 Method of Publishing Sound Ratings for Air Moving Devices. 6. AMCA 500 Test Methods for Louver, Dampers, and Shutters

SUGGESTED SPECIFICATIONS

SECTION INSULATED WIRE AND CABLE


SECTION GROUNDING AND BONDING

SECTION LUMINAIRES AND ACCESSORIES

A. Product Data shall be provided for each type of product indicated.

Unit Substation Transformer Construction Checklist (under 500 kva)

2/2 % ) Direct Acting Subminiature Solenoid Valves. 1/8" and 1/4" NPT. Features. Construction. Electrical

SECTION LAGUNA SERIES TOP HUNG SLIDING DOOR SYSTEM

CONSOLIDATED EDISON COMPANY OF NEW YORK, INC Van Dam Street Long Island City, NY ELECTRIC METER SHOP DEPARTMENT

Power Electronics, Inc. Packaged Equipment Center Standard Construction and Design Features

Electric Service Standards

SPECIFICATIONS - DETAILED PROVISIONS Section Stainless Steel Sluice Gates C O N T E N T S

METERING INSTALLATION


SECTION CRL50 AND CRL51 HEAVY GLASS TOP HUNG SLIDING DOOR SYSTEMS

NORTH HARRIS COUNTY REGIONAL WATER AUTHORITY PIPE HANGERS, Section PIPE HANGERS, SUPPORTS, AND RESTRAINTS

1. Telecommunications mounting elements. 2. Backboards. 3. Telecommunications equipment racks and cabinets. 4. Grounding.

ITEM 686 TRAFFIC SIGNAL POLE ASSEMBLIES (STEEL)

SECTION HIGH DENSITY POLYETHYLENE PIPE AND FITTINGS (PRESSURE PIPE)

8.1.2 Under no circumstances shall a service entrance be left unmetered. Notify the Company if an unmetered service is encountered.

W-P-115C March 14, 1990 SUPERSEDING W-P-115B June 8, 1984 FEDERAL SPECIFICATION PANEL, POWER DISTRIBUTION

SECTION WIRE AND CABLE Raceways and Conduit Motor Power and Control Wiring.

A. Access doors and frames are part of an access door and frame allowance.

This guide can be used to prepare a specification for incorporating free standing jib cranes into a competitively bid construction project.

American Metal Specialties, Inc.

CHAPTER 11 CONDUITS AND FITTINGS

HYDROMATIC SKV50 SEWAGE EJECTOR PERFORMANCE DATA SKV50. Wholesale Products Page: RPM: 1650 Discharge: 2 Solids: 2.

SECTION 716 SIGN MATERIALS SCOPE

ARRANGEMENT AND WORKING OF MULTIPORT FLOW SELECTOR VALVE IN PRODUCTION MANIFOLD:

NUCLEAR POWER CORPORATION OF INDIA LTD. (A GOVT. OF INDIA ENTERPRISE) SPECIFICATION NO.PB-E-542/REV. No.0

ANSI/ ASME HST Performance Standard For Overhead Electric Wire Rope Hoists

SECTION CHAIN-LINK FENCES AND GATES 02821/1

Installation Instructions

SECTION ROOF ACCESSORIES

roduct Scope: Substation

SECTION SLUICE GATES

SPECIAL SPECIFICATION 1663 Fiber Optic Cable

Transcription:

DISTRIBUTION TRANSFORMER SPECIFICATION #1212.03 15kV Single Phase Submersible Transformer Stainless Steel 12/2/2011 Page 1 of 8

