MicroMetrics. A Precision Contact Stress Sensor for Monitoring Swelling in Li-Ion Cells

Similar documents
Microfabrication of Heterogeneous, Optimized Compliant Mechanisms SUNFEST 2001 Luo Chen Advisor: Professor G.K. Ananthasuresh

Agilent 4339B/4349B High Resistance Meters Technical Overview

1. Introduction - Daiichi Jitsugyo Inc. (DJK) 2. Introduction - Daiichi Jitsugyo (America) (DJA) 3. Equipment Line-up for Battery Cell Manufacturing

Packaging Commercial CMOS Chips for Lab on a Chip Integration

UNCONVENTIONAL MACHINING PROCESS UNIT 1 INTRODUCTION. Prepared by S. SENTHIL KUMAR AP / MECH SVCET

FLUXUS F/G601 and F/G608

FABRICATION PROCESSES FOR MAGNETIC MICROACTUATORS WITH POLYSILICON FLEXURES. Jack W. Judy and Richard S. Muller

Anisotropic Conductive Films (ACFs)

On-line corrosion mapping of industrial plant using advanced electrical resistance techniques

RemScan TM SCOPE OF WORK. Rapid Measurement of Petroleum Hydrocarbons in Soil S /16

Water flow measurement in the oil and gas industry

Laser Ultrasonics 2010 Laser-based ultrasonic-emission sensor for in-process monitoring during high-speed laser welding

Application Note. 4D Study of Silicon Anode Volumetric Changes in a Coin Cell Battery using X-ray Microscopy

Quantum Dot applications in Fluorescence Imaging for Calibration and Molecular Imaging

Lecture 7 CMOS MEMS. CMOS MEMS Processes. CMOS MEMS Processes. Why CMOS-MEMS? Agenda: CMOS MEMS: Fabrication. MEMS structures can be made

3SP_CO_1000 Package

HI EPA Compliant Turbidity Meter HI EPA Compliant Turbidity and Chlorine Meter

Poly-SiGe MEMS actuators for adaptive optics

Reference thermometer Model CTP5000

Single Pulse Resistance Welder Instruction Pamphlet CD125SP High Accuracy CD Welder

BONDING OF MULTIPLE WAFERS FOR HIGH THROUGHPUT LED PRODUCTION. S. Sood and A. Wong

Leveraging the Precision of Electroforming over Alternative Processes When Developing Nano-scale Structures

Pressure transducers DMU 02 Vario (flush)

Applications of High-Performance MEMS Pressure Sensors Based on Dissolved Wafer Process

Radioisotope Batteries. Jake Blanchard University of Wisconsin April 2010

USE OF STRETCH SENSORS TO DETECT THE FORMATION OF AN ENDOSCOPIC LOOP

SURFACE TEMPERATURE SENSORS

Tantalum Wet Electrolytic Capacitor

HMA GROUP AUSTRALIA - NEW ZEALAND - INDONESIA - SOUTH AFRICA SINCE 1966

There are basically two approaches for bulk micromachining of. silicon, wet and dry. Wet bulk micromachining is usually carried out

MPM 100 Monitor Product Description Guide

Installation, Operation & Maintenance Manual

Electroactive Polymer for Controlling Overcharge in Lithium-Ion Batteries

NanoSystemsEngineering: NanoNose Final Status, March 2011

Application Note. MadgeTech, Inc. (603) Phone (603) Fax 6 Warner Road Warner NH 03278

Laser Micromachining for Industrial Applications and R&D. 3D-Micromac AG. Symposium on Smart Integrated Systems in Chemnitz. 3D-Micromac AG

XSTi Standby UPS. 400VA, 600VA, 800VA Models. User & Installation Manual

HI GPS Multiparameter Meter. With great products, come great results HI 9829

Full-Scale Cyclic Bending Test of Strongwell s SE28 FRP Pole

Graphite Foam for Cooling of Automotive Power Electronics

Lab #1a Temperature Measurement

Lab Exercise #2: Tension Testing (Uniaxial Stress)

Compact flue gas analyser: testo 300 M-I

Optimizing Strain Gage Excitation Levels

Meteorology 432. Thermometry Spring 2013

TEWA ELECTRONICS GROUP HIGH PRECISION NTC THERMISTORS AND TEMPERATURE SENSORS

TGV and Integrated Electronics

Novel concept of rechargeable battery using iron oxide nanorods. anode and nickel hydroxide cathode in aqueous electrolyte

ENGLISH Datasheet JIS Miniature Thermocouple Connector In-Line Plugs Types K, J, T, E, R/S & B (JIS Colour Code)

Micro-Electro-Mechanical Systems (MEMS) Fabrication. Special Process Modules for MEMS. Principle of Sensing and Actuation

Effect Of Oxidation In Tin Coated Copper Bus Connections

A Novel NDT Method for Measuring Thickness of Brush-Electroplated. Nickel Coating on Ferrous Metal Sueface

INTRODUCTION TO ELECTROCHEMISTRY: CURRENT, VOLTAGE, & BATTERIES. Introduction. Electrochemistry Revised 4/28/14

