AXPC Manual Tank Gauging. Presented by Chad Hyman

Similar documents
Personal Breathing Zone, Area and Source Air Monitoring at Upstream Oil and Gas Facilities

Benzene measurement strategy

Final Bakken Crude Oil: Worker Health and Safety Pilot Scale Studies (April 30, 2018 Rev 0.1) Table of Contents

MultiRAE Pro Monitors (Model PGM-6248)

General Air Monitoring/ SCHMT Monitoring Equip. Working to meet established Hazmat Team Goals:

Outline. The Federal Regulations. Why Do the Tier-2 Testing?

Gas Generator ULTRA HIGH PURE - HIGH FLOW. Gas Generator

How to Develop a Methane Emissions Feasibility and Measurement Study

Gas Generators. Parker Balston

Residual Solvents in medical cannabis analysis using the SRI 8610C FID GC June 2014

PIDS AS HAZMAT RESPONSE TOOLS

Sensor Specifications and CroSS- Sensitivities

TVA-1000B. Instruction Manual Toxic Vapor Analyzer Part Number BK Sep2008

Process Gas Chromatographs For Process and Environmental Monitoring

TVA2020. Instruction Manual Toxic Vapor Analyzer Part Number Jan2014

METHOD 25 - DETERMINATION OF TOTAL GASEOUS NONMETHANE ORGANIC EMISSIONS AS CARBON

Portable Gas Detectors for Landfill Gases

TVOC Heated FID VE 7

Volatile Organic Compounds (VOCs) and Other Hazardous Exposures in Hydraulic Fracturing Tank Gauging Operations

3M Personal Safety Division. 3M TM EVM Series Environmental Monitor. EVM Series. Quick Start Guide

Monitoring for Toxic VOCs in Oil Industry Applications

DR1000 Flying Laboratory, Drone Environmental Monitoring

Fully Extractive Vs. Dilution Extractive CEMS

City of Fort Worth s Natural Gas Air Quality Study FINAL REPORT

Heated FID 109A. Rack Mount/Table Top NMGOC Analyzer

HAZ-SCANNER. Model HIM Complete Air Monitoring Station

Increasing Availability of Continuous and Real-Time VOC Monitoring Technologies for VI Assessment

ABB MEASUREMENT & ANALYTICS DATA SHEET. PGC5009 Fast process gas chromatograph

33101 TAMPERE.

Volatile Organic Compound Emissions Results from DCU Depressurization Vent Testing. Presented by: Chris Weber, Senior Chemist, URS Corporation

WEATHER MONITORING. Competitive rates available for long term hire. Hire rate Per week Per month

New Developments in Thermal Desorption (TD) Tube & Canister Technologies for Collection & Analysis of Soil Gas

Sensor Technologies used in Portable Gas Monitors. HA University

SENSOR SPECIFICATIONS AND CROSS-SENSITIVITIES

Ambient Air Quality Monitoring Baseline Report, Kirby Misperton A Wellsite, KM8 Production Well

STANDARD OPERATING PROCEDURES

Tar-Analyser TA Norman Poboss

Field test at Gehrkescher Hof in Wilmshagen/Germany

NWTPH-Gx. Volatile Petroleum Products Method for Soil and Water

ZEBRA ENVIRONMENTAL MIP/EC ZEBRA ENVIRONMENTAL DIRECT SENSING SAMPLING INSTALLATION INJECTIONS

P r o d u C T I N f o r m at I o n. The atmosphere must be just right

Available Laboratory Methods for Soil Gas Analysis

Using the PPM2 Portable Trace Moisture Transmitter

Use of Building Pressure Cycling in Vapor Intrusion Assessment

USE OF HIGH RESOLUTION CHARACTERIZATION DATA TO OPTIMIZE SOURCE AREA REMEDIATION AT AOC 50 AT FORMER BASE FORT DEVENS

Capillary GC Troubleshooting: a Practical Approach

Gas Turbine Inlet Air Cooling System

RESPONSE TO TVOC INVESTIGATE LEVEL EXCEEDANCES PROGRAM SPECIFIC PROCEDURE HONEYWELL AIR QUALITY MONITORING PROGRAM

Air Monitoring Directive Chapter 4: Monitoring Requirements and Equipment Technical Specifications

