CFD ANALYSIS OF WASTE HEAT BOILER

Similar documents
Analysis of Flue Gas Flow Behavior in Economiser Duct Using Cfd

Optimization of Air Preheater Design for the Enhancement of Heat Transfer Coefficient

Thermal Stress and Creep Analysis of Failure tube of Secondary Super heater

CFD ANALYSIS OF CONVECTIVE FLOW IN A SOLAR DOMESTIC HOT WATER STORAGE TANK

Verification and Validation of Preliminarily Result of CFD of Electrostatic Precipitator Mr.Dharmendra Dekate 1 Mr.K.M.Narkar 2

Oil Conservation in Biscuit Industry

CFD ANALYSIS OF MINI CHANNEL HEAT EXCHANGER USING WATER AS A WORKING FLUID

Performance Analysis for Natural Draught Cooling Tower & Chimney through Numerical Simulation

DESIGN, SIMULATION AND ANALYSIS OF A HYBRID-TYPE (PV/T) SOLAR AIR HEATER FOR HIGH PERFORMANCE

ENHANCEMENT OF COEFFICIENT OF PERFORMANCE IN VAPOUR COMPRESSION REFRIGERATION CYCLE

Design of a Small Scale CFB Boiler Combustion Chamber for Laboratory Purposes

CFD Analysis of Domestic Centrifugal Pump for Performance Enhancement

IJSRD - International Journal for Scientific Research & Development Vol. 4, Issue 06, 2016 ISSN (online):

Simulation of Melting Process of a Phase Change Material (PCM) using ANSYS (Fluent)

Effect of Twisted Tape Inserts On Heat Transfer in A Concentric Tube Heat Exchanger

Heat Transfer Simulation of Impinging Jet with Finned Heat Sink

HIGH PRESSURE BOILERS

Chapter 2.6: FBC Boilers

THERMAL ANALYSIS OF A GAS TURBINE BLADE

CFD ANALYSIS OF CALANDRIA BASED NUCLEAR REACTOR: PART-II. PARAMETRIC ANALYSIS OF MODERATOR

COMPUTATIONAL FLUID DYNAMIC COMBUSTION MODELLING OF A BAGASSE BOILER

Numerical Analysis to Predict the Aerodynamic Performance of Tilt Wing of a Solar Powered UAV

Derivation of Global Parametric Performance of Mixed Flow Hydraulic Turbine Using CFD. Ruchi Khare, Vishnu Prasad and Sushil Kumar

PERFORMANCE ANALYSIS OF NATURAL DRAFT WET COOLING TOWER AT OPTIMIZED INJECTION HEIGHT

Performance Study of Solar Air Heater with Baffled Duct

Heat Transfer Augmentation of Air Cooled Internal Combustion Engine Using Fins through Numerical Techniques

Computational Fluid Dynamics Technology Applied to High Performance, Reliable Axial Compressors for Power Generation Gas Turbines

Experimental Investigation of Tubular Heat Exchangers to Enhance Performance Characteristics

Aerodynamic Design of 2.5 MW Horizontal Wind Turbine Blade in Combination with CFD Analysis

Design and distribution of air nozzles in the biomass boiler assembly

Design and Analysis of 3D Blades for Wells Turbine

CFD analysis of double-chambered crematories using biomass producer gas as a fuel source

CFD Simulation Studies on Integrated Approach of Solar Chimney and Earth Air Tunnel Heat Exchanger for Building Space Conditioning

In The Name OF God Hampa E ner ner Ener y gy Engineering EEngineering & & Design Company Design Compan

SOME ENERGY-EFFICIENT TECHNOLOGIES IN JAPAN

Design and evaluation of open volumetric air receiver for process heat applications

Safety Issues for High Temperature Gas Reactors. Andrew C. Kadak Professor of the Practice

Comparison between 2D and 3D Hydraulic Modelling Approaches for Simulation of Vertical Slot Fishways

Performance Evaluation of low Pressure energy recovery Tesla turbine

Downsizing a Claus Sulfur Recovery Unit

CHAPTER 1 INTRODUCTION

Optimising design of secondary combustion chambers using CFD

2. TECHNICAL DESCRIPTION OF THE PROJECT

Optimization of embedded Heat Exchanger in a flat plate Integrated Collector Storage Solar Water Heater (ICSSWH), with indirect heat withdrawal.

