Standard and Mini Split Line Sets

Similar documents
Tube Insulation. Fiber Free

Armacell Product Selection Guide

Redi-Klad 1000 Pipe Insulation

PRODUCT SELECTION GUIDE

GUIDE SPECIFICATION: DUCT LINER

A. Deliver material to job site in original, nonbroken, factory packaging, labeled with manufacturer's density and thickness.

Design & Construction Standards, Revised January

Insulation Board. Knauf Data Sheet PE-DS

Earthwool Redi-Klad 1000 Pipe Insulation

Insulation for VRF/VRV HVAC Systems. Variable Refrigerant Flow(VRF) and Variable Refrigerant Volume(VRV) System Insulation Needs

Thermasheath -3. Insulation for the Building Envelope ROOF WALL SPECIALTY

International Fireproof Technology Inc.

Heat-Shrinkable Tubing

Chilled Water. Product performance for insulation of chilled water piping

Master Specification WALLTITE Eco v.3 by BASF Canada Inc. Section SPRAY POLYURETHANE FOAM INSULATION Page 1

Single-Jacketed Tubing

Aluminum Lagging Roll Jacketing Fittings

Sept 30, 2004 Page 1 PRODUCT DESCRIPTION PRODUCT FEATURES

FIRE STATION 55 June 14, 2010

TSX Insulation for Exposed Use ROOF WALL SPECIALTY

Tel: Fax:

Since Ebrille Industries Group, experience and passion

Knauf Data Sheet PE-DS-2e Insulation Board. with ECOSE Technology

IEEE 1580 Type P MOR Polyrad XT-125 Multi Conductor

DRAFT - MOCA STANDARD for Fiber-Reinforced Magnesium Cement Board

Ammonia. Product performance for insulation of ammonia piping

June 1, 2010 PARTIES INTERESTED IN EVALUATION REPORTS ON REFLECTIVE FOIL INSULATION

OptiLiner Banded Liner System, Thermal, Metal Building

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: THERMAL INSULATION REPORT HOLDER: RHINO LININGS CORPORATION

CERTIFICATIONS AND LISTINGS

(Project Location) (your firm's name)

May 19, 2006 Page 1 PRODUCT DESCRIPTION PRODUCT FEATURES

Thermasheath-XP. Insulation for Exposed Use

SECTION PIPING INSULATION

TECHNICAL BULLETIN POLYISOCYANURATE VS. CELLULAR GLASS IN LOW TEMPERATURE MECHANICAL INSULATION

BuildingName The Description of the Project P DOCUMENTS

University of Delaware

Submittal for Aquatherm Piping System

DSC BUILDING 1200 ALTERATIONS OCTOBER 2011 SECTION DUCT INSULATION

EcoTouch Insulation with PureFiber Technology

Knauf Data Sheet CI-DLS-DS Sonic XP. Duct Liner. with ECOSE Technology

Residential Product Selector Guide

A. Source Limitations: Obtain each type of building insulation through one source.

Fire Protection Products

RTF8510A Base. RTF8510B Curing Agent Color Black Beige Viscosity (cps) 9,000 6,000 Specific Gravity

ENGINEERING COMMITTEE Interface Practices Subcommittee AMERICAN NATIONAL STANDARD. ANSI/SCTE (Formerly IPS SP 100)

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: THERMAL INSULATION SECTION: WATER-RESISTIVE BARRIERS/WEATHER BARRIERS

Highlights of DANA Insulated Sandwich Panels

Gold Bond BRAND Gypsum Sheathing

THERMOFIT ADHESIVE S Flex Fluid Resistant, High Temperature, One Part-Flexible Epoxy

Building Envelope Design using ROXUL (BEDR ) FIREWALL and ROXUL PLUS MB. Fire Rated Board Insulation for Pre-Engineered Metal Buildings

SECTION PERMANENT FORMS Insulating Concrete Forms Rev

MILITARY SPECIFICATION. PLASTIC MOLDING and EXTRUSION MATERIAL, POLYETHERETHERKETONE (PEEK)

July 23, 2010 PARTIES INTERESTED IN REFLECTIVE FOIL INSULATION

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: THERMAL INSULATION REPORT HOLDER: DEMILEC (USA) INC.

K-FLEX K-FLEX ST 74 A NEW GENERATION OF INSULATION MATERIALS

Shrink-Kon Thin Wall Heat Shrinkable Tubing

Earthwool Insulation Board with ECOSE Technology

Closed cell expanded polystyrene (EPS) insulation with graphite.