1. SCOPE This specification covers single-phase submersible transformers for use on a the District s 12470 GrdY/7200 Volt 60 Hertz,. underground distribution system and appropriate for 3 banking The transformers are intended for installation below ground in vaults and for operation on a primary loop or radial system. The transformers shall be suitable for continuous submersion. The transformers will be connected phase-to-neutral in both single-phase or three-phase applications. The low voltage windings will be connected closed delta or closed Y. 2. STANDARDS All material and equipment furnished under these specifications shall conform to the latest applicable approved standards of the IEEE, ANSI, and NEMA, except as otherwise specified herein. 3. RATINGS 3.1. All ratings shall be for 60 Hertz alternating current, oil immersed, self-cooled transformers capable of continuous operation at rated kva without exceeding either a 55 C average temperature rise or a 70 C hot spot temperature rise. 3.2. The electrical characteristics of the completely assembled high and low voltage terminals shall be 7200/12470Y, and 120/240 (4 low-voltage bushings). 3.3. The basic impulse level (BIL) shall be 95 kv. 4. RADIAL FEED Transformers will be suitable for radial feed. 5. CONSTRUCTION 5.1. Construction of the units shall be such that they can be lifted and lowered into place in a suitably designed and constructed enclosure having a minimum diameter of 36 inches. To allow for cabling space and proper airflow for cooling, the transformers covered by this standard shall not have overall diameters in excess of 30 inches for sizes 100 kva and smaller, in excess of 33 inches for 167 kva or 38 inches for 250kva and larger. 5.2. The transformer tank, cover, and all external appurtenances shall be of corrosion-resistant 304L stainless steel. This includes welds, plugs (may be brass), nameplates, etc. 5.3. A protective (paint) coating of semi-gloss sky gray similar in color to ANSI Standard no. 70 shall be applied that is at least 3 mils thick... 5.4. Welds shall be smooth and shall not cut workers hand or gloves. The tank and cover shall be capable of withstanding a full vacuum. 5.5. Tank Cover 5.5.1. The tank cover shall be welded to the tank. No handhole shall be installed in the cover. 5.5.2. The threads between the oil fill plug and the boss on the tank shall be sealed with a liquid pipe thread compound. Teflon tape is undesirable as it leaves shreds floating in the oil. Suggested products are Rectorseal, liquid Teflon, or similar sealants. If a fill plug is not provided, a 1/4-inch NPT boss with a brass plug shall be provided for the purpose of pressure testing. 12/2/2011 Page 2 of 8

5.6. Tank Ground The tank grounding connection shall be per ANSI C57.12.20, Section 6.5.4 except: 5.6.1. The connection shall consist of a stainless steel boss or pad and shall be equipped with a solder less tinned copper-alloy connector that will accommodate #8 solid through #2 AWG stranded copper wire. The clamping eye bolt threads shall be 3/8-16NC. 5.6.2. The tapped hole in the boss or pad and the stud of the connector shall be 1/2- inch-13nc, Class 2 fit. The tapped hole shall be coated with an oxide-inhibiting compound before installation of the connector. 5.6.3. This connection shall be plainly labeled G. 5.6.4. Extra tank ground bosses shall be protected with oxide-inhibiting compound and a plastic flanged cup pressed into the threads (aluminum cups are not acceptable). 5.7. Base bars of 401 Stainless Steel shall be provided on the transformer tank to protect the bottom of the tank while in transit and when installed in the underground enclosure. Minimum bar height is 1.00 inch. 5.8. The lifting provisions shall be permanently attached and arranged on the tank to provide a distributive balanced lift in a vertical direction for the completely assembled transformer. They shall be designed to provide a safety factor of 5. 6. TRANSFORMER TAPS No transformer taps are required. 7. CONNECTORS AND TERMINALS 7.1. Primary Bushing 7.1.1. Transformers shall come equipped with two high voltage bushing wells (H1 and H2), and corresponding load break inserts for dead front application. The bushing wells shall be welded to the transformer cover, 200-amp rated, separable, and rated for primary switching per IEEE 386. Gasketed bushing wells are not acceptable. The bushing well shall have a cover or cap to prevent the entrance of moisture or dirt during shipping or storage. The cap shall be secured in a manner that prevents its loss during shipment or temporary storage. 7.1.2. The bushings shall conform to IEEE C57.12.23. 7.1.3. The load-break bushing inserts shall be Cooper Power Systems (Catalog No. 2604797B01M) or Elastimold (Catalog No. 1601A4). 7.1.4. One parking stand shall be welded in Segment 3 as shown in the latest IEEE C57.12.23. 7.2. Secondary Terminals or Leads 7.2.1. Four low-voltage cable leads (eight for 167 kva, 250 kva, and 333 kva) extending 36 inches above the top of the cover shall be provided and arranged for vertical takeoff. The secondary neutral shall be floating and extended for external grounding. 7.2.2. The cable insulation and sizes shall be in accordance with IEEE C57.12.23. The 12/2/2011 Page 3 of 8

