File E56140 Vol. 1 Sec. 15 Page 1 Issued: and Report Revised:

Similar documents
Cannon Trident Connector System

Title: YALE OFFICE OF FACILITIES PROCEDURE MANUAL Chapter: 01 - Yale Design Standard Division: Electrical Standards

Previous Page Return to Index Next Page

SECTION GROUNDING AND BONDING FOR ELECTRONIC SAFETY AND SECURITY

Features 1.34 In Width X 1.53 In Height X 1.13 Recp gang Stainless Steel/304 Stainless Steel

Features SCL-DPDT SCL-DPDT-C1 SCL-DPDT-V SCL-DPDT-S SCL-D-DPDT SCL-D-DPDT-C1 SCL-D-DPDT-V SCL-D-DPDT-S

NARROW PITCH (0.4mm) CONNECTORS P4S SERIES

Featuring. Devices made with CuVerro Antimicrobial Copper Surfaces. EPA registered touch surfaces

SECTION ACCORDION FOLDING PARTITIONS

SPECIFIC TECHNICAL CRITERIA

2/2 % ) Direct Acting Subminiature Solenoid Valves. 1/8" and 1/4" NPT. Features. Construction. Electrical

DESIGN GUIDELINES WIRING AND CONDUITS PAGE 1 of 7

Small-Scale Resistance Welding for Medical and Industrial Applications

SECTION GROUNDING AND BONDING

SECTION HEAT TRACING FOR PLUMBING PIPING

3M Card Connector SD Normal Polarization, Push-Push, Surfacemount SD Series

Distinctive Characteristics

VPL-3200B Residential Vertical Platform Lift Technical Specifications

Welding Processes. Consumable Electrode. Non-Consumable Electrode. High Energy Beam. Fusion Welding Processes. SMAW Shielded Metal Arc Welding

BUSWAY LOW VOLTAGE (POW-R-WAY III) SECTION SECTION 16466

JBS Enterprise Limited. Rm B1, 1/F, Hing Win Industrial Bldg 110 How Ming Street, Kwun Tong Kowloon, Hong Kong Tel: Fax:

PRESTON HEALTH SERVICES ARCHITECT'S NO. 2700

W-P-115C March 14, 1990 SUPERSEDING W-P-115B June 8, 1984 FEDERAL SPECIFICATION PANEL, POWER DISTRIBUTION

SECTION 16496A MTS MANUAL TRANSFER SWITCH (MANUAL CONTROL ONLY) Note to Spec Writer: { } Denotes EATON Feature reference number

This product specification is written according to the Construction Specifications Institute MasterFormat, 2014 Update.

SECTION ACOUSTICAL PANEL CEILINGS

Student Services & Classroom Addition

Welcome to Douglas County PUD

PART MATERIAL REMARK Metal Case with Pig-tail. Brass (Metal Case) Copper (Pig-tail) Star Contact Copper Silver Plated

3BT / 4BT Series Tiny Stat Hermetic Thermostats, -18 C to 177 C, SPST

File E Project June 27, 2014 REPORT. Cabinets and Cutout Boxes. BOCCHIOTTI SPA Milano, MI, Italy

SECTION HANGERS AND SUPPORTS FOR PLUMBING

A. Product Data shall be provided for each type of product indicated.

HANGERS AND SUPPORTS FOR HVAC PIPING AND EQUIPMENT SECTION HANGERS AND SUPPORTS FOR HVAC PIPING AND EQUIPMENT

GENERAL CONTENTS SECTION I - NUCLEAR ISLAND COMPONENTS

Daytona Beach Pier Building Renovation Jun 2010

G. UNDERWRITERS LABORATORY, INC.: 1. UL 325: Electrical Door, Drapery, Gate, Louver, and Window Operators and Systems

2003 International Residential Code ELECTRICAL PROVISIONS ONLY October 2005 EDITORIAL CHANGES SEVENTH PRINTING

NORTH HARRIS COUNTY REGIONAL WATER AUTHORITY PIPE HANGERS, Section PIPE HANGERS, SUPPORTS, AND RESTRAINTS

660 Volts 630 & 800AMP

Chapter 3 Shielded. Metal Arc Welding

Flexible Printed Circuits Design Guide

INDUSTRIAL THERMOMETERS

Westgate Entrematic, Parking Security Gates Section OVERHEAD SECURITY GATE Prepared by: Digicon Information Inc. Page 1

