MPM 100 Monitor Product Description Guide

Similar documents
HOBO Plug Load Logger (UX ) Manual

2000 User/ Installer Guide

Temperature Controllers: JC Series Digital Indicating Controllers. JC Series. High Performance Controllers...at the lowest prices anywhere!

User Manual. Network Pro Series Tower and Rack-Mount Convertible UPS. Table of Contents 1000/1500/2200/3000

Imperial Series. Model IMP-425/525/625/825/1000AP IMD-425/525/625/825/1000AP IMP-1025/1200/1500/2000AP IMD-1025/1200/1500/2000AP

FAST POWER FACTOR REGULATOR. Computer-14df - xx - 144a INSTRUCTION MANUAL ( M / 00A ) (c) CIRCUTOR S.A.

7700 TEST KIT OPERATIONS MANUAL

SABRE P MODEL PD603 PROCESS METER Instruction Manual

Data Logging Solutions from Lascar Electronics

COLow COHigh COLow/H 2 NO 2 CO 2 H 2 S SO 2 C X H Y LANCOM 4. Portable Flue Gas Monitoring. comp NO NOx

enterprise security data sheet VYKON Form a secure integrated ecosystem

Agilent 4339B/4349B High Resistance Meters Technical Overview

SC-6104-W5 User Manual

Fluke Oscilloscope Calibration Solutions. Helping you measure up to the highest standards

JENEsys Security. data sheet. Form a secure integrated ecosystem

Model 3185E DUAL TONE DECODER INSTRUCTION MANUAL

RT5kVA and RT6kVA 3U Rack or Tower Uninterruptible Power Supplies Product Guide

COLow COHigh COLow/H comp NO NOx NO2 CO2 H2S SO2 CXHY LANCOM 4. Portable Flue Gas Monitoring.

Using the PPM2 Portable Trace Moisture Transmitter

Door Control Unit (DCU)

Daker DK kva. Parallel installation quick start. Part. LE08927AA-09/15-01 GF

Inscale Measurement Technology Ltd Tel: Fax:

LIEBERT Nfinity UPS. GUIDE SPECIFICATIONS for a 4 to 16 KVA (208/120V or 240/120V) Single - Phase Uninterruptible Power Supply System 1.

Powerware 9120 UPS. Date: Issued By: Product Affected May 27, 2003 Gary Bankay PowerFlex 7000 MV Drive

XSTi Standby UPS. 400VA, 600VA, 800VA Models. User & Installation Manual

Wireless Freezer Manual Installation Guide

CEM500-L. Online Gas Analyser. Specialist Of UV Spectroscopy

Technical System Catalogue Modular PDU (PSM)

RESTORE 1030TM Testing Protocol

TrueSense* for Cooling

POWER FACTOR REGULATOR. Computer-12e-xx INSTRUCTION MANUAL ( M / 02A ) (c) CIRCUTOR S.A.

SIWAREX FTC-B Weighing Module for Belt Scales Set-up of SIWAREX FTC with SIWATOOL FTC_B

WP200e Wallbox to CD Changer Adapter

Measurement & Analytics Measurement made easy. AlSCAN TM and AlSCAN TM Argon Hydrogen analysis in liquid aluminum

BX-895 REAL TIME MODULE OPERATION MANUAL

Sageon Site Monitor (SSM) Application Note

Plan Your Monitoring. System Planning Overview

C60 Standby UPS. 800VA Models. User & Installation Manual Xtreme Power Conversion Corporation. All rights reserved.

4Ch Real time / Duplex LCD Combo DVR

Programmable Device Server User Manual

SCUtils Monitoring APC UPS Guide Solution for Microsoft System Center 2012 R2/2016 Operations Manager

RapID Raw Materials Verification System

NovaWAVE. A new category of Automated Microwave Digestion

Water purification in the pharmaceutical industry

INSTALLATION MANUAL AND OPERATING INSTRUCTIONS

MNL, SEL DIMENSIONS, SITE AW PLANNING GUIDE ARTWORK SIZE A SHEET 1 OF 1

Three Relays, 1-8 Temperature/Humidity Sensors 7-Day Programmable Web-Enabled Thermostat

Remote AMD Operator Manual

INSOMNIAC 900 Contractor's Guide

MJK Automation YOUR PARTNER FOR WATER PROCESSING INSTRUMENTATION BROCHURE EN 1.00 PRODUCT BROCHURE 1401

8 stream capability with dual mode (H 2 S & total Sulphur)

PRESENTS A RFID THE JANUS* GATE: RFID TERMINAL SYSTEM FOR CONTAINERS CCCCCONTAINERS CONTAINERS RFID NEPTUNESEAL * CONTAINER BOLT SEAL

