SECTION NON-STRUCTURAL METAL FRAMING

SECTION ACOUSTICAL PANEL CEILINGS

1. Interior gypsum wallboard. 2. Exterior gypsum board panels for ceilings and soffits. 3. Tile backing panels.

A. This Section includes acoustical panel ceilings installed with exposed suspension systems.

PRESTON HEALTH SERVICES ARCHITECT'S NO. 2700

UNIVERSITY SERVICES ANNEX James Madison University Harrisonburg, Virginia State Project Code: Architect s Project Number:

Student Services & Classroom Addition

SECTION GYPSUM BOARD ASSEMBLIES

SECTION GYPSUM BOARD

1. Nonload-bearing steel framing members for gypsum board assemblies. 2. Gypsum board assemblies attached to steel framing.

Retain "Preinstallation Conference" Paragraph below if Work of this Section is extensive or complex enough to justify a conference.

ONE SCHOOL STREET SEPTEMBER 18, 2008 GOWANDA, NEW YORK ARCH PROJECT NO

SECTION ACOUSTICAL PANEL CEILINGS. A. Section includes acoustical panels and exposed suspension systems for ceilings.

BEARING METAL STUD FRAMING

Chevy Chase Club June 30, 2008 Bowie Gridley Architects SECTION GYPSUM BOARD SHAFT WALL ASSEMBLIES

EXCEL Medical Waste - Equipment Installation Section SECTION GYPSUM BOARD

LINEAR METAL CEILINGS Section

SECTION COLD-FORMED METAL FRAMING

A. Types of lightgauge metal framing units include the following: 1. C-shaped structural steel studs Uniform Building Code.

AND ACCESSORIES FOR DRYWALL CONSTRUCTION

CONTRACT NUMBER: W912DQ-08-C % CORRECTED DESIGN 28 JULY 2008

STEEL STUD, TRIMS AND ACCESSORIES FOR DRYWALL CONSTRUCTION MONTREAL TORONTO CALGARY EDMONTON VANCOUVER THE STRENGTH WITHIN

A. This Section includes ceilings consisting of acoustical panels and exposed suspension systems.

COOK COUNTY ILLINOIS CONTRACT FOR WORK DOCUMENT NO Countywide Warehouse and Records Storage Center Hawthorne Project TKB No.

Technical Services Information Bureau

EDGEWATER, FLORIDA JUNE 14, 2010

SECTION ACOUSTICAL PANEL CEILINGS PART 1 - GENERAL

SECTION LINEAR METAL CEILINGS

SECTION ACCORDION FOLDING PARTITIONS

SECTION RADIATION SHIELDING ENCLOSURE Low Intensity Radiation Protection

GYPSUM BOARD SECTION GYPSUM BOARD PART 1 - GENERAL

SECTION STEEL DECKING

Union County Vocational - Technical Schools Scotch Plains, New Jersey

A. Product Data: For each component of gypsum board shaft wall assembly.

Suspension Systems for Acoustical Lay-in Ceilings Seismic Design Categories D, E & F

SECTION HANGERS AND SUPPORTS FOR PLUMBING

UL Design System HW-D-1012 continued

On Cold-Formed Steel Construction. Light Gauge Steel Engineers Association Washington, D.C Toll Free (866)

SECTION VIBRATION AND SEISMIC CONTROLS FOR ELECTRICAL SYSTEMS

1. Non-load-bearing steel framing systems for interior partitions. 2. Grid suspension systems for gypsum board ceilings.

Shaftwall and Area Separation Wall Systems.

JC Code & Construction Consultants, Inc. Advanced Training: The FBC & ASTM C 1063

SECTION GYPSUM WALLBOARD. A. PART A and DIVISION 1 of PART B are hereby made a part of this SECTION.

B. Do not install interior products until installation areas are enclosed and conditioned.

SECTION HANGERS AND SUPPORTS FOR ELECTRICAL SYSTEMS

I-STUD Shaftwall System

SECTION [ ] COILING COUNTER DOORS. Display hidden notes to specifier. (Don't know how? Click Here)

Cavity ShAftwall System

SECTION Specification for Building Limes Specification For Building Sands from Natural Sources Methods of Tests for Paints.