ends of the cable leads shall be water sealed. The secondary bushing shall be plainly labeled X1, X3, X2, or X4, appropriately. 7.2.3. The cable ends shall be sealed with a heat or cold shrink cap and can not be removed without cutting the cap. 7.3. Ground connections shall be suitably sized for the short-circuit rating of the transformer as defined in the latest IEEE C57.12.00 8. FUSING 8.1. Transformer H1 bushing leads shall be provided with Cooper Power Systems Bay-O-Net, dual sensing, load break, cover-mounted, externally removable links in series with underoil, internally mounted 15 kv partial range current limiting fuses (CLF). The partial range fuse shall be manufactured by Cooper Power Systems (Type Multi-Coil ELSP). 8.2. The partial range current limiting fuses shall be placed in series with the Bay-O-Net fuse holder and be mounted internally under oil. Partial range current limiting fuses shall have a nominal voltage rating of 15 kv. 8.3. Fuses shall meet the Districts current fusing specifications which are shown below: Single Phase KVA Bay-O-Net Fuse (Dual Sensing) Continuous Ampere Rating ELSP Rating (A) Current Limiting (ELSP Backup) 25 4000358C05 15 CBUC15030C100 30 37.5 4000358C08 15 CBUC15050C100 50 50 4000358C08 15 CBUC15065C100 65 75 4000358C10 25 CBUC15100C100 100 100 4000358C10 25 CBUC15100C100 100 167 4000358C12 65 CBUC15165D100 165 250 4000358C14 65 CBUC15165D100* 330 333 4000358C14 65 CBUC15165D100* 330 *indicates parallel fusing 9. TRANSFORMER OIL Transformers shall be insulated with new (unused) mineral oil. The oil shall meet the requirements of ANSI C57.12.00, Article 6.6.1 (1), ANSI C57.106 and ASTM 3487 Type II. The transformer nameplate shall indicate that the PCB content of said transformer is less than 1 PPM or at time of manufacture gas chromatographic analysis certified non-detectable PCB. The oil shall be inhibited mineral oil containing 0.2 % by weight DBPC. 10. NOISE Transformer sound levels shall not exceed the values specified in the latest revision of NEMA Publication TR 1-0.11. 11. PAINT FINISH NONE REQUIRED 12. NAMEPLATES 12.1. A stainless steel diagrammatic nameplate shall be affixed to the tank cover (or any nameplate extension bracket) using stainless steel fasteners. The nameplate shall state all 12/2/2011 Page 4 of 8

information per ANSI C57.12.00, nameplate A, except the nameplate shall include the following: 12.1.1. A manufacturer s serial number barcode shall be etched into the nameplate using a character size of 128A. The barcode shall be a maximum ½ high and 2½ wide. The manufacturer s identification characters shall not be included in the barcode. 12.1.2. The date (month/year) of manufacture. Serial numbers that include a date code will not suffice. 12.1.3. The statement Contains less than one ppm PCB at time of manufacture. Separate NON PCB stickers, labels, or extra nameplates will not suffice. 12.1.4. The gallons of oil. 12.1.5. The weight of the transformer for all sizes including 25 kva. 12.1.6. The manufacturer and catalog number for the primary fuses and fuse holder. 12.1.7. Items a., c., d., and e., above, may be either on the nameplate or a separate stainless steel nameplate. Stenciling or other labels will not be acceptable. 13. INSPECTION The purchaser shall at any reasonable time be permitted to have a representative visit the Contractor s factory for the purpose of witnessing manufacture of the transformers to ascertain if the material and process used in the manufacturing conform to the Specifications. 14. TESTS 14.1. Each transformer shall receive complete tests at the factory in accordance with latest ANSI Standards. At the option of the District, transformers may be tested for acceptance upon receipt. 14.2. Test Tags. Each transformer shall have a durable, weatherproof tag firmly attached, reading: This transformer has been tested at rated line voltage and has successfully passed all applicable tests specified by ANSI and NEMA. The tag shall show the transformer serial number, the date, and name of the person who made the test. (State of Washington, Safety Statutes, Section 19.29.010, Rule 5). NOTE: Slight variations in wording will be acceptable with prior approval, and computer-tested units need not include a person s name. 15. EVALUATION AND AWARD 15.1. For the purpose of evaluating bids in addition to the evaluation criteria set forth in Section B, Evaluation of Bids, consideration will be given to the following three items. Product Quality Loss Evaluation 12/2/2011 Page 5 of 8

