Clean-up of Sequencing Reactions

Similar documents
NucleoMag SEP Magnetic Separator

RNA and DNA purification

RNA and DNA purification

PCR clean-up. User manual. NucleoFast 96 PCR. June 2017 / Rev. 06.

Total RNA and DNA Purification

User manual MACHEREY-NAGEL. NucleoSpin RNA/ DNA buffer set. April 2005/Rev. 02

Genomic DNA clean-up

Instructions for Use

DNA and RNA Clean-up Guide

SPEEDTOOLS DNA EXTRACTION KIT

User manual MACHEREY-NAGEL. NucleoSpin RNA Clean-up. NucleoBond PC 500 NucleoBond BAC 100 NucleoBond PC 2000 PC October 2004/Rev.

Viral RNA and DNA. User manual. NucleoSpin Virus. April 2017 / Rev. 03.

Nucleo-pore Yeastlytic Fungal DNA Extraction Kit

EasyPrep TM Adeno-Associated. Virus Purification Mini Kit Manual. (All Serotype) Catalog#: AAV11-00, AAV11-01, AAV11-02

Size-Select Kit for NGS Library Preparation Product # 53600

Nucleopore FFPE DNA Miniprep Kit

PureLink Quick Gel Extraction Kit

Plasmid DNA Purification

StrataPrep PCR Purification Kit

Genomic DNA from organs and cells

Kit Components Product # (50 samples) Wash Solution A Elution Buffer B

RNA Clean-Up and Concentration Kit Product # 23600, 43200

EasyPrep TM Total RNA Extraction Miniprep Manual

Kit Specifications 45 g. 45 g of RNA 8 L

Specifications. Kit Specifications. Alcohol Precipitation: Up to 100 ml Column Purification: Up to 5 ml Column Binding Capacity 25 µg

foodproof Sample Preparation Kit III

Product Specifications & Manual

ULTRAPrep PLASMID DNA KIT

Cytoplasmic & Nuclear RNA Purification Kit Product # 21000, 37400

StrataPrep Plasmid Miniprep Kit

EasyPrep TM Adeno-associated Virus Purification Mini Kit Manual

illustra MicroSpin G-25 Columns Spin columns for the purification of oligonucleotides and small DNA fragments

DNA Extraction Kit INSTRUCTION MANUAL. Catalog # Revision A. For In Vitro Use Only

DNA Extraction Kit INSTRUCTION MANUAL. Catalog # Revision B. For In Vitro Use Only

Average Yields* Yeast DNA Yeast RNA Time to Complete 10 Purifications * Yield will vary depending on the type of sample processed

NRAS Codon 61 Mutation Analysis Reagents

PureLink Plant Total DNA Purification Kit

Genomic DNA Extraction Mini Kit (Blood and Urine)

ISOLATE II Blood DNA Kit. Product Manual

Product # Specifications. Kit Specifications Maximum Column Binding Capacity (gdna) Maximum Column Loading Volume.

Applications Note 161 March 2010

Product # 24700, 24750

Life science unlimited

Milk DNA Preservation and Isolation Kit Product #44800

Product # (10 preps) Lysis Additive A Binding Buffer I. Elution Buffer B

NRAS Mutation Analysis Reagents (Codons 12 and 13)

Bead Type (NaI) Gel Extraction Kits

Small RNA and DNA from Plasma

TIANamp Marine Animals DNA Kit

Bioneer Corporation 8-11,Munpyeongseo-ro, Daedeok-gu, Daejeon 34302, Republic of Korea Tel: Fax:

ReliaPrep FFPE gdna Miniprep System

BigDye Direct Cycle Sequencing Kit

SEQueaky Kleen H 2 0 Dye Terminator Removal Kit

ProteoSpin Urine Protein Concentration Maxi Kit Product # 21600

PCR clean-up Gel extraction

Fast and reliable purification of up to 100 µg of transfection-grade plasmid DNA using a spin-column.