SECTION GYPSUM BOARD

DIVISION: FINISHES SECTION: SUSPENSION SYSTEMS SECTION: ACOUSTICAL CEILING SUSPENSION ASSEMBLIES REPORT HOLDER:

Assemblies Evaluated For 1. Non Axial Load Bearing Wall 2. Transverse Load Capacity 3. Fire Resistance 4. Abuse Resistance

REPORT HOLDER: GYPSUM ASSOCIATION 962 WAYNE AVENUE, SUITE 620 SILVER SPRING, MARYLAND EVALUATION SUBJECT:

I-STUD Shaftwall System

The Contractor is responsible for quality control, including workmanship and materials furnished by his subcontractors and suppliers.

DIVISION 10 SPECIALTIES SECTION OPERABLE PARTITIONS

SECTION BASIC ELECTRICAL MATERIALS AND METHODS

SECTION PLATE CONNECTED WOOD TRUSSES

Section GYPSUM DRYWALL

SECTION HANGERS AND SUPPORTS FOR PLUMBING PIPING AND EQUIPMENT

Northpointe Renovation EPN #1701 F/A Project #17027 September 8, 2017

Shaftwall & Stairwell Systems Fire protection & sound isolation for shafts & stairwells

MODERNFOLD GWS 100SR-G MOVEABLE GLASS WALLS

Interior Hangers. Application

A. Access doors and frames are part of an access door and frame allowance.

Daytona Beach Pier Building Renovation Jun 2010

HANGERS AND SUPPORTS FOR HVAC PIPING AND EQUIPMENT SECTION HANGERS AND SUPPORTS FOR HVAC PIPING AND EQUIPMENT

A. Product Data: Submit manufacturer's product data for cementitious materials, lath, metal support components, and accessories.

WHY I SHOULD SPECIFY AND USE FAS TRACK 1000?

The Passive Fire Protection Handbook

ACCESSORY STRUCTURE Building permit information For 1 & 2-family dwellings

1.1 RELATED DOCUMENTS

B. Shop Drawings: For metal lockers. Include plans, elevations, sections, details, and attachments to other work.

PROJECT LOCATION SECTION COPPER METAL PLATE WALL PANELS

SECTION OVERHEAD COILING FIRE DOORS MODEL 662 OVERHEAD COILING COUNTER FIRE DOORS WITH INTEGRAL FRAME

UNIFIED FACILITIES GUIDE SPECIFICATIONS

Anchor bolts ASTM F1554, Gr. 36 Wide flange beams ASTM A992, Fy = 50 ksi Misc. structural steel ASTM A36, Fy = 36 ksi

Acousti-Seal Encore Paired Panel (10650) Operable Partitions

Aluminum-Framed Entrances and Storefronts

Specifiers: Click on the icon in the WORD toolbar to reveal detailed instructions

CHAPTER 6 TYPES OF CONSTRUCTION

A. Submit the following in addition to the standard requirements.

NORTH HARRIS COUNTY REGIONAL WATER AUTHORITY PIPE HANGERS, Section PIPE HANGERS, SUPPORTS, AND RESTRAINTS

COLLEGE CLASSROOM & DORMITORY SPECIFICATION SECTION 08100

2012 & 2015 International Building Code. Section Section Section Section Section Section 713.4

DIVISION 15-MECHANICAL SECTION SUPPORTS AND ANCHORS PN PART 1 - GENERAL 1.01 SECTION INCLUDES. A. Pipe and equipment support systems.

NATIONAL GYPSUM COMPANY Wood Frame Walls And Ceilings Single- And Double-Layer Construction

SECTION (Master Template Final-05) ELECTRICAL BOXES. A. Provide boxes for electrical equipment and wiring devices as follows:

Division 11 - Equipment Section 11401

Product Designation As specified in the AISI standard for cold formed steel framing General provisions A5.2.

For Best Non-Structural Steel Stud Specifications, Stay Apprised of Industry Standard Requirements

MASTERSPEC - SHORT FORM. B. See Division 5 Section "Metal Stairs" for steel tube railings associated with metal stairs.