Adherence to Specifications. 15.2. Transformers will be evaluated on losses using the following criteria. 15.2.1. Losses furnished for evaluation shall be guaranteed maximum losses for each transformer bid. 15.2.2. No load losses (NLL) shall be in watts, at 20 C in accordance with ANSI C57.12.00. 15.2.3. Full-load losses (FLL) shall be in watts, measured at rated nameplate load at 85 C in accordance with ANSI C57.12.00. 15.2.4. Losses will be evaluated at the following values: 15.2.5. $4.07 per watt for no-load losses 15.2.6. $1.79 per watt for full-load losses 15.2.7. The manufacturer shall furnish with each transformer a certified test report of the no-load and full-load losses. The test report shall be submitted with the Contractor s invoice. 15.3. Transformer evaluated prices will be determined as follows: Evaluated $ = {$4.07 x NLL} + {$1.79 x FLL]} + {Base Price x (Transformer Evaluation Factor)} 16. DATA TO BE SUBMITTED WITH BID Each bidder shall submit with his proposal the data listed below. He shall submit a description of any changes, additions or exceptions to the specification he proposes, together with reasons for the departure. Product evaluation and conformance to specification will be determined on the basis of information submitted. The drawings and data furnished must be in sufficient detail and clarity to enable making a complete and positive check with the technical provisions of the specification. 16.1. Outline drawings with overall dimensions. 16.2. Details of the primary and secondary bushings. Manufacturers name and catalog numbers will suffice for primary bushings if no exceptions are requested. Secondary bushing details shall include (1) materials (cable or spade), (2) finish, such as plating, (3) dimensions (cable size + length or spade size and thickness). 16.3. Maximum core losses (no load) at 20 C and load losses (windings) at full load at 85 C. If other temperatures are used, provide an explanation and correction factor. 16.4. That the transformer is a 55 C rise design. 16.5. Impedance of windings at rated load expressed in percent of rated voltage. 16.6. Information concerning details of construction, tank materials and tank finish. State grade of stainless steel and total thickness of paint. 16.7. Make and specification of oil. Uninhibited oil is unacceptable. 16.8. Complete primary fuse data including fuses specified for each size of transformer. Include manufacturer and catalog number of fuse and holder. 16.9. State all electrical tests given transformers at the factory and whether these tests apply to 12/2/2011 Page 6 of 8

all units or only sample units. 16.10. Total weight of completely assembled transformer, including oil. 16.11. A drawing of the transformer nameplate. Complete fuse data shall be shown on the nameplate: type, size, catalog number and manufacturer. 17. WORKSMANSHIP, MATERIAL, AND FINISH All workmanship and material used on the equipment shall be first class, the best of their respective kinds and shall be in full accordance with the most modern manufacturing practices for distribution transformers. 18. PAYMENT The contractors invoice must include itemized list of size (kva) voltage and serial numbers of units sent, along with certified test reports before invoice will be paid. An order is not complete until certified test reports on each transformer shipped is in the District s possession. 19. DATA TO BE FURNISHED BY THE SUCCESSFUL BIDDER The successful bidder shall supply: 19.1. Three copies of outline dimensions of the transformer with accessories. 19.2. Three copies of the transformer nameplate. 19.3. Three copies of an instruction book covering installation, operation, and maintenance of the equipment furnished. 19.4. One copy of certified test data for each transformer supplied. The test data shall contain the minimum following information: 20. DELIVERY (1) core loss, (2) load loss, (3) exciting current at rated voltage, (4) insulation tests. 20.1. The transformers shall be shipped F.O.B. destination to 1150 Hawley Street, Wenatchee, WA, 98801. The delivery will be accepted Monday through Friday between the hours of 9:00 AM and 2:00 PM. No delivery of transformers will be accepted on holidays. Please call Hawley Street Warehouse Foreman at (509) 663-8121, Ext. 4730, 24 hours prior to delivery. No transformers will be received on national holidays. 20.2. Transformers shall be shipped completely assembled in an enclosed van and filled with the proper amount of transformer oil. 20.3. Transformers shall be shipped on individual pallets (one transformer per pallet). Transformers shall be securely attached to the pallets to allow for forklift handling. 20.4. Rejection Of Shipment 20.4.1. Transformers exhibiting damaged parts, broken securing devices, or are dirty from lack of proper shipping, shall be cause for rejection of shipment. 12/2/2011 Page 7 of 8

21. SPECIFICATIONS REVISIONS LOG # Date Description 1 9/18/07 Added Specifications Revision Log 2 9/18/07 Added requirement for heat or cold shrink secondary leads caps 3 9/18/07 Added requirement that all welds, plugs, nameplates shall be 401 SS or brass. 4 9/18/07 Added requirement that unit be painted ANSI 70 Sky Gray. 5 12/2/11 Updated fuse part numbers and corrected formatting to match other specs 12/2/2011 Page 8 of 8