AS950 ALL-WEATHER REFRIGERATED SAMPLER

OWNER'S OPERATING MANUAL

System Planning Guide

INSTALLATION MANUAL AND OPERATING INSTRUCTIONS

Instruction Manual. for. gskin U-Value Kit

Freelance 800F The compact control system

PDM16 & PDM32 User Manual

Sentinel LNG. Panametrics Ultrasonic Flowmeter for Cryogenic Liquids. GE Sensing & Inspection Technologies. Benefits. Applications

Shur-Shot X-Proof Hydrogen Fluoride Alarm Operations Manual

HiSeqTM 2000 Sequencing System

Product Datasheet July Liquid Ultrasonic Flow Meters. Daniel 3812 Liquid Ultrasonic Flow Meter

3 PHASE ENERGY ELECTRONIC METERS MKB-363-M INSTRUCTION MANUAL ( M / 00 B

This Specification Data Sheet brought to you by: Trinity Blvd. Fort Worth, Texas /

Non-Contact Temperature Measurement

INSTALLATION MANUAL AND OPERATING INSTRUCTIONS

Agilent E1345A 16-Channel Low-Offset Relay Multiplexer. Data Sheet. Agilent Technologies. Description. Configuration.

Asset Management. Visit us at: or call SCAN

Eurotherm. Temperature Control, Measurement and Data Recording Solutions. Product Selection guide

INFORS HT Product Guide: Visiferm DO Optical Oxygen Sensor

INSTALLATION MANUAL AND OPERATING INSTRUCTIONS

Long-Range Reader/Writer

Reinventing Leak Test

Pallet Safe: Installation Supplement Rev

Container Weight System. Ensure SOLAS compliance for container weight verification with Strainstall s highly accurate CWS for ports and terminals

IDS 1632 Installer Manual K Issued September 2009

GE Energy Aggregator. Cost allocation for multiple sites

Using UPSMON-PRO Monitoring Software. Opening UPSMON-PRO Monitoring Software

EXM UPS 80kW - 200kW Efficient and Flexible Power-Optimized For Medium-Size UPS Applications

Instruction Manual. for. gskin U-Value Kit

APC Smart-UPS VT, w/parallel Operation Guide Specification for 10kVA to 40kVA 3 400/ V Solutions Uninterrupted Power Supply

Isco EZ TOC. TOC and TC Analysis Made Easy. Continuous on-line TOC/TC measurement using low-temperature oxidation

LANCOM4 PORTABLE FLUE GAS MONITORING. NO NO2 NOx CO2 H2S SO2 CxHy. CO low CO high O 2 QUALITY CUSTOMER SOLUTIONS


Aistin IoT Starter Kit

2.8 ( Access Level 3-4)

FTW 175 Wireless Monitoring System Reference Manual Part Number

Stopwatch Display Timer Owner s Manual

UV400 LINE WATER ANALYSER TETHYS INSTRUMENTS 57, CHEMIN DU VIEUX CHÊNE, MEYLAN -FRANCE-

INSTALLATION MANUAL AND OPERATING INSTRUCTIONS

Model: LI55 DataView Level Controller Instruction Manual

Instruction Manual. gskin U-Value Kit. for. 1 / 7 gskin U-Value KIT: Instruction Manual. Status: 28 th October greenteg AG Technoparkstrasse 1

Process & Temperature Panel Meter APM765 Instruction Manual

WasteMan 2G. Key Features. Newcastle Weighing Services Pty Ltd. Prepared by. Office: (02) Fax: (02)

INSTALLATION MANUAL AND OPERATING INSTRUCTIONS

Chloride/Sulfate Analyzer

FAG WiPro. Wind Turbine Protection

Building Security Worldwide. Enterprise Security Management System

EPS /625/750/800/1,000/1,100 kva Performance power protection for critical applications. schneider-electric.com

Transcription:

MPM 100 Monitor Product Description Guide 3103 No. Andrews Ave. Ext. Pompano Beach, FL 33064 Tel: (954) 623 6660 Fax: (954) 623 6671 www.alber.com 4200 062 Rev 2.01

Copyright and Disclaimer MPM 100 Product Description Guide Document Revision 2.01 Part Number 4200 062 Revision History Revision Date of Change Description of Change By 2.00 11/04/2004 Original Document ED 2.01 01/26/2012 Minor edits and reformatting and pagination MS Albér MPM-100 Product Description Guide Part Number 4200 062 2012 Albércorp. All rights reserved. Albércorp, 3103 North Andrews Avenue Extension, Pompano Beach FL 33064. No part of this document may be reproduced or transmitted in any form or by any means, electronic or mechanical, including photocopying and recording for any purpose, without the express written permission of Albércorp. Information in this document is subject to change without notice. Trademarks The first instances of registered trademarks or trademarks of Albércorp and other companies are annotated above using the and symbols. For ease of reading, these symbols do not appear in the remainder of this Product Description Guide. Printed in the United States of America. 4200 062 2 Revision 2.01