SECTION HANGERS AND SUPPORTS FOR PLUMBING PIPING AND EQUIPMENT

SECTION VIBRATION CONTROLS FOR HVAC PIPING AND EQUIPMENT

GUIDE SPECIFICATIONS CURA ADJUSTABLE REROOF FRAMING SYSTEMS SECTION REROOFING ADJUSTABLE FRAMING SYSTEM

SECTION ROOF SPECIALTIES

The Contractor is responsible for quality control, including workmanship and materials furnished by his subcontractors and suppliers.

NORTHWESTERN UNIVERSITY PROJECT NAME JOB # ISSUED: 03/29/2017

SECTION CRL50 AND CRL51 HEAVY GLASS TOP HUNG SLIDING DOOR SYSTEMS

SECTION HVAC GRAVITY VENTILATORS

Transcription:

SECTION 09 2116 - NON-LOAD-BEARING STEEL FRAMING PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 1 Specification Sections, apply to this Section. 1.2 SUMMARY A. Section Includes: 1. Non-load-bearing steel framing systems for interior gypsum board assemblies. 2. Suspension systems for interior gypsum ceilings, soffits, and grid systems. B. Related Requirements: 1. Division 05 Section "Cold-Formed Metal Framing" for exterior and interior loadbearing and exterior non-load-bearing wall studs; floor joists; roof rafters and ceiling joists; and roof trusses. 1.3 DESIGN REQUIREMENTS A. Provide non-load bearing steel stud partitions with deflections conforming to L/240 at 5 PSF typical for gypsum board walls. 1. Calculate additional loading for partition walls that support cabinets, fixtures, equipment services, heavy trim, grab bars, toilet accessories, furnishings, and similar construction to comply with details indicated on Drawings and with "Gypsum Construction Handbook" published by United States Gypsum Company. B. Fire-Resistive Rating: Where indicated on Drawings, provide materials and construction that are identical to those assemblies whose fire resistance rating has been determined per ASTM E119 by a testing and inspecting organization acceptable to authorities having jurisdiction. 1. Meet or exceed fire resistance requirements outlined under provisions of the GA- 600 Fire Resistance Design Manual for wall and ceiling assemblies. 2. Meet or exceed flame/fuel/smoke requirements of ASTM E84 surface burning characteristics for finish materials. C. Sound Transmission Characteristics: For gypsum board assemblies with STC ratings, provide materials and construction identical to those tested in assembly indicated according to ASTM E 90 and classified according to ASTM E 413 by a qualified independent testing agency. NON-LOAD-BEARING STEEL FRAMING 09 2116-1

1.4 SUBMITTALS A. Product Data: For each type of product. B. LEED Submittals: 1. Product Data for Credit MR 4: For products having recycled content, documentation indicating percentages by weight of postconsumer and preconsumer recycled content. Include statement indicating costs for each product having recycled content. C. Shop Drawings: Indicate details associated with fireproofing and acoustical seals, opening locations and details, and opening termination details. Show locations, fabrication, and installation of control and expansion joints including plans, elevations, sections, details of components, and attachments to other units of Work. PART 2 - PRODUCTS 2.1 MANUFACTURERS A. Subject to compliance with requirements, provide products by one of the following: 1. Grid Suspension System: a. Armstrong World Industries, Inc.; Drywall Grid Systems. b. Chicago Metallic Corporation; Drywall Grid System. c. USG Corporation; Drywall Suspension System. 2. Steel Framing and Furring: a. Dietrich Industries, Inc. b. Clark Steel Framing Systems. c. Dale Industries, Inc. - Dale/Incor. d. MarinoWare; Division of Ware Ind. e. National Gypsum Company. f. Scafco Corporation. 2.2 PERFORMANCE REQUIREMENTS A. Fire-Test-Response Characteristics: For fire-resistance-rated assemblies that incorporate non-load-bearing steel framing, provide materials and construction identical to those tested in assembly indicated, according to ASTM E 119 by an independent testing agency. B. STC-Rated Assemblies: For STC-rated assemblies, provide materials and construction identical to those tested in assembly indicated, according to ASTM E 90 and classified according to ASTM E 413 by an independent testing agency. NON-LOAD-BEARING STEEL FRAMING 09 2116-2