System Overview. Valve oven. Restrictor. Valve. Sample in and out

VOCs, CO 2, LEL, H 2 S, CO, O 2, SO 2, PH 3, NH 3, NO 2, HCN, Cl 2, ClO 2, O 3. Protect yourself. General Specifications

EuroFID Total Hydrocarbon Analyzer

Optimization of Volatile Petroleum Hydrocarbons Analysis by Automated Headspace Using Method Development Tools

Development of Tar Removal Technologies for Biomass Gasification using the By-products

PILOT PROJECT «ILE DE FRANCE»

Foaming Manure Pit Dangers

Soil vapor surveys can be used for a number of purposes, including the following:

Methane concentrations are measured using portable gas detection instruments, usually a methane meter or explosimeter which has a readout in either

Super Clean Gas Filters Simply the best

THE LEADER IN PERFORMANCE INDOOR AIR QUALITY MEASUREMENTS

Supporting Information. Christina W. Li and Matthew W. Kanan* *To whom correspondence should be addressed.

Intrinsic Safety & Hazardous Areas

Biogas analysers. Product overview. MRU over 30 years of innovative gas analysis! Biogas, landfill gas, biomethane, coal mine gas, CHP exhaust gas

Calibration of MiniRAE 2000 and 3000 and Experience using them in the Field

Evaluation of VOC Emission Measurement Methods for Paint Spray Booths

Sampling and Analysis in Vapor Intrusion Investigations. Andy Rezendes, Technical Sales-Air Analysis

Crowcon Technical Note

Crowcon Technical Note

Gas sensors market and technology trends

PVI Risk Pathway: Sampling Considerations

Passive Monitoring: A Guide to Sorbent Tube Sampling for EPA Method 325. Nicola Watson July 2015

Proudly serving laboratories worldwide since 1979 CALL for Refurbished & Certified Lab Equipment Parker N2-04

Field Tests of Chloroform Collection/Analysis Methods

Isco EZ TOC. TOC and TC Analysis Made Easy. Continuous on-line TOC/TC measurement using low-temperature oxidation

Online Gas Analyzer / Monitor

Evaluation of Occupational Exposures during Flowbackand Production Testing (Completions Operations) in the Oil and Gas Industry

EPA's Proposed Air Pollution Standards for the Oil and Natural Gas Sector Preliminary Analysis September 2011

METHOD 25D - DETERMINATION OF THE VOLATILE ORGANIC CONCENTRATION OF WASTE SAMPLES. NOTE: Performance of this method should not be

ATTACHMENT 1 GENERAL FACILITY INFORMATION. BOD5 mg/l mg/l TSS mg/l mg/l NH3-N mg/l mg/l

Ultra High Purity Hydrogen Generators

Soft Ionization Spectrometry (SIS):

Body of Knowledge: Field Use of Direct-Reading Instruments for Detection of Gases and Vapors

Stack Gas Analyzer ENDA-7000 ULTIMATE. Ultimate Reliability. Ultimate. Ultimate. Dependability. Accessibility

Chambers and Instrumentation CHAMBERS. STORA: 22 m 3 chamber

Interior air of road vehicles Pollution content in the interior of driver cab and passenger compartment Technical requirements and test methods

BUILDING AS-843 NEW RI-7ER, NORTH CAROLINA NOVEMBER 13, 1992'

Agilent Ultimate Plus Fused Silica Tubing

Capabilities, Limitations and Proper Use of Multisensor Gas Detectors

Miniature Helium Purifier and Nitrogen Purifier Instruction Manual

ICAC MARAMA Portable Emission Analyzers

Operating the SRI RGD ( Reduction Gas Detector )

SAFETY DATA SHEET SECTION 1 CHEMICAL PRODUCT AND COMPANY IDENTIFICATION. 3 Cemetery Drive Ogdensburg, NY 13669

DNV GL Gas ready notation

HW6 - MGP Site Bioremediation

Global Calibration Gases LLC

Item Hydrogen Gas Plant

Solutions for monitoring VOCs in air

Use of Crawl Space Sampling Data and Other Lines of Evidence for Evaluating Vapor Intrusion

Transcription:

AXPC Manual Tank Gauging Presented by Chad Hyman

Introduction The current and primary method used for tank gauging is remote gauging Evaluate protective methods for production operators when the operational process requires opening the hatch of the holding tank (tank battery) 1