Infrared thermometer. testo 835 fast, accurate infrared measuring instruments for trade and industry. Data sheet testo 835

Combined Hardness Tester NOVOTEST T-UD2

A Multilayer Process for 3D-Molded-Interconnect-Devices to Enable the Assembly of Area-Array Based Package Types

ASME PTC Flow Measurement

Combined Hardness Tester NOVOTEST T-UD3 NEW

Elcometer 118/2. Moisture Meter. Operating Instructions

UCI Hardness Tester NOVOTEST T-U3

Utility Flow Metering for Steam and Heated/Chilled Water: A Tutorial. Richard Gruskos Flow Products Manager Kessler Ellis Products

Model BF 720 Incubators Avantgarde.Line with forced convection

Hawser Hooks for Tandem or Single Point Mooring

2% & (+ 2% PSI.

Silicon Wafer Processing PAKAGING AND TEST

Sensor. Device that converts a non-electrical physical or chemical quantity into an electrical signal. Sensor Processor Display Output signal

SCIEX Anion Analysis Kit For P/ACE MDQ and P/ACE MDQ plus Capillary Electrophoresis Systems. Instruction Guide

Industrial Solutions. Quality is Our Driving Force. interfaceforce.com

Features. = +25 C, 50 Ohm System

Nickel Electroplating

UCI Hardness Tester NOVOTEST T-U3 NEW

Process Development MEGTEC. Advancing Innovative Coated Materials

ILMK 382. Stainless Steel Probe. Ceramic Sensor. accuracy according to IEC 60770: standard: 0.35 % FSO option: 0.25 % FSO.

Construction of a Seebeck Envelope Calorimeter and Reproducibility of Excess Heat

Evaluation of Mechanical Properties of Hard Coatings

GLOBAL QUALITY SOLUTIONS PACKAGE INTEGRITY SEAL INTEGRITY LEAK DETECTION

Volume Change from Materials to Cell Level and Its Influence on Battery Lifetime

Shur-Shot X-Proof Hydrogen Fluoride Alarm Operations Manual

testo 330 Flue gas analysis with increased convenience and safety

Model FD 115 Drying and heating chambers Avantgarde.Line with forced convection

Calorimetry of Energy-Efficient Glow Discharge Apparatus Design and Calibration

Implantable Microelectronic Devices

Moisture analyzers (moisture meters) FIZEPR-SW100

Morgan State University CE STRUCTURES AREA LABORATORIES

Heated FID 109A. Rack Mount/Table Top NMGOC Analyzer

Flexible Carrier Enables Automated Test-in-Tray. Dr. Tom Di Stefano Centipede Systems

Odyssey Conductivity & Temperature Logger.

architectural lighting

XPM: High Speed Nanoindentation and Mechanical Property Mapping. Eric Hintsala, Ph.D

IPD Gauges. Water Temperature Oil Temperature Oil Pressure Fuel Pressure Amperes. The Standard for Quality, Innovation, Service and Support Since 1955

SECTION HEAT TRACING FOR PLUMBING PIPING

Model BF 260 Incubators Avantgarde.Line with forced convection

The content is broken down into the following outline:

Summer School June 2-4 th 2015

Preprint - Mechatronics 2008, Le Grand-Bornand, France, May

PURE WATER ph MEASUREMENT IN LOW CONDUCTIVITY SAMPLES

SIMULATION OF GASKET LEAKAGE AND CO-RELATION TO DESIGN

High Resolution Neuro-Electronic Interface System for Electrophysiological Experiments

BOROFLOAT & Glass Wafers: A Union of Inspiration & Quality

Note Flexible Four-in-one Micro Sensor for Reliability and 100-hour Durability Testing

Transcription:

MicroMetrics A Precision Contact Stress Sensor for Monitoring Swelling in Li-Ion Cells The 34 th Annual International Battery Seminar and Exhibition Fort Lauderdale, FL March 23, 2017 James Kaschmitter james.kasch@gmail.com (925) 570-7251

Introduction to MicroMetrics CSS MicroMetrics () Contact Stress Sensors (CSS) provide precision, repeatable measurement of contact stress between two surfaces A CSS is not a pressure sensor which measures gaseous or fluid pressure, and which are commonly available MicroMetrics CSS unparalleled attributes include: Ultra-thin form factor ( 150μm or 0.006 ) Holds factory calibration over life of the sensor so it can be permanently embedded in products Can also measure temperature, replacing thermistors or thermocouples Utilizes inexpensive MEMS (Micro-Electro-Mechanical Systems) chip technology mounted on commercially available flex cabling These attributes make it ideal for use in cells and/or battery packs: Laboratory measurements of swelling in developmental Li-ion cells/packs Embedded in production battery packs for life of the system for monitoring performance and early warning of cell or pack problems 2

