Pipe Supports Comparison

Similar documents
NEW! THE FLEXIBLE PROFESSIONAL INSULATION WITH REVOLUTIONARY CHARACTERISTICS. even easier to use

armaflex cryogenic systems

REFERENCE ARMA-CHEK SILVER

NEW THE FLEXIBLE INSULATION WITH ANTIMICROBIAL PROTECTION

K-FLEX K-FONIK INDUSTRIAL

EFRIGERATION INSTALLATION GUIDE

SECTION PIPING INSULATION

SECTION HVAC INSULATION

1. Division 23 Section "Hangers and Supports for HVAC Piping and Equipment" for pipe insulation shields and protection saddles.

L'ISOLANTE K-FLEX. LNG applications Manual

FOR FURTHER INFORMATION ON THE KOOLTHERM RANGE OF PRODUCTS PLEASE TELEPHONE THE KINGSPAN TECHNICAL SERVICES DEPARTMENT (01457)

DSC BUILDING 1200 ALTERATIONS OCTOBER 2011 SECTION DUCT INSULATION

FIRE STATION 55 June 14, 2010

Pipe and Equipment Insulations. Zeston. PVC Insulated Fitting Covers Installation Instructions for Hot, Cold and USDA Piping Systems

Design & Construction Standards, Revised January

Project Specification. Tarec. Insulation for the LNG, Petrochemical and Process Industries

HVAC INSULATION. A. General Requirements for Flexible Elastomeric Insulation: 3. Use pre-molded roll on pipe sizes 3.5" and below.

hüma PARKETTSYSTEM GmbH INSTALLATION GUIDE

J41 Reinforced bitumen membrane roof coverings

SECTION HVAC PIPING INSULATION

J41 Reinforced bitumen membrane roof coverings

Cold Work Cladding Fabrication & Application

Mechanical Insulation for Refrigeration Systems

ACOUSTICAL INSULATION (LAGGING) FOR PIPING AND EQUIPMENT

GLAUNACH THE SILENCER HANDBOOK INSULATION SUPPLEMENTARY ACOUSTIC SHIELDING OF SILENCERS, PIPES & CO GLAUNACH GMBH ALL RIGHTS RESERVED -

THE FLEXIBLE INSULATION SYSTEM TO PREVENT CONDENSATION AND ENERGY LOSSES

European Technical Assessment. ETA-16/0320 of Member of. General part

K-FLEX K-FLEX ST 74 A NEW GENERATION OF INSULATION MATERIALS

Specification. Project Name: Project reference: Written: by: Cathal Quinn Tel:

A. Deliver material to job site in original, nonbroken, factory packaging, labeled with manufacturer's density and thickness.

Light-Metal Roof Edge, Raised

University of Delaware

PLATON RUGGED, DIMPLED HIGH-DENSITY POLYETHYLENE (HDPE) MEMBRANE THAT KEEPS FOUNDATIONS AND FLOORING DRY ADVANCED TECHNOLOGY EASY INSTALLATION

Channel Drain Shower Base. Aqua Line pro. Installation Instructions

Cryogenic Pipe Support Systems

Hoesch isodach integral Technical information

ICC-ES Evaluation Report Reissued May 1, 2010 This report is subject to re-examination in two years.

TI-LINE TILUX DURABASE. Borderless Shower Areas

Sikaflex 221 is a high-adhesion, polyurethane-based sealing compound for Low-odour

EasylationWall. External Wall Insulation System. bringing european innovation

Insulating systems used in agricultural and industrial buildings

FIREPRO FIRE DUCT SYSTEMS Single layer fire protection for rectangular, circular and oval ducts.

INSTALLATION GUIDELINES for ISO-C1 POLYISOCYANURATE MECHANICAL INSULATION for LIQUEFIED NATURAL GAS (LNG) CRYOGENIC REFRIGERATION CHILLED WATER

Economically Priced Insulation For Domestic Heating & Plumbing Economically priced insulation for domestic heating and plumbing

MECHANICAL INSULATION

SPECIFICATION GUIDELINES FOR THE USE OF CRYOGEL Z ON COLD PIPING AND EQUIPMENT

84 Lapping & Jointing 86 Service Pipe Penetrations 87 Sealing to Cavity Wall Constructions 88 Protecting Membranes System Components.

Data Sheet 832 Englisch

PIPEWORK INSULATION. 14/ Page 1 of 10 Pipework Insulation Rev D

EKVÜ seminar 11 mar 2016 Armacell/ Armaflex. Tallinn/ Estonia Petri Ojanen

FIRESTOP JOINT SPRAY CFS-SP WB. 2mm (0.079") WET FILM ± 7.5 ± 5

Xtratherm Thin-R Partial Fill Cavity Wall Board (XT/CW Grade)

NCCER Progress Blvd, Alachua, Florida Tel: (888)

Duct Insulation. Kingspan. Insulation RIGID INSULATION FOR OUTDOOR RECTANGULAR, CIRCULAR AND FLAT OVAL HVAC DUCTWORK. Low Energy Low Carbon Buildings

OPTIWIN MOTURA. Technical Description. Synopsis:

SECTION 07530CP EPDM MEMBRANE ROOFING

HVAC Piping Insulation- FIBERGLAS Insulation

Roofing. Carrier Membrane SA. Self-adhesive Carrier Membrane. Product Description. Tests. Product Data. Form. Storage

PROTEKTOR PROFILES FOR EXTERNAL THERMAL INSULATION COMPOSITE SYSTEMS

H series. for upper balconies DN 100. DN 100 Vers. a X X. Partial unit Side drain

Regupol CONSTRUCTION. Regupol BA. Heavy duty screed isolation. Regupol BA. Excellent impact performance.