Table of Contents 1. MPM 100 GENERAL DESCRIPTION... 1 1.1. Normal Operating Mode... 1 1.2. Discharge Mode... 1 1.3. Resistance Test Mode... 1 1.4. Alarm Features... 1 1.5. Controlled Run Down Test... 2 1.6. MPM-100 Features... 2 1.7. Battery Monitor Data Manager (BMDM) Program Features... 2 1.8. Optional and additional Accessories... 3 2. PANEL CONTROLS AND INDICATORS... 5 2.1. Panel Controls and Indicators... 5 3. MPM-100 CONFIGURATIONS... 8 3.1. MPM Model Number Description... 8 3.2. MPM Configuration Options... 9 4. MPM-100 SPECIFICATIONS... 11 4.1. Fuses On PC Board (Not user replaceable)... 11 4.2. Measurement Range/Inputs... 11 5. COMMUNICATION OPTIONS... 13 Drawings IMPORTANT NOTE: The drawings in this manual may not be the most recent revision and are included for reference only. Refer to the Engineering Drawing Package included with your system for the newest drawings. Drawings in this manual may be for reference only or superseded by later drawings. For the latest information, refer to the drawings supplied with your system. General Assembly BDS 154 B557 Table of Figures Figure 1. Shunt/Shunt Adapters... 3 Figure 2. Ambient Temperature Probe 2900 029... 3 Figure 3. Electrolyte Temperature Probe 2900 010... 3 Figure 4. External network interface... 4 Figure 5. 600 amp Current Transducer (CT)... 4 Figure 6. Multitel Float Charging Current Probe Kit... 4 Figure 7. Rear Panel with RJ45... 5 Figure 8. Rear Panel with RS 232... 5 Figure 9. Front Panel... 5 Figure 10. Front Panel Indicators Close up... 6 Figure 11. Front Panel Connector and Controls... 6 Figure 12. Rear Panel Connectors... 7 Figure 13. MPM 12V Systems Configuration Options Chart... 9 Figure 14. MPM 24V - 36V Systems Configuration Options Chart... 10 Figure 15. MPM 38V - 60V Systems Configuration Options Chart... 10 Figure 16. MPM 60V - 120V Systems Configuration Options Chart... 11 Figure 17. MPM Model Number Communication Option A... 13 4200 062 3 Revision 2.01

Figure 18. MPM Model Number Communication Option B... 13 Figure 19. MPM Model Number Communication Option C... 14 Figure 20. MPM Model Number Communication Option D... 14 Figure 21. MPM Model Number Communication Option E... 15 Figure 22. MPM Model Number Communication Option F... 15 Figure 23. MPM Model Number Communication Option G... 16 Figure 24. MPM Model Number Communication Option H... 16 Figure 25. MPM Model Number Communication Option J... 17 Figure 26. MPM Model Number Communication Option K... 17 Figure 27. MPM Model Number Communication Option L... 18 4200 062 4 Revision 2.01

1. MPM 100 General Description The MPM 100 is a stand alone monitor for communication and power industry applications. What sets Albér monitors apart from others is their ability to provide early warning of battery problems. The monitor checks the state of health of each cell by performing a proactive resistance test, a reliable predictor of battery performance. In addition, to indicate immediate battery health and monitor status of a given location, the system reports to a Central computer (a generic PC) displaying status screens. Using polling and data transfer algorithms, the Battery Monitor Data Manager program lets a Central computer manage over 1000 monitor systems. Data is stored in the computer database for later analysis and reporting. At any time, service personnel may call a battery location from the Central computer or a remote location (such as from home), or directly connect to the monitor without losing contact with the computer. The Data Manager string and monitor status indicators make central battery monitoring easy. Terms such as Discharging, Alarm or Warning for string status or Active for monitor status quickly summarize events. Conditions reported to the Central computer are displayed as a list, to easily identify trouble spots. The system also features several methods of automated reporting of alarm occurrences, such as contacting key personnel via a pager, email or fax. Flexibility was a major design consideration. Because the monitors are stand alone units with no external computer needed, a primary protocol using Modbus ASCII was selected to let you incorporate the monitor into large scale facility monitors. This allows third party interfaces to access all the stand alone features of the monitor, yet leaves the advanced features of the Data Manager remote communication software available for service personnel. 1.1. Normal Operating Mode In normal mode, the system scans all parameters in one to five seconds, depending on the configuration. As readings are taken, they are compared to user programmed alarm levels. The monitor can then call a Central computer and energize an alarm contact if a parameter exceeds a level. Front panel LEDs indicate scan and alarm status, and alarm events are stored in memory for future analysis. 1.2. Discharge Mode If a discharge is detected, the system goes into a data logging mode and stores battery voltages and discharge current into a discharge record. 1.3. Resistance Test Mode A battery resistance test may be performed at user set intervals. The test is similar to that performed by the Albér Cellcorder. On an MPM 100, up to eight intertiers can be configured for this measurement. 1.4. Alarm Features The monitor may be set to automatically call the Central computer to report an alarm condition when detected. You can program high and low alarm levels on all voltage and temperature parameters, and a high alarm level for resistance. When any parameter goes outside the normal range, the monitor stores the event in memory, the Alarm LED lights up, and an alarm relay with a Form C contact energizes. The alarms may be set for latching or nonlatching. 4200-062 1 Revision 2.01