FM APPROVED. FIRE PERFORMANCE Differences Between Elastomeric and Polyethylene/Polyolefin Insulations

Originally Issued: 05/03/2013 Revised: 06/06/2016 Valid Through: 05/31/2017

Trusted ICC ES DIVISION: ATLANTA, CGF PRO, ENERGYS. Look. Conformity! Evaluation. ICC-ES Evaluation

Custom-Designed Clamps. Machined Versions. Online Configurator for Custom-Designed Clamps A56.

Pipe & Equipment Insulations Product Selection Guide

INTERNATIONAL STANDARD

Air and Vapor Barrier 3015

K-FLEX. K-FLEX Tapes. for HVAC and industrial application

1. Division 23 Section "Hangers and Supports for HVAC Piping and Equipment" for pipe insulation shields and protection saddles.

SECTION REFLECTIVE-FACED, MASONRY CAVITY WALL INSULATION

2. A preconstruction meeting with the TWA s staff is required prior to initiating construction.

Eclipse Air Duct Board

REPORT HOLDER: THE DOW CHEMICAL COMPANY 1501 LARKIN CENTER DRIVE MIDLAND, MICHIGAN EVALUATION SUBJECT:

Mechanical Insulation for Refrigeration Systems

SECTION HVAC INSULATION

ProRox 400 Series. Fabricated Industrial Solutions

REFLECTIVE INSULATION, RADIANT BARRIERS, AND INTERIOR RADIATION CONTROL COATINGS FOR USE IN PRE-ENGINEERED METAL BUILDINGS

Application Specification:

Firestop and Fire Protection Systems

Responsibilities: Effective Date: November Revision Date: January 27, VP, Facilities and Construction Management

American Society of Agricultural and Biological Engineers

FABROCK ROXUL. Versatility and quality customized for you. roxul.com

SECTION HVAC INSULATION

Acoustical Surfaces, Inc.

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: THERMAL INSULATION REPORT HOLDER: NATURAL POLYMERS, LLC


Combustible Exterior Wall Cladding Systems: An ICC Perspective

Cryogenic Pipe Support Systems

TECHNICAL BULLETIN 0214 (update of 0111) PERFORMANCE/COST COMPARISON OF POLYISO vs. XPS PIPE INSULATION SYSTEMS

Reflective Insulation Specification & Application Guide for Post Frame and Metal Building Construction

Short Form Guide Specification. STYROFOAM CAVITYMATE Ultra Air Barrier Wall System

EDITION: EXPORT - PUBLISHED: 11/2013 NEW PRODUCT NAMES. ProRox. Product catalogue. Industrial insulation

First Revision No NFPA [ Section No ]

General Rules for Underground Polyethylene Pipe in Propane Applications:

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: THERMAL INSULATION REPORT HOLDER: DEMILEC (USA) INC.

Thermal Insulation

ROOFS ROOFS WALLS FLOORS. Energy efficiency for constructions... Always environment-friendly...

ESR-2072 Reissued September 1, 2013 This report is subject to renewal September 1, 2015.

THERMOFIT RNF-100 TUBING Polyolefin, Flexible, Heat-Shrinkable

Transcription:

For HVACR Applications Job Name Job Location Engineer Contractor Wholesaler Linesets, Inc. Rep Product Description: Linesets, Inc. Standard and Mini Split Line Sets are available in either an elastomeric, polyethylene or EPDM insulation for use in HVACR applications. All line sets will be manufactured in the United States. Material: Linesets, Inc. Standard and Mini Split Line Sets copper tube shall be made from C12200 grade of copper. is choice of elastomeric, polyethylene or EPDM material. All insulation have a UV retardant added but it is recommended to cover or apply a coating for long term exposure. Key Specifications: Linesets, Inc. Standard and Mini Split Lines Sets are made to meet the requirements of ASTM B1003 and can be used with synthetic refrigerants and sub-critical CO2 systems. Installation: Installations and insulation material shall comply with the latest applicable building codes for the local jurisdiction. MADE IN USA

Copper Tube Data Standard Line Sets with Elastomeric Liquid Line Suction Line Optional Finishes 50 1/4" - 1/2" 1-1/8" 10' - 50' using 5' intervals; 60' & 100' 1-1/2" Flare nuts, 90-degree bends, custom connections, thermostat wire and taping Mini Split Line Sets with Elastomeric Liquid Line Suction Line Optional Finishes 50 1/4" - 3/8" 7/8" 15' - 50' using 5' intervals; 100' 1-1/2" Insulated liquid and suction lines and twin tube system, flare nuts, 90-degree bends, custom connections, mini-split wire or control cable and taping Line Sets with White 50 1/4" - 7/8" 35, 50', 100', 164' 1/2" - 3/4 Line Sets with EPDM Optional Finish 50 1/4" - 1-1/8" 10-50 using 5 intervals 1-1/2 Flare nuts, 90 dergree bends,custom connections, thermostat wire and taping

