EXPERIMENT 5 Chemistry 110 COMPOSITION OF A MIXTURE

Similar documents
Copper Odyssey. Chemical Reactions of Copper

CHEM 1215 LAB NOTES EXPT #2: PHYSICAL AND CHEMICAL CHANGES 1

DETERMINATION of the EMPIRICAL FORMULA

To identify and classify various types of chemical reactions.

Skills in Science. Lab equipment. (Always draw 2D) Drawings below are NOT to scale. Beaker - A general purpose container with a pouring lip.

EMPIRICAL FORMULA OF MAGNESIUM OXIDE

EMPIRICAL FORMULA OF MAGNESIUM OXIDE

Preparation of copper(ii) sulfate from copper(ii) nitrate

TYPES OF CHEMICAL REACTIONS PART I INTRODUCTION

IDENTIFYING UNKNOWN SUBSTANCES

Gravimetric Analysis: Determination of % Sulfur in Fertilizer

Experiment. Molar Mass of an Unknown Sulfate Salt by Gravimetric Techniques 1

GRAVIMETRIC DETERMINATION OF SULFATE IN AN UNKNOWN SOLUTION

Chapter 8. Gravimetric Analysis

solvent diffusion dissolving soluble

Recrystallization with a Single Solvent

2. Crystallization. A. Background

EMP I RICAL FORMULA OF MAGNESI U M OXIDE

H N 2. Decolorizing carbon O. O Acetanilide

Copper Smelting by an Ancient Method

Pre-Lab Exercises Lab 8: Biochemistry

EXPERIMENT 3: Identification of a Substance by Physical Properties

Elemental Mass Percent and Empirical Formula From Decomposition of a Copper Oxide

Experiment 13: Determination of Molecular Weight by Freezing Point Depression

(aq) + 5e - Mn 2+ (aq) + 4H 2

TITANIUM DIOXIDE. SYNONYMS Titania; CI Pigment white 6; CI (1975) No ; INS No. 171 DEFINITION DESCRIPTION FUNCTIONAL USES CHARACTERISTICS

An Oxidation-Reduction Titration: The Reaction of Fe 2+ and Ce 4+

Total Dissolved Solids

Salinity in Seawater

Determination of the Empirical Formula of Magnesium Oxide

Mon. Tues. Wed. Thurs. Fri. AM or PM B

Periodic Properties: Analysis of Group I, II and Transition Metals

Analysis of Calcium Carbonate Tablets

Name Honors Chemistry / /

Evaluation copy. Total Dissolved Solids. Computer INTRODUCTION

Episode 608: Latent heat

Experiment 2: Preparation of the Artificial Sweetener Dulcin

TESTING THE WATERS HOW GOOD IS THAT BOTTLED WATER AND HOW EFFECTIVE IS YOUR WATER FILTER

The Copper Group. The Separation of the Copper Group:

Partner: Cathy 22 March Separation and Qualitative Determination of Cations and Anions

CH241 Experiment #1 (Weeks of September 11, 18, and 25, 2017)

Teknik Bioseparasi. Dina Wahyu. Genap/ Maret 2014

LAD B3 (pg! 1 of 6! ) Analysis by Redox Titration Name Per

CRHS Academic Chemistry Unit 1 Matter and Change HOMEWORK. Due Date Assignment On-Time (100) Late (70)

1. Marie mixed 5 g of carbon with 5 g of lead oxide. She heated the mixture strongly for 15 minutes in a fume cupboard.

The Crystal Forest Favorite Holiday Demonstrations

Nickel Electroplating

Experiment: Preparation of Adipic Acid by Oxidative Cleavage of Cyclohexene

Lab #3: Law of Definite Proportions

Experiment 2: The Chromatography of Organic Compounds

» Talc is a native, hydrous magnesium silicate, sometimes containing a small proportion of aluminum silicate.

Forensics with TI-Nspire Technology

Core Lab: Energy Changes During Melting and Evaporation

Part A (Level 1) A Matching (4 marks, 1 mark each) B Multiple-choice questions (20 marks, 2 marks each) Name: ( ) Time and Marks Class: Date:

Experiment 3: The Chromatography of Organic Compounds

Lab 2: Determination of the empirical formula of the product of magnesium heating

CRHS Academic Chemistry Unit 1 Matter and Change HOMEWORK. Due Date Assignment On-Time (100) Late (70)

Group IV and V Qualitative Analysis

Principles and Practice of Agarose Gel Electrophoresis

EXPERIMENT 6. Determination of the Ideal Gas Law Constant - R. Magnesium metal reacts with hydrochloric acid according to the following reaction,

