Alkaline Non-Cyanide Zinc Plating Process

Similar documents
Diamante. Alkaline Plating Systems Diamante. Alkaline Plating Systems

High Throw Bright Acid Copper for Rack and Barrel Plating

ZINC PLATING SYSTEMS NH4 Zn/Co

HAVALLOY Z-C ACID CHLORIDE ZINC / COBALT PROCESS

Brass Plating Process

Laser EX 50 Product Code: Revised Date: 03/17/2009. Laser EX 50

Metal Finishing Products and Service META-MATE ZINCATE 40 "A CONCENTRATED LIQUID ZINCATE FORMULATION FOR THE PRETREATMENT OF ALUMINUM AND ITS ALLOYS"

SurTec 717 Alkaline Zinc/Nickel Electroplating Process (Electrolyte based on Sodium)

-.O oz/gal. It is again desirable to have some means of mechanical agitation.

Plating Systems Hex - A - Gone

Manufactured for North America exclusively by Automated Chemical Solutions, Inc E. Roeser Road Phoenix, Arizona 85040

Laser ACB 50 Product Code: Revised Date: 03/17/2009. Laser ACB 50

TECHNICAL DATA SHEET CUPROBRITE Revolutionary & New generation Bright Acid Copper Plating Process

Plating System. Hexavalent Chromium-free Reduced energy consumption

Black Magic Infusion Powder Product Code: Revised Date: 07/18/2016. Black Magic Infusion Powder

SurTec 881 Trivalent Decorative Chromium Process

TINGLO CULMO Bright Acid Tin Electroplating (with Starter/Brightener 2.5X) For Electronic Finishing Applications

PROBLEM CAUSE SOLUTION

NITEC CRYSTAL 1. Elektrolyt to achieve uniform and non reflective Nickel deposits

HAVACHROME CR3 TRIVALENT BRIGHT CHROMIUM PROCESS

NICKEL GLEAM BR 220 BRIGHT NICKEL PROCESS

Luster-On Products. Technical Data Sheet LUSTER-FOS 2900 CALCIUM MODIFIED, FINE GRAINED ZINC PHOSPHATE

Activated Black Magic Plus Product Code: Revised Date: 10/26/2016. Activated Black Magic Plus Black Oxide Finish for Steel

Room Temperature Metal Blackening & Antiquing Processes. Hot & Mid Temp Oxide Finishes Metal Cleaning & Surface Preps

DURNI-COAT DNC

Modern Trivalent Chrome Plating Technology Comparison. By Matt Stauffer PAVCO, Inc.

Technical Data Sheet. Physical Specifications

PALLAMET 500 Palladium-Nickel

OPERATING INSTRUCTIONS FOR TCCG & TCACG 267 & 1000 ML HEATED HULL CELLS (110 VOLT)

Technical Process Bulletin

TECHNICAL INFORMATION GRANODINE 20

Lead-free electroless plating nickel bath for high wear and corrosion resistant applications

SOLDERON BLS For Electronic Finishing Applications

PALLAMERSE SMT 2000 For PWB Metallization Applications

ENVIRO/Etch Replenisher

ELECTROLESS NICKEL DATA SHEET March 2013

CLEANING AND PASSIVATING OF STAINLESS STEEL EQUIPMENT

Electroplating. Copyright 2016 Industrial Metallurgists, LLC

ELECTRONIC GRADE SULFAMATE NICKEL Document ID: EFM1409

SOLDERON MHS-W MATTE TIN AND TIN-LEAD PROCESS

ACTANE 341 Liquid concentrate

Technical Process Bulletin

Copper Odyssey. Chemical Reactions of Copper

TINPOSIT LT-26 IMMERSION TIN For PWB Metallization Applications

CEE-BEE CLEANER A-7X7 by Cee-Bee

SUPER BEE 400TG-ML CLEANER by Cee-Bee

TITANIUM DIOXIDE. SYNONYMS Titania; CI Pigment white 6; CI (1975) No ; INS No. 171 DEFINITION DESCRIPTION FUNCTIONAL USES CHARACTERISTICS

BOMBARDIER AEROSPACE LEARJET ENGINEERING SPECIFICATION

P.T. SINAR CEMARAMAS ABADI

CHAPTER 3 DEVELOPMENT OF ELECTROPLATING SETUP FOR PLATING ABS AND POLYAMIDES

NASF Technical Conference 2007 Cleveland, Ohio August 14th, 2007

Scibond SL-23 Polymeric Lubrication System for Tube Drawing

United States Environmental Protection Agency Research and Development. Project Summary. Jacqueline M. Peden