Effect of Rotation Speed of a Rotary Thermal Wheel on Ventilation Supply Rates of Wind Tower System

SHRI RAMSWAROOP MEMORIAL COLLEGE OF ENGG. & MANAGEMENT B.Tech. [SEM IV (ME-41, 42,43 & 44)] QUIZ TEST-1 (Session: )

Understand boiler performance characteristics. Use these suggestions when buying, designing or optimizing steam generators

MODELING A SHROUD FOR THE WIND TURBINE AND CARRYING A FLUID FLOW ANALYSIS USING CFD SOFTWARE PACKAGE

Introduction To Computational Fluid Dynamics. Presented by Marc Laing CFD Team Manager

International Symposium on Current Research in HydraulicTurbines DESIGN AND CFD ANALYSIS OF PICO HYDRO TURGO TURBINE

Gas turbines have been used for electricity generation. Gas turbines are ideal for this application as they can be started and stopped quickly.

Computational Fluid Dynamics (CFD) Application & Benefits for Cement Plant

Evaluation of the Flow Characteristics in the Intake Structure and Pump Sumps Using Physical Model

Three-Dimensional Numerical Simulation of a Model Wind Turbine

Chapter 8. Vapor Power Systems

Numerical analysis of a three dimensional fluid flow in a flat plate solar collector

CFD modeling of airflows and contaminant transport in an aircraft cabin

CFD Simulation Methodology for Ground-Coupled Ventilation System

Heat Exchangers. Introduction. Classification of heat Exchangers

OUTCOME 2 TUTORIAL 2 STEADY FLOW PLANT

MATHEMATICAL MODELING OF DRYING KINETICS OF CORN IN ELECTRON FIRED FLUIDIZED BED DRYER

Abstract. Nomenclature. A Porosity function for momentum equations L Latent heat of melting (J/Kg) c Specific heat (J/kg-K) s Liquid fraction

Design, CFD Analysis and Fabrication of Solar Flat Plate Collector

Thermal Management of Densely-packed EV Battery Set

Computational study of Staggered and Double Cross Flow Heat Exchanger

Quenching steels with gas jet arrays

Optimization of a Dual-Fuel Low-NOx Combustion System for a Tangentially-Fired Utility Boiler Operating at a High Elevation.

DESIGN AND ANALYSIS OF GATING SYSTEM FOR PUMP CASING

Heat Storage Performance of a Honeycomb Ceramic Monolith

Tananop Piemsinlapakunchon, and Manosh C. Paul

ANSYS Combustion Analysis Solutions - Overview and Update

CFD analysis of high speed Francis hydraulic turbines

FSI ANALYSIS OF TRAILING EDGE REGION COOLING IN HP STAGE TURBINE BLADE

Heat transfer modelling of slot jet impinging on an inclined plate

Advanced combustion systems for tube manufacturing

Australian Journal of Basic and Applied Sciences. Vision based Automation for Flame image Analysis in Power Station Boilers

BAG FILTERS (BAGHOUSES)

Failure Analysis for the Economizer Tube of the Waste Heat Boiler

Study of Performance of Solar Photovoltaic Thermal Collector at Different Temperatures

Design and Analysis of Air Distributors and Bed Materials of Fluidized Bed Boiler

Design and Fatigue Analysis of Turbine Rotor Blade by Using F.E.M

Recent Technologies for Steam Turbines

Stress Study on Different Designs of Ceramic High Temperature Heat Exchangers

Preparatory study for Steam Boilers Ecodesign

CFD Analysis of Clarifier Performance With and Without Energy Dissipating Inlet

Design and Analysis of Hydraulic Oil Cooler by Application of Heat Pipe

Thermal Analysis of Solar Flat Plate Collector

THERMAL ANALYSIS OF CPU WITH VARIABLE BASEPLATE HEAT- SINK USING CFD

Numerical Investigation of the Integration of Heat Transfer Devices into Wind Towers

STUDY OF INTEGRAL CHARACTERISTICS AND EFFICIENCY OF A HEAT EXCHANGER OF THERMOSYPHON TYPE WITH FINNED TUBES

Latest Simulation Technologies for Improving Reliability of Electric Power Systems

Performance Optimization of Steam Power Plant through Energy and Exergy Analysis

The effect of hydrogen containing fuel blends upon flashback in swirl burners. Nick Syred Cardiff School of Engineering Wales, U.K.