Chem 2115 Experiment #9. Consumer Chemistry: Determining the Iron Content in Supplements

CONSERVATION OF MATTER AND CHEMICAL PROPERTIES

Principles of Gel Filtration Chromatography

Lab 4B: Moles of Iron & Copper

Principles of Gel Filtration Chromatography

EXTRA CREDIT - EXPERIMENT G ELECTROCHEMISTRY ACTIVITY OF METALS

7. Determination of Melting Points

Porosity of Compost Water retention capacity of Compost Organic matter content of Compost Buffering capacity of Compost

Experiment 1: The Densities of Liquids and Solids (from Masterson & Hurley)

Measuring Manganese Concentration Using Spectrophotometry

Tex-239-F, Asphalt Release Agent

Analysis of Alum, AlK(SO 4 ) 2 12H 2 O AP Chemistry Laboratory #2

USEPA Membrane Filtration Method Method m-tec. Scope and Application: For potable water, nonpotable water, recreation water and wastewater.

Assistant Lecturer. Sahar Mohammed Shakir Assistant Lecturer. Abdul Hafeedh Hameed Assistant Lecturer. Ali Basim

Eutrophication Using Up Oxygen In Water

TECHNICAL GRADE MOLYBDENUM OXIDE

M. It is expressed in units such a g/cc,

crystallization melting individual molecules crystal lattice

ENGI Environmental Laboratory. Lab #2. Solids Determination. Faculty of Engineering & Applied Science

The determination of copper in brass

Experimental techniques

Name Lab Section Date. Sediment Lab

Laser ACB 50 Product Code: Revised Date: 03/17/2009. Laser ACB 50

Human DNA Alu Amplification by Polymerase Chain Reaction (PCR)* Laboratory Procedure

The 2017 Wisconsin Crystal Growing Competition Handbook

Research Paper On The Comparison Of The LDH Isoenzymes From Scuds From Two Different Geographic Locations

PHASE CHANGES. Time Temperature Observations. Name(s)

Year 7 Chemistry HW Questions

Soil Particle Density Protocol

EXPERIMENT 5. Molecular Absorption Spectroscopy: Determination of Iron with 1,10-Phenanthroline

YEAR 7 SCIENCE EXAMINATION. Semester MULTIPLE CHOICE QUESTION BOOK 1 MATERIAL REQUIRED / RECOMMENDED FOR THIS PAPER:

The Aluminum Group. Separation of the Aluminum Group from all others

ALTERNATIVE TRANSPORTATION FUELS LAB

Experiment 30A ENERGY CONTENT OF FUELS

The table below shows some of the properties of the elements cobalt and nickel.

, to form the products magnesium oxide, MgO(s), and magnesium nitride, Mg 3

SPECTROPHOTOMETRIC DETERMINATION OF IRON

By Authority Of THE UNITED STATES OF AMERICA Legally Binding Document

Pre-Lab 5: Magnesium and Magnesium Oxide

Spectrophotometry of DNA and RNA

Transcription:

EXPERIMENT 5 Chemistry 110 PURPOSE: The purpose of this experiment is to determine the percent composition of a mixture. COMPOSITION OF A MIXTURE Most matter is a mixture of many substances. For example, crude oil is a mixture. Most of the foods we eat are mixtures. Often it is a mixture of many different compounds of varying molecular mass. It is separated into its component parts such as gasoline and lubricant oil by utilizing the differing physical properties, in this case boiling point. Most mixtures can be separated by physical change In today s experiment you will determine the percent composition by mass of a sand (SiO 2 ) and Copper (II) sulfate (CuSO4)mixture. It will require separation by physical means. You will use the differences in water solubility to separate the two substances. Sand (SiO 2 ) is insoluble in water whereas copper (II) sulfate is water soluble. When water is added to the mixture, the sand will not dissolve, but the copper (II) sulfate will. Then, the sand will be dried. In this way, you will separate sand from the original mixture. Safety goggles must be worn at all times PROCEDURE 1. Weigh a clean dry (empty) evaporating dish to the nearest 0.01 of a gram. Record the mass below. 2. Obtain an unknown from your instructor. Weigh the unknown mixture in the evaporating dish. Record the exact mass to the nearest 0.01 g. Make some visual observations about your mixture: DATA Mass, grams Evaporating Dish Evaporating Dish plus Unknown mixture 3. Carefully, transfer the entire unknown sample into a 400 ml beaker. DO NOT PUT ANY EXCESS CHEMICALS BACK INTO THE REAGENT BOTTLES. 4. Obtain approximately 200 ml of de-ionized water. Pour, with stirring, the water into the beaker. If after stirring for a few minutes there is still solid CuSO4, add 25 ml more water. Make sure all of the copper (II) sulfate is dissolved. 5. Allow the sand to settle, then carefully decant the liquid into a 250 ml beaker. See "How to decant " on the next page. This can be done at your bench. Discard the liquid in the beaker if there was no sand loss. 6. Add about 50 ml of deionized water with stirring to wash the sand. Allow the sand to settle and then decant the wash water into the 150 ml beaker. 1 1/9/2018