2.3 STEEL SUSPENDED CEILING AND SOFFIT FRAMING A. Grid Suspension System for Interior Gypsum Board Ceilings: ASTM C 645, directhung system composed of main beams and cross-furring members that interlock. B. Tie Wire: ASTM A 641/A 641M, Class 1 zinc coating, soft temper, 0.0625-inchdiameter wire, or double strand of 0.0475-inch- diameter wire. C. Hangers: As follows: 1. Wire Hangers: ASTM A 641/A 641M, Class 1 zinc coating, soft temper, 0.162- inch diameter. 2. Flat Hangers: Commercial-steel sheet, ASTM A 653/A 653M, G40, hot-dip galvanized. 2.4 FRAMING SYSTEMS A. Framing Members, General: Comply with ASTM C 754 for conditions indicated. 1. Steel Sheet Components: Comply with ASTM C 645 requirements for metal unless otherwise indicated. 2. Protective Coating: ASTM A 653/A 653M, G60, hot-dip galvanized unless otherwise indicated. B. Studs and Runners: ASTM C 645. Use either steel studs and runners or dimpled steel studs and runners. 1. Unless specifically indicated otherwise, provide not smaller than 3-5/8 in., nor lighter than 25 gauge prepunched studs for vertical members and continuous, not lighter than 25 gauge unpunched tracks at top and bottom of studs. Provide minimum 20 gauge members at door jambs and heads. Provide larger members where specifically indicated on Drawings and in accord with manufacturer s limiting heights table. 2. Protective Coating: ASTM A 653/A 653M, G60, hot-dip galvanized unless otherwise indicated. C. Slip-Type Head Joints: Where indicated, provide one of the following: 1. Single Long-Leg Runner System: ASTM C 645 top runner with 2-inch- deep flanges in thickness not less than indicated for studs, installed with studs friction fit into top runner and with continuous bridging located within 12 inches of the top of studs to provide lateral bracing. 2. Double-Runner System: ASTM C 645 top runners, inside runner with 2-inchdeep flanges in thickness not less than indicated for studs and fastened to studs, and outer runner sized to friction fit inside runner. 3. Deflection Track: Steel sheet top runner manufactured to prevent cracking of finishes applied to interior partition framing resulting from deflection of structure above; in thickness not less than indicated for studs and in width to accommodate depth of studs. NON-LOAD-BEARING STEEL FRAMING 09 2116-3

a. Products: Subject to compliance with requirements, available products that may be incorporated into the Work include, but are not limited to, the following: 1) Dietrich Metal Framing; SLP-TRK Slotted Deflection Track. 2) MBA Building Supplies; FlatSteel Deflection Track. 3) Steel Network Inc. (The); VertiClip SLD Series. 4) Superior Metal Trim; Superior Flex Track System (SFT). 5) Telling Industries; Vertical Slip Track. D. Firestop Tracks: Top runner manufactured to allow partition heads to expand and contract with movement of the structure while maintaining continuity of fire-resistancerated assembly indicated; in thickness not less than indicated for studs and in width to accommodate depth of studs. 1. Products: Subject to compliance with requirements, available products that may be incorporated into the Work include, but are not limited to, the following: a. Fire Trak Corp.; Fire Trak System attached to studs with Fire Trak Posi Klip. b. Grace Construction Products; FlameSafe FlowTrak System. c. Metal-Lite, Inc.; The System. d. Steel Network Inc. (The); VertiClip SLD Series. E. Flat Strap and Backing Plate: Steel sheet for blocking and bracing in length and width indicated. 1. Minimum Base-Metal Thickness: As indicated on Drawings. F. Cold-Rolled Channel Bridging: Steel, 0.053-inch minimum base-metal thickness, with minimum 1/2-inch- wide flanges. 1. Depth: As indicated on Drawings. 2. Clip Angle: Not less than 1-1/2 by 1-1/2 inches, 0.068-inch- thick, galvanized steel. G. Hat-Shaped, Rigid Furring Channels: ASTM C 645. 1. Minimum Base-Metal Thickness:. 2. Depth: As indicated on Drawings [1-1/2 inches]. H. Resilient Furring Channels: 1/2-inch- deep, steel sheet members designed to reduce sound transmission. 1. Configuration: hat shaped. I. Cold-Rolled Furring Channels: 0.053-inch uncoated-steel thickness, with minimum 1/2-inch- wide flanges. 1. Depth: As indicated on Drawings 3/4 inch. NON-LOAD-BEARING STEEL FRAMING 09 2116-4