1.5. Controlled Run Down Test You can program time intervals (in days) and length of time (in minutes) to have a contact closure optionally put the system on battery. During this time, the system treats the condition as a discharge and saves the changing parameters to a discharge record for playback and analysis. 1.6. MPM-100 Features This section describes standard and optional MPM 100 features. NOTE: Some features require optional accessories or are unit configuration dependent. Scans all pertinent battery parameters, such as overall voltage, cell voltages, current, and temperature. Performs a scheduled resistance test of all cells/jars, intertiers, and stores results for trending analysis. Auto detects discharges based on Overall Volts or Discharge Current, and stores data for real time or accelerated time playback. Signals if any parameter is outside user programmed limits, energizes a Form C relay contact, and calls a Central computer to report the alarm condition. Incorporates a Form C alarm contact for monitor hardware failure or power failure. Incorporates three 3 programmable contacts that are configurable to N/O or N/C. Communicates with an external computer via USB, modem, and RS 232/RJ 45/LAN. Performs a scheduled, user programmed test of putting the system on battery and monitoring discharge, with real time or fast time playback. Monitors up to 16 digital inputs. Network compatible. Continuous load unit (CLU) control. 1.7. Battery Monitor Data Manager (BMDM) Program Features Windows 2000, XP, 7 and 8 compatible Central computer control software. Easy to read string and monitor status. Automatic polling for over 1000 monitor sites for monitor and string status reporting. Historical event list for complete string history. Automatically receives calls from monitors and updates the central database for data analysis. Service mode for service personnel, and local USB direct connect viewing of string details and system setup when loaded on a laptop computer. Microsoft Access database compatible, with management of all stored data. Playback of discharge rundown test and controlled rundown test data. Automatic paging, emailing, and faxing of alarm events. Instant trend graphs of any selected parameter. Complete memo tracking down to the cell/module level. Status display can be customized for multi customer monitoring. Network compatible. SQL server compatible. 4200-062 2 Revision 2.01

1.8. Optional and additional Accessories The standard optional accessories are shown here, others are also readily available 954 623 6660. Optional and Additional Parts Description Photo Purpose Shunt 4720 017 Shunt for measuring discharge current. PHOTOS and PART NUMBERS VARY WITH CONFIGURATION REQUIREMENTS Figure 1. Shunt/Shunt Adapters Ambient temperature probe 2900 029 Temperature probe that hangs free for ambient temperature measurement. Refer to drawing BDS 159 A421. Figure 2. Ambient Temperature Probe 2900 029 Electrolyte temperature probe 2900 010 Figure 3. Electrolyte Temperature Probe 2900 010 Teflon coated probe, may be immersed in a flooded cell. Refer to drawing BDS 159 A421.

External Network Interface 2025 063 to include 2025 063P 2025 118 2025 120 4000 047R1.0 Please refer to part number 4000 047R1.0, UDS 10 External Network Interface Setup User s Guide for further instructions. Figure 4. External network interface 600 amp CT 5610 016 Use Drawing BDS 1120 A483 Rev C PHOTOS VARY DEPENDING UPON MODEL(S) CHOSEN Figure 5. 600 amp Current Transducer (CT) FCCP Kit 5610 051 Figure 6. Multitel Float Charging Current Probe Kit Float current measurement transducer for a single string. NOTE: Part number 5610 050 is for dual strings and would include one more clamp on the probe. 4200-062 4 Revision 2.01

2. Panel Controls and Indicators 2.1. Panel Controls and Indicators This section describes the front and rear panels that comprise a typical MPM 100 system. Figure 7. Rear Panel with RJ45 Figure 8. Rear Panel with RS 232 Figure 9. Front Panel