Product # Kit Specification. Kit Specifications Maximum Column Binding Capacity 50 µg Maximum Column Loading Volume 650 µl

Cells and Tissue DNA Isolation 96-Well Kit (Magnetic Bead System) Product # 62500

Cells and Tissue DNA Isolation Kit (Magnetic Bead System) 50 Preps Product # 59100

BIO NEWS. Food Diagnostics Special. Genomic DNA from food and feed for GMO detection / quantification and animal species differentiation

TIANpure Mini Plasmid Kit II

PCR clean-up Gel extraction

Product # Specifications. Kit Specifications Maximum DNA Input. 200 g Maximum DNA Volume Input Final Endotoxin Levels

HighPrep Blood & Tissue DNA Kit

Manual innuprep DNA Micro Kit

Thermo Scientific GeneJET Plant Genomic DNA Purification Mini Kit #K0791, #K0792

ZR-96 DNA Sequencing Clean-up Kit Catalog Nos. D4052 & D4053

Plant/Fungi Total RNA Purification Kit Product # 25800, 31350, 25850

QuickTox Kit for T-2 / HT-2 Flex

MERmaid Kit preps preps Filters/Catch Tubes Filters/Catch Tubes Filters/Catch Tubes

Product # (12 samples) Solution WN. Elution Buffer B Proteinase K Maxi Spin Columns 12 Collection Tubes 12 Elution Tubes 12 Product Insert 1

Quantos Cell Proliferation Assay Kit

PureSpin DNA Clean Up Kit

Blood DNA Extraction Kit

FastGene Plasmid Mini Kit For isolation of high copy and low copy plasmid DNA

Absolutely RNA Microprep Kit

Reagent Kit Selection Guide

PrepSEQ Residual DNA Sample Preparation Kit

MD60002 MD MD62002

mdi Micro Gel Extraction Kit User Guide ADVANCED MICRODEVICES PVT. LTD. Membrane Technologies 21, Industrial Area, Ambala Cantt (INDIA)

Sample Preparation Demonstrated Protocol

BIO BASIC. Gel Extraction Kit. 9K s (10 preps) 9K (100 preps) 9K (200 preps) For Research Use Only

RPM. Rapid Pure Miniprep Kit preps preps preps preps preps

RNA from blood. User manual. NucleoSpin RNA Blood NucleoSpin RNA Blood Midi. September 2017 / Rev. 05.

Maximum Yield Mini System. Protocol Book YPD100 // YPD300. Ver

GeneJET Gel Extraction Kit #K0691, #K0692. }!tc!!!#!!h~ PA-K069

by nexttec TM 1 -Step

Please read all the information in booklet before using the unit

Adeno Associated Virus (AAV) Purification ViraKit

mdi Gel Extraction Kit User Guide ADVANCED MICRODEVICES PVT. LTD. Membrane Technologies 21, Industrial Area, Ambala Cantt (INDIA)

MB542 HiPurA TM Soil DNA Purification Kit

Plasmid DNA Purification

Vials and caps. Vials and inserts Closures and septa Accessories.

Introduction. Principle

TIANamp Yeast DNA Kit

Plant Genomic DNA Kit

Instructions for Use Life Science Kits & Assays

ab Total Protein Thiol Quantitation Assay Kit (Colorimetric)

For Research Use Only Ver

Quick and easy 7 minute protocol to select for 300 bp, 200 bp, 150 bp, 100 bp, 50 bp DNA fragments or perform a double size selection

Transcription:

Clean-up of Sequencing Reactions User manual NucleoSEQ July 2017 / Rev. 04 www.mn-net.com