2. Furring Brackets: Adjustable, corrugated-edge type of steel sheet with minimum uncoated-steel thickness of 0.033 inch. 3. Tie Wire: ASTM A 641/A 641M, Class 1 zinc coating, soft temper, 0.062-inchdiameter wire, or double strand of 0.048-inch- diameter wire. J. Z-Shaped Furring: With slotted or nonslotted web, face flange of 1-1/4 inches, wall attachment flange of 7/8 inch, minimum uncoated-metal thickness of 0.018 inch, and depth required to fit insulation thickness indicated. 2.5 AUXILIARY MATERIALS A. General: Provide auxiliary materials that comply with referenced installation standards. 1. Fasteners for Metal Framing: Of type, material, size, corrosion resistance, holding power, and other properties required to fasten steel members to substrates. B. Isolation Strip at Exterior Walls: Provide one of the following: 1. Asphalt-Saturated Organic Felt: ASTM D 226, Type I (No. 15 asphalt felt), nonperforated. 2. Foam Gasket: Adhesive-backed, closed-cell vinyl foam strips that allow fastener penetration without foam displacement, 1/8 inch thick, in width to suit steel stud size. PART 3 - EXECUTION 3.1 EXAMINATION A. Examine areas and substrates, with Installer present, and including welded hollowmetal frames, cast-in anchors, and structural framing, for compliance with requirements and other conditions affecting performance of the Work. B. Proceed with installation only after unsatisfactory conditions have been corrected. 3.2 PREPARATION A. Suspended Assemblies: Coordinate installation of suspension systems with installation of overhead structure to ensure that inserts and other provisions for anchorages to building structure have been installed to receive hangers at spacing required to support the Work and that hangers will develop their full strength. 1. Furnish concrete inserts and other devices indicated to other trades for installation in advance of time needed for coordination and construction. B. Coordination with Sprayed Fire-Resistive Materials: 1. Before sprayed fire-resistive materials are applied, attach offset anchor plates or ceiling runners (tracks) to surfaces indicated to receive sprayed fire-resistive materials. Where offset anchor plates are required, provide continuous plates fastened to building structure not more than 24 inches o.c. NON-LOAD-BEARING STEEL FRAMING 09 2116-5

2. After sprayed fire-resistive materials are applied, remove them only to extent necessary for installation of non-load-bearing steel framing. Do not reduce thickness of fire-resistive materials below that required for fire-resistance ratings indicated. Protect adjacent fire-resistive materials from damage. 3.3 INSTALLATION, GENERAL A. Installation Standard: ASTM C 754. 1. Gypsum Board Assemblies: Also comply with requirements in ASTM C 840 that apply to framing installation. B. Install supplementary framing, and blocking to support fixtures, equipment services, heavy trim, grab bars, toilet accessories, furnishings, or similar construction. C. Install bracing at terminations in assemblies. D. Do not bridge building control and expansion joints with non-load-bearing steel framing members. Frame both sides of joints independently. 3.4 INSTALLING FRAMED ASSEMBLIES A. Install framing system components according to spacings indicated, but not greater than spacings required by referenced installation standards for assembly types. 1. Single-Layer Application: 16 inches o.c. unless otherwise indicated. 2. Multilayer Application: 16 inches o.c. unless otherwise indicated. 3. Tile Backing Panels: 16 inches o.c. unless otherwise indicated. B. Where studs are installed directly against exterior masonry walls or dissimilar metals at exterior walls, install isolation strip between studs and exterior wall. C. Install studs so flanges within framing system point in same direction. D. Install tracks (runners) at floors and overhead supports. Extend framing full height to structural supports or substrates above suspended ceilings except where partitions are indicated to terminate at suspended ceilings. Continue framing around ducts penetrating partitions above ceiling. 1. Slip-Type Head Joints: Where framing extends to overhead structural supports, install to produce joints at tops of framing systems that prevent axial loading of finished assemblies. 2. Door Openings: Screw vertical studs at jambs to jamb anchor clips on door frames; install runner track section (for cripple studs) at head and secure to jamb studs. a. Install two studs at each jamb unless otherwise indicated. b. Install cripple studs at head adjacent to each jamb stud, with a minimum 1/2-inch clearance from jamb stud to allow for installation of control joint in finished assembly. NON-LOAD-BEARING STEEL FRAMING 09 2116-6

