What is backflow prevention?

Similar documents
CROSS-CONNECTION CONTROL/BACKFLOW PREVENTION

Cross-Connection Control Program

Water Supply System. Plumbing and Cross Connection Control. Cross-Connection. Connection. Plumbing Overview 9/24/

Water Service 39 BACKFLOW PROTECTION

December Illinois American Water Cross Connection Control Program

Module #9: Cross-Connection Control and Backflow Prevention

Milk Pre-Cooler Plumbing Considerations. ATCP 65, Wisconsin Administrative Code and the 2015 PMO

TITLE 64 LEGISLATIVE RULE BUREAU FOR PUBLIC HEALTH SERIES 15 CROSS-CONNECTION CONTROL AND BACKFLOW PREVENTION. use.

Newport Water District CROSS CONNECTION CONTROL PROGRAM

ROCHESTER PUBLIC UTILITIES PUBLIC WATER SYSTEM CROSS-CONNECTION CONTROL AND BACKFLOW PREVENTION PROGRAM FOR ROCHESTER, MINNESOTA

SECTION XIV: BACKFLOW PREVENTION AND CROSS-CONNECTION CONTROL Backflow Prevention & Cross-Connection Control Program Purpose

CROSS-CONNECTION CONTROL PROGRAM OLD TOWN WATER DISTRICT OLD TOWN, MAINE

JACKSON COUNTY WATER AND SEWERAGE AUTHORITY. Cross-Connection Control Program

Backflow Prevention by Containment & Cross-Connection Control Program Easton Suburban Water Authority

TIMBERLAKE IMPROVEMENT DISTRICT Jones Rd, Suite 120, Houston, Texas Phone Number (281)

; WATERMAINS SPECIFICATIONS FOR CROSS CONNECTIONS and BACKFLOW PREVENTION SECTION C5.0

Good Agricultural Practices (GAP) for Fresh Fruit and Vegetable Growers. Water

Cross-Connection Control Program. Manual of Procedures

Wellhead Protection General Guidelines for New Private Domestic Wells

POLICY GOVERNING CROSS CONNECTIONS, AUXILARY INTAKES, BYPASSES, AND INTERCONNECTIONS

Orange County Utilities Cross Connection Control Manual November 2017 Revision 3

Charlotte County Utilities Manual of Rules and Regulations Governing Cross- Connection Control FEBRUARY 2008

BEAU CHÊNE HOMEOWNERS ASSOCIATION, INC. CROSS CONNECTION CONTROL RULE

APPENDIX A INSTALLATION CRITERIA FOR REDUCED PRESSURE PRINCIPLE AND DOUBLE CHECK VALVE BACKFLOW PREVENTION ASSEMBLIES

Backflow Prevention Program Revised:

Needs To Know For Cross-Connection Control System Operators

HALL COUNTY DEPT OF PUBLIC WORKS & UTILITIES Page 1 of 8 Reuse Water End User Application

Backflow Prevention. Ohio EPA Rules Update. RCAP/Ohio AWWA Small Systems Operator Training May 24, 2016

DENR Public Water Supply Section FIGURE 1(A): ALKALINITY VS PH

Whitewater River Region SWMP. APPENDIX L BMPs for Fire Fighting Agency Activities

Annual. Water. Quality. Report. Proudly Presented By: City of Moscow Water Department PWS ID#:

3/7/2016. Safe Water & Ice, Food & Beverage Handling at Golf Courses in Maricopa County. Introduction

Mobile Area Water and Sewer System. Section 6. Cross-Connection and Backflow Prevention Program

Chemigation. in Georgia

CROSS-CONNECTION CONTROL HANDBOOK

APPENDIX G Fire BMPs

BUILDING PERMIT APPLICATION

Coupons. Tips! ODD-EVEN. What s inside. City of Lacey, Washington. for Free Water Saving Items. For keeping hazards out of your drinking water