SCAN Flashes GREEN (G) during normal operating conditions ALARM When RED (R) indicates alarm condition detected ALARM DISABLE When RED (R) indicates user has disabled alarm reporting using BMDM software. Figure 10. Front Panel Indicators Close up RESISTANCE TEST Shows GREEN (G) as it performs a manual or automatic resistance test. ERROR When flashing RED (R) indicates hardware failure is detected Local Port Local Port Switch Alarm Reset USB port Connects to a laptop computer for servicing purposes. Enables the front USB or rear RJ 45 LAN/RS 232. When the switch is lit, the front USB port is selected. Figure 11. Front Panel Connector and Controls During normal operation, resets alarms. If held during power up, clears existing names in the monitor, disables alarms, disables dial out, clears data memory, and resets password to alber. 4200-062 6 Revision 2.01

Local Port J2 J5 J1, J3, J4, J6, J7 May be an RS 232 or an RJ 45 network port (LAN). The front panel Local Port Switch enables this port. Provides for alarm (Parameter & System) & digital input relay connections on all MPM configurations. Two sets of dry Form C alarm contacts are also available. Do not use for current transducers if J5 is available. Current Transducer CT connector optional. Provides for signal connection and +15V and 15V power for up to 4 discharge CTs and signal connection for the Float Current Sensor. Sense lead wiring to these connectors Depends upon battery configuration. Cell/Jar voltage sense leads connect from J1 to the individual cells/jars. (& J3 on units with the expansion module) TELCO RJ 11 jack. Communicates with a remote computer via telephone. Load Connections 16 to 20, 11 to 15, 6 to 10, 1 to 5 The most positive battery connection for string 1 must always be to Load Connection #1. The negative connection is determined by the battery configuration. Figure 12. Rear Panel Connectors Input 24VDC 1.2A When the MPM requires AC power because of battery configuration, connect a 24VDC wall plug transformer to this connector. AC power must be from a UPS protected source.

3. MPM-100 Configurations This section is an overview of the MPM 100 monitor configurations. 3.1. MPM Model Number Description The MPM can accommodate up to 30 different battery configurations, which may be modified for nonstandard battery configurations. (For example, a 1 x 60 configuration can have 59 cells.) The MPM 100 model numbers are structured as follows. 1001 nnna xxxxxx MPM model. Group of letters/numbers that indicates the following options: Position 1 (Xxxxxx): Power A = Unit is powered by AC wall plug. (Available only on 120V units.) D = Unit is powered by the DC bus. Position 2 (xxxxxx): Communication options (fiber optic, Ethernet or RS 232). Refer to Communication Options in this manual for details. Position 3 (xxxxxx): Method of sensing discharge current. C = Current transducer. S = Shunt. Position 4 (xxxxxx): Float current transducer. [blank] = No float current transducer. F = Float current transducer. Position 5 (xxxxxx): Main power line frequency. 5 = 50Hz. 6 = 60Hz. Position 6 (xxxxxx): Brand labeling. A = Albér. S = OEM model. Warning: check the configuration on MPM 100 before installation. Make sure that drawings are rechecked for configuration information. If the wrong configuration is installed onto the battery, the unit could be permanently damaged. 4200-062 8 Revision 2.01