K-FLEX K-FLEX ST 84 A N E W G E N E R A T I O N O F I N S U L A T I O N M A T E R I A L S

SECTION PRE-ENGINEERED BUILDING INSULATION

Valance Installation. For Units with Beam Style Coils

SECTION HANGERS AND SUPPORTS FOR PLUMBING

Gas Protection System Components

SECTION HANGERS AND SUPPORTS FOR PLUMBING PIPING AND EQUIPMENT

The right fit for everyone. Only the best for all

BuildingName The Description of the Project P DOCUMENTS

SPECIFICATION FOR COLD INSULATION

COMP ONENT CATA LO GUE FOR INDUSTRIAL BUILDINGS

Ammonia. Product performance for insulation of ammonia piping

Injectable hose with integral valves for sealing construction joints in watertight structures

June Residential Refurbishment Basements

FLEXIBLE PREINSULATED PIPES

VPA 8 Status: October 2014 Test Certificates. Containers made of plastic with bung hole or removable lid 4. Fibre drums 5

SECTION B. Product Data: Provide manufacturer's standard details and installation instructions.

Mounting instructions. novotegra for trapezoidal metal - roof parallel

Labels make the brand. krones Contiroll. Reel-fed labelling

HANGERS AND SUPPORTS FOR HVAC PIPING AND EQUIPMENT SECTION HANGERS AND SUPPORTS FOR HVAC PIPING AND EQUIPMENT

Tube Insulation. Fiber Free

Daytona Beach Pier Building Renovation Jun 2010

BBA 001 Documents included under the scope of BBA s ISO UKAS accreditation

Xtratherm Thin-R Thermal Liner (XT/TL Grade)

GENERAL GUIDELINE SikaMembran System / VERSION 1 / SIKA SERVICES AG

NOMA Parkett. Engineering your security.

INSTALLATION MANUAL PIPE SUPPORT

Construction. SikaMembran system Vapour control/waterproofing sheet system for ventilated curtain walling

DUCTWRAP AND DUCTSLAB For the thermal insulation of ductwork and water storage tanks.

FireMaster FastWrap XL

Copper Tube Folderv3.indd 2 16/5/07 16:27:03

PIP INSA1000 Acoustic Insulation Systems Specification

Construction. S-Vap 5000E SA Self-adhesive Vapour Barrier. Product Description

LISTING INFORMATION OF International Fireproof Technology Inc. - Joint Systems SPEC ID: 43848

SMART FIXING SYSTEMS profiles pro ofilees

Endotherme Mat ES-5A-12

Transcription:

PIPE SUPPORTS: Comparison of the installation costs for various systems ARMAFIX The easy to install and cost effective solution to prevent thermal bridging at the pipe bracket in low-temperature applications.

When insulating refrigeration pipes, it is essential to ensure that thermal bridging in the vicinity of the pipe bracket is prevented. At the same time, the following conditions must be fulfilled in order to ensure the long-term performance of this part of the insulation system: 1. The vapour barrier (µ-value or sd-value) of the pipe support must at least match the adjoining pipe insulation. 2. To prevent condensation forming, the load-bearing segments must be at least as thick as the adjoining layer of insulation material. 3. The load-bearing segment must be sufficiently compression-proof taking into account the distance between clamps and the diameter of the pipe. 4. All seams and joins must be glued and sealed reliably and permanently. 5. The pipe loads must be distributed equally on the load-bearing segments The maximum permitted distances stipulated by the manufacturer must be heeded. Just as the weakest link determines the strength of a chain, so pipe supports in low-temperature applications can be the weakest point in the insulation system. The pipe supports fulfil all the requirements made of a practical pipe suspension system. They enable the insulation to be joined to the pipe support reliably and simply even under building site conditions. They reliable prevent thermal bridges ( cold bridges ) occurring and moisture being absorbed into the insulation system. Using the pipe support saves time and money, both in comparison to retrofitting insulation to pipe brackets (a practice which is still common) and also in comparison to other load-bearing solutions. pipe hanger now comps with an easy, plug & play pipe clamp system. When using other pipe supports in combination with Armaflex the following assembly instructions must be heeded: + = Production/m Fast installation with AF/Armaflex + Time saving = profit Time-consuming installation using 2-part / standard pipe supports Installation time

pipe support The reliable solution for preventing thermal bridges in the vicinity of pipe supports. 1. Snap pipe support around the pipe, remove the protective film and join the longitudinal edges together. No additional glue or mastic is necessary. 1. Seal off the pipe support. 2. Glue Armaflex to the pipe support. comes with a convenient selfadhesive closure. 8 6 4 2 * outer pipe diameter:35 mm. AF Armaflex- or NH/Armaflex insulation in combination with the pipe support provides a secure system solution thanks to the perfect match