Objectives Evaluate potential risk of production operator without engineering/administrative controls Evaluate risk reduction of current controls Correlate 4 gas monitoring data with potential BTEX and Naphthalene exposures Correlate data variations based on well product compositions 2

Equipment/Sampling Media MultiRae (NDIR) - % Methane, %LEL, Oxygen, CO Breathing zone on chest ToxiRae (WB) - % LEL Breathing zone on chest Photoionization Detector (PID) 10.6 ev lamp Midsection of individual Used primarily as a reference when collecting BTEX samples Flame Ionization Detector - TVA 1000 Evaluate the breathing zone of the individual Grab Sample at Source (1 above hatch) - VeriAir Flex GC analysis for Total VOC Compare to FID BZ sample BTEX Charcoal Tube with Pump BTEX & Naphthalene 1 LPM for various range (3-8 minutes) 3

Sampling Method Appointed locations based on risk evaluation Product composition, natural air movement, equipment setup Three locations identified Monitoring conducted over a two day period Two days were used to limit the variability in data collection Limit change in pressure, evaporation, ect. Time and temperature were correlated to limit variability Day 1 - No controls in place During initial venting and purging of the system Day 2 Controls in place Initial venting, following SOP, and altered SOP Same instruments and sampling media were used for each sampling event 4

Evaluation Method Day 1 No Controls Atmospheric testing during the initial opening of the hatch Source grab sample (VOC, BTEX) FID in BZ PID LEL, Methane, Oxygen Atmospheric testing during plunger run/separator dump Equipment setup did not allow this represented sampling at the facility with wet gas collection Source grab sample (VOC, BTEX) FID in BZ PID BTEX, Naphthalene in BZ LEL, Methane, Oxygen 5

Analytical Highlights No Controls Initial Total VOC 76,000 ppm FID >50,000 ppm PID 124 ppm BTEX (BZ) (not taken) LEL 100 % Methane ~ 5.0 % Oxygen 19.0 % Purging Total VOC 600,000 ppm FID >50,000 ppm PID 308 ppm BTEX (BZ) >55 ppm LEL 100 % Methane 94.80 % Oxygen 9.80 % 6

Evaluation Method Day 2 SOPs Data was collected per potential exposure to the employee With the exception of the grab samples and BTEX, sample collection was noted at its peak and during the performed task Source grab sample (VOC, BTEX) FID in BZ PID BTEX, Naphthalene in BZ LEL, Methane, Oxygen Alterations to the SOP With the exception of the grab samples and BTEX, sample collection was noted at its peak and during the performed task Alterations were made to the SOP between each sampling event for comparative purposes Source grab sample (VOC, BTEX) FID in BZ PID BTEX, Naphthalene in BZ LEL, Methane, Oxygen 7

Evaluation Method Day 2 Example of Engineering Controls 8

Evaluation Method Day 2 Example of Engineering Controls 9

Analytical Highlights SOPs 1 Minute Ventilation Opening FID 300 ppm (Opening) LEL 6.0 % (Opening) 2 Minute Ventilation Opening FID 400 ppm (Opening) LEL 6.0 % (Opening) Gauging Total VOC 4,000 ppm FID 40 ppm (Gauging) LEL 0.0% (Gauging) BTEX - <0.1 ppm Gauging Total VOC 0 ppm FID 0.8 ppm (Gauging) LEL 0.0% (Gauging) BTEX - <0.1 ppm 10

Analytical Highlights Control Comparison Purging Total VOC 600,000 ppm FID >50,000 ppm PID 308 ppm BTEX (BZ) >55 ppm LEL 100 % Methane 94.80 % Oxygen 9.80 % Isolation with 2 Minute Ventilation Total VOC 0 ppm FID 0.8 ppm PID 54.6 ppm BTEX - <0.10 ppm LEL 0.0 % Methane 0.00 % Oxygen ambient 11

Additional Observations Correlating the %LEL values with collected BTEX data suggests that a threshold of 10% LEL is adequate in controlling the BTEX levels to below the health standard 4.0-6.0 % LEL resulted in a BTEX exposure of less 0.10 ppm in three different cases Potential exposure at: Gas Process Unit (GPU) Drip Tanks 12