c. Extend jamb studs through suspended ceilings and attach to underside of overhead structure. 3. Other Framed Openings: Frame openings other than door openings the same as required for door openings unless otherwise indicated. Install framing below sills of openings to match framing required above door heads. 4. Blocking: Bolt or screw steel channels to metal studs. Install concealed wood blocking for support of plumbing fixtures, toilet partitions, wall cabinets, toilet accessories, hardware, and other related items that require backing for support under provisions of Section 06 1000. 5. Fire-Resistance-Rated Partitions: Install framing to comply with fire-resistancerated assembly indicated and support closures and to make partitions continuous from floor to underside of solid structure. a. Firestop Track: Where indicated, install to maintain continuity of fireresistance-rated assembly indicated. 6. Sound-Rated Partitions: Install framing to comply with sound-rated assembly indicated. 7. Curved Partitions: E. Direct Furring: a. Bend track to uniform curve and locate straight lengths so they are tangent to arcs. b. Begin and end each arc with a stud, and space intermediate studs equally along arcs. On straight lengths of no fewer than two studs at ends of arcs, place studs 6 inches o.c. 1. Attach to concrete or masonry with stub nails, screws designed for masonry attachment, or powder-driven fasteners spaced 24 inches o.c. F. Installation Tolerance: Install each framing member so fastening surfaces vary not more than 1/8 inch from the plane formed by faces of adjacent framing. 3.5 INSTALLING SUSPENSION SYSTEMS A. Install suspension system components according to spacings indicated, but not greater than spacings required by referenced installation standards for assembly types. 1. Hangers: 48 inches (1219 mm) o.c. 2. Carrying Channels (Main Runners): 48 inches o.c. 3. Furring Channels (Furring Members): 16 inches o.c. B. Isolate suspension systems from building structure where they abut or are penetrated by building structure to prevent transfer of loading imposed by structural movement. C. Suspend hangers from building structure as follows: 1. Install hangers plumb and free from contact with insulation or other objects within ceiling plenum that are not part of supporting structural or suspension system. NON-LOAD-BEARING STEEL FRAMING 09 2116-7

a. Splay hangers only where required to miss obstructions and offset resulting horizontal forces by bracing, countersplaying, or other equally effective means. 2. Where width of ducts and other construction within ceiling plenum produces hanger spacings that interfere with locations of hangers required to support standard suspension system members, install supplemental suspension members and hangers in the form of trapezes or equivalent devices. a. Size supplemental suspension members and hangers to support ceiling loads within performance limits established by referenced installation standards. 3. Wire Hangers: Secure by looping and wire tying, either directly to structures or to inserts, eye screws, or other devices and fasteners that are secure and appropriate for substrate, and in a manner that will not cause hangers to deteriorate or otherwise fail. 4. Flat Hangers: Secure to structure, including intermediate framing members, by attaching to inserts, eye screws, or other devices and fasteners that are secure and appropriate for structure and hanger, and in a manner that will not cause hangers to deteriorate or otherwise fail. 5. Do not attach hangers to steel roof deck. 6. Do not attach hangers to permanent metal forms. Furnish cast-in-place hanger inserts that extend through forms. 7. Do not attach hangers to rolled-in hanger tabs of composite steel floor deck. 8. Do not connect or suspend steel framing from ducts, pipes, or conduit. D. Fire-Resistance-Rated Assemblies: Wire tie furring channels to supports. E. Grid Suspension Systems: Attach perimeter wall track or angle where grid suspension systems meet vertical surfaces. Mechanically join main beam and cross-furring members to each other and butt-cut to fit into wall track. F. Installation Tolerances: Install suspension systems that are level to within 1/8 inch in 12 feet measured lengthwise on each member that will receive finishes and transversely between parallel members that will receive finishes. END OF SECTION 09 2116 NON-LOAD-BEARING STEEL FRAMING 09 2116-8