: R Values Standard and Mini Split Line Sets Elastomeric Data Pipe Size Nom. 3/8" Nom. 1/2" Nom. 3/4" Nom. 1" ASTM C 534, Type II Sheet Grade 1 ASTM C 1534 ASTM E 84, NFPA 255, U L 723 CAN/ULC S102 NFPA 90A, 90B ASTM G21/C1338 ASTM G22 Physical Properties: ASTM D 1056, 2B1 MIL-P-15280J, FORM S MIL-C-3133C (MIL STD 670B), Grade SBE 3 MEA 107-89M UL 181 UL 94 5V-A, V-0, File E 55798 City of Los Angeles RR 7642 Specifications Values Test Method Thermal Conductivity, Btu in./h ft2 F (W/mK) 75 F Mean Temperature (24 C) 90 F Mean Temperature (32 C) 0.25 (0.036) 0.256 (0.037) ASTM C 177 or C 518 Water Vapor Permeability, Perm-in. [Kg/(s m Pa)] 0.05 (0.725 x 10 13) ASTM E 96, Procedure A Flame Spread and Smoke Developed Index through 1 (25mm)* 25/50* Mold Growth Fungi Resistance Bacterial Resistance 1/4" 2.7 3.6 5.6 8.5 3/8" 2.5 3.2 5.4 8.5 1/2" 2.4 3.2 5.2 7.9 5/8" 2.3 3.2 5.2 6.7 3/4" 2.2 3.1 5.1 6.5 7/8" 2.2 3.1 5.0 6.5 1-1/8" 2.1 3 5.4 6.8 UL181 ASTM G21/C1338 ASTM G22 ASTM E 84 CAN/ULC S102 Water Absorption, % by Volume 180/220 F (82/105 C) ASTM C 209 Upper Use Limit 220 F (105 C) Lower Use Limit -297 F (-183 C) Ozone Resistance GOOD Nom. 1-1/2" 14.6 14.6 13.5 12.8 12.1 11.6 10.8

Polyethylene Data : Wall thickness is 1/2-3/4 and product is made according to ASTM C 1427-07 (insulation material for use on typical commercial system non-cross-linked) R Value: 1/2 Wall = R3 3/4 Wall = R5 Description Specifications Notes Water Vapor Permeability ASTM E96-00 r =4*10-5 [mg/(h*m*pa)] Working Temperature ASTM C 1427-07 Type I (tubular), Grade I Surface Burning Characteristics ASTM E84 (25/50) Flame & Spread Index Less Than 25 & Smoke Development Index less than 50 Thermal Conductivity ASTM C 335-95 ISO EN 8497 k at 104 F (average temperature) = 0.263468 (Btu in.)/sq.ft. F h) λ at 40 C (average temperature) = 0.038 W/(m*K) WARNING: This product includes polyethylene (PE) foam insulation. Although this product meets ASTM E84 25/50 flame/smoke index, PE foam insulation may nonetheless be highly flammable when ignited. To reduce the risk of fire spread, property damage, or personal injury, great caution should be exercised when using this product in proximity to any ignition sources or open flames.

: R Values Pipe Size Wall 1-1/2 1/4" 13.7 3/8" 13.7 1/2" 12.7 5/8" 12.0 3/4" 11.3 7/8" 10.8 1-1/8" 10.1 Standard and Mini Split Line Sets EPDM Data ASTM C 534, Type II Sheet Grade 1 ASTM C 1534 ASTM E 84, NFPA 255, U L 723 CAN/ULC S102 NFPA 90A, 90B ASTM G21/C1338 ASTM G22 ASTM D 1056, 2B1 MIL-P-15280J, FORM S MIL-C-3133C (MIL STD 670B), Grade SBE 3 MEA 107-89M UL 181 UL 94 5V-A, V-0, File E 55798 City of Los Angeles RR 7642 Physical Properties: Specifications Values Test Method Thermal Conductivity, Btu in./h ft2 F (W/mK) 75 F Mean Temperature (24 C) 90 F Mean Temperature (32 C) 0.25 (0.036) 0.256 (0.037) ASTM C 177 or C 518 Water Vapor Permeability, Perm-in. [Kg/(s m Pa)] 0.05 (0.725 x 10 13) ASTM E 96, Procedure A Flame Spread and Smoke Developed Index through 1 (25mm)* 25/50* Mold Growth Fungi Resistance Bacterial Resistance UL181 ASTM G21/C1338 ASTM G22 ASTM E 84 CAN/ULC S102 Water Absorption, % by Volume 180/220 F (82/105 C) ASTM C 209 Upper Use Limit 220 F (105 C) Lower Use Limit -297 F (-183 C) Ozone Resistance GOOD