3.2. MPM Configuration Options To determine MPM hardware configuration, cross reference the model number using the standard MPM Configuration Options Chart. For special configurations or custom system integration for OEM applications, contact Albér at 954 623 6660. Model Configuration Description Number 12V Systems 398 MPM 100 1x10x1* 1 string of 10 1v cells in series. 399 MPM 100 2x10x1 2 strings in parallel of 10 1v cells in series. 400 MPM 100 3x10x1 3 strings in parallel of 10 1v cells in series. 401 MPM 100 4x10x1 4 strings in parallel of 10 1v cells in series. Figure 13. MPM 12V Systems Configuration Options Chart Model Configuration Description Number 24V 36V Systems 360 MPM 100 1x20x1 1 string of 20 1v cells in series. 371 MPM 100 2x20x1 2 strings in parallel of 20 1v cells in series. 372 MPM 100 3x20x1 3 strings in parallel of 20 1v cells in series. 373 MPM 100 4x20x1 4 strings in parallel of 20 1v cells in series. 361 MPM 100 1x25x1 1 string of 25 1v cells in series. 362 MPM 100 2x25x1 2 strings in parallel of 25 1v cells in series. 363 MPM 100 3x25x1 3 strings in parallel of 25 1v cells in series. 364 MPM 100 4x25x1 4 strings in parallel of 25 1v cells in series. 402 MPM 100 1x26x1 1 string of 26 1v cells in series. 403 MPM 100 2x26x1 2 strings in parallel of 26 1v cells in series. 404 MPM 100 3x26x1 3 strings in parallel of 26 1v cells in series. 395 MPM 100 1x36x1 1 string of 36 1v cells in series. 396 MPM 100 2x36x1 2 strings in parallel of 36 1v cells in series. 338 MPM 100 1x12x2 1 string of 12 2v cells in series. 339 MPM 100 2x12x2 2 strings in parallel of 12 2v cells in series. 340 MPM 100 3x12x2 3 strings in parallel of 12 2v cells in series. 375 MPM 100 4x12x2 4 strings in parallel of 12 2v cells in series. 382 MPM 100 1x13x2 1 string of 13 2v cells in series. 383 MPM 100 2x13x2 2 strings in parallel of 13 2v cells in series. 384 MPM 100 3x13x2 3 strings in parallel of 13 2v cells in series. 385 MPM 100 4x13x2 4 strings in parallel of 13 2v cells in series. 334 MPM 100 1x6x4 1 string of 6 4v modules in series. 335 MPM 100 2x6x4 2 strings in parallel of 6 4v modules in series. 336 MPM 100 3x6x4 3 strings in parallel of 6 4v modules in series. 337 MPM 100 4x6x4 4 strings in parallel of 6 4v modules in series. 378 MPM 100 1x4x6 1 string of 4 6v modules in series. 379 MPM 100 2x4x6 2 strings in parallel of 4 6v modules in series.

380 MPM 100 3x4x6 3 strings in parallel of 4 6v modules in series. 381 MPM 100 4x4x6 4 strings in parallel of 4 6v modules in series. 374 MPM 100 1x3x8 1 string of 3 8v modules in series. 343 MPM 100 2x3x8 2 strings in parallel of 3 8v modules in series. 344 MPM 100 3x3x8 3 strings in parallel of 3 8v modules in series. 345 MPM 100 4x3x8 4 strings in parallel of 3 8v modules in series. 330 MPM 100 1x2x12 1 string of 2 12v modules in series. 331 MPM 100 2x2x12 2 strings in parallel of 2 12v modules in series. 332 MPM 100 3x2x12 3 strings in parallel of 2 12v modules in series. 333 MPM 100 4x2x12 4 strings in parallel of 2 12v modules in series. *1 volt cells are NiCd Figure 14. MPM 24V 36V Systems Configuration Options Chart Model Number Configuration Description 38 60V Systems 392 MPM 100 1x38x1 1 string of 38 1v cells in series. 393 MPM 100 2x38x1 2 strings in parallel of 38 1v cells in series. 410 MPM 100 1x41x1 1 string of 41 1v cells in series. 411 MPM 100 2x41x1 2 strings in parallel of 41 1v cells in series. 405 MPM 100 1x22x2 1 string of 22 2v cells in series. 406 MPM 100 2x22x2 2 strings in parallel of 22 2v cells in series. 407 MPM 100 3x22x2 3 strings in parallel of 22 2v cells in series. 408 MPM 100 4x22x2 4 strings in parallel of 22 2v cells in series. 354 MPM 100 1x24x2 1 string of 24 2v cells in series. 355 MPM 100 2x24x2 2 strings in parallel of 24 2v cells in series. 365 MPM 100 3x24x2 3 strings in parallel of 24 2v cells in series. 366 MPM 100 4x24x2 4 strings in parallel of 24 2v cells in series. 350 MPM 100 1x8x6 1 string of 8 6v modules in series. 351 MPM 100 2x8x6 2 strings in parallel of 8 6v modules in series. 352 MPM 100 3x8x6 3 strings in parallel of 8 6v modules in series. 353 MPM 100 4x8x6 4 strings in parallel of 8 6v modules in series. 394 MPM 100 1x9x6 1 string of 9 6v modules in series. 346 MPM 100 1x4x12 1 string of 4 12v modules in series. 347 MPM 100 2x4x12 2 strings in parallel of 4 12v modules in series. 348 MPM 100 3x4x12 3 strings in parallel of 4 12v modules in series. 349 MPM 100 4x4x12 4 strings in parallel of 4 12v modules in series. Figure 15. MPM 38V 60V Systems Configuration Options Chart Model Configuration Description Number 60 120V Systems 367 MPM 100 1x80x1 1 string of 80 1v cells in series. 388 MPM 100 1x88x1 1 string of 88 1v cells in series. 386 MPM 100 1x90x1 1 string of 90 1v cells in series. 368 MPM 100 1x92x1 1 string of 92 1v cells in series. 369 MPM 100 1x96x1 1 string of 96 1v cells in series. 370 MPM 100 1x97x1 1 string of 97 1v cells in series. 4200-062 10 Revision 2.01