Computer modelling of a convective steam superheater

A CFD ANALYSIS OF CENTRIFUGAL PUMP TO IMPROVE DISCHARGE BY VARYING BLADE GEOMETRY

On the topic of gas turbine combustion

CMR Journal of Engineering and Technology Vol.2 Issue.1 June, 2017

Gas Flow How to Improve It to Enhance ESP, Boiler, FGD, SCR, SNCR Performance

Influence of Hot Metal Flow State to the Hearth Flow Field during Blast Furnace Tapping

Steam Power Station (Thermal Station)

Transcription:

CFD ANALYSIS OF WASTE HEAT BOILER SREEKANTH S 1, Dr. BENNY PAUL 2 Abstract Waste Heat boilers are used to recover waste heat from high temperature exhausts in chimney stacks. Waste heat boilers are typically water tube boilers which use large volume, high temperature waste heat streams as a heat source as opposed to conventional fuel. Typical heat sources include hot exhaust gases from such equipment as gas turbines, incinerators, furnaces and reciprocating engines. Should the waste heat in exhaust gases be insufficient for generating the required amount of process steam, it is sometimes possible to add the auxiliary burners. These systems burn fuel in the waste heat boiler or an afterburner may be added to the exhaust gas duct just ahead of the boiler.in this analysis, flow simulation (CFD) of the Regenerative Air (RA) & Gas Turbine (GT) ducts along with inlet pipes and mixing chamber were carried out for various configurations to identify the real cause for the vibrations developed. An amicable solution identified was to guide the flow properly through the RA duct with guide plates to eliminate the vortex generation and circulation induced which was the primary cause for vibrations developed in the duct assembly. Index Terms CFD (Computational Fluid Dynamics), Waste Heat Boiler, RA (Regenerative Air), GT(Gas Turbine). I. INTRODUCTION Waste heat boilers are ordinarily water tube boilers in which the hot exhaust gases from gas turbines, incinerators, etc., pass over a number of parallel tubes containing water. The water is vaporized in the tubes and collected in a steam drum from which it is drawn out for use as heating or processing steam. Because the exhaust gases are usually in the medium temperature range and in order to conserve space, a more compact boiler can be produced if the water tubes are finned in order to increase the effective heat transfer area on the gas side The flue gas temperature, pressure and velocity field of fluid flow within an economizer tube using the actual boundary conditions have been analyzed using CFD tool. II. LITREATURE REVIEW Krunal P. Mudafale & Hemant S. Farkade[1] work on CFD analysis of economizer in atengential fired boiler.a.d.patil, P.R.Baviskar, M.J.Sable, S.B.Barve[2] work on To optimize economizer design for better performance This paper focuses on optimization of economiser design with finned & baretube economiser. The aim of this work is to develop methodology which finds optimisation of economiser design. TSUNG-FENG WU[4] work on failure analysis for economizer tube of the waste heat. This paper is about failure analysis of the leakage of the economizer tube of the waste heat boiler inthe energy factory. The results show that although the material and mechanical properties of thefailed tube, were inferior to those of the new one, most of them were still satisfactory to the criterion requirement it is clear that the crack initiated in the outer surface and propagated toward the innersurface of the tube and the crack was identified to be rectangular in shape. Deendayal Yadav, Dr. G. V. Parishwad, P. R. Dhamangaonkar*, Dr. S. R. Kajale, Dr. M. R.Nandgaonkar, Dr. S. N. Sapali.[5] work on effect of arreasters on erosion in economizer zone and its analysis. The authors in this paper have attempted to suggest a probable solution for reduction of erosion in economizer zone and its analysis using CFD tool. In this paper the authors have submitted the findings of analysis of finned tube economizer with Arresters at different inclinations distribution. Saripally et al. (2005) conducted a computational fluid dynamics simulation of thermal flow in an industrial boiler. Simulation has been done to understand the thermal flow inside the boiler tube to resolve the operational problem and search for optimal solution. During the analysis, the geometry of the system and boundary conditions such as inlet velocities and flow rate was changed to view their effect on thermal flow patterns or species concentration. In this analysis, flow simulation (CFD) of the Regenerative Air (RA) & Gas Turbine (GT) ducts along with inlet pipes and mixing chamber is carried out for various configurations to identify the real cause for the vibrations developed. Manuscript received September, 2015. Sreekanth S, PG Scholar, Department of Mechanical Engg, Mar Athanasius College of Engineering, Kothamangalam 9961822511 Dr Benny Paul, Professor, Department of Mechanical Engg, Mar Athanasius College of Engineering, Kothamangalam 3624