Contact MN Germany and international MACHEREY-NAGEL GmbH & Co. KG Neumann-Neander-Str. 6 8 52355 Düren Germany Tel.: +49 24 21 969-0 Toll-free: 0800 26 16 000 (Germany only) Fax: +49 24 21 969-199 E-mail: info@mn-net.com Technical Support Bioanalysis Tel.: +49 24 21 969-270 E-mail: tech-bio@mn-net.com USA MACHEREY-NAGEL Inc. 2850 Emrick Blvd. Bethlehem, PA 18020 USA Tel.: +1 484 821 0984 Toll-free: 888 321 6224 (MACH) Fax: +1 484 821 1272 E-mail: sales-us@mn-net.com France MACHEREY-NAGEL SARL à associé unique 1, rue Gutenberg 67722 Hoerdt France Tel.: +33 388 68 22 68 Fax: +33 388 51 76 88 E-mail: sales-fr@mn-net.com Switzerland MACHEREY-NAGEL AG Hirsackerstr. 7 4702 Oensingen Switzerland Tel.: +41 62 388 55 00 Fax: +41 62 388 55 05 E-mail: sales-ch@mn-net.com www.mn-net.com

Clean-up of Sequencing Reactions Table of contents 1 Components 4 1.1 Kit contents 4 1.2 Material to be supplied by user 4 2 Product description 5 2.1 The basic principle 5 2.2 Kit specifications 5 3 Storage conditions 5 4 Safety instructions 5 5 Protocol for sequencing reaction clean-up 6 6 Appendix 8 6.1 Troubleshooting 8 6.2 Ordering information 8 6.3 Product use restriction / warranty 9 3

Clean-up of Sequencing Reactions 1 Components 1.1 Kit contents NucleoSEQ REF 10 preps 740523.10 50 preps 740523.50 250 preps 740523.250 NucleoSEQ Columns 10 50 250 Collection Tubes 10 50 250 User Manual 1 1 1 1.2 Material to be supplied by user Collection tubes (e.g., 1.5 ml microcentrifuge tubes) 4

Clean-up of Sequencing Reactions 2 Product description 2.1 The basic principle NucleoSEQ Columns are designed for fast and effective clean-up of nucleic acids. Using gel exclusion in a convenient spin column format allows reliable removal of smaller molecules from nucleic acids. Impurities, for example, salts, excess of labels, nucleotides, traces of organic solvents, primers are retained by the column while nucleic acids of interest are recovered with high yield. The columns are pre-filled with size exclusion matrix. 2.2 Kit specifications Maximum sample volume to be loaded onto the column: 20 µl Removal of sequencing dye terminators including BigDye 3 Storage conditions NucleoSEQ Columns with dry gel matrix can be stored at room temperature for 12 months. NucleoSEQ Columns with hydrated gel matrix should be stored at 4 C. Columns can be stored up to 14 days at 4 C. 4 Safety instructions The components of the NucleoSEQ kits do not contain hazardous contents. 5

NucleoSEQ 5 Protocol for sequencing reaction clean-up General procedure (For details on each step see page 7.) 1 Spin down dried gel resin 750 x g 30 s 2 Hydrate gel resin with 600 µl water, vortex, and incubate at least 30 min for complete hydration 3 Remove bottom plug and spin down hydrated gel resin 600 µl water RT > 30 min 750 x g 2 min 4 Load sample to the center of the column Load column 5 Spin for 4 6 min at 750 x g to recover purified sample 750 x g 4 6 min 6

NucleoSEQ Detailed procedure Perform sequencing reaction according to standard protocols. We recommend to use not more than 1 2 µl of Big Dye Ready reaction mix in a 20 µl sequencing reaction in order to avoid overloading the column. 1 Centrifuge the NucleoSEQ Columns for 30 s at 750 x g to collect the dry gel matrix on the bottom of the cartridge. 2 Add 600 µl dist. water and vortex to hydrate the gel matrix. Remove air bubbles by vortexing or tapping the column. Incubate at least 30 min or overnight to hydrate the gel matrix. Incubation can be performed at room temperature or 4 C. Hydrated columns can be stored at 4 C for a maximum of 14 days. Resuspend the settled gel matrix by inverting or vortexing the spin column several times. Air bubbles should not be visible now. Remove the bottom plug and place the spin column into a Collection Tube (supplied with the kit). 3 Place the column into an appropriate centrifuge (the hinge of the spin column`s cover lid should be orientated to the outside of the rotor). Centrifuge 2 min at 750 x g to remove the remaining storage buffer. Discard the collection tube with storage buffer. Place the spin column in an appropriate collection tube (e.g., microcentrifuge tube, not supplied with the kit). 4 Open the lid of the column. Carefully load the sample drop by drop onto the center of the gel resin. Pipetting the sample at the sides of the spin column tube may reduce purification efficiency of the column. Moreover, do not disturb the gel surface. Sample volume should not exceed 20 µl. 5 Place the column in the same orientation as in step 3 into the centrifuge. Elute the sample by centrifuging the column for 4 6 min at 750 x g. Discard the spin column. Dry the sample or use the sample directly. 7