389 MPM 100 1x100x1 1 string of 100 1v cells in series. 387 MPM 100 1x54x2 1 string of 54 2v cells in series. 409 MPM 100 1x56x2 1 string of 56 2v cells in series. 397 MPM 100 1x58x2 1 string of 58 2v cells in series 357 MPM 100 1x60x2 1 string of 60 2v cells in series. 358 MPM 100 1x30x4 1 string of 30 4v modules in series. 391 MPM 100 1x18x6 1 string of 18 6v modules in series. 359 MPM 100 1x20x6 1 string of 20 6v modules in series. 376 MPM 100 1x15x8 1 string of 15 8v modules in series. 377 MPM 100 2x15x8 2 strings in parallel of 15 8v modules in series. 390 MPM 100 1x8x12 1 string of 8 12v modules in series. 412 MPM 100 2x9x12 1 string of 9 12v modules in series. 356 MPM 100 1x10x12 1 string of 10 12v modules in series. Figure 16. MPM 60V 120V Systems Configuration Options Chart 4. MPM-100 Specifications Power 15 watts maximum. When monitoring 24V to 48V batteries, operates directly from the bus. When monitoring 120VDC batteries, powered off the battery or a 115VAC wall plug transformer. The transformer must be on a protected (uninterruptible) power source (UPS). Wall Plug Transformer: Albér part number 4000 029 Input: 100 to 240VAC, 50Hz/60Hz, 1.0A maximum Output: 24VDC (nominal), 1.5A 36W maximum 4.1. Fuses On PC Board (Not user replaceable) Fuse F1/F1A: 2A FB. Fuse F2: 1A FB. Fuse F3: 0.5A FB. 4.2. Measurement Range/Inputs Inputs Range Tolerance 100 cell voltage channels 2V range... (0 4V)... 0.1% 1mV 4V range... (0 8V)... 0.1% 2mV 6V range... (0 8.5V)... 0.1% 2mV 8V range... (0 10V)... 0.1% 10mV 12V range... (0 16V)... 0.1% 10mV One string voltage channel... 0 to 150 volts... 0.1% of reading 0.1V Eight temperature channels*... 0C to 80C (32F to 176F) 1C Eight intertier resistance channels... 0 to 5m... 5% of reading 5 Four discharge current channels*... 0 to 4000A... 0.1% of reading 1A (using shunt) Four float current channels*... 0 to 5000mA... 50mA Sixteen optically isolated contact closure inputs for normally open or normally closed.

Alarm reset. Normally open dry contact required. *Optional temperature and current transducers are required. Actual number of inputs are model dependent. Contact Alber for additional information 954 623 6660. Outputs Three programmable relay contact configured to N/O or N/C Parameters alarm contact: one Form C alarm relay contact, 2A at 30VDC. Hardware failure or power failure alarm contact: one Form C alarm relay contact, 2A at 30VDC. Charger control relay: one NO dry contact, 2A at 30VDC. LEDs (one each): green status, red alarm, red alarm disable, green resistance test on, and red hardware error. Measurement Range / Tolerance Cell resistance... 0 to 32,000µ... 5% of reading ±1 Communication A USB port A modem serial port An RJ 45 connection or RS 232 port connection Protocols: Modbus and SNMP. Data Storage E 2 nonvolatile memory for calibration constants, alarm levels, telephone numbers, and setup information. 100 alarm events in revolving nonvolatile memory. 32K bytes of discharge data in nonvolatile memory. 1.6K bytes resistance test records. 1.65K bytes historical data. Flash memory for firmware upgrades. Operating Environment Temperature range: 5C to 40C (41F to 104F) Humidity range: 0% to 80% RH (non condensing) at 5C to 31C 0% to 50% RH (non condensing) at 32C to 40C Indoor use only. Installation category II Pollution degree 2. Altitude 0 to 2000 meters above sea level. Packaging Rack mount. Wall mount with optional mounting brackets. Dimensions 19"W x 10"D x 1.75"H 6 lbs. 4200-062 12 Revision 2.01

Agencies UL listed. File number E212234. CE approved. 5. Communication Options This section describes the letter used in the second position of the MPM model number. Refer to the MPM 100 Configurations section for more details. Communication Option A Dedicated MPM OR PC RS 232 Option A This is for one MPM that will be accessed by one PC, either locally with an RS 232 connection or via telephone connection. NOTE: For all features to operate, the phone line used for the MPM must be dedicated to the MPM. Figure 17. MPM Model Number Communication Option A Communication Option B MPM Dedicated PC 1 PC 3 PC 2 PC 4 Option B This is for one MPM that will be accessed by two or more PCs via a telephone connection. NOTE: For all features to operate, the phone line used for the MPM must be dedicated to the MPM. Figure 18. MPM Model Number Communication Option B