Electrolytic Tinplate

Product Specification JUL 14 Rev. A1

D*MA Connectors

SECTION RADIO FREQUENCY SHIELDING ENCLOSURE RF Welded System

SECTION INFLUENT EQUALIZATION TANK PUMPS

SECTION HANGERS AND SUPPORTS FOR PLUMBING PIPING AND EQUIPMENT

SECTION PACKAGE BOOSTER PUMP STATIONS

HUP. Performance Data. Wholesale Products Page: Section: Performance Data Dated: January RPM: 1550 Discharge: 1" Solids: 1/8" GPM: TDH:

Custom 450 Stainless Steel, UNS S45000

Leadership in Soft Magnetic Alloys

3M PCB Connector.100 Four Row 3400 Series

SURFACE TEMPERATURE SENSORS

Standard Installation Fire Damper Models: 119, 119(F), 119(SS), D19

A. All materials shall be tested and listed by an OSHA approved Nationally Recognized Testing Laboratory (NRTL).

HYDROMATIC W/D/V-A1 SUBMERSIBLE SUMP/EFFLUENT

SPECIFICATIONS - DETAILED PROVISIONS Section Stainless Steel Sluice Gates C O N T E N T S

Outdoor + Switchgear, Walk-in Equipment Buildings Low & Medium Voltage NEMA 3R

ANSI/ ASME HST Performance Standard For Overhead Electric Wire Rope Hoists

PASSAIC COUNTY TECHNICAL INSTITUTE CCA 1422 NEW S.T.E.M. BUILDING 2017

UNIFIED FACILITIES GUIDE SPECIFICATIONS

INDUSTRIAL TEMPERATURE SENSORS

SECTION G RELIEF VENTS A-0

NORTHWESTERN UNIVERSITY PROJECT NAME JOB # ISSUED: 03/29/2017

Cobra. Innovative shielded low profile right angle connector plug and backshell assemblies reduce MIGHTY MOUSE

IMPLEMENTATION RULES FOR COMPULSORY CERTIFICATION OF ELECTRICAL AND ELECTRONIC PRODUCTS

Vinyl Window Designs Ltd. 550 Oakdale Road Toronto, ON M3N 1W6 SPECIFICATIONS

Carbon film resistors

WELDING Topic and Contents Hours Marks

Feb12 Rev D

This guide can be used to prepare a specification for incorporating free standing jib cranes into a competitively bid construction project.

DIVISION 15-MECHANICAL SECTION SUPPORTS AND ANCHORS PN PART 1 - GENERAL 1.01 SECTION INCLUDES. A. Pipe and equipment support systems.

COPPER PRODUCTS. 145 COPPER PRODUCTS Half Hard Tellurium Rounds

Thermocouple for Flue Gas Temperature Measurements,

Insulation for VRF/VRV HVAC Systems. Variable Refrigerant Flow(VRF) and Variable Refrigerant Volume(VRV) System Insulation Needs

SECTION CHAIN-LINK FENCES AND GATES 02821/1

UNIFIED FACILITIES GUIDE SPECIFICATIONS

OVERSHOT GATE TECHNICAL DATA SHEET

( )

Customer Owned Meter Enclosures for Self-Contained Watthour Meters

For the 2008 Code, the minimum clear distances were revised to reflect an accurate metric conversion (also known as a soft conversion).

SECTION HANGERS AND SUPPORTS FOR PLUMBING PIPING AND EQUIPMENT

Reference thermometer Model CTP5000

SELECTION GUIDE Appearance Sensing distance Operation Mode Connector Shape example (M8) Outer diameter (Ferrous material only) Wiring Output Output no

MuShield s High Permeability Magnetic Shielding per ASTM A753 Alloy Type 4

Extruded Aluminum Frame Conveyors

COPPER CABLES AND CONNECTORS (PTY) LTD.