Clean-up of Sequencing Reactions 6 Appendix 6.1 Troubleshooting Problem Possible cause and suggestions Sample added to column improperly Dye blobs Poor signal intensity Add sample directly to the center of the settled gel matrix. Dispense sample dropwise. Avoid adding sample at the sides of the gel matrix Sample volume to high Add sample in a volume of 20 µl. Higher sample volumes can cause incomplete removal of dye terminators. Sample volume to small Add sample in a volume of 20 µl. If necessary adjust sample volume to 20 µl using distilled water Conversion of RCF from different centrifuges: rpm = 100 x RCF / 1.12r RCF = (rpm / 1000)² x 1.12r rpm = revolutions per minute RCF = relative centrifugal force (g force = RCF x g) r = radius in mm 6.2 Ordering information Product REF Pack of NucleoSEQ 740523.10 /.50 /.250 10 / 50 / 250 Visit www.mn-net.com for more detailed product information. 8

Clean-up of Sequencing Reactions 6.3 Product use restriction / warranty NucleoSEQ kit components are intended, developed, designed, and sold FOR RESEARCH PURPOSES ONLY, except, however, any other function of the product being expressly described in original MACHEREY-NAGEL product leaflets. MACHEREY-NAGEL products are intended for GENERAL LABORATORY USE ONLY! MACHEREY-NAGEL products are suited for QUALIFIED PERSONNEL ONLY! MACHEREY- NAGEL products shall in any event only be used wearing adequate PROTECTIVE CLOTHING. For detailed information please refer to the respective Material Safety Data Sheet of the product! MACHEREY-NAGEL products shall exclusively be used in an ADEQUATE TEST ENVIRONMENT. MACHEREY-NAGEL does not assume any responsibility for damages due to improper application of our products in other fields of application. Application on the human body is STRICTLY FORBIDDEN. The respective user is liable for any and all damages resulting from such application. DNA/RNA/PROTEIN purification products of MACHEREY-NAGEL are suitable for IN-VITRO- USES ONLY! ONLY MACHEREY-NAGEL products specially labeled as IVD are also suitable for IN-VITROdiagnostic use. Please pay attention to the package of the product. IN-VITRO-diagnostic products are expressly marked as IVD on the packaging. IF THERE IS NO IVD SIGN, THE PRODUCT SHALL NOT BE SUITABLE FOR IN-VITRO- DIAGNOSTIC USE! ALL OTHER PRODUCTS NOT LABELED AS IVD ARE NOT SUITED FOR ANY CLINICAL USE (INCLUDING, BUT NOT LIMITED TO DIAGNOSTIC, THERAPEUTIC AND/OR PROGNOSTIC USE). No claim or representations is intended for its use to identify any specific organism or for clinical use (included, but not limited to diagnostic, prognostic, therapeutic, or blood banking). It is rather in the responsibility of the user or - in any case of resale of the products - in the responsibility of the reseller to inspect and assure the use of the DNA/RNA/protein purification products of MACHEREY-NAGEL for a well-defined and specific application. MACHEREY-NAGEL shall only be responsible for the product specifications and the performance range of MN products according to the specifications of in-house quality control, product documentation and marketing material. This MACHEREY-NAGEL product is shipped with documentation stating specifications and other technical information. MACHEREY-NAGEL warrants to meet the stated specifications. MACHEREY-NAGEL s sole obligation and the customer s sole remedy is limited to replacement of products free of charge in the event products fail to perform as warranted. Supplementary reference is made to the general business terms and conditions of MACHEREY-NAGEL, which are printed on the price list. Please contact us if you wish to get an extra copy. There is no warranty for and MACHEREY-NAGEL is not liable for damages or defects arising in shipping and handling (transport insurance for customers excluded), or out of accident or improper or abnormal use of this product; defects in products or components not manufactured by MACHEREY-NAGEL, or damages resulting from such non-macherey- NAGEL components or products. MACHEREY-NAGEL makes no other warranty of any kind whatsoever, and SPECIFICALLY DISCLAIMS AND EXCLUDES ALL OTHER WARRANTIES OF ANY KIND OR NATURE 9