Communication Option C MPM Dedicated PC 1 PC 2 RS 232 PC 5 Option C This is for one MPM that will be accessed locally by one PC via an RS 232 connection and That will also be accessed by additional PCs via a telephone connection. PC 3 PC 4 Figure 19. MPM Model Number Communication Option C NOTE: If the locally RS 232 connected PC is not the Central computer, then for all features to operate, the phone line used for the MPM must be dedicated to the MPM. Communication Option D Dedicated Phone Phone Line PC 1 Line Phone Phone Line PC 3 Line MPM PC 2 PC 4 PC 5 Ethernet Option Card HUB PC 6 PC 7 Option D This is for one MPM that will be accessed by two or more PCs locally. This option requires installation of the LAN option in the MPM, and This option also requires connection of the MPM to an existing LAN or installation of a LAN. The MPM can also be accessed by PCs via a telephone connection. The LAN can be set up to allow MPM access via the Internet. NOTE: If one of the PCs connected via the LAN is not the Central computer, then for all features to operate, the phone line used for the MPM must be dedicated to the MPM. Figure 20. MPM Model Number Communication Option D 4200-062 14 Revision 2.01

Communication Option E MPM Ethernet Option Card Option E This is for one MPM that will be accessed by two or more PCs locally. HUB This option requires installation of the LAN option in the MPM, and PC 1 This option also requires connection of the MPM to an existing LAN or installation of a LAN. PC 2 PC 3 The LAN can be set up to allow MPM access via the Internet. Figure 21. MPM Model Number Communication Option E Communication Option F Fiber optic MPM 1 MPM 2 RS-232 Serial Port Multiplexer RS 232 PC Option F This is for two to 16 MPMs that will be accessed by one PC via a serial connection. An RS 232 Serial Port Multiplexer is required. NOTE: The MPMs must be within 500 meters (cable run) of the Serial Port Multiplexer. Figure 22. MPM Model Number Communication Option F

Communication Option G Fiber optic Dedicated phone line MPM 1 MPM 2 Telco Serial Port Multiplexer PC 1 PC 3 PC 2 PC 4 Option G This is for two to 16 MPMs that will be accessed by one or more PCs via a phone line connection, and There will be one phone line for up to 16 MPMs. A Telco Serial Port Multiplexer is required. NOTE: The MPMs must be within 500 meters (cable run) of the Serial Port Multiplexer. Figure 23. MPM Model Number Communication Option G Communication Option H MPM MPM Dedicated Dedicated PC 1 PC 2 Option H This is for two or more MPMs that will be accessed via phone line connection, and All MPMs must have their own dedicated phone line. PC 3 PC 4 Figure 24. MPM Model Number Communication Option H 4200-062 16 Revision 2.01

Communication Option J MPM 1 MPM 2 Fiber optic Dedicated phone line Telco Serial Port Multiplexer RS 232 RS-232 Serial Port Multiplexer PC 5 Option J This is for two to 16 MPMs that will be accessed by one PC via a serial connection and other PCs via a phone line connection, and There will be one phone line for up to 16 MPMs. An RS 232 Serial Port Multiplexer is required. PC 1 PC 2 A Telco Serial Port Multiplexer is required. PC 3 PC 4 NOTE: The MPMs must be within 500 meters (cable run) of the Serial Port Multiplexers. Figure 25. MPM Model Number Communication Option J Communication Option K MPM Ethernet Option Card MPM Ethernet Option Card Option K This is for two to 16 MPMs that will be accessed locally by two or more PCs and accessed via a phone line, and There will be one phone line for up to 16 MPMs, and Telco Serial Port Multiplexer Dedicated phone line HUB PC 6 This option also requires connection of each MPM to an existing LAN or installation of a LAN, and PC 5 PC 7 This option requires installation of the LAN option in each MPM. PC 1 PC 2 The LAN can be set up to allow MPM access via the Internet. PC 3 PC 4 NOTE: The MPMs must be within 500 meters (cable run) of the Serial Port Multiplexer. Figure 26. MPM Model Number Communication Option K

Communication Option L MPM Ethernet Option Card MPM Ethernet Option Card Option L This is for two or more MPMs that will be accessed via a LAN and/or an Internet connection. HUB This option requires installation of the LAN option in the MPMs, and PC 2 PC 1 PC 3 This option also requires connection of each MPM to an existing LAN or installation of a LAN. Figure 27. MPM Model Number Communication Option L 4200-062 18 Revision 2.01