III. MODEL DESCRIPTION This chapter introduces the reader to the setup used in the experiments. The important and unique aspects of the setup are described: A.PROBLEM ANALYSIS At the plant location, vibration problem for the transition duct between the gas turbine and the Waste Heat Boiler (WHB) was identified and a solution was sought. For this, various data needs to be collected so that the actual cause of vibration can be pointed out and a proper solution can be framed. The input data was collected from the plant and the problem statement was identified based on discussions for detailed investigation, solution and reporting. Input study revealed variations in the operating parameters (mass flow rate) when Operational Trends was compared with PFD data. As per PFD data the mass flow rate need to be 337kg/s & 147kg/s in the RA &GT duct respectively. But the Operational Trends recorded a maximum mass flow rate of 1073kg/s & 62kg/s in the RA & GT duct respectively. Based on this observation it was proposed to study the flow physics occurring the RA & GT ducts both as per PFD data & Operational Trends. This approach will help to identify the existing operational problems of the Waste Heat Boiler (WHB) Transition Duct. FLUID FLUE GAS B.GEOMETRY CREATION After careful analysis of the problem, a geometry of the desired part needs to be created for further investigation. Based on the information from input data a geometry was constructed using the software Catia V5 R20. Fig.3.1Geometry created using Catia V5 R20 C.MESHING The created geometry is meshed using Ansys ICEM CFD. The meshed geometries are shown below. Temperature at RA & GT 857 K & 901 K inlets Mass Flow Rate at RA & GT 337 Kg/s & 147 Kg/s inlets Density (ρ) 0.6214.5 kg/m 3 Viscosity (μ) 0.0284 Kg/ m-s Conductivity (k) 0.042749 W/m K Specific Heat (C p ) 1099.87 J/kg K Table.3.1Input data Fig.3.2The meshed geometry The meshed geometry is used as the input for CFD software fluent for flow simulation. D. ROOT CAUSE ANALYSIS AND MODIFIED GEOMETRY Computational domain contains around 46001elements & 45122 nodes. Relevance centre is set as fine and smoothing is high and 60 is given because after that value there is no remarkable change in temperature. All other settings are to be done as default. After the cfd analysis the velocity contours and temperature contours of the flow through duct are obtained as follows: 3625

temperature inside the duct. Since we have not changed any parameter used in the base geometry other than the addition of plate, we can credit this uniform temperature distribution to the modified geometry. Fig.3.3Velocity contour Fig.3.5Temperature contour Fig3.4Temperature contour From the above results it is clear that the flow is directed towards the bottom of the duct abnormally. To modify the flow into a uniform one, two sets of guide plates are introduced inside the duct. Modified geometry with plates E.FLOW ANALYSIS OF MODIFIED GEOMETRY The modified flow is analyzed using ansys fluent with same set of solver settings and boundary conditions such as the mass flow rate, need to be 337kg/s & 147kg/s in the RA &GT duct respectively and the following flow simulation is obtained. From the temperature contour it is clear that the addition of plate have resulted in uniform distribution of gas IV.RESULTS AND DISCUSSION In this chapter we analyse the results obtained with the help of computational fluid dynamics (CFD). The thermal and fluid flow characteristics of the present problem were numerically simulated by computational fluid dynamics (CFD) technique. Commercial package ANSYS 14.5 is used for the present study. As per the data the mass flow rate need to be 337kg/s & 147kg/s in the RA &GT duct respectively. But the Operational Trends recorded a maximum mass flow rate of 1073kg/s & 62kg/s in the RA & GT duct respectively. Based on this observation a study on the flow physics occurring inside the RA & GT ducts both as per data & Operational Trends were carried out. This approach helped to identify the existing operational problems of the Waste Heat Boiler (WHB) Transition Duct. The existing structure inclusive of Inlet pipes, RA duct, GT duct & Mixing Chamber (MC) was subjected to analysis with and without Super Heater (SH))section. As a part of our study various configurations were analyzed for identifying the 3626