2015 UPC Chapter 6 Water Systems Part 1 RV

Lawn Sprinkler Agreement To Be Read and Signed by the Homeowner

THE 5Cs WATER HYGIENE TRAINING

ALDERWOOD WATER & WASTEWATER DISTRICT SNOHOMISH COUNTY, WASHINGTON RESOLUTION NO

Well and Septic Standards. Tom McCarty Penn State Extension May 13, 2010

This policy will generally explain the following in regards to the City sewerage collection systems:

The Ocean Begins at Your Front Door

PREMISE ISOLATION CROSS-CONNECTION CONTROL PROGRAM

CROSS-CONNECTION CONTROL HANDBOOK

Your recycled water guide

Cost Analysis of Cross-Connection Control Management

Water Safety: Protecting Our Communities from Backflow Incidents

Every drop counts. ACEEE Hot Water Forum June 9, 2009

[ Graywater has the same meaning as gray water, grey water and greywater.]

Module 6 Shock Chlorination. For more information refer to the Water Wells That Last video (Part III Shock Chlorination).

Mains Water System Regulations

A Guide for Drinking Water System Owners Seeking To Undertake a Backflow Prevention Program

D EPARTMENT OF W ATER MANAGEMENT

Perspectives on prioritizing microbial hazards and quantifying risks for produce safety. Jeffrey Soller Water Summit February 27, 2018

Educational Course Application

STANDARDS FOR BACKFLOW PREVENTION ASSEMBLIES

COWETA COUNTY WATER AND SEWERAGE AUTHORITY BACKFLOW PREVENTION BY CONTAINMENT POLICY AND PROCEDURE

Virginia Department of Health Office of Drinking Water

WARWICK TOWNSHIP Dept. of Planning & Zoning

Water Supply Corporation here by adopts the following regulations and restrictions on the delivery and consumption of water.

DROUGHT MANAGEMENT AND WATER CONSERVATION IN CHARLOTTESVILLE AND ALBEMARLE COUNTY

Recommended Amendments to the 2015 International Plumbing Code North Central Texas Council of Governments Region

11.0 HANDLING AND STORING AGRICULTURAL INPUTS

Amendments to the 2006 International Plumbing Code

The effects of pollution. What is stormwater runoff? Why is stormwater runoff a problem?

Middlesex Water Authority

Permit Application. Building - Electrical - Mechanical - Plumbing - Sign. Project Address: Building and Safety Permit Service Center

GRAY WATER SYSTEMS (Reference California Plumbing Code Chapter 16 and 16A) Revised: 6/11/14

D E P A R T M E N T O F WATER MANAGEM E N T

Bloomington Township Public Water District User Information Packet. Water Service

San Francisco s Onsite Water Systems. Paula Kehoe Director of Water Resources San Francisco Public Utilities Commission February 25, 2015

BUILDING FOR OUR FUTURE

Water Quality Testing II:

CHAPTER 6 WATER SUPPLY AND DISTRIBUTION

Fort Collins - Loveland Water District. Cross-Connection Control Manual

INDIAN HILLS UTILITY OPERATING COMPANY, INC. CUSTOMER RIGHTS AND RESPONSIBILITIES

The EN 1717 standard in a glance

Amendments to the 2012 International Plumbing Code

ARTICLE 10 WATER SHORTAGE CONTINGENCY PLAN 90

Some people get most of their water from their own

Annual. Reporting Year Presented By MCAS Cherry Point PWS ID#:

Streamlining Regulations: San Francisco s Non-potable Water Program

Glossary Irrigation Terminology

Outlines for Water Saving Practices in Kuwait

SECTION 620 CROSS CONNECTION CONTROL

Appendix B. Sanitation Performance Standards

2014 White Earth Drinking Water Report

Chapter 2. Editor. Ted W. van der Gulik, P.Eng. Senior Engineer. Authors. Stephanie Tam, P.Eng. Water Management Engineer

Element D Services Plumbing

Good Agricultural Practices & Good Handling Practices Program. Water Quality Issues Frequently Asked Questions (FAQs)

City s position on installation of alternative water systems. Sarah Rushmere and Winston MacKay November 2017

WATER SUPPLY AND DISTRIBUTION

RÈGLEMENT REGARDING THE USE OF DRINKING WATER. the Municipality exploits six drinking water networks;

REQUIREMENTS. (919) REV 02/01/2017 1

WATER SUPPLY AND DISTRIBUTION

Best Management Practice (BMP) Water Quality Protection Guideline Commercial Landscaping and Lawn Care Services. Section 1.