Pipe clamp without thermal isolation When a pipe clamp without thermal insulation is used, additional steps with retrofit insulltion need to be taken to avoid cold bridges and condensation. 1. Attach clamp. Armaflex pipe insulation Strip of Armaflex 1. Glue Armaflex tube/sheet material professionally up to the clamp and seal off. 2. Glue strip of Armaflex in the required insulation thickness to the clamp taking care to avoid tension. Ensure that it overlaps the Armaflex tube by 5 cm. 3. Glue overlap to adjoining insulation. 4. Insulate approx. 15 cm of the threaded rod, seal off the upper surface and glue the lower surface to the jacket. Insulation Threaded rod Take measures to prevent moisture ingress 8 6 4 2 Pipe clamp without thermal isolation * Outer pipe diameter: 35 mm In addition: 12 cm-wide strip of Armaflex. Pipe clamp with or without rubber insert. Risk of condensation

(Two-part) PUR/PIR shell with glass-fibre reinforced ALU facing 1. Snap shell onto the pipe and carefully remove the protective film of the selfadhesive surfaces. 2. Glue seams. 3. Install clamp. 4. CAUTION: Do not damage the facing. = PUR/PIR Glue seams 1. Check for damage to the vapour barrier; if necessary replace the pipe support. 2. Glue Armaflex professionally to the refrigeration clamp. To do so clean the faces of the clamp with Armaflex special cleaner. Apply the Armaflex adhesive to the faces and allow the prime coat to dry. Apply a thin, even layer of adhesive to the PIR and Armaflex surfaces to be glued, allow to it outgas, join surfaces carefully and press together firmly. When carrying out the butt joints under compression it is also possible to use the wet-seal method. 3. Secure the butt joints with an additional strip of Armaflex in the required insulation thickness. Fully glue the strip with overlap. Strip of Armaflex Aluminium foil Additionally secure the PUR/PIR / Armaflex join with a strip 8 6 4 2 PIR shell with glass-fibre reinforced ALU facing * Outer pipe diameter: 35 mm PUR/PIR pipe support In addition: 12 cm-wide = PUR/PIR strip of Armaflex

HD-PUR refrigeration clamp with steel clip laid in the foam 1. Before installing, apply a ring of sealing compound to the load bearing surface and on the joining surfaces of both clamp parts and then install. Ensure that the faces are free of sealing compound. Securing the seam with sealing compound 1. Clean the surface of the refrigeration clamp which is to be glued with Armaflex special cleaner. 2. Apply Armaflex adhesive to the surface to be glued. Allow prime coat to dry. 3. Apply a thin, even coat of adhesive to the HD-PUR and Armaflex surfaces to be glued, allow it to outgas, join the surfaces carefully and press together firmly. 4. When carrying out the butt joints under compression it is also possible to use the wet-seal method if the HD-PUR surfaces to be glued have been primed. 5. Depending on the value of HD-PUR pipe support, apply a double layer of Armaflex to achieve the height of the HD-PUR pipe support. 6. Secure the butt joins by fully gluing an overlapping strip of Armaflex. Risk of condensation Before the insulation material is applied the faces of the pipe support must be cleaned and roughened. 3 Sealing compound Metal clamp Polyurethane rigid foam 2 HD - PUR Shell * Outer pipe diameter: 35 mm

PUR/PIR shells with thin layer of elastomeric insulation glued to the faces, covered with protective foil 1. Open pipe support. 2. Apply glue to the joining surfaces of the half-shells. 3. Install pipe support and glue overlap of the covering. 1. Glue Armaflex to the pipe support. 2. Additionally secure the butt joints between Armaflex and the pipe support with self-adhesive Armaflex tape. Glue seams = PUR/PIR Self-adhesive AF/Armaflex tape = PUR/PIR 8 6 4 2 PIR shells with thin layer of elastomeric insulation glued to the faces, covered with protective foil * Outer pipe diameter: 35 mm

Secure System Solution Conclusion The combination of Armaflex with saves a considerable amount of time and money. In addition, if the project complies with some defined requirements, additional warranty will be given on the functionally relevant properties of the products and on the installation work. All data and technical information are based on results achieved under typical application conditions. Recipients of this information should, in their own interest and responsibility, clarify with us in due time whether or not the data and information apply to the intended application area. Installation instructions are available in our Armaflex installation manual. Please consult our Customer Service Center before insulating stainless steels. Adhesive Armaflex 52 must be used to guarantee proper installation. For some refrigerants the discharge temperature may exceed +5 C, consult Customer Service Center for further information. Armacell Enterprise GmbH Robert-Bosch-Straße D-48153 Münster Postfach 11 29 481 Münster Telephone: +49 () 251 / 76 3 Fax: +49 () 251 / 76 3 448 www.armacell.com info.de@armacell.com Copyright: Armacell Enterprise GmbH Subject to changes Printed in Europe 6-1.com-8-EN