Clean-up of Sequencing Reactions WHATSOEVER, DIRECTLY OR INDIRECTLY, EXPRESS OR IMPLIED, INCLUDING, WITHOUT LIMITATION, AS TO THE SUITABILITY, REPRODUCTIVITY, DURABILITY, FITNESS FOR A PARTICULAR PURPOSE OR USE, MERCHANTABILITY, CONDITION, OR ANY OTHER MATTER WITH RESPECT TO MACHEREY-NAGEL PRODUCTS. In no event shall MACHEREY-NAGEL be liable for claims for any other damages, whether direct, indirect, incidental, compensatory, foreseeable, consequential, or special (including but not limited to loss of use, revenue or profit), whether based upon warranty, contract, tort (including negligence) or strict liability arising in connection with the sale or the failure of MACHEREY-NAGEL products to perform in accordance with the stated specifications. This warranty is exclusive and MACHEREY-NAGEL makes no other warranty expressed or implied. The warranty provided herein and the data, specifications and descriptions of this MACHEREY-NAGEL product appearing in MACHEREY-NAGEL published catalogues and product literature are MACHEREY-NAGEL s sole representations concerning the product and warranty. No other statements or representations, written or oral, by MACHEREY- NAGEL s employees, agent or representatives, except written statements signed by a duly authorized officer of MACHEREY-NAGEL are authorized; they should not be relied upon by the customer and are not a part of the contract of sale or of this warranty. Product claims are subject to change. Therefore please contact our Technical Service Team for the most up-to-date information on MACHEREY-NAGEL products. You may also contact your local distributor for general scientific information. Applications mentioned in MACHEREY- NAGEL literature are provided for informational purposes only. MACHEREY-NAGEL does not warrant that all applications have been tested in MACHEREY-NAGEL laboratories using MACHEREY-NAGEL products. MACHEREY-NAGEL does not warrant the correctness of any of those applications. Last updated: 07 / 2010, Rev. 03 Please contact: MACHEREY-NAGEL GmbH & Co. KG Tel.: +49 (0) 24 21 969 270 e-mail: tech-bio@mn-net.com Trademarks / Disclaimer: BigDye is a trademark of a member of Applied Biosystems NucleoSEQ is a registered trademark of MACHEREY-NAGEL GmbH & Co. KG All used names and denotations can be brands, trademarks, or registered labels of their respective owner also if they are not special denotation. To mention products and brands is only a kind of information (i.e., it does not offend against trademarks and brands and can not be seen as a kind of recommendation or assessment). Regarding these products or services we can not grant any guarantees regarding selection, efficiency, or operation. 10

Plasmid DNA Clean-up RNA Genomic DNA Viral RNA and DNA Protein High throughput Accessories Auxiliary tools

www.mn-net.com MACHEREY-NAGEL GmbH & Co. KG Neumann-Neander-Str. 6 8 52355 Düren Germany DE / International: CH: FR: Tel.: +49 24 21 969-0 Fax: +49 24 21 969-199 E-mail: info@mn-net.com Tel.: +41 62 388 55 00 Fax: +41 62 388 55 05 E-mail: sales-ch@mn-net.com Tel.: +33 388 68 22 68 Fax: +33 388 51 76 88 E-mail: sales-fr@mn-net.com US: Tel.: +1 484 821 0984 Fax: +1 484 821 1272 E-mail: sales-us@mn-net.com A030334/0771.5