Trivalent Yellow Chromate. NASF Technical Conference August 14 th, 2007 Cleveland,OH

INTRODUCTION TO ELECTROCHEMISTRY: CURRENT, VOLTAGE, & BATTERIES. Introduction. Electrochemistry Revised 4/28/14

Nickel Electroplating

ALODINE 5200 CONVERSION COATING PROCESS FOR ALUMINIUM

CONSERVATION OF MATTER AND CHEMICAL PROPERTIES

MOLYBDENITE CONCENTRATES

Compact Electro Plating Machine - CEPM-2A USER MANUAL

ELECTROLESS NICKEL AND ELECTROLESS KROME PLATING Acid Nickel Process: 5-7% phosphorus

HAND BOOK OF ELECTROPLATING ANODIZING & SURFACE FINISHING TECHNOLOGY

RITTER Pickling Fluids finished blending VA 10 concentrate 1:1 VA 15 concentrate 1:2 VA 20

Method 108C - Determination of Arsenic Content in Ore Samples From Nonferrous Smelters (Molybdenum Blue Photometric Procedure)

ZACLON GALVANIZING FLUXES

TECHNICAL GRADE MOLYBDENUM OXIDE

Method 5.9 Syrup: calcium and magnesium by EDTA titration

Understanding the Basics of Electrocoat. Kelly Moore Development Chemist

IN-TANK TECHNOLOGY INSTRUCTIONS FOR USING FLO KING IN-TANK CARBON BAG

3 Scotch-Weld TM. Structural Adhesive Primer EC Technical Data August, 2002

Name Honors Chemistry / /

VELCRO brand Adhesives. p re s s u re sensitive, fire re t a rd a n t, solve n t and heat ac t i v a t e d

Electricity and Chemistry

high efficiency ~ simple package ~ proven reliability ChromaPur Chromic Acid Purification Unit

To hold a large reserve of metal ions in the soluble form.

THERMACLEAN Product Line Guide

Auditing of Composite and Metal Bonding Facilities. Introduction

Cupric Chloride Etch Regeneration: Tri-Star Technologies Company, Inc. 1997

Potentiometric analysis of brass and bronze plating baths

ZERO Pollution Discharge

Removing Heavy Metals from Wastewater

PROCESSES TO REDUCE PRODUCTION COSTS

CLEARLYTE PLUS CATHODIC ELECTROPHORETIC CLEAR / TINTED CLCQUERING PROCESS

Midsun HVIC silicone is not affected by UV light, temperature, corrosive environments, or ATH pitting from dry band arcing.

Troubleshooting of Electrolytic Color Anodizing of Aluminum

POREX Tubular Membrane Filter Modules For Metal Contaminated Wastewater Treatment & Reclamation

PRODUCT DATA SHEET SP-3888

METAL FINISHING. (As per revised VTU syllabus: )

General Pollution Prevention Techniques for Plating Solutions

ASAHI KASEI EMD DFR SUNFORT TM

INSTRUCTIONS: CHLORIDE AND WATER HARDNESS (VERSENATE) METHOD PART No

Metal Finishing Application

Salinity in Seawater

DuPont Riston Special FX Series - FX515

Material Safety Data Sheet

WHAT TO DO? ELECTROPLATING OR METAL SPRAYING?

Owners Manual Models: 200-RODI4-XXX. US Water Systems 4 Stage RO/DI System Installation and Maintenance Manual.

PURDUE UNIVERSITY ELECTROPLATING GOLD PROCESS SPECIFICATION RF LAB. Professor in charge: William Chappell MSEE 289

ELECTROPHORETIC. What Is Electrocoating? Types of Electrocoat

Technical Data Sheet CHEMEON TCP-HF

Transcription:

Alkaline Non-Cyanide Zinc Plating Process E-Brite Ultra Alk E-Brite Ultra Alk is a thoroughly tested, stable and production proven zinc plating brightener process. It is suitable for either rack or barrel plating. E-Brite Ultra Alk provides better zinc metal distribution than traditional alkaline zinc or chloride zinc plating systems. Operating parameters are wide and therefore it is an easy process to maintain. E-Brite Ultra-Alk deposits are ultra bright and ductile over a wide current density range. It plates mirror bright to 120 ASF. The deposits readily accept all chromate conversion coatings. The process was developed to replace cyanide zinc plating without sacrificing the quality of the zinc deposit. Waste treatment is simplified and requires only a simple ph adjustment to precipitate zinc metal as zinc hydroxide. Advantages Ultra bright zinc deposit. Approaching that of chloride zinc. Excellent ductility and adhesion. Maintains ductility even with thicknesses in excess of one mil. A low stress deposit. Superior zinc deposit plate distribution. Excellent chromate conversion coating receptivity. Zinc deposit appearance is comparable to cyanide or chloride zinc. Operates within wide range of bath chemistry. Temperature tolerance up to 120F, which reduces cooling costs. Excellent brightener stability and brightener life. Suitable for either rack or barrel plating. A reliable, easy to maintain process. It contains no chelating agents. Material Information 1. E-Brite Ultra Alk CR is a liquid carrier product that provides refining and partial brightness to zinc deposit. It is added with a pace feeder at 50-100 ml per 1000 amp hour. 2. E-Brite Ultra Alk B is a liquid product that provides low current density (LCD) brightness and luster to zinc deposit in LCD areas. 3. E-Brite Ultra Alk P is a liquid purifier product that provides refining enhancement in high and mid current densities and it also treats heavy metals impurities. 4. E-Brite Ultra Alk GLU is a liquid carrier type product that achieves overall brightness to the zinc deposit.

5. Preferably deionized or distilled water should be used when preparing a new solution. Consult with your EPI representative. 6. Sodium Hydroxide (caustic) must be Membrane or approved powder. Equipment: Plating Tank A low carbon steel tank may be used. To prevent stray current interference, a steel tank lined with Koroseal or an approved lining is preferred over an unlined steel tank. Steel Anodes: Zinc Anodes: Anode Baskets: 0.125 0.375 inch thick low carbon steel plate or low carbon steel grating placed wall to wall in plating tank. All steel anodes are used when a zinc generating tank is used. See page 7and 8 for zinc generator design. Used only when not using a zinc generating tank (SHG 99.99% pure). Typically a combination of steel and zinc anodes are used. Mild steel, if using zinc anodes in the plating tank. Anode Bars: Agitation: Filtration: Rectifier: Bussing: Temp. Control: Ventilation: Submerged regular low carbon steel anode bars are used. If copper anode bars are used, they should be well above the plating solution and covered with plastic over entire bar except contact areas or plated with nickel. Normally cathode movement along with 2-3 turnovers per hour of solution movement is recommended for rack plating operations. Use 5-15 micron poly-pro filter cartridges or plates packed with a filter aid or use a sand filter. Filtration speed should be 1 to 2 tank turnovers per hour. Barrel: Up to 18 volts remote or tap switch. Rack: Up to 12 volts remote control is suggested. Must be adequate to carry high current. It is suggested that the tank be equipped with heating and cooling coils to keep plating solution temperature in operating range of 70-120F. Required Equipment: Zinc Generator Tank A zinc generator is commonly used to supply zinc to the plating solution. Zinc metal is plated onto the parts from the plating solution and this action causes a reduction in zinc metal concentration in the plating solution. The zinc generator will provide zinc metal to the plating solution to maintain the zinc metal concentration. The zinc generator tank is off line and does not require any external power to generate the zinc. Zinc anodes in contact with steel creates a galvanic reaction and dissolves the zinc into solution. The zinc generator tank is made of low carbon steel. The Plating tank is connected to the generator with PVC or plastic pipe. It is highly recommended that a rubber mat be used under the zinc generator tank as insulation to prevent stray current. The zinc generator tank is also equipped with valves, a filtration unit and a pump for optimum efficiency and ease of operation. Sketches of generator tanks are given on page 7 and 8 of this technical data sheet. 2