Building Permit Fee Schedule For Calendar Years

Transcription:

What is backflow prevention? Protection of the public and private water supplies through containment and isolation. Backflow occurs whenever water flows in the opposite direction or reverse of the intended direction.

What do the following piping systems have in common? Portable Pressure Washers Sprayer Hose Attachments Garden Hoses Radiator Flush Kits Fire Sprinklers Cooling & Heating Systems Utility Sinks Swimming Pools Hot Tubs Solar Systems Spas Lawn Irrigation Systems

Answer: Each of these water piping systems are cross connections which provide a means for potentially contaminated water and other materials to backflow into the drinking water system.

Backflow occurs whenever water flows in the opposite direction or reverse of the intended direction.

Examples: Suppose that a portable pressure washer is attached to a household faucet. The washer can create a greater pressure than the water main supplying the house. If this scenario occurs, contaminants from the pressure washer, such as solvents, grease, or detergents, could backflow into the drinking water system. There are other ways that backflow can harm the water supply. For example, pesticides and fertilizers could be back-siphoned from a hose spray attachment if the water pressure in the main water line is reduced due to a main break, scheduled shut-off, during the event of a fire where a fire truck draws a significant amount of water from the system, or a fire hydrant is opened for maintenance.

Life Health and Safety If backflow occurs and contaminants enter the water system, people s health and lives are at risk.

Prevention: To prevent this potentially hazardous event from occurring, the City of Corpus Christi has established a state-mandated cross connection control program. Under this program, backflow prevention assemblies must be installed on all water-using systems and equipment which makes a cross connection between safe drinking water and potential contaminants. Since there are a variety of backflow prevention assemblies on the market, feel free to check with the City s Backflow Prevention Program staff before selecting and installing such a device.

Obtaining a Permit: Before installing a backflow prevention assembly, obtain a permit from the City of Corpus Christi. After obtaining a permit, have a Certified Tester test the assembly (the City has a list of registered testing agencies available on this website) and finally call the City for an inspection.

Annual Testing: Each assembly is required to be tested upon installation and then annually. A list of State licensed, City registered testers is available in a PDF file on our website ( www.cctexas.com ).

Lawn irrigation systems Why Having a Lawn Sprinkler System Tested is Important Backflow events are a major source of waterborne disease. From 1981 to 1998, the Center for Disease Control (CDC) documented 57 waterborne outbreaks related to crossconnections, resulting in 9,734 detected and reported illnesses. From May 2002 to January 2003, the University of California studied 400 homes. Homes with a cross connection health hazard constituted 95.7% of the homes. 73% of all water uses were through unprotected cross connections.

DEFINITIONS POTABLE WATER: Water that is satisfactory for drinking, culinary and domestic purposes. BACKFLOW: The undesirable reversal of flow of water or mixtures of water and other liquids, gas, steam or other substances into the distribution pipes of the potable supply or water from any source or sources. CROSS-CONNECTION: Any physical connection or arrangement between two otherwise separate piping systems, one of which contains potable water and the other, water of unknown or questionable safety, steam, gas or chemical, whereby there exist the possibility for flow from one system to the other, with the direction of flow depending on the pressure differential between the two systems. BACKFLOW PREVENTION ASSEMBLY: Any approved effective assembly used to prevent backflow into a potable water supply system. The type of assembly used shall be based on the existing or potential degree of hazard, and backflow condition. AIR GAP: a separation between any pipe or faucet conveying water and the flood-level rim of any plumbing receptacle.

Cross Connection Examples

Backflow prevention assemblies

We all need to do our part to protect and preserve our clean water.