Small Terminals. TEST CURRENT (Amps) Fig 1. Tensile strength of YAD HYLUG after axial rotation stresses. TENSILE STRENGTH IN POUNDS

Standard Model Coolers, Freezers and Combination Cooler/Freezers In Stock for SAME DAY SHIPMENT

Switch Rack Assemblies

Datasheet RS Pro RS Series Axial Carbon Resistor 1kΩ ±5% 2W ppm/ C RS Stock No:

SECTION HANGERS AND SUPPORTS FOR HVAC PIPING AND EQUIPMENT

DISCONTINUED. 3M PC Card Header Dual Slot, Low Profile, Integrated Ejector. Physical. Electrical. Environmental. UL File No.

HD-Swing Series 4000 Heavy Duty Aluminum Swing Door System with Electric Operator

This guide can be used to prepare a specification for incorporating free standing jib cranes into a competitively bid construction project.

heavy mate D Rated voltage 250 V Rated current 10 A A Termination: crimp Number of contacts: 7, 15, 25, 40, 50, 64, 128

UFGS (August 2010) UNIFIED FACILITIES GUIDE SPECIFICATIONS

Transcription:

File E56140 Vol. 1 Sec. 15 Page 1 Issued: 7-2-85 and Report Revised: 9-21-90 D E S C R I P T I O N PRODUCT COVERED: Component - Magnetic Motor Controllers for industrial application. Part No. JZ or JY followed by 4.5 through 48, *may be followed by H, or W, may be followed by E or L, may *be followed by -K, may be followed by -500 through - 999. Part No. JY 101-K GENERAL: This device is a SPST, normally open magnetic Motor Controller for use in industrial applications. RATINGS: Models Coil Contact JY101-K 23.5 V DC 5 A, 30 V DC, 250 V AC resistive 1/8 HP, 125 V AC/ 250 V AC JZ Series 4.5 through 48 V DC See Note JY Series 4.5 through 48 V DC See Note NOTE: See Nomenclature for Contact Rating of JZ and JY Series. NOMENCLATURE: JZ 24 _H E_ -K_ -500 I II III IV V VI NOTE: Part No. may be split and appear on two lines. I. Relay Type JZ Series - Standard Coil power Consumption Type JY Series - Sensitive Coil Power Consumption Type

File E56140 Vol. 1 Sec. 15 Page 2 Issued: 07-02-85 and Report Revised: 04-13-99 II. Coil Voltage III. Contact Rating "JZ" Series - 4.5 through 48 V dc. "JY" Series - 4.5 through 48 V dc. None 3A, 30 V dc/250 V ac Resistive (Rivet Contact) 1/10 HP, 125 V ac/250 V ac D150 pilot duty H 5A, 30 V dc/250 V ac Resistive (Rivet Contact) 1/8 HP, 125 V ac/250 V ac C150 pilot duty * C300 pilot duty A W W(L) 5A, 30 V dc/125 V ac Resistive (Welded Contact) 1/8 hp, 125 V ac/ 250 V ac 5A/250 V ac, Resistive C150 pilot duty 3A 30 V dc/250 V ac Resistive (Bifurcated contacts) 1/10 Hp, 125 ac/250 V ac D150 pilot duty 1 A 24 V dc Resistive (Bifurcated contacts), 0.5 A 125 V ac Resistive (Bifurcated contacts) IV. Indicates Contact Material None E L Silver or Silver alloy. May be Gold Plated. Silver or Silver alloy. Silver-paladium contact maybe overlaid with gold. V. Relay Construction -K Indicates sealed construction.