causes for vibration and to suggest an optimized solution resulting in mitigation of induced vibration. A suitable solution to the vibrations developed was to reduce the turbulent flow of gas inside the duct.for this a suitable solution has to be found. One of the most convenient ways of getting this done was the use of guide plates inside the duct. This will help us in reducing the cost as well vibrations without heavy modification of the duct. First the CFD Analysis for an existing design of the RA & GT Duct to get the details of the Turbulence happening in the Ducts were done. Then Remodeling the existing model by adding plates once longitudinally and then transversally in the Divergent Suction to Check for occurrence of turbulence were done followed by its CFD Analysis. During the analysis the number of elements can be varied, when the number of elements increases, the accuracy of the results also increases.when the elements in the meshing are low which results in lowering the accuracy. One of the important result obtained as a result of the remodeled design was evident in the velocity streamline as shown in the figure.here we can see that the insertion of guide plates have given way for the turbublent flow to be transformed into streamline flow.as a result the vibrations got reduced and the life of RA duct, GT duct & Mixing Chamber (MC) were improved. V.SCOPE a) Run the CFD Analysis for an existing design of the RA & GT Duct to get the details of the Turbulence happening in the Ducts. b) Remodelling the existing model by adding plates once longitudinally and then transversally in the Divergent Suction to Check for occurrence of turbulence. c) A better optimization of these plates have to be done in order to achieve the flow uniformity in the duct. d) Remodelling with plates both longitudinal and transverse and to run the solver. e) Conforming whether the design is satisfying the required criteria. VII.VALIDATION OF PFD DATA CFD analysis for verification of the mass balance of the RA duct-gt duct-mc section was carried out to validate the PFD data as a part of input study. The purpose of this analysis was to carry out the material and mass balance across the RA duct, GT duct and the Mixing chamber. The Feed Streams conditions were chosen so as to match the PFD and is one among the various analysis results obtained from the client end The objective was to check mass balance of the stream 3 from the given values of both stream 1 and stream 2. The stream 1 & 2 properties from PFD data were entered onto a virtual simulating software and stream 3 parameter were calculated as output. VII. CONCLUSION The waste-heat boiler is the common choice for heat recovery. According to the literature it is clear that successful operation of the boiler requires sufficient understanding of the process and its operating conditions. Computational fluid dynamic modeling did prove to be a valuable aid in providing insight into the flow and temperature profiles within the waste-heat boiler. It was possible to identify and quantify the contribution of turbulence and radiation effects. However, most of the analysis was done qualitatively. Based on the findings obtained, the following significant conclusions can be made: Fig.4.1Velocity streamline CFD Analysis for an existing design of the RA & GT Duct were carried out to get the details of the Turbulence happening in the Ducts. 3627

CFD Analysis of the remodeled design with guide plates were carried out to check for occurrence of turbulence. The placement of guide plates did have the desired effect of further enhancing the heat transfer while also distributing the off-gas flow more evenly through the waste-heat boiler duct. Sreekanth S, PG student, Mechanical(Thermal Power Engineering)Mar Athanasius College of Engineering, Kothamangalam,kerala, India. Born on 27 th Nov 1991.He has completed his graduation in Mechanical Engineering, from Annamalai University, Chidambaram. VIII.REFERENCES [1] Krunal P. Mudafale & Hemant S. Farkade CFD analysis of economizer in a tengential fired boiler, International Journal of Mechanical and Industrial Engineering (IJMIE) ISSN No. 2231 6477, Vol-2, Iss-4, 2012. [2] A.D.Patil, P.R.Baviskar, M.J.Sable, S.B.Barve to optimize economizer design for better performance, New aspects of fluid mechanics, heat transfer and environment isbn: 978-960-474-215-8. [3] A.D.Patil, P.R.Baviskar, M.J.Sable, S.B.Barve Optimization of Economiser Design for the Enhancement of Heat Transfer Coefficient, International Journal of Applied Research In Mechanical Engineering (IJARME), ISSN: 2231 5950 Volume-1, Issue-2, 2011. [4] TSUNG-FENG WU Failure Analysis for the Economizer Tube of the Waste Heat Boiler. [5] Deendayal Yadav, Dr. G. V. Parishwad, P. R. Dhamangaonkar*, Dr. S. R. Kajale, Dr. M. R.Nandgaonkar, Dr. S. N. Sapali Effect of Arresters on Erosion in Economizer Zone and itsanalysis, AMAE Int. J. on Production and Industrial Engineering, Vol. 01, No. 01, Dec 2010. [6] A.N. Aziz, P. Siregar, Y.Y. Nazaruddin, and Y. Bindar Improving the Performance of Temperature Model of Economizer Using Bond Graph and Genetic Algorithm, International Journal of Engineering & Technology IJET-IJENS Vol: 12 No: 01. [7] N.S. Venkatesh Kumar and Prof. K. Hema Chandra Reddy, CFD Analysis of Wind Driven Natural Cross Ventilation for a Generic Isolated Building, International Journal of Mechanical Engineering & Technology (IJMET), Volume 4, Issue 5, 2013, pp. 200-207, ISSN Print: 0976 6340, ISSN Online: 0976 6359. [8] Sanjay Kumar Patel and Dr. A.C. Tiwari, Performance Analysis of Supercritical Boiler, International Journal of Mechanical Engineering & Technology (IJMET), Volume 3, Issue 2, 2012, pp. 422-430, ISSN Print: 0976 6340, ISSN Online: 0976 6359. Dr Benny Paul, Professor, Department of Mechanical Engg, Mar Athanasius College of Engineering, Kothamangalam 3628