HOW TO DECANT glass stirring rod Decanting means to let the solid settle to the bottom of the beaker. Then, carefully pour off the top liquid layer. Hold a glass stirring rod on top of the beaker to guide the stream of liquid down into another beaker. 7. Repeat step 6 with another 50 ml portion of deionized water. (This is to remove the CuSO4). What color should the liquid be if all of the CuSO4has been removed? 8. What should you do if you think that some CuSO4 still remains in the sand? 8. Transfer all the sand to the evaporating dish with a rubber policeman. Use a stream of deionized water to transfer the last particles of sand. Decant the water used in transferring. Use a medicine dropper to draw off as much of the remaining water as possible without removing any of the sand. 9. Prepare a steam bath using your 250 ml beaker. Set-up a ring stand with an iron ring. Place your wire gauze on top of the iron ring. Add tap water to a 250 ml beaker until it is about 2/3 full and then warm the water using a Bunsen burner. Dry the sand by heating the wet sand in the evaporating dish over the steam bath. evaporating dish Wire gauze Iron ring evaporating dish tongs NOTE: Use the evaporating dish tongs (located in the long vertical locker at your lab bench) to handle the hot evaporating dish. 2 1/9/2018

10. Stir the sand when it looks dry to check for dampness. If the sand still appears dry, remove it, dry the bottom of the dish, and allow it to cool on the base of your ring stand. Weigh the evaporating dish and sand. Record to the mass to + 0.01 g. 11. Reheat the sand for another 5 minutes. Cool and weigh as above. Repeat this process until you have Dried to Constant Mass (see below). Two weighings must be within + 0.2 grams. DRY TO CONSTANT MASS You cannot tell by looking at the sand whether or not the sand is really dry. You must heat the sand, weigh it, reheat, and then, reweigh the sand. The heating and weighing process is continued until two consecutive weighings are fairly close. This process is called Drying to Constant Mass. This is the only way to know if all of the water has been driven off! DATA Use the lowest value obtained to calculate the mass of your sand. 1st Weighing Mass of Evaporating Dish plus Sand 2nd Weighing 3rd Weighing 12. After you have calculated your percent sand and obtained the correct value, dispose of your sand. (If your experimental value is too high your instructor will ask you to reheat and reweigh your sand). * DISPOSAL: Dispose the sand in the waste container labeled "Waste Sand CALCULATIONS 1. Calculate the mass of unknown sample. 2. Calculate the mass of sand. 3. Calculate the mass of copper (II) sulfate, CuSO4. 3 1/9/2018

4. Calculate the percentage (by weight) of sand in the sample. Write this on your report sheet. Then, ask your instructor for the correct sand. (Do this after you calculate your % Sand). Accepted value from instructor 5. Calculate the percent error. 6. Calculate the percentage (by weight) of copper (II) sulfate, CuSO4, in the sample. % Error 4 1/9/2018

Chem. 110 Lab Report Name Lab Section EXPERIMENT 5 Date Initials COMPOSITION OF A MIXTURE CALCULATIONS: Show all set-ups. 1. Calculate the mass of unknown sample. 2. Calculate the mass of sand. 3. Calculate the mass of copper (II) sulfate, CuSO4. 4. Calculate the percentage (by weight) of sand in the sample. Correct % Sand (From Instructor) 5. Ask your instructor for the correct percent sand (take your report sheet). Calculate the percent error. 6. Calculate the percentage (by weight) of copper (II) sulfate, CuSO4, in the sample. % Error QUESTIONS AND PROBLEMS 1. Give a reason why (other than calculations) your percentage of sand might be lower than the correct value. 5 1/9/2018

2. Give a reason why (other than calculations) your percentage of sand might be higher than the correct value. 3. A mixture of KCl and SiO 2 weighed 4.23 g. The KCl was dissolved in water and then the solution was decanted and dried leaving only 2.76 g of dry sand. Calculate the percent sand in the sample. Set-up: 4. What are 2 ways that a mixture of sand and CuSO4 is different from a compound like K 2 CO 3 1) 2) 6 1/9/2018