The zinc metal level in the plating solution is easily maintained with adjustment of the zinc anode area in the zinc generator tank. The generator tank volume may be 10-20% or in some rare cases up to 50% of the plating solution. The zinc generator tank size depends on many factors, such as number of hours of plating operation, low or high drag-out, operating bath temperature and current density, etc. Zinc Anodes: Agitation: Anode Baskets: Note: Plating Cycle Use special high grade (SHG 99.99% pure) zinc balls or slab zinc anodes in the zinc generator tank. Air or solution pumps (submersible or exterior) must be used to move the zincate solution throughout the tank continuously. Otherwise a hard crust will form on the anodes which will have to be removed. Low carbon steel baskets are required in the generator tank. Do not use titanium anode baskets. Consult your EPI representative for details on equipment for the plating and generator tanks. 1. Soak clean with E-Kleen SR product line or E-Kleen 157. Consult with EPI. 2. Rinse 3. Anodic electroclean (parts are positive) with E-Kleen SR 1020 or 129/129-L. Consult with EPI. 4. Rinse 5. Optional permanganate descale for heat treat or weld scales with E-Pik 272 solution. 6. Rinse 7. Acid Activation. 30% to 50% HCl (Muriatic Acid) with E-Hib 979. 8. A still conditioning rinse with 2-4 oz/gal of Sodium Hydroxide and 1-2% by volume of E-Brite Ultra Alk GLU. This will neutralize any acid film and reduce drag-in of iron into the plating solution. 9. Plate in E-Brite Ultra Alk solution 10. Rinse 11. Rinse 12. 0.5% Nitric Acid bright dip 13. Chromate conversion finish with E-Chrome/E-PASSivate hexavalent or trivalent chromates or with E-Tec non chromate sealant. 14. Rinse 15. Rinse 16. Dry Operating Parameters and Conditions Optimum Range Zinc Metal 15 g/l (2.0 opg) 7.5-22.5 g/l (1.0 to 3.0 opg) Sodium Hydroxide (total) 135 g/l (18.0 opg) 120-156 g/l (16 to 21 opg) Sodium hydroxide to zinc metal ratio 10:1 Rack, 7:1 Barrel 9.5-10.5 Rack; 6.5-7.5 Barrel Sodium Carbonate < 75 g/l (10 opg) 0-75 g/l (10 opg) E-Brite Ultra Alk CR 2.0% 1.00 to 2.50% by volume E-Brite Ultra Alk B 0.05% 0.05 to 0.08% by volume E-Brite Ultra Alk P 0.50% 0.3 to 0.8% by volume 3

E-Brite Ultra Alk GLU 1.2% by volume 1.0-1.5% by volume Temperature 80 90 F 75-120F Current Density Range 20 ASF 2 120 ASF Voltage 3 18 volts Anode to Cathode Ratio 1:1-2:1 Optional E-Brite Ultra Alk WC water conditioner if needed: 1.0 to 2.0 oz/gallon. It is a powdered product that reduces water hardness that can cause matte, dull or hazy appearance. Use depends upon water hardness. E-Brite Ultra Alk FS fume suppressant if needed: 1 pint/1000 gallons. Used with tanks with poor ventilation. Bath Make Up Caution: Wear protective rubber apron, rubber gloves, and rubber boots, OSHA approved face and eye protection prior to beginning the bath make up. 1. Clean and leach out the plating tank with ~ 4.0 oz/gal Sodium Hydroxide for 12 hours and then rinse the tank with clean water. Also clean bus bars. 2. Add deionized water to clean tank to ~ 60% of the final volume. 3. Add recommended level of E-Brite Ultra-Alk Z zincate solution. 4. Add deionized water to ~ 90% of the final volume 5. Add the recommended amount of E-Brite Ultra-Alk CR, B and P 6. Analyze Sodium Hydroxide and zinc level and adjust if needed. 7. Run Hull Cell plating test to evaluate zinc deposit appearance. Note: New bath make up can also be accomplished by using zinc balls in mild steel baskets and sodium hydroxide. Please contact EPI to obtain detailed information for this second method. We do not recommend this method as high levels of contaminants may exist and therefore solution may require electrolysis for some time, which can cause a delay in production. Solution Maintenance E-Brite Ultra Alk CR E-Brite Ultra Alk B E-Brite Ultra-Alk P Sodium Hydroxide Zinc Metal Add 50-100 ml per 1000 amp hour. By Hull Cell appearance and distribution. One (1) amp for 30 minutes. By Hull Cell observing low current density (LCD) appearance and amp hours plated. By Hull Cell appearance. One (1) amp for 30 minutes. By Chemical analysis. Use only membrane or approved powder caustic. Maintain a minimum of 10:1 NaOH: zinc ratio for Rack, 7:1 for Barrel By chemical analysis. Concentration adjusted by zinc anode area in the zinc generator tank or zinc anode area in the plating solution. Frequent analysis must be performed at regular intervals on the plating and generating solutions. 4