SpectraPower - s Battery Affiliate MicroMetrics is an affiliate company of SpectraPower in Livermore, CA which performed the sensor/battery integration and testing: www.spectrapowerllc.com SpectraPower s battery lab performs contract R&D, cell and electrode builds, and consulting for major companies, government agencies, startups, etc. SpectraPower s capabilities for battery and supercapacitor development includes complete cell fabrication and test: 1) Powder preparation and slurry mixing 2) Electrode coating, drying and calendaring 3) Electrode prep and tabbing with ultrasonic welding 4) Cell assembly and electrolyte fill 5) Cell packaging and sealing 6) Formation, performance and cycle life testing 7) Environmental and safety testing SpectraPower s team has unique experience in high volume commercial manufacturing of all major form factors: 3

Sensor Specifications Accuracy: ±3% over the calibrated range (0 to 250psi) Maximum pressure: >1000 PSI Ultra-thin ( 150 microns)(1 600 Holds factory calibration over life of the sensor and temperature range Design life: 30 years Standard Calibration temperature range: -40 C to +70 C Maximum operating temperature range: -40 C to +125 C Maximum operating frequency: 500 khz (Sensor Only) 1 khz (Sensor Development Kits) Dynamic response 500 khz Cycle life >10,000 full load cycles Low-cost MEMS technology Can be supplied in custom arrays Flex Cable Interconnect CSS: Silicon MEMS Chip 4

CSS Holds Calibration over Cycling 5

Monitoring Swelling in Li-Ion Cells ~5Ah Si Anode Li-Ion Cell (note apparent swelling) Test Fixture w/css inserted between cell and clamping plates 6

Test Results: Swelling in Li_Ion Cells CSS monitoring swelling in a ~5Ahr pouch cell with Si anode Cycling at C/5 Simultaneous monitoring of cell voltage Small variations are due to day/ night temperature fluctuations ~10% increase in swelling pressure over 30 cycles Data shown is as-displayed by MicroMetrics-provided software 7

Measuring Cell Deflection with the CSS It is possible to obtain a measurement of the physical deflection of the side of a cell by using Hooke s law (the deformation of an elastic object is proportional to the stress applied to it) with pressure data collected from the CSS: P = ky, where P = pressure, k = spring constant, Y = displacement The following test setup was implemented to perform the test: Two similar pouch cells with silicon anodes were tested independently during charge-discharge cycling: First cell had an array of 6 contact stress sensors (CSS) Second cell had 3 mechanical deflection probes The cell with the CSS was inserted between metal plates with fingertight clamping pressure to provide uniform pressure The cell with the mechanical deflection probes was not clamped, the probes were positioned against the top of a metal cover plate that was allowed to move freely on top of the cell Both cells were cycled while taking measurements once per minute Tests were performed at Zeptor, Inc., Sunnyvale, CA, using Zeptor pouch cells 8

Pressure Measurement with CSS Change in Pressure during One Cycle Red and Blue are sensors on yellow tape Cell with 6 CSS in an array Note: yellow tape over tabs created a high spot Unexpected result right side of cell swells more than left side 9

Displacement Measurement Measurement of cell displacement using three mechanical probes Green front measurement was used for comparative analysis 10

Pressure Change vs. Cell Deflection Sensors on raised yellow tape showed higher spring constant A 11

Qualitative Comparison Average value for A (71.2) was used for comparison 12

Qualitative Comparison 13

Pressure can be Correlated to Deflection 14

Conclusions Deflection results obtained by measuring pressure on a cell with contact stress sensors agrees well with measurements taken using deflection probes Swelling pattern measured by 6 sensors correlates well with theoretical understanding of processes during cell charge/discharge (silicon anode swelling) More accurate results on deflection can be obtained wit h sensors using interface materials with known and more linear stress/strain mechanical behavior can supply custom sensor arrays designed to fit customer-specified cells 15

CSS Application in Battery Packs Mounting a thin CSS between cells provides detection of swelling due to internal gas generation Gas generation in pouch cells is an indication of potential cell failure due to internal parasitic reactions Poor quality leading to cell failure Potential safety event Contact Stress Sensor The CSS can double as a temperature sensor, minimizing cost, while monitoring both swelling and temperature 16

Application in Li-Ion Battery Packs One or more CSS sensors can be applied individually, or in arrays on the outside of pouch or prismatic cells to monitor swelling and temperature Signals from each CSS can be multiplexed to reduce wiring Multiple CSSs in array 17

CSS Eval Kits: Instrument for R&D Up to 16 Sensors Input Aux Input: Cell Voltage s standard kits include everything necessary for R&D and Product Development: Contact Stress Sensor(s) Cabling Smart Interface with USB to computer Software for monitoring and recording CSS output Sync input allows simultaneous monitoring of battery voltage Up to 16 sensors per Smart Interface 18

Summary MicroMetrics CSS provides a simple and inexpensive means of monitoring battery and cell swelling Ultra-thin form factor is non-intrusive Long cycle life means it can be permanently installed in products MicroMetrics CSS kits make the sensor easy to evaluate and use Custom designs are available for NRE charge A broad range of markets and applications insures continued support and product improvements Contact: James Kaschmitter james.kasch@micrometricsinc.com (925) 570-7251 19