File E56140 Vol. 1 Sec. 15 *Page 2A Issued: 7-2-85 and Report New: 9-21-90 VI. Indicates minor constructive variation -500 through -999: additional three digits used for special variation of construction as below. A. Variations of coil resistance. B. Variations of pick-up voltage, non pick-up voltage, drop-out voltage, or hold voltage. C. Variations of operating time or release time. Special Part No. JY101-K does not conform with Items II, III and IV of above nomenclature. B. Special Part No. JY 101-K 1. Relay type JY 2. Coil voltage 23.5VDC 3. Contact rating 5A 4. Contact material Ag or Ag alloy contact may be overlaid with Gold 5. Relay construction Sealed construction

File E56140 Vol. 1 Sec. 15 *Page 3 Issued: 7-2-85 and Report Revised: 9-21-90 ENGINEERING CONSIDERATIONS (NOT FOR INSPECTOR USE: Use - For use only in complete equipment where the acceptability of the combination has been determined by Underwriters Laboratories Inc. This component has been judged on the basis of the required spacings from the Standard for Industrial Control Equipment (UL 508) Fourteenth Edition, Paragraph 47.1, which would cover the product if submitted for Unrestricted Listing. Conditions of Acceptability - 1. These devices should be used within Recognized ratings as specified above. 2. These devices should be mounted in the intended manner and in an enclosure having adequate strength and thickness and with acceptable spacings being provided. 3. The terminals are to be factory wired only and the suitability of the connection (including spacings between factory connectors) shall be determined. 4. The spacings from exposed live-metal parts in the enclosure walls shall be in accordance with the requirements of the overall equipment.

File E56140 Vol. 1 Sec. 15 Page 4 Issued: 7-2-85 and Report New: 2-9-89 CONSTRUCTION DETAILS: The product shall be constructed in accordance with the following description. Corrosion Protection - All parts are corrosion resistive material or are plated or painted for corrosion protection. Markings - Recognized Company Name or Trademark and Model number. May also be marked with electrical rating. Spacings - Spacings of not less than 1.6 mm through-air and 3.2 mm oversurface of insulating material (including printed wiring boards) are maintained between any uninsulated live part and and uninsulated live part of opposite polarity, uninsulated ground other than the enclosure, or exposed metal part.

File E56140 Vol. 1 Sec. 15 Page 5 Issued: 07-02-85 and Report Revised: 09-02-98 RELAY, PART NO. JZ24H-K - FIG. 1 (S85-7877) General - The general design, shape, and arrangement shall be as illustrated, except where variations are specifically described. 1. Cover - R/C (QMFZ2). Dimensions 19.4 by 9 by 12 mm, 0.5 mm thick. Manufactured by one of the following: A. G.E. Plastics Japan Ltd., Type 420-SEO B. Dainippon Ink & Chemicals, Inc., Type BT-2230 C. Mitsubishi Engineering-Plastics Corp., Type GSN2020R2, GSV2020R2, GS-2030M or GS-2020M, or Type S-3000. D. General Electric Co., Type 3413 or 3412. E. Teijin Chemicals, Ltd., Type G-3130 or G3120. F. Idemitsu Petro Chemical Co., Ltd., Type G-2530 or G-2520. G. Toray Industries Inc., Type 1184G-30. H. Union Carbide Corp., Type B-322. I. Teijin Ltd., Type CRN7030, minimum 0.32 mm thick. 2. Base Plate - R/C (QMFZ2). Overall dimensions 19 by 9 mm, 0.3 mm thick. Alternate overall dimensions 19.4 by 9.3, 0.3 mm thick. Molded to fit inside cover. Manufactured by one of the following: A. Dainippon Ink & Chemicals Inc., Type BT-2230. B. Mitsubishi Engineering-Plastics Corp., Type GSN2020R2, GSV2020R2, GS-2020. MR2 or GS-2030M or GS-2020M or S-3000. C. General Electric Co., Types 3413 or 3412. D. Teijin Chemicals, Ltd., Type G-3130 or G-3120. E. Idemitsu Petrochemicals, Type G-2530 or G-2520. F. G.E. Plastics Japan Ltd., Type 420-SEO. G. Toray Industries Inc., Type 1184G-30. H. Teijin Ltd., Type CRN7030, minimum 0.32 mm thick.