Sodium Carbonate By chemical analysis. The carbonate level will slowly increase. The maximum recommended amount is 75-90 grams/liter. Dilute the bath by 50% and replenish with the appropriate amount of zincate solution from the generating tank, sodium hydroxide, Alk- GLU, CR, B & P. High carbonates results in lower bath efficiency and slower plating speeds. Analytical Controls Zinc Analysis 1. Pipette 5 ml bath sample into a 500 ml Erlenmeyer Flask. 2. Add 5 ml of 30% Hydrochloric Acid 3. Add ~ 150 ml of distilled or deionized water 4. Add 30 ml Acetate buffer (double strength) 5. Add 0.5 ml Xylenol Orange indicator to give a fuchsia color (bright reddish pink) 6. Titrate with 0.1M Disodium EDTA solution until the color changes to yellow. This change is very rapid, proceed very slowly. 7. Calculation: ml of EDTA titration x 0.176 = zinc metal in oz/gal oz/gal zinc metal x 7.5 = zinc metal in g/l Sodium Hydroxide (Caustic) Analysis 1. Pipette 5 ml of the bath into an Erlenmeyer flask. 2. Add water to 100 ml. 3. Add with a measuring cylinder 20 ml of 10% barium chloride solution and swirl. 4. Add 2-3 drops phenolphthalein indicator. 5. Titrate with 1 N hydrochloric acid until the red color disappears. Calculation: oz/gal NaOH = ml of titration X 1.066. Sodium Carbonate Analysis 1. Pipette 10 ml of bath sample into a 250 ml Erlenmeyer Flask. 2. Add a.) 100 ml of hot deionized water (120-140F) b.) 35 ml of 10% Barium Nitrate solution and allow to settle 3. Filter out the precipitate and wash the filter 2 3 times with hot deionized water. 4. Transfer carefully filter paper with precipitates into a 250 ml glass beaker and add 100 ml room temperature deionized water. Add few drops of Methyl Orange Indicator. 5. Titrate with 1.0N Hydrochloric Acid to end point from Orange to Pink. 6. Calculation: ml of HCl x 0.707 = oz/gal Sodium Carbonate Caustic to Zinc Metal Ratio 1. Calculation: oz/gal caustic oz/gal zinc metal Waste Treatment 1. Reduce ph with dilute acid to 9.0. Mix vigorously. 2. Filter out or clarify and decant the precipitated zinc hydroxide. 5

3. Adjust ph of the filtrate according to the local environmental pollution control regulations before discharge. Note: The use of EPI Coagulant and EPI Polymer will significantly reduce sludge volume. Caution: Alkaline non-cyanide plating solutions containing E-Brite Ultra ALK addition agents ( CR, B, P, WC and FS, Z ) are hazardous and may be fatal if swallowed. They can cause severe irritation to skin and eyes on contact. Persons who handle or work with this solution must wear OSHA approved chemical resistant safety goggles or full-face shield, rubber gloves, rubber apron and rubber boots. If solution is swallowed, seek medical attention immediately. In case of contact with eyes, immediately flush with cold water for approximately 15 minutes and seek medical attention. In case of contact with skin wash it with cold running water for 5 15 minutes and seek medical attention if necessary. Read and understand the MSDS for each of the EPI products before working with them. Packaging Of Additives 5 and 55 gallon non returnable containers 275 gallon tote IMPORTANT NOTICE! For Industrial Use Only The following is made in lieu of all warranties, expressed or implied, including the implied warranties of merchantability and fitness for purpose: seller s and manufacturer s only obligation shall be to replace such quantity of the product as proved to be defective. Before using, user shall determine the suitability of the product for its intended use, and user assumes all risk and liability whatsoever in connection therewith. Neither seller nor manufacturer shall be liable either in tort or in contract for any loss or damage, direct, incidental or consequential, arising out of the use or the inability to use the product. 6

E-Brite Ultra Alk Maintaining The Zinc Concentration The zinc in the plating solution can be replenished from zinc anodes in the Plating solution or by dissolving zinc anodes in a separate zinc generator tank. If zinc anodes are used in the plating solution they will have to be removed Periodically to keep the zinc concentration within range or the solution must be pumped out when the solution is not being plated. Therefore, the preferred method is using a zinc generator tank. Zinc Generating Tank Mechanical Method Zinc Balls in mild steel anode baskets (removable) From Plating Tank Top View Filter Unit 10-15 Micron Polypro Media Preferred Or Sand Filter To Plating Tank Anode baskets and anodes must be cleaned before use. The dissolution rate of zinc in an alkaline zinc solution when in contact with steel at 75 F is approximately 1.2 oz per sq.ft. per hour. This figure can be used to determine the estimated surface area of the zinc anodes in the generator tank. Also, sq.ft. of zinc anode area = (total amps) x 0.02. The temperature and caustic concentration will have a great affect on the dissolution rate. Typically the volume of a zinc generator tank is 10 to 20% of the volume of the plating tank. Consult your EPI representative for specific recommendations. See page 8 for an automatic method. 7

Zinc Generating Tank: Automatic Method Filter draws from either the plater or generator based on an ampere hour meter off the plating rectifier. When the filter pumps from the generator tank, plating solution flows back from the plate tank through the return pipe. Solenoid Valve Filter Return Line Filter Return Generator Tank Plate Tank Pump Optional oil skimming tank installed in return line This pump continually re-circulates the generator solution over the weir. 1/21/16