File E56140 Vol. 1 Sec. 15 Page 6 Issued: 07-02-85 and Report Revised: 07-23-98 3.* Base Mold - R/C (QMFZ2), Mitsubishi Engineering Plastics Corp., Type GSN2020R2, GSV2020R2, GS-2020 MR2; or Mitsubishi Gas Chemical Co., Inc., Type GS-2030M; General Electric Co., Type 3412 or 3413; Teisin Chemicals, Ltd., Type G-3120 or G3130; or Idemitsu Petrochemical Co., Ltd., Type G-2520 or G2530. Overall dimensions 18 by 8.6 by 6.4 mm, 0.32 mm thick. Molded with opening and projections for parts. Alternate overall dimensions 18.5 by 8.8 by 4.6 mm, 0.35 mm thick. 4. Coil Terminals - Copper/zinc/tin alloy or copper/nickel alloy. 15 mm long, 0.32 mm thick. Inserted through base mold, secured by fit. 5. Actuator Card - R/C (QMFZ2), Imperial Chemical Industries, Ltd., Type 520P; or Unitika, Ltd., Type UG-100YY. Approximate overall dimensions 6.5 by 4 by 0.81 mm thick. Secured by fit over Armature. Alternate - Polyarlate, Type LG-1003-10, Unitika Ltd. Same dimensions as above. 6. Armature - Soft iron or steel. Length, 16 mm by 3.5 mm, minimum 0.91 mm thick. Inserted in bobbin, secured by fit. 7. Hinge Spring - Copper/nickel alloy. Rivet to armature. Approximate dimensions 14 mm long, 3 mm wide 0.13 mm thick. Riveted to magnet frame. 8. Magnet Frame and Core - Two-piece construction. Soft iron or steel. Inserted in bobbin, secured by fit. Frame dimensions 11 by 6 by 4 mm, 0.5 mm thick. Molded to overlap pole piece 5.8 mm. Pole piece dimensions 11 by 7 by 4 mm, 0.52 mm thick. Molded to overlap magnet frame 5 mm. 9. Stationary Arm - Beryllium/copper or copper/tin alloy or copper alloy. Shaped as shown. Overall dimensions, 13 by 5 mm, 0.15 mm thick. Secured to insulating block by fit into integrally molded shelf. Alternate - For suffix "A" contacts, see ILL. 1 for details, 0.15 mm thick, 12.2 by 7.8 mm, overall. Contact portion 5.4 mm wide.

File E56140 Vol. 1 Sec. 15 Page 6A Issued: 07-02-85 and Report Revised: 07-23-98 10. Contacts - Silver alloy 0.2 mm thick, gold 0.001 mm thick, copper alloy base 0.2 mm thick. Diameter 2 mm. Models with "E" suffix, silver alloy 0.2 mm thick, copper base. Special Part No. JY 101-K - Copper base overlaid with silver alloy 0.2 mm thick and gold 0.001 mm thick. Alternate Contact - Silver alloy 0.38 mm thick, gold-plated 0.001 mm thick, 2 mm diameter. Models with "E" suffix, silver alloy 0.38 mm thick. Alternate Contacts - Welding type, suffix "A" in nomenclature. Silver alloy 0.2 mm thick, may be cold clad, copper-nickel alloy base. Contacts 0.41 mm thick, 2.2 by 2.4 mm, overall. Welded to contact arms. See ILL. 3 for details. Alternate Contact (Type JZ and JY, 3 A rating only) - Silver 0.38 mm thick, gold-plate 0.001 mm thick, 2 mm diameter. Models with "E" suffix, silver 0.38 mm thick. 11. Moveable Arm - Beryllium/copper or copper/tin alloy or copper alloy. Shaped as shown. Overall dimensions 17.9 by 3.6 mm. 0.15 mm thick. Secured to insulating block by fit into integrally molded shelf. Alternate - For suffix "A" contacts, see ILL. 2 for details, 0.15 mm thick, 6.1 by 17.9 mm, overall contact portion 3.6 mm wide. 12.* Bobbin - Recognized Component - Plastics (QMFZ2), Mitsubishi Engineering Plastics Corp., Type GSN2020R2, GSV2020R2, or GS-2020 MR2. Overall dimensions 19 by 8.7 mm. Alternate overall dimensions 17 by 8 mm. a) Idemitsu Petrochemical Co., Ltd., Type G-2520. b) GE Plastics Japan Ltd., Type 3412, 3412R. c) Teijin Chemicals Ltd., Type G-3120. 13. Coil - Not shown. Polyurethane enameled copper wire.